Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Microscope and microscopy.”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,153 records · Page 64

Microscopic Manipulation of Ferroelectric Domains in SnSe Monolayers at Room Temperature

Two-dimensional (2D) van der Waals ferroelectrics provide an unprecedented architectural freedom for the creation of artificial multiferroics and nonvolatile electronic devices based on vertical and coplanar heterojunctions of 2D ferroic materials. Nevertheless, controlled microscopic manipulation of ferroelectric domains is still rare in monolayer-thick 2D ferroelectrics with in-plane polarization. Here we report the discovery of robust ferroelectricity with a critical temperature close to 400 K in SnSe monolayer plates grown on graphene and the demonstration of controlled room-temperature ferroelectric domain manipulation by applying appropriate bias voltage pulses to the tip of a scanning tunneling microscope (STM). This study shows that STM is a powerful tool for detecting and manipulating the microscopic domain structures in 2D ferroelectric monolayers, which are difficult for conventional approaches such as piezoresponse force microscopy, thus facilitating the hunt for other 2D ferroelectric monolayers with in-plane polarization with important technological applications.

2D ferroelectric↗

Key role of lattice symmetry in the metal-insulator transition of NdNiO 3 films

Here, bulk NdNiO 3 exhibits a metal-to-insulator transition (MIT) as the temperature is lowered that is also seen in tensile strained films. In contrast, films that are under a large compressive strain typically remain metallic at all temperatures. To clarify the microscopic origins of this behavior, we use position averaged convergent beam electron diffraction in scanning transmission electron microscopy to characterize strained NdNiO 3 films both above and below the MIT temperature. We show that a symmetry lowering structural change takes place in case of the tensile strained film, which undergoes an MIT, but is absent in the compressively strained film. Using space group symmetry arguments, we show that these results support the bond length disproportionation model of the MIT in the rare-earth nickelates. Furthermore, the results provide insights into the non-Fermi liquid phase that is observed in films for which the MIT is absent.

36 MATERIALS SCIENCE↗

Improved performance by morphology control via fullerenes in PBDT-TBT-alkoBT based organic solar cells

In this work, we report improved performance by controlling morphology using different fullerene derivatives in poly{2-octyldodecyloxy-benzo[1,2-b;3,4-b]dithiophene-alt-5,6-bis(dodecyloxy)-4,7- di(thieno[3,2-b]thiophen-2-yl)-benzo[c][1,2,5]thiadiazole} (PBDT-TBT-alkoBT) based organic solar cells. PC60BM and PC70BM fullerenes were used to investigate the characteristic change in morphology and device performance. Fullerene affects device efficiency by changing active layer morphology. PC70BM with broader absorption than PC 60 BM resulted in reduced device performance which was elucidated by the intermixed granular morphology separating each larger grain in the PC70BM/polymer composite layer which created higher density of traps. However after adding additive 1,8-diiodooctane (DIO), the fibrous morphology was observed due to reduced solubility of polymer and increased solubility of PC 70 BM in chloroform. The fibrous morphology improved charge transport leading to increase in overall device performance. Atomic force microscopies (AFM), photo induced charge extraction by linearly increasing voltage (photo-CELIV), and Kelvin prove force microscope (KPFM) were used to investigate nanoscale morphology of active layer with different fullerene derivatives. For PC 60 BM based active layer, AFM images revealed dense fibrous morphology and more distinct fibrous morphology was observed by adding DIO. The PC 70 BM based active layer only exhibited intermixed granular morphology instead of fibrous morphology observed in PC60BM based active layer. However, addition of DIO in PC 70 BM based active layer led to fibrous morphology. When additive DIO was not used, a wider distribution of surface potential was observed for PC 70 BM than PC 60 BM based active layer by KPFM measurements, indicating 2 polymer and fullerene domains are separated. When DIO was used, narrower distribution of surface potential for both PC 70 BM and PC 60 BM based active layers was observed. Photo-CELIV experiment showed larger extracted charge carrier density and mobility in PC 70 BM/DIO film.

14 SOLAR ENERGY↗

Epitaxial growth and structural analysis of AlN/GaN heterostructures

Single crystal AlN thin films were epitaxially grown on GaN/sapphire (0001) substrates on a macroscopic scale by magnetron sputtering. The microscopic structure and orientation degree of the AlN epilayers were studied by high-resolution transmission electron microscopy, high-resolution x-ray diffraction, and reciprocal spacing mapping. It was revealed that the AlN epilayers have high in-plane and out-of-plane orientation degrees and low defect density. The electrical and optical properties of the AlN epilayers were also studied, and the results suggest that the AlN epilayers grown by sputtering may be employed in the fabrication of GaN-based light-emitting diode devices with increased efficiency.

