Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Particle accelerator sciences”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,153 records · Page 64

Faraday cup with nanosecond response and adjustable impedance for fast electron beam characterization

A movable Faraday cup design with simple structure and adjustable impedance is described in this work. This Faraday cup has external adjustable shunt resistance for self-biased measurement setup and 50 {Omega} characteristic impedance to match with 50 {Omega} standard BNC coaxial cable and vacuum feedthroughs for nanosecond-level pulse signal measurements. Adjustable shunt resistance allows self-biased measurements to be quickly acquired to determine the electron energy distribution function. The performance of the Faraday cup is validated by tests of response time and amplitude of output signal. When compared with a reference source, the percent difference of the Faraday cup signal fall time is less than 10% for fall times greater than 10 ns. The percent difference of the Faraday cup signal pulse width is below 6.7% for pulse widths greater than 10 ns. A pseudospark-generated electron beam is used to compare the amplitude of the Faraday cup signal with a calibrated F-70 commercial current transformer. The error of the Faraday cup output amplitude is below 10% for the 4-14 kV tested pseudospark voltages. The main benefit of this Faraday cup is demonstrated by adjusting the external shunt resistance and performing the self-biased method for obtaining the electron energy distribution function. Results from a 4 kV pseudospark discharge indicate a ''double-humped'' energy distribution.

43 PARTICLE ACCELERATORS↗

A low emittance and high efficiency visible light photocathode for high brightness accelerator-based X-ray light sources

Free-electron lasers and energy recovery linacs represent a new generation of ultra-high brightness electron accelerator based x-ray sources. Photocathodes are a critical performance-limiting component of these systems. Here, we describe the development of photocathodes based on potassium-cesium-antimonide that satisfy many of the key requirements of future light sources, such as robustness, high quantum efficiency when excited with visible light, and low transverse emittance.

43 PARTICLE ACCELERATORS↗

Development of Computer Tomography System for the Soft X-ray Microscope at Ritsumeikan University

A synchrotron-based full-field imaging soft x-ray microscope was tuned appropriately to perform computer tomography. The contrast and focal depth of the optical system were evaluated by using a Fresnel zone plate as a test object of variable spatial frequency. A focal depth of 15 {mu}m was obtained at the spatial frequency of 4.3 {mu}m{sup -1} according to Rayleigh's criterion. As a first trial of three-dimensional observation using this system, the cerebral cortex of the brain of a mouse, trimmed to a columnar shape by focused ion beam milling, was studied using a wavelength of 1.87-nm.

43 PARTICLE ACCELERATORS↗

A time-of-flight backscattering spectrometer at the Spallation Neutron Source, BASIS

We describe the design and current performance of the backscattering silicon spectrometer (BASIS), a time-of-flight backscattering spectrometer built at the spallation neutron source (SNS) of the Oak Ridge National Laboratory (ORNL). BASIS is the first silicon-based backscattering spectrometer installed at a spallation neutron source. In addition to high intensity, it offers a high-energy resolution of about 3.5 {mu}eV and a large and variable energy transfer range. These ensure an excellent overlap with the dynamic ranges accessible at other inelastic spectrometers at the SNS.

43 PARTICLE ACCELERATORS↗

A solid-state Marx generator driven Einzel lens chopper

A new type of pulse chopper called an Einzel lens chopper is described. An Einzel lens placed immediately after an electron cyclotron resonance ion source is driven by high-voltage pulses generated by a newly developed solid-state Marx generator. A rectangular negative barrier pulse-voltage is controlled in time, and the barrier pulse is turned on only when a beam pulse is required. The results of successful experiments are reported herein.

43 PARTICLE ACCELERATORS↗

Generation of multi-color attosecond x-ray radiation through modulation compression

In this paper, we propose a scheme to generate tunable multi-color attosecond coherent x-ray radiation. This scheme uses a modulation compression method to generate a multi-spike prebunched kilo-ampere peak current electron beam from a few tens ampere electron beam out of a linac. Such a beam transporting through a series of undulator radiators and bunch compressors generates multi-color coherent x-ray radiation. As an illustration, we present an example to generate two attosecond pulses with 2.2 nm and 3 nm coherent x-ray radiation wavelength and more than 200 MW peak power using a 50 A 200 nm laser seeded electron beam.

43 PARTICLE ACCELERATORS↗

Imaging single electrons to enable the generation of ultrashort beams for single-shot femtosecond relativistic electron diffraction

The generation and control of relativistic electron beams well suited for ultrafast electron diffraction application has rapidly advanced, greatly benefiting from the overlap in techniques and expertise with the accelerator community. However, imaging the diffracted MeV electrons with high detection efficiency has remained an under-explored area. In this paper, we report on a quantitative study of the imaging of MeV electrons using a detection system consisting of a phosphor screen, a lens-coupling optics, and a charge-coupled device camera. It is shown that every MeV electron in the beam yields a signal well above the camera noise. With this detection efficiency, only {approx}10{sup 5} electrons per pulse are needed to obtain a high quality single-shot diffraction pattern from a crystalline sample. We measured that such a low charge beam can be as short as 30 fs rms. Further, we discuss the possibility of compressing these electron beams to sub-5 fs rms bunch length by velocity bunching using a short high gradient rf accelerating structure scheduled to be installed next year at the UCLA Pegasus Laboratory. This opens the possibility of single-shot determinations of structural changes in many ultrafast physical processes like nonequilibrium phonon dynamics or relaxation pathways in systems with strong electron-phonon coupling.

