Li Isotope Signatures using Optical Spectroscopies

The primary goal of this work is to investigate the detection capabilities of laser ablation molecular isotopic spectrometry (LAMIS) and Raman spectroscopy for lithium isotopic determination as related to Li enrichment activities. LAMIS is an emerging spectroscopic technique that takes advantage of the fact that molecules exhibit much larger isotopic wavelength shifts in molecular emission spectra than their atomic counterparts. Raman spectroscopy has been shown to exhibit isotopic shifts if a given molecular vibration involves the isotope of interest. Both techniques are comprised of the same basic hardware: a spectrometer, a laser system (pulsed for LAMIS, pulsed or CW for Raman), and an intensified charge-coupled device (ICCD). Shifts in Raman spectra due to lithium isotopes in Li 2 C0 3 and LiOH*H 2 0 were observed. LAMIS measurements of the same compounds have not been successful yet, as no lithium containing molecular emissions have been identified to this point. However, an isotopic shift of the self-reversal of an atomic lithium emission was observed, which is another optical technique used to measure isotopes.

07 ISOTOPE AND RADIATION SOURCES↗

Halide perovskites enable polaritonic XY spin Hamiltonian at room temperature

Exciton polaritons, the part-light and part-matter quasiparticles in semiconductor optical cavities, are promising for exploring Bose–Einstein condensation, non-equilibrium many-body physics and analogue simulation at elevated temperatures. However, a room-temperature polaritonic platform on par with the GaAs quantum wells grown by molecular beam epitaxy at low temperatures remains elusive. Here, the operation of such a platform calls for long-lifetime, strongly interacting excitons in a stringent material system with large yet nanoscale-thin geometry and homogeneous properties. Here, we address this challenge by adopting a method based on the solution synthesis of excitonic halide perovskites grown under nanoconfinement. Such nanoconfinement growth facilitates the synthesis of smooth and homogeneous single-crystalline large crystals enabling the demonstration of XY Hamiltonian lattices with sizes up to 10 × 10. With this demonstration, we further establish perovskites as a promising platform for room temperature polaritonic physics and pave the way for the realization of robust mode-disorder-free polaritonic devices at room temperature.

36 MATERIALS SCIENCE↗

GaAs solar cells grown on intentionally contaminated GaAs substrates

III-V materials such as GaAs and GaInP have some of the best electronic and optical properties of any semiconductor materials, but deposition of these materials relies on high-quality single crystal GaAs substrates for their superior performance. Unfortunately, the cost of these substrates makes these high-efficiency devices only accessible in high-value or niche markets. In this study, we explore the effect of growing bulk GaAs crystals with lower purity input materials in order to reduce their cost. We observe that intentional impurities added to the melt before the crystal growth occurs segregate to the top of the boule. Single junction GaAs solar cells grown on substrates made from contaminated boules showed no performance degradation compared to a high-purity control substrate. These results suggest that lower purity Ga and As source materials can be used during crystal growth to reduce the cost of substrates.

36 MATERIALS SCIENCE↗

Tracking Thermal Transport in Colloidal Quantum Dot Films Using in Situ Time-Resolved X-ray Diffraction

Colloidal quantum dots (QDs) and their thin films are increasingly used in electronic and photonic devices replacing traditional bulk semiconductors. However, thermal properties of QDs remain underexplored relative to device development efforts. This study shows the use of time-resolved X-ray diffraction as a contact-free method to probe the thermal response of QDs in environments representative of the active layer in QD optoelectronic devices, providing in situ insights for future thermal management strategies. Through the extraction of Debye–Waller factors on a subnanosecond time scale, we directly capture the heating and cooling of core/shell CdSe/CdS QDs following pulsed optical excitation. In a QD thin film that actively provides optical gain, the thermal conductivity is found to be as low as 0.13 W m –1 K –1 , because of the poor heat flow between close-packed QD solids. For QDs dispersed in liquids, interfacial thermal conductance dominates thermal relaxation, with a conductance of 15 MW m –2 K –1 .