36 MATERIALS SCIENCE↗

Opto-mechano-electrical tripling in ZnO nanowires probed by photocurrent spectroscopy in a high-resolution transmission electron microscope

Photocurrent spectroscopy of individual free-standing ZnO nanowires inside a high-resolution transmission electron microscope (TEM) is reported. By using specially designed optical in situ TEM system capable of scanning tunneling microscopy probing paired with light illumination, opto-mechano-electrical tripling phenomenon in ZnO nanowires is demonstrated. Splitting of photocurrent spectra at around 3.3 eV under in situ TEM bending of ZnO nanowires directly corresponds to nanowire deformation and appearance of expanded and compressed nanowire sides. Theoretical simulation of a bent ZnO nanowire has an excellent agreement with the experimental data. The splitting effect could be explained by a change in the valence band structure of ZnO nanowires due to a lattice strain. The strain-induced splitting provides important clues for future flexible piezo-phototronics.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Rapid, antibiotic incubation-free determination of tuberculosis drug resistance using machine learning and Raman spectroscopy

Tuberculosis (TB) is the world’s deadliest infectious disease, with over 1.5 million deaths and 10 million new cases reported anually. The causative organism Mycobacterium tuberculosis (Mtb) can take nearly 40 d to culture, a required step to determine the pathogen’s antibiotic susceptibility. Both rapid identification and rapid antibiotic susceptibility testing of Mtb are essential for effective patient treatment and combating antimicrobial resistance. Here, we demonstrate a rapid, culture-free, and antibiotic incubation-free drug susceptibility test for TB using Raman spectroscopy and machine learning. We collect few-to-single-cell Raman spectra from over 25,000 cells of the Mtb complex strain Bacillus Calmette-Guérin (BCG) resistant to one of the four mainstay anti-TB drugs, isoniazid, rifampicin, moxifloxacin, and amikacin, as well as a pan-susceptible wildtype strain. By training a neural network on this data, we classify the antibiotic resistance profile of each strain, both on dried samples and on patient sputum samples. On dried samples, we achieve >98% resistant versus susceptible classification accuracy across all five BCG strains. In patient sputum samples, we achieve ~79% average classification accuracy. We develop a feature recognition algorithm in order to verify that our machine learning model is using biologically relevant spectral features to assess the resistance profiles of our mycobacterial strains. Finally, we demonstrate how this approach can be deployed in resource-limited settings by developing a low-cost, portable Raman microscope that costs <$5,000. We show how this instrument and our machine learning model enable combined microscopy and spectroscopy for accurate few-to-single-cell drug susceptibility testing of BCG.

60 APPLIED LIFE SCIENCES↗

VitroJet: new features and case studies

Single-particle cryo-electron microscopy has become a widely adopted method in structural biology due to many recent technological advances in microscopes, detectors and image processing. Before being able to inspect a biological sample in an electron microscope, it needs to be deposited in a thin layer on a grid and rapidly frozen. The VitroJet was designed with this aim, as well as avoiding the delicate manual handling and transfer steps that occur during the conventional grid-preparation process. Since its creation, numerous technical developments have resulted in a device that is now widely utilized in multiple laboratories worldwide. It features plasma treatment, low-volume sample deposition through pin printing, optical ice-thickness measurement and cryofixation of pre-clipped Autogrids through jet vitrification. This paper presents recent technical improvements to the VitroJet and the benefits that it brings to the cryo-EM workflow. A wide variety of applications are shown: membrane proteins, nucleosomes, fatty-acid synthase, Tobacco mosaic virus, lipid nanoparticles, tick-borne encephalitis viruses and bacteriophages. These case studies illustrate the advancement of the VitroJet into an instrument that enables accurate control and reproducibility, demonstrating its suitability for time-efficient cryo-EM structure determination.

