Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Operational reliability”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,153 records · Page 64

Fossil fleet transition with fuel changes and large scale variable renewable integration

Variability in demand as seen by grid-connected dispatchable generators can increase due to factors such as greater production from variable generation assets (for example, wind and solar), increased reliance on demand response or customer-driven automation, and aggregation of loads. This variability results a need for these generators to operate in a range of different modes, collectively referred to as “flexible operations.” This study is designed to inform power companies, researchers, and policymakers of the scope and trends in increasing levels of flexible operations as well as reliability challenges and impacts for dispatchable assets. Background Because there is rarely a direct monetization of the value of operational flexibility, the decision to provide such flexibility is typically dependent on unit- and region-specific decisions made by asset owners. It is very likely that much greater and more widespread flexible operations capabilities will be needed due to increased variability in demand seen by grid-connected generators, uncertainty regarding investment in new units to provide adequate operational flexibility, and the retirement of older, uncontrolled sub-critical pulverized coal units. Objective To enhance understanding of the technical challenges and operational impacts associated with dispatchable assets needed to increase operational flexibility and support variable demand. Approach The study approach consists of three elements: a literature review of relevant prior studies, analysis of detailed scenarios for evolution of the future fleet over the next 35 years, and engineering assessment of the degree and scope of technical challenges associated with transformation to the future fleet. The study approach integrated two key elements rarely brought together in a single analysis—1) long-term capacity planning, which enables modeling of unit retirements and new asset investments, and 2) unit commitment analysis, which permits examination of hourly unit dispatch while considering operational limitations relevant to flexible operations capabilities.

James, Revis↗

Power System Waveform Datasets for Machine Learning

The desire for increased visibility across the electricity grid will necessarily increase the deployment of sensing and measurement devices and associated data management needs to unprecedented levels. For the existing sensing and measurement infrastructure, there remains a great amount of “value” yet to be extracted through advanced data management and analytics. Availability of more data will not, by itself, lead to changes in grid visibility, security, and resiliency. To create the predictive and prescriptive environment required to enable new markets and transactions for customer revenue and a reliable grid, the data must be collected, organized, evaluated, and analyzed using sophisticated algorithms to provide actionable information allowing operators and customers to reliably manage an increasingly complex grid. Progress in artificial intelligence (AI) has been largely driven by large, publicly available datasets that can be used to train AI algorithms such as MNIST, a database of handwritten images of digits, and ImageNet, an image database of everyday objects. These types of publicly available databases of real-world training datasets have been largely credited for advancement of image processing, computer vision, and deep learning algorithms that these use cases deploy. However, in the power systems industry to date, there are few databases with proper event labeling, and data access to a publicly available collection of power system event waveforms that will allow users to interact with grid signature data. Publicly available datasets of power system event waveforms, such as the DOE/EPRI dataset, often lack critical metadata or contain limited examples of each event type, and data formats vary widely across these datasets.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Enhanced Component Performance Study: Air-Operated Valves 1998-2014

This report presents a performance evaluation of air-operated valves (AOVs) at U.S. commercial nuclear power plants. The data used in this study are based on the operating experience failure reports from fiscal year 1998 through 2014 for the component reliability as reported in the Institute of Nuclear Power Operations (INPO) Consolidated Events Database (ICES). The AOV failure modes considered are failure-to-open/close, failure to operate or control, and spurious operation. The component reliability estimates and the reliability data are trended for the most recent 10-year period, while yearly estimates for reliability are provided for the entire active period. One statistically significant trend was observed in the AOV data: The frequency of demands per reactor year for valves recording the fail-to-open or fail-to-close failure modes, for high-demand valves (those with greater than twenty demands per year), was found to be decreasing. The decrease was about three percent over the ten year period trended.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Geometry Optimization for Structural Reliability and Performance of a Thermoelectric Generator