36 MATERIALS SCIENCE↗

Tunable rainbow light trapping in ultrathin resonator arrays

Abstract Rainbow light trapping in plasmonic devices allows for field enhancement of multiple wavelengths within a single device. However, many of these devices lack precise control over spatial and spectral enhancement profiles and cannot provide extremely high localised field strengths. Here we present a versatile, analytical design paradigm for rainbow trapping in nanogroove arrays by utilising both the groove-width and groove-length as tuning parameters. We couple this design technique with fabrication through multilayer thin-film deposition and focused ion beam milling, which enables the realisation of unprecedented feature sizes down to 5 nm and corresponding extreme normalised local field enhancements up to 10 3 . We demonstrate rainbow trapping within the devices through hyperspectral microscopy and show agreement between the experimental results and simulation. The combination of expeditious design and precise fabrication underpins the implementation of these nanogroove arrays for manifold applications in sensing and nanoscale optics.

42 ENGINEERING↗

Computational toolkit for predicting thickness of 2D materials using machine learning and autogenerated dataset by large language model

The thickness of 2D materials not only plays a crucial role in determining the performance of nanoelectronic and optoelectronic devices but also introduces complexities in predicting volume-dependent properties, such as energy storage capacity, due to the intrinsic vacuum within these materials. Although a plethora of experimental techniques, including but not limited to optical contrast, Raman spectroscopy, nonlinear optical spectroscopy, near-field optical imaging, and hyperspectral imaging, facilitate the measurement of 2D material thickness, comprehensive data for many materials remain elusive. Over the past decade, the exponential proliferation of 2D materials and their heterostructures has outstripped the capabilities of conventional experimental and computational approaches. In this evolving landscape, machine learning (ML) has emerged as an indispensable tool, offering a scalable approach to augment these traditional methodologies. Addressing the critical gap, we introduce THICK2D—Thickness Hierarchy Inference and Calculation Kit for 2D Materials. This Python-based computational framework harnesses an autogenerated thickness database, developed using large language models, and advanced ML algorithms to facilitate the rapid and scalable estimation of material thickness, relying solely on crystallographic data. To demonstrate the utility and robustness of THICK2D, we successfully used the toolkit to predict the thickness of more than 8000 2D-based materials, sourced from two extensive 2D materials databases. THICK2D is disseminated as an open-source utility, accessible on GitHub at https://github.com/gmp007/THICK2D, and archived on Zenodo at https://10.5281/zenodo.11216648.

Ekuma, Chinedu E. (ORCID:0000000258527556)↗

Er Al :Al 2 ⁢O 3 for telecom-band photonics: Electronic structure and optical properties

Er-doped Al 2 ⁢O 3 is a promising host for telecom-band integrated photonics. Here, in this study, we combine ab initio calculations with a symmetry-resolved analysis to elucidate substitutional Er on the Al site (Er Al ) in 𝛼−Al 2 ⁢O 3 . First-principles relaxations confirm the structural stability of Er Al . We then use the local trigonal crystal-field symmetry to classify the Er-derived impurity levels by irreducible representations and to derive polarization-resolved electric-dipole selection rules, explicitly identifying the symmetry-allowed 𝑓−𝑑 hybridization channels. Kubo-Greenwood absorption spectra computed from Kohn-Sham states quantitatively corroborate these symmetry predictions. Furthermore, we connect the calculated intra-4⁢𝑓 line strengths to Judd-Ofelt theory, clarifying the role of 4⁢𝑓−5⁢𝑑 admixture in enabling optical activity. Notably, we predict a characteristic absorption near 1.47 µ⁢m (telecom band), relevant for on-chip amplification and emission. To our knowledge, a symmetry-resolved first-principles treatment of Er:Al 2 ⁢O 3 with an explicit Judd-Ofelt interpretation has not been reported, providing a transferable framework for tailoring rare-earth dopants in wide-band-gap oxides for integrated photonics. Our results for the optical spectra are in good agreement with experimental data. The resulting symmetry-based selection rules translate directly to polarization-dependent coupling in Al 2 ⁢O 3 integrated photonic waveguides and resonators, enabling device-level design of TE/TM-mode interaction with Er emitters in the 1.5-µ⁢m telecom band.