59 BASIC BIOLOGICAL SCIENCES↗

Real-time Studies of Battery Electrochemical Reactions Inside a Transmission Electron Microscope

We report the development of new experimental capabilities and ab initio modeling for real-time studies of Li-ion battery electrochemical reactions. We developed three capabilities for in-situ transmission electron microscopy (TEM) studies: a capability that uses a nanomanipulator inside the TEM to assemble electrochemical cells with ionic liquid or solid state electrolytes, a capability that uses on-chip assembly of battery components on to TEM-compatible multi-electrode arrays, and a capability that uses a TEM-compatible sealed electrochemical cell that we developed for performing in-situ TEM using volatile battery electrolytes. These capabilities were used to understand lithiation mechanisms in nanoscale battery materials, including SnO 2 , Si, Ge, Al, ZnO, and MnO 2 . The modeling approaches used ab initio molecular dynamics to understand early stages of ethylene carbonate reduction on lithiated-graphite and lithium surfaces and constrained density functional theory to understand ethylene carbonate reduction on passivated electrode surfaces.

25 ENERGY STORAGE↗

Electron microscopy analysis of crystalline silicon islands formed on screen-printed aluminum-doped p-type silicon surfaces

The origin of a not yet understood concentration peak, which is generally measured at the surface of aluminum-doped p{sup +} regions produced in a conventional screen-printing process is investigated. Our findings provide clear experimental evidence that the concentration peak is due to the microscopic structures formed at the silicon surface during the firing process. To characterize the microscopic nature of the islands (lateral dimensions of 1-3 {mu}m) and line networks of self-assembled nanostructures (lateral dimension of {<=}50 nm), transmission electron microscopy, scanning electron microscopy, scanning transmission electron microscopy, and energy dispersive x-ray analysis are combined. Aluminum inclusions are detected 50 nm below the surface of the islands and crystalline aluminum precipitates of {<=}7 nm in diameter are found within the bulk of the islands. In addition, aluminum inclusions (lateral dimension of {approx}30 nm) are found within the bulk of the self-assembled line networks.

36 MATERIALS SCIENCE↗

The extended wedge method: Atomic force microscope friction calibration for improved tolerance to instrument misalignments, tip offset, and blunt probes

One of the major challenges in understanding and controlling friction is the difficulty in bridging the length and time scales of macroscale contacts and those of the single asperity interactions they comprise. While the atomic force microscope (AFM) offers a unique ability to probe tribological surfaces in a wear-free single-asperity contact, instrument calibration challenges have limited the usefulness of this technique for quantitative nanotribological studies. A number of lateral force calibration techniques have been proposed and used, but none has gained universal acceptance due to practical considerations, configuration limitations, or sensitivities to unknowable error sources. This paper describes a simple extension of the classic wedge method of AFM lateral force calibration which: (1) allows simultaneous calibration and measurement on any substrate, thus eliminating prior tip damage and confounding effects of instrument setup adjustments; (2) is insensitive to adhesion, PSD cross-talk, transducer/piezo-tube axis misalignment, and shear-center offset; (3) is applicable to integrated tips and colloidal probes; and (4) is generally applicable to any reciprocating friction coefficient measurement. The method was applied to AFM measurements of polished carbon (99.999% graphite) and single crystal MoS{sub 2} to demonstrate the technique. Carbon and single crystal MoS{sub 2} had friction coefficients of {mu}= 0.20 {+-} 0.04 and {mu}= 0.006 {+-} 0.001, respectively, against an integrated Si probe. Against a glass colloidal sphere, MoS{sub 2} had a friction coefficient of {mu}= 0.005 {+-} 0.001. Generally, the measurement uncertainties ranged from 10%-20% and were driven by the effect of actual frictional variation on the calibration rather than calibration error itself (i.e., due to misalignment, tip-offset, or probe radius).

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

In situ sputter cleaning of thin film metal substrates for UHV-TEM corrosion studies.

A prerequisite for conducting valid corrosion experiments by in situ electron microscopy techniques is not only the achievement of UHV background pressure conditions at the site of the specimen but also the ability to clean the surface of the thin metal substrate specimen before initiation of the corrosive interaction. A miniaturized simple ion gun has been constructed for this purpose. The gun is small enough to be incorporated into an UHV electron microscope specimen chamber with hot stage in such a way as to permit bombardment of the substrate specimen while observing it by transmission electron microscopy TEM. It is shown that the ion beam generated is confined well enough to cause a sputtering removal of substrate material at a rate of approximately 5-10 A/min and to prevent the sputter deposition of contaminating material from the specimen holder.