The opposing requirements for the performance and reliability of a thermoelectric generator (TEG) are investigated with numerical finite element analysis simulations. The parameters that significantly influence the operational performance and structural reliability of a TEG are considered for simultaneous optimization. The design of experiments (DOE) based response surface optimization methodology in conjunction with results from finite element analysis was employed to identify optimal parameters from the structural reliability and performance (power output and efficiency) perspectives. A high temperature bismuth telluride based TEG couple was used in the studies to demonstrate the general applicability of the methodology. The response surface methodology is found to be a robust technique that can expedite the process of geometry optimization of a TE device during the research and development phase of TEG devices fabricated from new thermoelectric materials.

Karri, Naveen K.↗

Pilot plant reliability metrics for grinding and fast pyrolysis of woody residues

Here we report on the effects of loblolly pine residue variability on material throughput, pilot plant uptime, operator intervention, product yield, and product quality for grinding, fast pyrolysis, and hydrotreating operations. Preprocessing throughput using a hammer mill varied between 31-48% of nameplate capacity (5 tons/hr). Grinder overloads in the size reduction step were more prevalent for lower ash and higher moisture materials. Fast pyrolysis throughput varied between 57-72% of nameplate capacity (20 kg/hr) and bio-oil yields varied between 46-53% (feedstock carbon to oil, dry basis). During fast pyrolysis operations, downtime was caused by bridging in the feed and char removal systems and plugging in the condensation system. Cohesion of feedstock and char leading to system plugging was less frequent for higher ash feedstocks, and differences in condenser plugging behavior between high and low ash feedstocks were observed. The catalyst stability of the bio-oil stabilization step was strongly dependent on the sulfur content in the bio-oil, which was higher for the high-ash residue oils. Lower moisture content in the starting biomass was consistent with lower sulfur content in bio-oil. Yields and properties of hydrotreated fuel products showed minimal deference among the bio-oils.

Klinger, Jordan↗

Emerging Trends and Systemic Issues Influencing Today’s U.S. Electric Grid

With increasing shifts from vertically integrated to horizontally structured operations and from centralized to distributed electric power delivery, today’s electric power grid (the “grid”) operators and designers face the challenge of creating an architecture that accommodates a host of diverse requirements. The grid’s modes of operation must address concerns of reliability and stability, new deployments of renewable energy sources, threats from cyber-attacks and natural disasters, and increasingly distributed system operations. Grid modernization calls for a reliable, affordable, sustainable, agile, secure, and resilient grid. However, the modernization of the U.S. power grid is hampered by mounting complexity and diverging objectives from owners and operators and is consequently risky and fraught with potential missteps. Flawed architecture, design, and implementation will lead to stranded investments and lost opportunities. A principled approach to minimize risk and develop a robust grid of the future is to begin with a sound architecture for the grid to inform the design process. Architecture development starts with the context of influencing factors that provide constraints as well as driving goals. This report provides the context of emerging trends and cross-cutting systemic issues in the U.S. electric power grid and serves as a vital input for grid architecture development.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Methodology for Exploring Water and Hydropower Operating Criteria That Simultaneously Improve Economic and Environmental Considerations

Despite the reliability and flexibility of hydropower, the operation of hydroelectric power plants may have significant impacts on the downstream river system, including its water stage, sediment transport, and water temperature, ultimately affecting the ecology. To address these challenges, there is a need to identify water scheduling patterns that improve both hydropower economics and the environment relative to current operations. This paper presents a new methodology to explore promising operational criteria/rules that can achieve such improvements. Typical environmental impact statements and relicensing processes generally perform detailed site-specific analyses of a few alternatives that focus on reservoir water release operating rules and their associated environmental impacts. In contrast, the methodology presented in this article uses a widely applicable approach that explores a much larger solution space. This large set of potential alternatives can be represented in a multidimensional space for which one axis represents the economic value and the other axis quantify individual environmental impacts (e.g., sediment transport and fish growth), and they are explored via two approaches: a Monte Carlo simulation that identifies “win–win” alternatives and a multi-objective optimization problem that identifies Pareto-optimal alternatives.