Er-doped Al2O3↗

Scintillation light in SBND: simulation, reconstruction, and expected performance of the photon detection system

SBND is the near detector of the Short-Baseline Neutrino program at Fermilab. Its location near to the Booster Neutrino Beam source and relatively large mass will allow the study of neutrino interactions on argon with unprecedented statistics. This paper describes the expected performance of the SBND photon detection system, using a simulated sample of beam neutrinos and cosmogenic particles. Its design is a dual readout concept combining a system of 120 photomultiplier tubes, used for triggering, with a system of 192 X-ARAPUCA devices, located behind the anode wire planes. Furthermore, covering the cathode plane with highly-reflective panels coated with a wavelength-shifting compound recovers part of the light emitted towards the cathode, where no optical detectors exist. We show how this new design provides a high light yield and a more uniform detection efficiency, an excellent timing resolution and an independent 3D-position reconstruction using only the scintillation light. Finally, the whole reconstruction chain is applied to recover the temporal structure of the beam spill, which is resolved with a resolution on the order of nanoseconds.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Carrier Dynamics of Polar, Semipolar, and Nonpolar InGaN/GaN LEDs Measured by Small-Signal Electroluminescence

The carrier dynamics in InGaN/GaN LEDs are directly tied to their efficiency and maximum modulation speed, which are important metrics for solid-state lighting, displays, and optical communication. We measure the carrier dynamics of nonpolar, semipolar, and commercial c-plane InGaN/GaN LEDs using small-signal electroluminescence methods. Rate equations and a small-signal circuit are used to model the carrier dynamics. The model is fit to the optical frequency response and input impedance of the LEDs to extract the carrier lifetimes and the recombination rates. The results offer insight into the underlying causes of efficiency droop and the green gap, and inform device design strategies.

42 ENGINEERING↗

Tunable Laser-Plasma Amplifier (Final Report)

Exploration at the laser intensity frontier has always offered new avenues for physics and reaching beyond this frontier is a grand challenge. Present-day petawatt-class lasers provide focused intensities on target of 10 22 W/cm 2 , corresponding to electric fields of 200 TV/m, while laser-plasma amplification opens a route for focused intensities well above 10 23 W/cm 2 . Intensities in this range provide the ability to test quantum electrodynamics in the unexplored low-energy, strong-field regime where signatures for new physics may arise. The behavior of matter under such extraordinary conditions is a rich and fascinating subject, not only in its own right in fundamental plasma physics, but for the many potential applications that promise to enrich the natural sciences in the future, including compact electron-beam, ion-beam particle accelerators, and ultra-bright X-ray sources. Although laser systems are now under construction internationally to access intensities of 10 23 W/cm 2 , the current technologies used appear to be fundamentally limited to these intensities. The realization of intensities beyond 10 23 W/cm 2 using parametric amplification in plasmas promises a breakthrough in high-energy density physics. Parametric amplification using Raman scattering in a plasma could provide the enabling technology for the generation of ultra-high-power laser pulses, but a more complete understanding of the nonlinear optics of plasmas is required. There is a significant gap in well-diagnosed laser-plasma instability studies of nonlinear plasma-wave phenomena, which are critical to understand for future laser-plasma devices. To achieve an efficient laser-plasma amplifier, plasma waves must be driven to large amplitude where significant energy can be rapidly transferred from the pump to the seed over the pulse duration of the seed. Simulations suggest that this nonlinear pump depletion regime can be achieved in the “pi-pulse” amplification regime. While simulations show this optimal regime with efficient amplification, it has remained elusive in experiments and there is a growing consensus within the community that thermal effects and pump beam limitations prevent laser-plasma amplifiers from progressing through the linear regime into the nonlinear pump depletion regime. Previous experiments have been significantly limited by the laser power available at the necessary wavelengths for the seed laser; therefore, the amplification is required to start in the linear regime where it is sensitive to many deleterious effects. The enabling technology (currently unique to plasma-wave amplification in the world) at the University of Rochester is the ability to provide a seed pulse with sufficient power (4 mJ/100 fs seed) to immediately drive nonlinear plasma waves into the pi-pulse regime and to tune its wavelength to optimize the efficiency of energy transfer. This in combination with the state-of-the-art OMEGA heater beams providing multiple kilojoules in a nanosecond to sufficiently heat the plasma make this system distinct from previous studies. These heater beams will provide, for the first time in Raman amplification studies, a homogeneous electron temperature high enough to prevent pump beam propagation issues that have plagued previous experiments. These systems will provide a platform for driving electron-plasma waves into the nonlinear regime where pump depletion and pulse shortening are predicted to lead to high amplification efficiencies (>30%). The Team has made significant progress through prior support from DOE Fusion Energy Sciences [DOE Office of Science Award Number DE-SC0016253 (2016-2022)]. This includes twenty-two peer-reviewed manuscripts, one patent, ten contributed talks presented at international conferences, and research that was highlighted as invited talks at fifteen international conferences. The broader impacts of this research are evident in the support of early career scientists, two Ph.D. theses, four current graduate students, a Masters Project, two undergraduate researchers, and an underrepresented minority student hired through the California Alliance for Minority Participation who now works as a Research Engineer in the group. This research met all of the funded research objectives and the highlights from primary Raman amplification thrust of this work are discussed below and form the foundation for the proposed research.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Hybrid Tandem Photovoltaics