Heinemann, K.↗

The effect of grain boundary character evolution on the intergranular corrosion behavior of advanced Al-Mg-3wt%Zn alloy with Mg variation

Highlights: • The relationship among GBCD, GBPs, IGC behavior and Mg content in the age hardenable Al-Mg-3.0wt%Zn alloy is established. • None of grain boundaries are found to be immune to the GBPs. • GBPs along low angle grain boundaries are more discontinuous than high angle grain boundaries. • The IGC mechanism of Al-Mg-3.0wt%Zn alloy is clarified. • A new method for the statistical analysis of the continuity of GBPs is used in this paper. The characteristics of grain boundary and grain boundary precipitates of Al-Mg-3wt%Zn alloy with different Mg contents were systematically investigated. Observation by optical microscopy, transmission electron microscopy, scanning transmission electron microscopy and energy-dispersive X-ray spectroscopy show that the morphology and composition of the grain boundary precipitates change little with the variation in the Mg content. Based on the statistical analysis of the spacings between two adjacent grain boundary precipitates, we find that the decrease in the Mg content reduces the continuity of the grain boundary precipitates. Comparing this result with the electron backscattered diffraction analysis, it can be concluded that the continuity of grain boundary precipitates is affected by the proportion of low angle grain boundaries. The observations of grain boundary precipitates at both low angle grain boundaries and high angle grain boundaries using transmission electron microscopy indicate that low angle grain boundaries have more discontinuous grain boundary precipitates. Combining these results with the results of the intergranular corrosion test, the microscopic features of this corrosion behavior and corrosion mechanism are revealed.

36 MATERIALS SCIENCE↗

Automated Energy-Dispersive X-ray Spectroscopy Analysis for Multi-Modal Few-Shot Learning

Scanning transmission electron microscopy (STEM) is a powerful tool that allows for the atomic-scale analysis of a materials’ structure, chemistry, and defect domains (Akers et al. 2021). The current generation of microscopes generate vast amounts of data, surpassing the limits of effective manual analysis traditionally performed by domain experts (Spurgeon et al. 2021). While recent strides in machine learning have significantly enhanced the processing of large and intricate datasets acquired through electron microscopy, the prevalent use of proprietary software packages for initial data collection poses a challenge. In many cases, these software packages act as a ‘black box’, constraining user functionality and hindering the output of data in a format that is conducive to seamless integration into machine learning models. This work addresses these challenges by adapting HyperSpy, an open-source Python library, for the analysis and quantification of raw energy dispersive spectroscopy (EDS) data acquired through STEM. The modified HyperSpy code successfully facilitates user-defined segmentation of the data, enabling the integration of atomic %, weight %, and raw EDS spectra for each segmented region into an existing few-shot machine learning model. While initial results reveal discrepancies in quantified atomic and weight percentages when compared to proprietary software, ongoing efforts aim to rectify this issue by refining the fit of the HyperSpy model to the EDS spectra. Overall, this research underscores the potential of open-source tools like HyperSpy to enhance the accessibility of analytical tools, fostering a transparent and user-friendly environment for seamlessly incorporating electron microscopy data into machine learning models.

36 MATERIALS SCIENCE↗

Material identification in x-ray microscopy and micro CT using multi-layer, multi-color scintillation detectors

We demonstrate that a dual-layer, dual-color scintillator construct for microscopic CT, originally proposed to increase sensitivity in synchrotron imaging, can also be used to perform material quantification and classification when coupled with polychromatic illumination. We consider two different approaches to data handling: (1) a data-domain material decomposition whose estimation performance can be characterized by the Cramer-Rao lower bound formalism but which requires careful calibration and (2) an image-domain material classification approach that is more robust to calibration errors. The data-domain analysis indicates that useful levels of SNR (>5) could be achieved in one second or less at typical bending magnet fluxes for relatively large amounts of contrast (several mm path length, such as in a fluid flow experiment) and at typical undulator fluxes for small amount of contrast (tens of microns path length, such as an angiography experiment). The tools introduced could of course be used to study and optimize parameters for a wider range of potential applications. The image domain approach was analyzed in terms of its ability to distinguish different elemental stains by characterizing the angle between the lines traced out in a two-dimensional space of effective attenuation coefficient in the front and back layer images. As a result, this approach was implemented at a synchrotron and the results were consistent with simulation predictions.