13 HYDRO ENERGY↗

Progress on Advancing Robotic Ultrasonic Volumetric Inspection Technology for Hanford Under-tank Inspection - 19474

The Hanford River Protection Project is reliant on safe interim storage of high-level waste at the Hanford site and will continue to depend on it until the waste has been treated and vitrified by the Hanford Waste Treatment and Immobilization Plant (WTP). The Hanford double-shell tanks (DSTs) have provided interim storage since the DSTs were put into service (1971 - 1986) and the RPP will continue to rely on their service until least 2050, at which time the 27 in-service DSTs will be 14-54 years beyond their original design lives. As the DSTs continue to age and be operated beyond design life, reliable leak integrity assessments of primary tanks and secondary liners will become increasingly important in order to provide situational awareness to tank operations personnel and to support risk-informed decisions on the selection of DSTs as waste feed staging tanks and the order and timing of future DST refurbishment or, alternatively, DST retrieval sequence. This paper summarizes progress made in fiscal year (FY) 2018 on the engineering of a robotic air-slot volumetric inspection system (RAVIS) that is designed to perform ultrasonic (volumetric) leak integrity inspections of physically inaccessible primary tank bottom plates and welds. Leak integrity inspections performed with the RAVIS will supplement today's primary tank leak integrity inspections, which are currently limited to physically accessible sidewall plates and welds. The RAVIS will be deployed into air slots of the insulating concrete (refractory) pad beneath the primary tanks and use its ultrasonic guided wave phased-array (GWPA) sensor to electronically steer an ultrasonic beam 360-degrees around the sensor to volumetrically examine adjacent carbon steel plates and welds covered by refractory pad material. Deployments of RAVIS down multiple air-slots will be performed to determine which regions of a tank bottom have sound leak integrity or which regions are in need of future wall thickness restoration or weld repair due to pitting corrosion, general corrosion, or heat/stress-induced cracks. The initial RAVIS design and the flaw detection test results for the first air-slot GWPA sensor that was designed to fit inside the air-slots will be presented in this paper. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Hierarchical, Grid-Aware, and Economically Optimal Coordination of Distributed Energy Resources in Realistic Distribution Systems

Renewable portfolio standards are targeting high levels of variable solar photovoltaics (PV) in electric distribution systems, which makes reliability more challenging to maintain for distribution system operators (DSOs). Distributed energy resources (DERs), including smart, connected appliances and PV inverters, represent responsive grid resources that can provide flexibility to support the DSO in actively managing their networks to facilitate reliability under extreme levels of solar PV. This flexibility can also be used to optimize system operations with respect to economic signals from wholesale energy and ancillary service markets. Here, we present a novel hierarchical scheme that actively controls behind-the-meter DERs to reliably manage each unbalanced distribution feeder and exploits the available flexibility to ensure reliable operation and economically optimizes the entire distribution network. Each layer of the scheme employs advanced optimization methods at different timescales to ensure that the system operates within both grid and device limits. The hierarchy is validated in a large-scale realistic simulation based on data from the industry. Simulation results show that coordination of flexibility improves both system reliability and economics, and enables greater penetration of solar PV. Discussion is also provided on the practical viability of the required communications and controls to implement the presented scheme within a large DSO.

distribution network↗

Universal Utility Data Exchange (UUDEX) – Security and Administration: Cybersecurity of Energy Delivery Systems (CEDS) Research and Development