43 PARTICLE ACCELERATORS↗

Calibration method of tilt and azimuth angles for alignment of TEM tomographic tilt series

This paper describes the calibration method of the tilt and azimuth angles of specimen using a digital protractor and a laser autocollimator for alignment of electron tomography. It also suggests an easy method to check whether the specimen is tilted by 180.0 deg., and whether the azimuth angle is 0.0 deg.; the method involves the use of two images of a rod-shaped specimen collected before and after a 180.0 deg. The method is based on the assumption that these images are symmetric about the tilt axis when the azimuth angle is 0.0 deg. In addition, we used an experiment to demonstrate the effect of the incorrect angles on reconstructed images and simulated the image quality against distance away from tilt axis.

43 PARTICLE ACCELERATORS↗

Note: Recent achievements at the 60-MeV Linac for sub-picosecond terahertz radiation at the Pohang Accelerator Laboratory

A femtosecond (fs) terahertz (THz) linac has been constructed to generate fs-THz radiation by using ultrashort electron beam at the Pohang Accelerator Laboratory. To generate an ultrashort electron beam with 60-MeV energy, a chicane bunch compressor has been adopted. Simulation studies have been conducted to design the linac. In this note, recent achievements at 60-MeV linac are presented.

43 PARTICLE ACCELERATORS↗

Optimizing the front end test stand high performance H{sup -} ion source at RAL

The aim of the front end test stand project is to demonstrate that chopped low energy H{sup -} beams of high quality can be produced. The beam line currently consists of the ion source, a 3 solenoid low energy beam transport and a suite of diagnostics. A brief status report of the radio frequency quadrupole is given. This paper details the work to optimize the ion source performance. A new high power pulsed discharge power supply with greater reliability has been developed to allow long term, stable operation at 50 Hz with a 60 A, 2.2 ms discharge pulse and up to 100 A at 1.2 ms. The existing extraction power supply has been modified to operate up to 22 kV. Results from optical spectroscopy measurements and their application to source optimization are summarized. Source emittances and beam currents of 60 mA are reported.

43 PARTICLE ACCELERATORS↗

Advanced light ion source extraction system for a new electron cyclotron resonance ion source geometry at Saclay

One of the main goal of intense light ion injector projects such as IPHI, IFMIF, or SPIRAL2, is to produce high current beams while keeping transverse emittance as low as possible. To prevent emittance growth induced in a dual solenoid low energy transfer line, its length has to be minimized. This can be performed with the advanced light ion source extraction system concept that we are developing: a new ECR 2.45 GHz type ion source based on the use of an additional low energy beam transport (LEBT) short length solenoid close to the extraction aperture to create the resonance in the plasma chamber. The geometry of the source has been considerably modified to allow easy maintenance of each component and to save space in front of the extraction. The source aims to be very flexible and to be able to extract high current ion beams at energy up to 100 kV. A specific experimental setup for this source is under installation on the BETSI test bench, to compare its performances with sources developed up to now in the laboratory, such as SILHI, IFMIF, or SPIRAL2 ECR sources. This original extraction source concept is presented, as well as electromagnetic simulations with OPERA-2D code. Ion beam extraction in space charge compensation regime with AXCEL, and beam dynamics simulation with SOLMAXP codes show the beam quality improvement at the end of the LEBT.

43 PARTICLE ACCELERATORS↗

The second generation Singapore high resolution proton beam writing facility

A new proton beam focusing facility, designed for proton beam writing (PBW) applications has been tested. PBW allows for proximity free structuring of high aspect ratio, high-density 3D nanostructures. The new facility is designed around OM52 compact quadrupole lenses capable of operating in a variety of high demagnification configurations. Performance tests show that proton beams can be focused down to 19.0 x 29.9 nm{sup 2} and single line scans show a beam width of 12.6 nm. The ultimate goal of sub 10 nm structuring with MeV protons will be discussed.

43 PARTICLE ACCELERATORS↗

Observation of Neutron Skyshine from an Accelerator Based Neutron Source

A key feature of neutron based interrogation systems is the need for adequate provision of shielding around the facility. Accelerator facilities adapted for fast neutron generation are not necessarily suitably equipped to ensure complete containment of the vast quantity of neutrons generated, typically >10{sup 11} n{center_dot}s{sup -1}. Simulating the neutron leakage from a facility is not a simple exercise since the energy and directional distribution can only be approximated. Although adequate horizontal, planar shielding provision is made for a neutron generator facility, it is sometimes the case that vertical shielding is minimized, due to structural and economic constraints. It is further justified by assuming the atmosphere above a facility functions as an adequate radiation shield. It has become apparent that multiple neutron scattering within the atmosphere can result in a measurable dose of neutrons reaching ground level some distance from a facility, an effect commonly known as skyshine. This paper describes a neutron detection system developed to monitor neutrons detected several hundred metres from a neutron source due to the effect of skyshine.

