Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “PHASE DETECTOR”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,153 records · Page 64

Hollow Ptychography: Toward Simultaneous 4D Scanning Transmission Electron Microscopy and Electron Energy Loss Spectroscopy

With the recent development of high-acquisition-speed pixelated detectors, 4D scanning transmission electron microscopy (4D-STEM) is becoming routinely available in high-resolution electron microscopy. 4D-STEM acts as a “universal” method that provides local information on materials that is challenging to extract from bulk techniques. It extends conventional STEM imaging to include super-resolution techniques and to provide quantitative phase-based information, such as differential phase contrast, ptychography, or Bloch wave phase retrieval. However, an important missing factor is the chemical and bonding information provided by electron energy loss spectroscopy (EELS). 4D-STEM and EELS cannot currently be acquired simultaneously due to the overlapping geometry of the detectors. Here, the feasibility of modifying the detector geometry to overcome this challenge for bulk specimens is demonstrated, and the use of a partial or defective detector for ptycholgaphic structural imaging is explored. Here, results show that structural information beyond the diffraction-limit and chemical information from the material can be extracted together, resulting in simultaneous multi-modal measurements, adding the additional dimensions of spectral information to 4D datasets.

4D-scanning transmitting electron microscopy (STEM↗

ICARUS at the Fermilab Short-Baseline Neutrino program: initial operation

The ICARUS collaboration employed the 760-ton T600 detector in a successful 3-year physics run at the underground LNGS laboratory, performing a sensitive search for LSND-like anomalous $\nu _e$ appearance in the CERN Neutrino to Gran Sasso beam, which contributed to the constraints on the allowed neutrino oscillation parameters to a narrow region around 1 eV$^2$. After a significant overhaul at CERN, the T600 detector has been installed at Fermilab. In 2020 the cryogenic commissioning began with detector cool down, liquid argon filling and recirculation. ICARUS then started its operations collecting the first neutrino events from the booster neutrino beam (BNB) and the Neutrinos at the Main Injector (NuMI) beam off-axis, which were used to test the ICARUS event selection, reconstruction and analysis algorithms. ICARUS successfully completed its commissioning phase in June 2022. The first goal of the ICARUS data taking will be a study to either confirm or refute the claim by Neutrino-4 short-baseline reactor experiment. ICARUS will also perform measurement of neutrino cross sections with the NuMI beam and several Beyond Standard Model searches. After the first year of operations, ICARUS will search for evidence of sterile neutrinos jointly with the Short-Baseline Near Detector, within the Short-Baseline Neutrino program. In this paper, the main activities carried out during the overhauling and installation phases are highlighted. Preliminary technical results from the ICARUS commissioning data with the BNB and NuMI beams are presented both in terms of performance of all ICARUS subsystems and of capability to select and reconstruct neutrino events.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Analysis of beta-decay rates for Ag 108, Ba 133, Eu 152, Eu 154, Kr 85, Ra 226, and Sr 90, measured at the Physikalisch-Technische Bundesanstalt from 1990 to 1996

We present the results of an analysis of measurements of the beta-decay rates of Ag 108, Ba 133, Eu 152, Eu 154, Kr 85, Ra 226, and Sr 90 acquired at the Physikalisch-Technische Bundesanstalt from 1990 through 1995. Although the decay rates vary over a range of 165 to 1 and the measured detector current varies over a range of 19 to 1, the detrended and normalized count rate measurements exhibit a sinusoidal annual variation with amplitude in the small range 0.068%-0.088% (mean 0.081%, standard deviation 0.0072%, a rejection of the zero-amplitude hypothesis) and phase-of-maximum in the small range 0.062-0.083 (January 23 to January 30). In comparing these results with those of other related experiments that yield different results, it may be significant that this experiment, at a standards laboratory, seems to be unique in using a 4π detector. These results are compatible with a solar influence, and do not appear to be compatible with an experimental or environmental influence. It is possible that Ba 133 measurements are also subject to a non-solar (possibly cosmic) influence.

