Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Optical Imaging”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,153 records · Page 64

Deletion of Cdkn1a in Mice Rescues Reduced Osteogenesis in Microgravity and Increases Coupled Osteoclastic Bone Degenerative Activity and Bone Loss

Elevated Cdkn1a/p21 levels in mouse bone during spaceflight have led us to hypothesize that this cell cycle inhibitor could regulate osteogenesis in response to mechanical unloading in microgravity. Cdkn1a interacts with cyclins CDK1/2/4,6 during G1 and S phases, and suppression of its expression by mechanical stretch enhances proliferation and mineralization in osteoblastic cell cultures. To test this hypothesis in a whole-organism model, we used C57BL/J6 WT/Cdkn1a-null mice in the NASA RR-10, 30-day ISS microgravity experiment. To quantify active mineralization in microgravity mice were injected with Calcein seven and two days before euthanasia on-orbit, followed by high-resolution confocal imaging of optically cleared femoral endosteal surfaces. To quantify cortical and cancellous bone parameters we conducted microCT analyses of the femur and tibia. Confocal imaging revealed a population of mineralizing calcein-positive single osteoblasts, and multicellular surfaces of mineralization by osteocytes in lacunae. The Cdkn1a-null genotype shows a greater ratio of early-osteoblasts to late-osteocytes and reduced mineralization versus WT. Additionally, in microgravity WT bones have a large (80%) decrease in active mineralization, but remarkably Cdkn1a deletion fully rescued mineralized surface loss. MicroCT shows trends for moderate spaceflight bone loss in WT femurs, and significant losses in the tibia, while Cdkn1a-null femurs showed much larger significant tissue losses, including 25% thinner trabeculae (p < 0.01),40% thinner cortical bone (p < 0.005), and 10% lower percent cortical bone area (p < 0.05). These results indicate that endogenous bone Cdkn1a plays a key role in mechanosensitive downregulation of osteoprecursor proliferation and promotes osteocytic differentiation. In microgravity however, while Cdkn1a deletion rescues mineralization, bone loss quantified by microCT is greatly increased, likely due to the molecular coupling of osteogenesis and osteoclastogenesis. This molecular mechanism opens the possibility for potential pharmacological approaches to mitigate bone loss in space simultaneously targeting Cdkn1a and osteoclast inhibition.

Eduardo A.C. Almeida↗

Fast quantum ghost imaging with a single-photon-sensitive time-stamping camera

Quantum ghost imaging (QGI) leverages correlations between entangled photon pairs to reconstruct an image using light that has never physically interacted with an object. Despite extensive research interest, this technique has long been hindered by slow acquisition speeds, due to the use of raster-scanned detectors or the slow response of intensified cameras. Here, we utilize a single-photon-sensitive time-stamping camera to perform QGI at ultra-low-light levels with rapid data acquisition and processing times, achieving high-resolution and high-contrast images in under 1 min. Our work addresses the trade-off between image quality, optical power, data acquisition time, and data processing time in QGI, paving the way for practical applications in biomedical and quantum-secured imaging.

Mavian, Alex (ORCID:0000000279448830)↗

X-ray Irradiance Distribution for an Interferometer with a Curved Biprism Array

The development of interferometry-based X-ray phase contrast imaging systems that provide highly resolved X-rays with spatially-modulated intensity is enabling the full potential of X-ray optics to image phase, attenuation, and small angle scatter properties of soft tissue. In this work we present analytical formulations of a new hardware concept for X-ray phase contrast imaging wherein the phase grating is replaced with an array of Fresnel biprisms. We derive expressions for the irradiance distribution pattern of a biprism interferometer composed of a curved biprism array with multiple biprisms and multiple point sources. These expressions are used to plot fringe patterns for X-ray design parameters, including 1) size, number, and period of X-ray point sources; 2) biprism parameters of material composition, angle, number, and period; and 3) biprism array to X-ray source and detector distances. Analytical results show that the biprism interferometer provides a longitudinally-nonperiodic pattern of spatially modulated intensity different from the Talbot longitudinally-periodic pattern common in grating interferometry. The curvature of the biprism array brings a sharper longitudinal fringe pattern. Experiments are being performed to verify the analytical calculations for a biprism plastic material of SU-8 using a synchrotron source. X-ray biprism material has widely varied indexes of refraction relative to wavelength and thus the separation of the virtual sources and resulting interference fringe period also varies with X-ray wavelength. Our aim is to develop biprism interferometry imaging systems with excellent polychromatic performance that produce high-contrast fringes with spatially incoherent X-ray illumination. Biprism interferometry will potentially provide higher fringe visibility with better image quality to that of diffraction grating interferometry.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Design, Fabrication and Testing of Multilayer Coated X-Ray Optics for the Water Window Imaging X-Ray Microscope