Tandem solar cell structures are the only strategy demonstrated to surpass the detailed balance efficiency limit of high-quality single-junction solar cells. To continue to improve the efficiencies of cost-effective terrestrial solar power, hybrid tandems of dissimilar subcells are being considered by many around the world, especially designs that incorporate silicon solar cells as a bottom subcell. In this project, we studied a wide variety of tandem design possibilities including those with three-terminal (3T) and four-terminal (4T) configurations. The use of 3T and 4T designs could be useful for efficient and economical hybrid tandem designs that utilize the best available subcell materials such as emerging perovskite materials. Three-terminal configurations, in particular, have not been sufficiently studied previously. We have laid the foundational groundwork in this project for understanding the operation of 3T tandems: developing a taxonomy for naming, a methodology for measuring and interconnecting, and models for simply characterizing 3T tandems. Electrical and optical subcell coupling between the subcells was also measured and modeled. An important part of this work was the fabrication of novel example tandem structures, including 4T GaAs/Si, 3T GaInP/Si, 3T GaAs/Si, and 3T GaInP/GaAs devices. Using these high-quality tandem cells, we have been able to clearly demonstrate the achievability of high-efficiencies, and subtle physical effects such as photon recycling and luminescent coupling. We have developed and demonstrated essential building-block tools such as transparent conductive adhesives (TCA) and 3T silicon bottom cells with interdigitated back contacts (IBC) that can also be used in many other tandem designs. We have tested the reliability of these tools and devices under standardized testing and outdoor measurements. We have found 4T GaAs/Si tandems to be relatively straightforward to fabricate and robust in real-world outdoor conditions. While we have demonstrated working hybrid 3T III-V/TCA/Si IBC tandems, we experienced low yields even with our best process flows yet. Further work is still needed to improve the processing yield of these devices. We therefore also created tandem cells using an all-III-V 3T tandem process which was very robust with high yields, allowing for the creation of voltage-matched strings in many different configurations using 8 nearly identical 3T tandems. Using these robust 3T tandem examples, we were able measure and precisely characterize 3T tandem behaviors to predict their operation under changing spectrum and temperature. The optoelectronic equivalent-circuit model was shown to be very general and applicable to hybrid tandems, and encompassed the operation 3T Si IBC cells. This general model has been distributed to the public in as open-source Python-based software called PVcircuit. We have calculated the implications of these new tandem device designs on the real-world energy production and shown how the relative performance of different tandem configurations is situational and can be engineered using the tools developed here.