36 MATERIALS SCIENCE↗

Data reduction of digitized images processed from calibrated photographic and spectroscopic films obtained from terrestial, rocket and space shuttle telescopic instruments

The Microvax 2 computer, the basic software in VMS, and the Mitsubishi High Speed Disk were received and installed. The digital scanning tunneling microscope is fully installed and operational. A new technique was developed for pseudocolor analysis of the line plot images of a scanning tunneling microscope. Computer studies and mathematical modeling of the empirical data associated with many of the film calibration studies were presented. A gas can follow-up experiment which will be launched in September, on the Space Shuttle STS-50, was prepared and loaded. Papers were presented on the structure of the human hair strand using scanning electron microscopy and x ray analysis and updated research on the annual rings produced by the surf clam of the ocean estuaries of Maryland. Scanning electron microscopic work was conducted by the research team for the study of the Mossbauer and Magnetic Susceptibility Studies on NmNi(4.25)Fe(.85) and its Hydride.

Hammond, Ernest C., Jr.↗

Magnetization Reversal of Permalloy Microparticles with the Configuration Anisotropy by Magnetic-Force Microscopy

Abstract—Magnetic force microscopy has been used to study the distribution of the magnetization in permalloy microparticles with a configurational anisotropy. The triangular particles with different degrees of concavity of the lateral sides have been studied. An analysis of the results enables us to state that the particles can be in several quasi-homogeneous stable states. It is shown that the particle magnetization reversal can occur both stepwise and also via an intermediate state in the dependence on the particle orientation. It is demonstrated that the quasi-homogeneous magnetization orientation in a particle can be changed by a magnetic-force microscope probe.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Modeling of contact theories for the manipulation of biological micro/nanoparticles in the form of circular crowned rollers based on the atomic force microscope

This article has dealt with the development and modeling of various contact theories for biological nanoparticles shaped as cylinders and circular crowned rollers for application in the manipulation of different biological micro/nanoparticles based on Atomic Force Microscope. First, the effective contact forces were simulated, and their impact on contact mechanics simulation was investigated. In the next step, the Hertz contact model was simulated and compared for gold and DNA nanoparticles with the three types of spherical, cylindrical, and circular crowned roller type contact geometries. Then by reducing the length of the cylindrical section in the circular crowned roller geometry, the geometry of the body was made to approach that of a sphere, and the results were compared for DNA nanoparticles. To anticipatory validate the developed theories, the results of the cylindrical and the circular crowned roller contacts were compared with the results of the existing spherical contact simulations. Following the development of these contact models for the manipulation of various biological micro/nanoparticles, the cylindrical and the circular crowned roller type contact theories were modeled based on the theories of Lundberg, Dowson, Nikpur, Heoprich, and Hertz for the manipulation of biological micro/nanoparticles. Then, for a more accurate validation, the results obtained from the simulations were compared with those obtained by the finite element method and with the experimental results available in previous articles. The previous research works on the simulation of nanomanipulation have mainly investigated the contact theories used in the manipulation of spherical micro/nanoparticles. However since in real biomanipulation situations, biological micro/nanoparticles of more complex shapes need to be displaced in biological environments, this article therefore has modeled and compared, for the first time, different contact theories for use in the biomanipulation of cylindrical and circular crowned roller shaped micro/nanoparticles. The results of models indicate that the contact model of Hertz achieves the largest amount of deformation for the DNA nanoparticle in cylindrical form and the contact model of Heoprich achieves the largest deformation for the circular crowned roller shaped DNA. Of course, this finding is not always true for the other nanoparticles; and considering the mechanical and environmental characteristics, different results can be obtained. Also, by comparing the deformations of different types of nanoparticles, it was determined that the platelet type nanoparticles display the highest degree of deformation in all the considered models, due to their particular mechanical characteristics.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Dual harmonic Kelvin probe force microscopy at the graphene–liquid interface

Kelvin probe force microscopy (KPFM) is a powerful technique for the determination of the contact potential difference (CPD) between an atomic force microscope tip and a sample under ambient and vacuum conditions. However, for many energy storage and conversion systems, including graphene-based electrochemical capacitors, understanding electrochemical phenomena at the solid–liquid interface is paramount. Despite the vast potential to provide fundamental insight for energy storage materials at the nanoscale, KPFM has found limited applicability in liquid environments to date. Here, using dual harmonic (DH)-KPFM, we demonstrate CPD imaging of graphene in liquid. We find good agreement with measurements performed in air, highlighting the potential of DH-KPFM to probe electrochemistry at the graphene–liquid interface.

36 MATERIALS SCIENCE↗