79 ASTRONOMY AND ASTROPHYSICS↗

Samurai project: Verifying the consistency of black-hole-binary waveforms for gravitational-wave detection

We quantify the consistency of numerical-relativity black-hole-binary waveforms for use in gravitational-wave (GW) searches with current and planned ground-based detectors. We compare previously published results for the (l=2,|m|=2) mode of the gravitational waves from an equal-mass nonspinning binary, calculated by five numerical codes. We focus on the 1000M (about six orbits, or 12 GW cycles) before the peak of the GW amplitude and the subsequent ringdown. We find that the phase and amplitude agree within each code's uncertainty estimates. The mismatch between the (l=2,|m|=2) modes is better than 10{sup -3} for binary masses above 60M{sub {center_dot}} with respect to the Enhanced LIGO detector noise curve, and for masses above 180M{sub {center_dot}} with respect to Advanced LIGO, Virgo, and Advanced Virgo. Between the waveforms with the best agreement, the mismatch is below 2x10{sup -4}. We find that the waveforms would be indistinguishable in all ground-based detectors (and for the masses we consider) if detected with a signal-to-noise ratio of less than {approx_equal}14, or less than {approx_equal}25 in the best cases.

79 ASTRONOMY AND ASTROPHYSICS↗

Combination and interpretation of differential Higgs boson production cross sections in proton-proton collisions at $ \sqrt{s}=13 $ TeV

Precision measurements of Higgs boson differential production cross sections are a key tool to probe the properties of the Higgs boson and test the standard model. New physics can affect both Higgs boson production and decay, leading to deviations from the distributions that are expected in the standard model. In this paper, combined measurements of differential spectra in a fiducial region matching the experimental selections are performed, based on analyses of four Higgs boson decay channels (γγ, ZZ$^{(*)}$, WW$^{(*)}$, and ττ) using proton-proton collision data recorded with the CMS detector at $ \sqrt{s}=13 $ TeV, corresponding to an integrated luminosity of 138 fb$^{−1}$. The differential measurements are extrapolated to the full phase space and combined to provide the differential spectra. A measurement of the total Higgs boson production cross section is also performed using the γγ and ZZ decay channels, with a result of $ {53.4}_{-2.9}^{+2.9}{\left(\textrm{stat}\right)}_{-1.8}^{+1.9}\left(\textrm{syst}\right) $ pb, consistent with the standard model prediction of 55.6 ± 2.5 pb. The fiducial measurements are used to compute limits on Higgs boson couplings using the κ-framework and the SM effective field theory.[graphic not available: see fulltext]

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Volume fraction determination of the annular three-phase flow of gas-oil-water using adaptive neuro-fuzzy inference system

The use of adaptive neuro-fuzzy inference system (ANFIS) has been reported for predicting the volume fractions in a gas–oil–water multiphase system. In fact, the volume fractions in the annular three-phase flow are measured based on a dual energy metering system consisting of {sup 152}Eu and {sup 137}Cs and one NaI detector using ANFIS. Since the summation of volume fractions is constant, therefore ANFIS must predict only two volume fractions. In this study, three ANFIS networks are applied. The first is utilized to predict the gas and water volume fractions. The next one is applied to predict the gas and oil, and the last one is used to predict the water and oil volume fractions. In the next step, ANFIS networks must be trained based on numerically obtained data from MCNP-X code. Then, the average testing errors of these three networks are computed and compared. The network with the least error has been selected as the best predictor model.

07 ISOTOPE AND RADIATION SOURCES↗

Atomic electrostatic maps of 1D channels in 2D semiconductors using 4D scanning transmission electron microscopy

Defects in materials give rise to fluctuations in electrostatic fields that reflect the local charge density, but imaging this with single atom sensitivity is challenging. However, if possible, this provides information about the energetics of adatom binding, localized conduction channels, molecular functionality and their relationship to individual bonds. Here, ultrastable electron-optics are combined with a high-speed 2D electron detector to map electrostatic fields around individual atoms in 2D monolayers using 4D scanning transmission electron microscopy. Simultaneous imaging of the electric field, phase, annular dark field and the total charge in 2D MoS 2 and WS 2 is demonstrated for pristine areas and regions with 1D wires. The in-gap states in sulphur line vacancies cause 1D electron-rich channels that are mapped experimentally and confirmed using density functional theory calculations. We show how electrostatic fields are sensitive in defective areas to changes of atomic bonding and structural determination beyond conventional imaging.

36 MATERIALS SCIENCE↗

X-ray spectroscopic study of amorphous and polycrystalline PbO films, α-PbO, and β-PbO for direct conversion imaging

We investigated the electronic structure of Lead Oxide (PbO) – one of the most promising photoconductor materials for direct conversion x-ray imaging detectors, using soft x-ray emission and absorption spectroscopy. Two structural configurations of thin PbO layers, namely the polycrystalline and the amorphous phase, were studied, and compared to the properties of powdered α-PbO and β-PbO samples. In addition, we performed calculations within the framework of density functional theory and found an excellent agreement between the calculated and the measured absorption and emission spectra, which indicates high accuracy of our structural models. Our work provides strong evidence that the electronic structure of PbO layers, specifically the width of the band gap and the presence of additional interband and intraband states in both conduction and valence band, depend on the deposition conditions. We tested several model structures using DFT simulations to understand what the origin of these states is. The presence of O vacancies is the most plausible explanation for these additional electronic states. Several other plausible models were ruled out including interstitial O, dislocated O and the presence of significant lattice stress in PbO.