A critical component of the Universal Utility Data Exchange (UUDEX) approach is the integrated security contained within its processing. This document describes how that security is designed and expected to be implemented by UUDEX Implementations (U-Implementations), including the UUDEX Server (U-Server) and UUDEX Clients (U-Clients). The UUDEX security hierarchy consists of three levels: 1. The UUDEX Instance (U-Instance) itself, which sits at the top of the hierarchy and contains the U-Server, the UUDEX Identity Authority (U-Identity Authority), and the UUDEX Administrator (U-Administrator) functions; 2. A group of one or more UUDEX Participants (U-Participants) that present “organizations” that participate in the U-Instance and contains the UUDEX Administrator Participant (U-U-Administrator Participant) function; 3. A group of one or more UUDEX Endpoints (U-Endpoints) that represent the individual UUDEX Publish Clients (U-Publish Client) responsible for supplying data to the U-Instance that is consumed by UUDEX Subscriber Clients (U-Subscriber Clients). U-Endpoints can be either autonomous devices that publish and subscribe data such as data exchange servers found in supervisory control and data acquisition and energy management systems, or they can be tied to users of applications that, for example, submit DOE OE-417 disturbance reports. U-Participants and U-Endpoints can be organized into UUDEX Groups (U-Groups). Any number of U-Participants or U-Endpoints can be members of a U-Group. A given U-Participant or U-Endpoint can be a member of multiple U-Groups, but a U-Group cannot contain other U-Groups. For example, a U-Group could be created to contain all U-Participant Transmission Operators within the purview of a Reliability Coordinator, and another U-Group could be created to contain all U-Participant Generator Operators within the purview of a Reliability Coordinator. U-Participants that are both Transmission Operators and Generator Operators would be members of both U-Groups. U-Participants, U-Endpoints, and U-Groups are used in the access control structures to provide access to individual UUDEX Subjects (U-Subjects). U-Groups are created by the U-Administrator and are managed by the U-Administrator or the designated U-Group Managers. U-Endpoints can be assigned UUDEX Roles (U-Roles) that can be used to further restrict access. U-Roles are assigned to individual U-Endpoints. For example, a U-Role of “Security Analyst” could be used to restrict which U-Endpoints can publish or subscribe security incident reports and vulnerability notifications, while a U-Role of “Transmission Planner” can be used to restrict which U-Endpoints can publish power system model updates. U-Role definitions are created by the U-Administrator, but the U-Roles are assigned to U-Endpoints by their respective UUDEX Participant Administrators (U-Participant Administrator). Because all information required to make security decisions is either included within the U-Endpoint’s X.509 digital certificate or stored in a datastore on the U-Server, all security decisions are performed and enforced within the U-Server. This reduces the complexity of the U-Client code and minimizes the chance for compromise of the integrity of the UUDEX security features.

97 MATHEMATICS AND COMPUTING↗

Crossing the Finish Line: Integration of Data-Driven Process Control for Maximization of Energy and Resource Efficiency in Advanced Water Resource Recovery Facilities

Improvements in process monitoring and control at water resource recovery facilities (WRRFs) could result in reductions in electricity consumption, chemical inputs, and greenhouse gas emissions, as well as improved energy recovery. Many current WRRF data collection, monitoring, and control approaches use 20th century process monitoring and control systems, which require large design safety factors to ensure reliability in the absence of more advanced, precise controls. Implementation of more modern data-driven control tools could lead to more efficient operations that provide intrinsic reliability with better overall process performance at full-scale. This presentation provides an overview of a recently initiated project "Crossing the Finish Line: Integration of Data-Driven Process Control for Maximization of Energy and Resource Efficiency in Advanced Water Resource Recovery Facilities" which will (1) develop and demonstrate data-driven process controls at full-scale facilities for five promising WRRF Applications (i.e., process technologies) that provide whole-plant approaches and offer substantial energy and resource recovery benefits, and (2) create a toolbox of new process control approaches and an implementation guide including five examples for application at utilities. The presentation also provides a detailed overview of the research approach and progress being made on one of the five Applications, namely Application 2: Biological Nutrient Removal (BNR): ammonium-based aeration control (ABAC) / ammonia vs. NOx (AvN) + partial denitration with anammox (PdNA), which is being implemented at Hampton Roads Sanitation District. This project is a collaboration of work being conducted by DC Water, Hampton Roads Sanitation District, Metro Water Recovery, University of Michigan, Northwestern University, US Military Academy - West Point, Black & Veatch, and Oak Ridge National Laboratory. Research partner: U.S. Department of Energy.