14 SOLAR ENERGY↗

Effects of gamma, electron beam, and X-ray irradiation on the plastic components of a universal bone cement mixer medical device

Due to market and regulatory pressures, many healthcare manufacturers are considering alternatives to cobalt-60 gamma radiation, including accelerator-based electron beam (E-beam) and X-ray radiation for product sterilization. In this work, the effects of irradiation on a representative medical product, comprised of eight distinct polymer materials, were directly compared for three radiation technologies – cobalt-60 gamma, E-beam, and X-ray – at four dose levels (15, 25, 50, and 70 kGy). The objective was to determine how radiation effects (deleterious or beneficial) are influenced by source and dose level, with the specific goal of determining whether E-beam radiation and/or X-ray radiation could be viable alternatives to gamma radiation for device sterilization. Here, the specific product considered is a single-use medical device for orthopedic surgery, the Stryker Instruments MixeVac III bone cement mixer, which is currently sterilized using gamma radiation from cobalt-60 sources. Following ASTM International standards and input from the manufacturer, we characterized the effects of the three radiation sources on product functionality as well as on the mechanical and optical properties of the constituent polymers. Results indicate that although measurable differences in properties between the standard gamma irradiated materials and the alternative E-beam and X-ray irradiated materials were observed, those differences were small. Statistically significant differences were noted in the case of yellowness index for polyvinyl chloride, high-density polyethylene, and polycarbonate, and in the case of tensile elongation at break for high impact polystyrene and polyvinyl chloride. In general, the results of this study support the viability of E-beam and X-ray radiation as alternative options to cobalt-60 gamma radiation for sterilization of Stryker single-use universal bone cement mixer medical devices.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Mechanisms for long carrier lifetime in Cd(Se)Te double heterostructures

II–VI semiconductors are used in numerous electro-optical applications. For example, CdTe-based solar technology is cost competitive with other electricity generation sources, yet there is still significant room to improve. Carrier lifetime has historically been well below the radiative recombination limit. Lifetimes reaching beyond 100 ns can significantly enhance performance and enable novel device structures. Here, double heterostructures (DHs) with passivated interfaces demonstrate lifetimes exceeding 1 µs, yet this appears only for CdSeTe and not for CdTe DHs. We compare the passivation mechanisms in CdTe and CdSeTe DHs. CdSeTe lifetimes on the order of 1 µs correspond to a combination of superior intragrain lifetime, extremely low grain boundary recombination and greater Te4+ interfacial presence compared to CdTe.

36 MATERIALS SCIENCE↗

Fiber-optic bolometer with low detection limit fabricated using thermal release tape and precise laser heating

Fiber-optic bolometers (FOBs) based on a fiber-tipped silicon Fabry–Perot (FP) interferometric temperature sensor and a gold disk absorber have been shown to be an attractive alternative to conventional resistive bolometers for plasma radiation measurement in fusion devices. Either a high-finesse FP or a low-finesse FP can be used, each with trade-offs between noise performance and fabrication complexity. In this paper, we present an FOB design that overcomes these limitations by combining a low-finesse long silicon FP cavity with a large gold disk absorber to achieve enhanced sensitivity and noise performance without increasing the fabrication complexity and the time constant. We also demonstrated a fabrication method for the sensor head facilitated by thermal release tape and precise laser heating. Our FOB demonstrates a temperature resolution of 0.08 mK, a cooling time constant of 230 ms, and a noise equivalent power density of 0.015 W m −2 . This represents an eightfold improvement over previous high-finesse FOBs and 26-fold improvement over previous low-finesse FOBs with similar demodulation bandwidths and similar cooling time constants.