43 PARTICLE ACCELERATORS↗

Development of an Accelerator Mass Spectrometer based on a Cyclotron

An accelerator mass spectrometer based on a cyclotron has been developed, and a prototype of the injection beam line has been constructed. Mass resolution of the cyclotron is designed to be over 4000. A sawtooth RF buncher in the beam line and a flat-topping RF system for the cyclotron were utilized to enhance beam transmission efficiency, which is a primary factor for improvement compared to previous cyclotron mass spectrometers. The injection beam line comprises an ion source, Einzel lens, RF buncher, 90 deg. dipole magnet and a slit box containing beam diagnostic devices. A carbon beam was measured at the location of the slit box, and beam phase spaces will be measured. The design of a cyclotron magnet was done, and orbit tracking was carried out using cyclotron optics codes. A scheme of radial injection was chosen to place a beam on the equilibrium orbit of the cyclotron. The injection scheme will be optimized after the beam measurements are completed.

43 PARTICLE ACCELERATORS↗

Deuterated Liquid Scintillators: A New Tool for Neutron Measurements

The response of large (4x6) deuterated liquid scintillators (up to 10 cm diameter by 15 cm) to neutrons in the energy range from 0.5 MeV to 20 MeV has been studied using several nuclear reactions, including d(d,n), and {sup 12}C(d,n){sup 13}N, at the University of Notre Dame FN tandem accelerator. The latter two reactions utilized 9 MeV and 16 MeV deuteron beams, including a pulsed beam that also permitted time-of-flight (ToF) measurements. Combining pulse-shape discrimination and (ToF) allows gating on specific neutron energy groups to determine the detector response to specific neutron energies. Newly-obtained and optimized pulse shape discrimination using digitized pulse analysis from these detectors will be presented in this paper. These measurements confirmed the ability of these detectors to provide useful neutron spectra without ToF.

43 PARTICLE ACCELERATORS↗

Light ion source for proton/deuteron production at CEA Saclay for the Spiral2 project

The production of rare radioactive ion beam (RIB) far from the valley of stability is one of the final purposes of the Spiral2 facility in Caen. The RIB will be produced by impinging a deuteron beam onto a carbon sample to produce a high neutron flux, which will interact with a uranium target. The primary deuteron beam is produced by an ion source based on ECR plasma generation. The deuteron source and the low energy beam transport (LEBT) has been assembled and tested at CEA Saclay. Diagnostics from other laboratories were implemented on the LEBT in order to characterize the deuteron beam produced and compare it to the initial simulations. The ion source has been based on a SILHI-type source, which has demonstrated good performances in pulsed and continuous mode, and also a very good reliability on long term operation. The 5 mA of deuteron beam required at the RFQ entrance is extracted from the plasma source at the energy of 40 kV. After a brief description of the experimental set-up, this article reports on the first beam characterization experiments.

43 PARTICLE ACCELERATORS↗

Ion optics of RHIC electron beam ion source

RHIC electron beam ion source has been commissioned to operate as a versatile ion source on RHIC injection facility supplying ion species from He to Au for Booster. Except for light gaseous elements RHIC EBIS employs ion injection from several external primary ion sources. With electrostatic optics fast switching from one ion species to another can be done on a pulse to pulse mode. The design of an ion optical structure and the results of simulations for different ion species are presented. In the choice of optical elements special attention was paid to spherical aberrations for high-current space charge dominated ion beams. The combination of a gridded lens and a magnet lens in LEBT provides flexibility of optical control for a wide range of ion species to satisfy acceptance parameters of RFQ. The results of ion transmission measurements are presented.

43 PARTICLE ACCELERATORS↗

Time-resolved soft x-ray absorption setup using multi-bunch operation modes at synchrotrons

Here, we report on a novel experimental apparatus for performing time-resolved soft x-ray absorption spectroscopy in the sub-ns time scale using non-hybrid multi-bunch mode synchrotron radiation. The present setup is based on a variable repetition rate Ti:sapphire laser (pump pulse) synchronized with the {approx}500 MHz x-ray synchrotron radiation bunches and on a detection system that discriminates and singles out the significant x-ray photon pulses by means of a custom made photon counting unit. The whole setup has been validated by measuring the time evolution of the L{sub 3} absorption edge during the melting and the solidification of a Ge single crystal irradiated by an intense ultrafast laser pulse. These results pave the way for performing synchrotron time-resolved experiments in the sub-ns time domain with variable repetition rate exploiting the full flux of the synchrotron radiation.

43 PARTICLE ACCELERATORS↗