54 ENVIRONMENTAL SCIENCES↗

Crossing the Finish Line: Integration of Data-Driven Process Control for Maximization of Energy and Resource Efficiency in Advanced Water Resource Recovery Facilities

Improvements in process monitoring and control at water resource recovery facilities (WRRFs) could result in reductions in electricity consumption, chemical inputs, and greenhouse gas emissions, as well as improved energy recovery. Many current WRRF data collection, monitoring, and control approaches use 20th century process monitoring and control systems, which require large design safety factors to ensure reliability in the absence of more advanced, precise controls. Implementation of more modern data-driven control tools could lead to more efficient operations that provide intrinsic reliability with better overall process performance at full-scale. This project (1) developed and demonstrated data-driven process controls at full-scale facilities for five promising WRRF process technologies that provide whole-plant approaches and offer substantial energy and resource recovery benefits, and (2) created a Machine Learning (ML) Toolkit and an implementation guide of new process control approaches that walks users through each step of the ML workflow and illustrates the steps through case study examples.

54 ENVIRONMENTAL SCIENCES↗

Improving Nuclear System Economics using Firebrick Resistance-Heated Energy Storage (FIRES)

As the electricity grid continues to implement unstable and intermittent energy resources in place of conventional dispatchable fuels, highly responsive energy storage systems will become an essential part of grid operation, to assure grid reliability, and reconcile electricity supply and demand. FIRES coupled with high-temperature heat systems such as NACC or industrial furnace enables different operating modes capable of yielding economic advantages to those who make the investment in storage, while also bringing relief to the grid by responding to the highly variable supply caused by wind and solar installations: In the case of the industrial furnace, by varying its own demand, while in the case of the FHR, by switching from a large supplier of electricity to a large consumer at times of low electricity prices. It should also benefit base-load nuclear plants by eliminating very low electricity prices as seen in some areas of the U.S. with significant installed wind or solar capacity—while lowering greenhouse gas emissions.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

A hybrid surrogate modeling framework for the Digital Twin of a Fluoride-salt-cooled High-temperature Reactor (FHR)

While nuclear energy is a non-greenhouse-gas emitting energy source, expensive operational costs due to the high-level of safety requirements decreases their competitiveness in the sustainable energy market. Advanced reactor concepts paired with Digital Twins aim to increase the commercialization gains of nuclear energy by reducing operational costs, increasing reactor reliability and enhancing power generation. To support Digital Twin tasks such as real-time autonomous control, proactive maintenance monitoring or optimizing power demand operations, a fast and accurate virtual representation of the Nuclear Power Plant (NPP) is required. The computational cost of high-fidelity, physics-based models are unsuitable for real-time analysis or scalability. Here, in this work, a hybrid surrogate modeling framework is developed fora Fluoride-salt-cooled High-temperature Reactor (FHR) that leverages physics-inspired models for key reactor components and uses data-driven methods for rapid system state space prediction. The Xenon reactivity feedback model is integrated to inform the surrogate model about the reactor core and the homologous pump theory model is the basis for representing pump degradation. Using a detailed, two dimensional thermal hydraulics model to generate data on the FHR, we train a network of Vectorized Autoregressive Moving-Average with eXogenous input (VARMAX) models to predict the remaining state values. The result is a surrogate model that provides a detailed reactor state representation of 41 system states and a pump degradation analysis. The framework is applied to Load Follows profiles, yielding high accuracy and a speedup that is more than 4000x faster compared to the higher- fidelity thermal hydraulics model, enabling real-time operational intelligence and applications in long horizon predictions. While the surrogate model framework is demonstrated for the particular case of FHR, the hybrid physical/data-driven modeling approach including the network of surrogates and the underlying modularity has the potential to be applied to other physical asset systems.