Hoover et. al. built and tested two imaging Schwarzschild multilayer microscopes. These instruments were constructed as prototypes for the "Water Window Imaging X-Ray Microscope," which is a doubly reflecting, multilayer x-ray microscope configured to operate within the "water window." The "water window" is the narrow region of the x-ray spectrum between the K absorption edges of oxygen (lamda = 23.3 Angstroms) and of carbon (lamda = 43.62 Angstroms), where water is relatively highly transmissive and carbon is highly absorptive. This property of these materials, thus permits the use of high resolution multilayer x-ray microscopes for producing high contrast images of carbon-based structures within the aqueous physiological environments of living cells. We report the design, fabrication and testing of multilayer optics that operate in this regime.

Spencer, Dwight C.↗

Asteroid Shape Reconstruction From Radar Observations

I estimate near-Earth asteroid 1992 SK's physical properties from radar delay-Doppler images, Doppler-only echo spectra and optical lightcurves. The images are not very strong, but place up to 20 (40 m by 160 m) pixels on the asteroid. The radar tracks are confined to subradar latitudes between 20 and 40 degrees but have complete rotational phase coverage. The echo spectra and optical lightcurves span approx.80 degrees of sky motion, providing geometric leverage to constrain the pole direction. The optical lightcurves are essential to accurate determination of the asteroid's shape and spin state. The asteroid is approx.1.4 km in maximum extent and mildly asymmetric, with an elongation of approx.1.5 and relatively subdued topography. The radar albedo is about 0.13 and the optical albedo about 0.3. The circular polarization ratio for the object is about 0.34, implying typical cm-scale surface roughness. I estimate the asteroid's period to be 7.3182+/-0.0003 hours and its pole direction as (99deg+/-5deg,-3deg+/-5deg) in ecliptic coordinates. The radar-refined orbital solution accurately predicts planetary close approaches between the years 826 and 2690. I have used my model to predict salient characteristics of radar images and optical lightcurves obtainable during the asteroid's March 2006 approach.

Busch, Michael J.↗

Imaging performance of annular apertures. VI - Limitations by optical surface deviations

The performance of optical systems is limited by imperfect optical surfaces that degrade the images below the level set by wave theoretical limits. The central irradiance functions are derived for slit and circular apertures with five distributions of wavefront errors and for a range of maximal wavefront deviations. For practical frequency of occurrence distributions of wavefront deviations, the point spread and the image energy integral functions are determined. Practical performances of optical systems are derived and performance limits discussed.

Tschunko, Hubert F. A.↗

Architectures and algorithms for digital image processing; Proceedings of the Meeting, Cannes, France, December 5, 6, 1985

The conference presents papers on the architectures, algorithms, and applications of image processing. Particular attention is given to a very large scale integration system for image reconstruction from projections, a prebuffer algorithm for instant display of volume data, and an adaptive image sequence filtering scheme based on motion detection. Papers are also presented on a simple, direct practical method of sensing local motion and analyzing local optical flow, image matching techniques, and an automated biological dosimetry system.

Duff, Michael J. B.↗

Dosimetry of heavy ions by use of CCD detectors

The design and the atomic composition of Charge Coupled Devices (CCD's) make them unique for investigations of single energetic particle events. As detector system for ionizing particles they detect single particles with local resolution and near real time particle tracking. In combination with its properties as optical sensor, particle transversals of single particles are to be correlated to any objects attached to the light sensitive surface of the sensor by simple imaging of their shadow and subsequent image analysis of both, optical image and particle effects, observed in affected pixels. With biological objects it is possible for the first time to investigate effects of single heavy ions in tissue or extinguished organs of metabolizing (i.e. moving) systems with a local resolution better than 15 microns. Calibration data for particle detection in CCD's are presented for low energetic protons and heavy ions.