42 ENGINEERING↗

Full Simulation of CMS for Run-3 and Phase-2

In this contribution we report the status of the CMS Geant4 simulation and the prospects for Run-3 and Phase-2. Firstly, we report about our experience during the start of Run-3 with Geant4 10.7.2, the common software package DD4hep for geometry description, and VecGeom runtime geometry library. In addition, FTFP_BERT_EMM Physics List and CMS configuration for tracking in magnetic field have been utilized. For the first time, for the Grid mass production of Monte-Carlo, this combination of components is used. Further simulation improvements are under development targeting Run-3 such as the switch to the new Geant4 11.1 in production, that provides several features important for the optimization of simulation, for example the new transportation process with built-in multiple scattering, neutron general process, custom tracking manager, G4HepEm sub-library, and others. We will present evaluation of various options, validation results, and the final choice of simulation configuration for 2023 production and beyond. The performance of the CMS full simulation for Run-2 and Run-3 will also be discussed. CMS development plan for the Phase-2 Geant4 based simulation is very ambitious, and it includes a new geometry description, physics, and simulation configurations. The progress on new detector descriptions and full simulation will be presented as well as the R&D in progress to reduce compute capacity needs.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

R and D of crystal scintillators from enriched isotopes for high sensitivity double β decay experiments

Experiments to search for neutrinoless double beta decay enters to a new phase when a sensitivity on the level of T{sub 1/2}∼10{sup 26}−10{sup 28} yr is required. Scintillating low temperature detectors possess important properties required for high-sensitivity double beta decay experiments: presence of elements of interest, high energy resolution and detection efficiency, low level of background thanks to excellent particle discrimination ability. High concentration of isotope of interest and as low as possible radioactive contamination are important requirements to crystal scintillators. Other crucial issues are maximal output of detectors and minimal loss of enriched materials. Prospects of several scintillation materials, enriched in isotopes promising for double beta decay experiments, are discussed.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Data transmission by quantum matter wave modulation

Abstract Classical communication schemes exploiting wave modulation are the basis of our information era. Quantum information techniques with photons enable future secure data transfer in the dawn of decoding quantum computers. Here we demonstrate that also matter waves can be applied for secure data transfer. Our technique allows the transmission of a message by a quantum modulation of coherent electrons in a biprism interferometer. The data is encoded in the superposition state by a Wien filter introducing a longitudinal shift between separated matter wave packets. The transmission receiver is a delay line detector performing a dynamic contrast analysis of the fringe pattern. Our method relies on the Aharonov–Bohm effect but does not shift the phase. It is demonstrated that an eavesdropping attack will terminate the data transfer by disturbing the quantum state and introducing decoherence. Furthermore, we discuss the security limitations of the scheme due to the multi-particle aspect and propose the implementation of a key distribution protocol that can prevent active eavesdropping.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Design improvements to cables and connectors in the Majorana Demonstrator

The Majorana Demonstrator is an experiment constructed to search for neutrinoless double-beta decays in germanium-76 and to demonstrate the feasibility to deploy a ton-scale experiment in a phased and modular fashion. It consists of two modular arrays of natural and 76 Ge-enriched germanium p-type point contact detectors totaling 44.1 kg, located at the 4850 level of the Sanford Underground Research Facility in Lead, South Dakota, USA. The Demonstrator uses custom high voltage cables to bias the detectors, as well as custom signal cables and connectors to read out the charge deposited at the point contact of each detector. These low-mass cables and connectors must meet stringent radio purity requirements while being subjected to thermal and mechanical stress. A number of issues have been identified with the currently installed cables and connectors. An improved set of cables and connectors for the Majorana Demonstrator are being developed with the aim of increasing their overall reliability and connectivity. In conclusion, we will discuss some of the issues encountered with the current cables and connectors as well as our improved designs and their initial performance.