Digital Twins↗

Perceived Uncertainty Sources in Wind Power Plant Design

This presentation for the Fourth Wind Energy Systems Engineering Workshop covers some of the uncertainties that still impact turbulent wind operation and how these affect design and structural reliability; identifies key sources and prioritization for R and D; and summarizes an analysis of current procedures, industry best practice, standards, and expert opinions.

17 WIND ENERGY↗

Transient Stability Study of a Real-World Microgrid with 100% Renewables: Preprint

This paper performs a transient stability study of a real-world microgrid with 100% renewables to fully understand the stability and reliability of the microgrid under various dynamic scenarios. In particular, the operation of multiple grid-forming (GFM) and grid-following (GFL) inverters in such a power system is not well understood under dynamic operation conditions, such as islanding and black start; therefore, in this paper, the full-scale electromagnetic transient modeling of the microgrid is developed to investigate the stability of the system under various dynamic operating conditions and to identify potential reliability risks. The PSCAD/EMTDC simulation with the high-fidelity model provides helpful insights into the optimal operation modes of GFM and GFL inverters as well as the stability and reliability of the microgrid, which gives good references for the field deployment in terms of inverter configuration and coordination as well as the capabilities of black start and unplanned islanding.

100% renewable microgrid↗

Digitalization Guiding Principles and Method for Nuclear Industry Work Processes

The commercial U.S. light-water reactor fleet has been operating at historical efficiency, reliability, and safety over the last decade. Nuclear power has the highest capacity factor of any other power generation technology while also serving as the largest baseload source for carbon-free energy. Despite this remarkable achievement, continued operations for many plants are threatened due to fierce electricity market competition and rising operations and maintenance costs of which continued maintenance of obsolete analog equipment is a contributor. The digital age and associated technologies are where the future lies in process control, and nuclear has yet to take full advantage of the capabilities offered therein. The Light Water Reactor Sustainability Program (LWRS) at Idaho National Laboratory (INL), sponsored by the Department of Energy, has a mission to help the light-water reactor fleet manage its foundational capabilities to continue providing safe and reliable carbon-free power. LWRS helps support that mission by providing scientific, technology-based solutions for advanced concepts of operations with a more viable business model that will allow the fleet to continue to operate at peak levels through extended plant operation. The LWRS Digitalization Project at INL seeks to leverage digital technologies to synthesize and transform work processes. We provide a state-of-the-art analysis of digitalized work processes in nuclear power and investigate ways in which researchers at INL and the nuclear industry can work together to identify what data to access, how to access it, what to do with the data, and most importantly, how to use the insights for decision-making across all levels within the business. Borne from these considerations, we present four guiding principles for digitalization: develop a coherent digitalization plan, apply human factors engineering, establish data governance, and anticipate unintended consequences. Together, these principles form a method that plants can use to effectively to digitalize nuclear industry work processes. Our guiding principles are informed by multiple knowledge sources. First, we document activities from the Work Digitalization Initiative, which was conceived as a means for nuclear organizations to help define and standardize the industry’s approach to digitalizing work. Second, we detail primary research conducted with industry professionals regarding drivers and barriers to digitalization adoption. We present survey results that demonstrate what the industry hopes to get out of digitalization and the ways that INL can continue to support the industry’s digital transformation. Third, we present a digitalization use case with industry partners NextAxiom Technology and Xcel Energy. The project objective was to transform the current condition report work process from paper to digital, incorporating digitalized principles. We report the development of the application and lessons learned. The accomplishments achieved by this research and development serve to identify critical needs for plant guidance in support of digitalization implementation and contribute to the knowledge and strategies available for utilities considering or undertaking digitalization.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