Schott, J. U.↗

Experimental Validation of a Neuro-Fuzzy Approach to Phasing the SIBOA Segmented Mirror Testbed

NASA is preparing to launch the Next Generation Space Telescope (NGST). This telescope will be larger than the Hubble Space Telescope, be launched on an Atlas missile rather than the Space Shuttle, have a segmented primary mirror, and be placed in a higher orbit. All these differences pose significant challenges. This effort addresses the challenge of aligning the segments of the primary mirror during the initial deployment. The segments need to piston values aligned to within one tenth of a wavelength. The present study considers using a neuro-fuzzy model of the Fraunhofer diffraction theory. The intention of the current study was to experimentally verify the algorithm derived earlier. The experimental study was to be performed on the SIBOA (Systematic Image Based Optical Alignment) test bed. Unfortunately the hardware/software for SIBOA was not ready by the end of the study period. We did succeed in capturing several images of two stacked segments with various relative phases. These images can be used to calibrate the algorithm for future implementation. This effort is a continuation of prior work. The basic effort involves developing a closed loop control algorithm to phase a segmented mirror test bed (SIBOA). The control algorithm is based on a neuro-fuzzy model of SIBOA and incorporates nonlinear observers built from observer banks. This effort involves implementing the algorithm on the SIBOA test bed.

Philip D. Olivier↗

Folded Optical Design for High Fidelity Atmospheric Emulation With A Spatial Light Modulator

Atmospheric emulators based on spatial light modulators offer the ability to test atmospheric propagation effects on a laser communication component’s performance in the laboratory setting. To create a high-fidelity atmospheric emulator, details of the optical design are key. This paper discusses the optical design choices and refinements that enabled the creation of a system that was verified to recreate multi-layer turbulence with high fidelity up to D/r 0 =50. Optical design choices that affect the fidelity discussed in this paper include the characteristics of the input laser, the spatial light modulator, the holograms, the image relay optical components, and the spatial filter. Also included in this paper is a comparison of the chosen folded optical layout to an alternative angled layout.

Atmospheric turbulence↗

Folded Optical Design for High Fidelity Atmospheric Emulation With A Spatial Light Modulator

Atmospheric emulators based on spatial light modulators offer the ability to test atmospheric propagation effects on a laser communication component’s performance in the laboratory setting. To create a high-fidelity atmospheric emulator, details of the optical design are key. This paper discusses the optical design choices and refinements that enabled the creation of a system that was verified to recreate multi-layer turbulence with high fidelity up to D/r0 =50. Optical design choices that affect the fidelity discussed in this paper include the characteristics of the input laser, the spatial light modulator, the holograms, the image relay optical components, and the spatial filter. Also included in this paper is a comparison of the chosen folded optical layout to an alternative angled layout.

Atmospheric turbulence↗

Fast widefield imaging of neuronal structure and function with optical sectioning in vivo

Optical microscopy, owing to its noninvasiveness and subcellular resolution, enables in vivo visualization of neuronal structure and function in the physiological context. Optical-sectioning structured illumination microscopy (OS-SIM) is a widefield fluorescence imaging technique that uses structured illumination patterns to encode in-focus structures and optically sections 3D samples. However, its application to in vivo imaging has been limited. In this study, we optimized OS-SIM for in vivo neural imaging. We modified OS-SIM reconstruction algorithms to improve signal-to-noise ratio and correct motion-induced artifacts in live samples. Incorporating an adaptive optics (AO) module to OS-SIM, we found that correcting sample-induced optical aberrations was essential for achieving accurate structural and functional characterizations in vivo. With AO OS-SIM, we demonstrated fast, high-resolution in vivo imaging with optical sectioning for structural imaging of mouse cortical neurons and zebrafish larval motor neurons, and functional imaging of quantal synaptic transmission at Drosophila larval neuromuscular junctions.

42 ENGINEERING↗

Satellite-To-Satellite Imaging in Support of LEO Optical Navigation, Using the ASTERIA Cubesat

The Arcsecond Space Telescope Enabling Research in Astrophysics (ASTERIA) was a 6-unit CubeSat technology demonstration mission that was built at NASA’s Jet Propulsion Laboratory (JPL) and deployed from the International Space Station (ISS) on November 20th, 2017. After successfully completing its 90-day primary mission that demonstrated arcsecond-level line-of-sight pointing and focal plane thermal stability for exoplanet detection, it entered an extended mission performing onboard software demonstrations alongside science until end of mission in December 2019. At the end of its lifetime it was being used as a demonstration platform for several experiments, including low earth orbit (LEO) optical navigation operations. With its visible light astrometric camera and stable attitude control system, the ASTERIA spacecraft showed itself to be a capable platform for the imaging of geosynchronous satellites from LEO. This paper will describe the imagery attained in flight and also the image processing algorithms that were developed to render that imagery into navigation quality data. These algorithms dealt with hot pixel filtering, noise modeling, attitude registration, star signal rejection and satellite signal identification. Brightness prediction algorithms used for target selection will also be discussed.