Fabry–Perot interferometer↗

Filament Formation in TaO x Thin Films for Memristor Device Application: Modeling Electron Energy Loss Spectra and Electron Transport

Abstract Although understanding filament formation in oxide‐based memristive devices by theory has emerged, there are still fundamental unanswered questions. Importantly, for practical application of thin films the material in its amorphous state is to be considered, but mostly lacking so far, and details on sub‐stoichiometry are also scarce. To gain insight into the optical and electronic properties of sub‐stoichiometric amorphous tantalum oxide (TaO x ), the electron energy loss spectrum (EELS) of model systems is characterized theoretically and electron transport characteristics are analyzed in detail. Calculated blue‐shifts by increasing sub‐stoichiometry explained the measurements, potentially suggesting estimation of oxygen vacancy concentrations through EEL spectra. Electron transport results based on TaO x material models validated by EELS measurements show that oxygen vacancy filamentary paths are initiated at low bias upon increasing sub‐stoichiometry yet noting an interplay with the local amorphous structure. Contact resistances at interfaces of the TaO x switching layer and a tantalum scavenging layer or titanium nitride electrode are quantified, indicating the possibility for either oxygen vacancy‐ or metal cluster‐based conduction mechanisms at the interface. The computational work, combined with experimental characterization for validation, provides a basis for investigating effects of sub‐stoichiometry on filament formation in TaO x thin film memristive devices.

36 MATERIALS SCIENCE↗

Floquet engineering of strongly driven excitons in monolayer tungsten disulfide

Interactions of quantum materials with strong-laser fields can induce exotic nonequilibrium electronic states. Monolayer transition-metal dichalcogenides, a new class of direct-gap semiconductors with prominent quantum confinement, offer exceptional opportunities toward Floquet engineering of quasiparticle electron-hole states, or excitons. Strong-field driving has a potential to achieve enhanced control of electronic band structure, thus a possibility to open a new realm of exciton light-matter interactions. However, experimental implementation of strongly-driven excitons has so far remained out of reach. Here, we use mid-infrared laser pulses below the optical bandgap to excite monolayer tungsten disulfide up to a field strength of 0.3 V/nm, and demonstrate strong-field light dressing of excitons in the excess of a hundred millielectronvolt. Our high-sensitivity transient absorption spectroscopy further reveals formation of a virtual absorption feature below the 1s-exciton resonance, which is assigned to a light-dressed sideband from the dark 2p-exciton state. Quantum-mechanical simulations substantiate the experimental results and enable us to retrieve real-space movies of the exciton dynamics. Here, this study advances our understanding of the exciton dynamics in the strong-field regime, and showcases the possibility of harnessing ultrafast, strong-field phenomena in device applications of two-dimensional materials.

36 MATERIALS SCIENCE↗

Tissue-mimicking phantoms for performance evaluation of photoacoustic microscopy systems

Phantom-based performance test methods are critically needed to support development and clinical translation of emerging photoacoustic microscopy (PAM) devices. While phantoms have been recently developed for macroscopic photoacoustic imaging systems, there is an unmet need for well-characterized tissue-mimicking materials (TMMs) and phantoms suitable for evaluating PAM systems. Our objective was to develop and characterize a suitable dermis-mimicking TMM based on polyacrylamide hydrogels and demonstrate its utility for constructing image quality phantoms. TMM formulations were optically characterized over 400–1100 nm using integrating sphere spectrophotometry and acoustically characterized using a pulse through-transmission method over 8–24 MHz with highly confident extrapolation throughout the usable band of the PAM system. This TMM was used to construct a spatial resolution phantom containing gold nanoparticle point targets and a penetration depth phantom containing slanted tungsten filaments and blood-filled tubes. These phantoms were used to characterize performance of a custom-built PAM system. The TMM was found to be broadly tunable and specific formulations were identified to mimic human dermis at an optical wavelength of 570 nm and acoustic frequencies of 10–50 MHz. Imaging results showed that tungsten filaments yielded 1.1–4.2 times greater apparent maximum imaging depth than blood-filled tubes, which may overestimate real-world performance for vascular imaging applications. Nanoparticles were detectable only to depths of 120–200 µm, which may be due to the relatively weaker absorption of single nanoparticles vs. larger targets containing high concentration of hemoglobin. The developed TMMs and phantoms are useful tools to support PAM device characterization and optimization, streamline regulatory decision-making, and accelerate clinical translation.

Hsu, Hsun-Chia↗