42 ENGINEERING↗

Region-of-Interest Tomography for Grating-Based X-Ray Differential Phase-Contrast Imaging

We report numerical and experimental results demonstrating accurate region-of-interest computed tomography (CT) reconstruction based on differential phase-contrast projection (DPC) images. The approach removes the constraint of covering the entire sample within the field of view of the image detector. Particularly for biomedical applications, the presented DPC-CT region-of-interest approach will allow for the visualization of previously inaccessible details deep inside an entire animal or organ. We envisage that this development will also be of interest for potential future clinical applications, because grating-based DPC-CT can be implemented with standard x-ray tube sources.

60 APPLIED LIFE SCIENCES↗

Experimental strategies for imaging bioparticles with femtosecond hard X-ray pulses

This study explores the capabilities of the Coherent X-ray Imaging Instrument at the Linac Coherent Light Source to image small biological samples. The weak signal from small samples puts a significant demand on the experiment. Aerosolized Omono River virus particles of ~40 nm in diameter were injected into the submicrometre X-ray focus at a reduced pressure. Diffraction patterns were recorded on two area detectors. The statistical nature of the measurements from many individual particles provided information about the intensity profile of the X-ray beam, phase variations in the wavefront and the size distribution of the injected particles. The results point to a wider than expected size distribution (from ~35 to ~300 nm in diameter). This is likely to be owing to nonvolatile contaminants from larger droplets during aerosolization and droplet evaporation. The results suggest that the concentration of nonvolatile contaminants and the ratio between the volumes of the initial droplet and the sample particles is critical in such studies. The maximum beam intensity in the focus was found to be 1.9 × 10 12 photons per µm 2 per pulse. The full-width of the focus at half-maximum was estimated to be 500 nm (assuming 20% beamline transmission), and this width is larger than expected. Under these conditions, the diffraction signal from a sample-sized particle remained above the average background to a resolution of 4.25 nm. Finally, the results suggest that reducing the size of the initial droplets during aerosolization is necessary to bring small particles into the scope of detailed structural studies with X-ray lasers.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Ab initio structure determination of nanocrystals of organic pharmaceutical compounds by electron diffraction at room temperature using a Timepix quantum area direct electron detector

A specialized quantum area detector for electron diffraction studies makes it possible to solve the structure of small organic compound nanocrystals in non-cryo conditions by direct methods. Until recently, structure determination by transmission electron microscopy of beam-sensitive three-dimensional nanocrystals required electron diffraction tomography data collection at liquid-nitrogen temperature, in order to reduce radiation damage. Here it is shown that the novel Timepix detector combines a high dynamic range with a very high signal-to-noise ratio and single-electron sensitivity, enabling ab initio phasing of beam-sensitive organic compounds. Low-dose electron diffraction data (∼0.013 e{sup −} Å{sup −2} s{sup −1}) were collected at room temperature with the rotation method. It was ascertained that the data were of sufficient quality for structure solution using direct methods using software developed for X-ray crystallography (XDS, SHELX) and for electron crystallography (ADT3D/PETS, SIR2014)

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Optical Gaussian beam interaction with one-dimensional thermal wave in the Raman-Nath configuration

Optical Gaussian beam interaction with a one-dimensional temperature field in the form of a thermal wave in the Raman-Nath configuration is analyzed. For the description of the Gaussian beam propagation through the nonstationary temperature field the complex geometric optics method was used. The influence of the refractive coefficient modulation by thermal wave on the complex ray phase, path, and amplitude was taken into account. It was assumed that for detection of the modulated Gaussian beam parameters two types of detector can be used: quadrant photodiodes or centroidal photodiodes. The influence of such parameters as the size and position of the Gaussian beam waist, the laser-screen (detector) distance, the thermal wave beam position and width, as well as thermal wave frequency and the distance between the probing optical beam axis and source of thermal waves on the so-called normal signal was taken into account.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

NCSP IER 422 CED-3b Documentation

A Subcritical Copper-Reflected α-phase Plutonium (SCRαP) integral benchmark experiment has been designed and measured. In this experiment, multiplication is approximated using correlated neutron data from a detector system consisting of 3He tubes inside high density polyethylene (HDPE). Measurements were performed on various subcritical experimental configurations consisting of a weapons-grade plutonium sphere surrounded by different Cu thicknesses. In addition to the proposed base experimental configurations with Cu, additional configurations were performed with the plutonium ball nested in various thicknesses of interleaved HDPE spherical shells mixed in with the Cu shells. The HDPE is intended to provide fast neutron moderation and reflection, resulting in additional measurements with differing multiplication, spectra, and nuclear data sensitivity.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