Lifetime requirements for semiconductor lasers in inertial fusion energy systems
Explore the source record for details and available documents.
SEARCH · Engineering Papers
Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.
Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.
Explore the source record for details and available documents.
Explore the source record for details and available documents.
Explore the source record for details and available documents.
Explore the source record for details and available documents.
Explore the source record for details and available documents.
Explore the source record for details and available documents.
Explore the source record for details and available documents.
Modeling & Simulation (M&S) tools are used to analyze advanced reactor designs and the safety of current nuclear operations. As computers continue to improve, we are able to enhance resolution in our calculations. Therefore, the limitations of simulation capability are in the quality of data that is being used, including our ability to quantify the uncertainty and sensitivity of that data. In order to model systems of interest with increasing accuracy, the industry must improve key nuclear data measurements. The International Criticality Safety Benchmark Evaluation Project (ICSBEP) compiles and evaluates experiment data in a handbook that can be used by criticality safety engineers and others to validate computer codes and cross section libraries at nuclear facilities. Both critical and subcritical experiments are included in the handbook. These experiments, along with differential measurements, can help improve the quality of nuclear data. Concerns regarding the accuracy of Cu nuclear data have been published. The large values and trend of C-E for the Zeus intermediate energy benchmark, being one of the primary examples. Furthermore, very few experiments have been designed to be sensitive to Cu (as shown in Figure 1), so an integral, critical experiment is needed to help resolve these differences.
Explore the source record for details and available documents.
Explore the source record for details and available documents.
Explore the source record for details and available documents.
Explore the source record for details and available documents.
A collection of x-ray computed tomography scans of specimens from the Denver Museum of Nature & Science.
Existing COTS inorganic scintillators all have the characteristic of being very good at certain desirable properties, but not sufficient at other desirable properties for HEP. The demand for suitable scintillators (with regards to both scintillation detector properties and suitable pricing), to be used for modern intensities frontier (Mu2e-II), energy frontier (High luminosity large hadron collider) and future e+e- collider projects (aimed as Higgs bosons factory, such as the International Linear Collider (ILC) and the Future Circular Collider (FCC) are putting even higher challenges on crystal scintillators.In this work, we report the development of a novel high-performance scintillators that can address the issues associated with existing scintillators, the activator doped Hg2Br2. Initial results are very encouraging on the detection of gamma and alpha particles using a solid-state photomultiplier (SSPM). The responses have been stable and repeatable. Hg2Br2 also has many advantages over existing COTS scintillators such as: high density, bright, fast, good energy resolution, no intrinsic radiation, radiation hard and cost-effectiveness. Here, we present here why Hg2Br2 is the next generation scintillator for high energy physics experiments as well as other scientific and imaging applications such as planetary science and medical imaging.
Abstract Flexible electronic skin with features that include sensing, processing, and responding to stimuli have transformed human–robot interactions. However, more advanced capabilities, such as human‐like self‐protection modalities with a sense of pain, sign of injury, and healing, are more challenging. Herein, a novel, flexible, and robust diffusive memristor based on a copolymer of chlorotrifluoroethylene and vinylidene fluoride (FK‐800) as an artificial nociceptor (pain sensor) is reported. Devices composed of Ag/FK‐800/Pt have outstanding switching endurance >10 6 cycles, orders of magnitude higher than any other two‐terminal polymer/organic memristors in literature (typically 10 2 –10 3 cycles). In situ conductive atomic force microscopy is employed to dynamically switch individual filaments, which demonstrates that conductive filaments correlate with polymer grain boundaries and FK‐800 has superior morphological stability under repeated switching cycles. It is hypothesized that the high thermal stability and high elasticity of FK‐800 contribute to the stability under local Joule heating associated with electrical switching. To mimic biological nociceptors, four signature nociceptive characteristics are demonstrated: threshold triggering, no adaptation, relaxation, and sensitization. Lastly, by integrating a triboelectric generator (artificial mechanoreceptor), memristor (artificial nociceptor), and light emitting diode (artificial bruise), the first bioinspired injury response system capable of sensing pain, showing signs of injury, and healing, is demonstrated.
The Source Term Analysis of Xenon (STAX) project has been installing stack detectors at medical isotope production facilities to measure radioxenon emissions to investigate the effect of radioxenon releases on nuclear explosion monitoring. This paper outlines the installation of the first STAX detection system at the National Institute for Radioelements (IRE) in Fleurus, Belgium which has been operating for over three years and transferring collected data to the STAX repository. Information about the equipment installed, the data flow established, and calculations for determination of radioxenon releases from the facility are presented. Further. data quality was investigated to confirm values reported by STAX automated data processing and in a comparison of collected STAX data with data collected by IRE for regulatory reporting.
The ability to differentiate between atmospheric radionuclide signatures from underground nuclear explosions (UNEs) and signals from other sources, such as medical isotope-production facilities and nuclear reactors, can be critical to the detection and monitoring of unannounced, low-yield nuclear events. Signatures having anomalously high amplitudes, compared to background levels, remain the best indicator in screening for a UNE. However, isotopic composition can further validate a suspected UNE signature, but separation from any atmospheric background composition is first necessary. To date, evaluating the challenges of performing this separation has typically involved comparing an observed background with a highly idealized deterministic model of radioxenon signature production by a UNE that does not consider the influence of post-detonation chemical/physical processes in the detonation cavity or the subsequent gas transport mechanisms that can also affect the isotopic composition of the detected gas signature. In addition, purely deterministic models, as previously employed, overlook the uncertainty inherent in estimating critical parameters characterizing the UNE and its detonation environment. In this paper, we create detailed, multi-parameter models of radionuclide evolution using the widely accepted England and Rider post-detonation radionuclide decay-chain network coupled to detailed models simulating physical production and transport processes affecting the gas signature. Because these models are governed by uncertain parameters including barometric fluctuations, realistic ranges of variation for each of the parameters influencing isotopic composition are then defined. A Latin-Hypercube sampling approach is used to obtain a random distribution of isotopic production and gas transport results associated with a given value of each parameter. We apply these results to background histories of two stations, one providing 4-isotope background measurements and the other providing two-isotope measurements associated with the 2013 DPRK announced UNE.