Fesq, Lorraine↗

SSG SiC Optical Systems in Space

Silicon Carbide (SiC) materials provide a number of benefits for space based optical systems. SSG Precision Optronics has extensive experience in the areas of design, fabrication, integration, and test of SiC optical systems. This expertise has been applied to produce a number of SiC-based instruments, including the Miniature Infrared Camera and Spectrometer (MICAS) and Advanced Land Imager (ALI) optical systems which have flown as part of NASA's New Millennium program. Our presentation will provide an overview of SSG's experience in the development of these SiC flight systems.

Robichaud, Joseph↗

Visible and Infrared Imaging of Various Flow Regimes in the Flow Boiling and Condensation Experiment Transfer Line

The Flow Boiling and Condensation Experiment (FBCE) Transfer Line (TL) test module is being developed to study fluid physics of cryogenic transfer lines in microgravity. The TL module will reside in the FBCE facility located within the Fluids Integration Rack (FIR) aboard the International Space Station (ISS). TL will use the same normal perfluoro hexane (nPFH) used in the previous FBCE test sections. To simulate cryogenic line transfer in the visualization section, a sapphire tube coated with indium tin oxide (ITO) is heated via Joule heated while a bypass line is used to flow liquid nPFH at the desired inlet conditions. Once the visualization line reaches steady-state temperature and pressure conditions, flow is diverted through the heated line and chilldown begins. All flow regimes observed within a cryogenic TL are created and studied using visible imaging with diffuse backlighting to image inverted annular flow, transition, and nucleate boiling. A visible laser light sheet provided by FIR will provide a means to observe and track droplets in the dispersed flow regime. IR imaging of the visualization tube outer surface with the emissivity of the ITO coating provides the surface chilldown temperature profile. Preliminary imaging system development includes some of the components used in the Flow Boiling Module (FBM) and some new components that are easily integrated into the PC-based system but will require some refinement to operate properly on the FIR PCIe/104 imaging system. Optical design and packaging within the limited volume of the module enclosure is also presented. This paper presents FBCE-TL visible and infrared laboratory-based imaging studies and anticipated visualization capabilities of the TL module under preliminary breadboard development and under the utilization constraints within the FBCE/FIR host facility.

transfer line↗

Fresnel zone plate point spread function approximation for zeroth order mitigation in millimetric field of view x-ray imaging

High spatial and temporal resolution x-ray radiography images are required at the National Ignition Facility (NIF) for high-energy density experiments. One technique that is in development to achieve the required resolution uses Fresnel zone plate (FZP) optics to image an object that is backlit by an x-ray source. The multiple FZP diffraction orders do not focus on the same plane, which increases the background and reduces the contrast. Understanding the point spread function of the different diffraction orders will allow the prediction of the expected background using simulations. We find that the two-dimensional point spread function of the FZP can be approximated by the addition of a sharp Gaussian with a disk. This allowed for the estimation of the background in NIF experimental images of Rayleigh–Taylor spikes and their interpretation. An alternative design of FZP is discussed to allow the inclusion of a zeroth order blocker to reduce the background.

Do, A. (ORCID:0000000174372147)↗

The fast camera (Fastcam) imaging diagnostic systems on the DIII-D tokamak

Two camera systems are installed on the DIII-D tokamak at the toroidal positions of 90° (90° system) and 225° (225° system), respectively. The cameras have two types of relay optics, namely, a coherent optical fiber bundle and a periscope system. The periscope system provides absolute intensity calibration stability while sacrificing resolution (10 lp/mm), while the fiber system provides high resolution (16 lp/mm) while sacrificing calibration stability. The periscope is available only for the 90° system. The optics of the 225° system were designed for view stability, repeatability, and easy maintenance. The cameras are located inside optimized neutron, x ray and magnetic shielding in order to reduce electronics damage, reboots, and magnetic and neutron interference, increasing the overall system reliability. An automated filter wheel, providing remote filter change, allows for remote wavelength selection. A software suite automates camera acquisition and data storage, allowing for remote operation and reduced operator involvement. System metadata is used to streamline the data analysis workflow, particularly for intensity calibration. Here, the spatial calibration uses multiple observable wall features, resulting in a reconstruction accuracy ≤2 cm.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