Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Metering”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,153 records · Page 64

An ampere-hour meter for batteries

Up-down counter records charge as well as discharge in tests of rechargeable batteries. System uses reversible counter preset to represent 100% charge. As battery discharges, total count decreases; as battery is recharged, counter moves back to 100% indication.

Eklund, B. D.↗

Meter circuit for tuning RF amplifiers

Circuit computes and indicates efficiency of RF amplifier as inputs and other parameters are varied. Voltage drop across internal resistance of ammeter is amplified by operational amplifier and applied to one multiplier input. Other input is obtained through two resistors from positive terminal of power supply.

Longthorne, J. E.↗

Overall and blade-element performance of a transonic compressor stage with multiple-circular-arc blades at tip speed of 419 meters per second

A 50-centimeter-diameter axial-flow transonic compressor stage with multiple-circular-arc blades was designed and tested to study the effects of blade shape on efficiency and stall margin. At design speed, peak efficiency of 0.80 occurred at an equivalent weight flow of 29.0 kilograms per second. Measured total pressure ratio and total temperature ratio at peak efficiency were 1.69 and 1.20, respectively. The stall margin at design speed and an equivalent weight flow of 29.0 kilograms per second was 9 percent. The measured stall margin at design weight flow and speed was 15 percent. A comparison of rotor performance made with and without the stator showed a decrease in pressure ratio, peak efficiency, and maximum weight flow with the addition of the stator.

Kovich, G.↗

NASA/JPL deep space network 64 meter diameter antenna dual frequency feed system

To support the Mariner 1973 X-band experiment, it was necessary to implement a dual-frequency microwave feed system for the Cassegrainian-fed DSS 14 64-m antenna. This system must be capable of simultaneous low noise reception at S- and X-bands and high power transmission at S-band. The design and measured perfromance of the DSS 14 reflex feed system is described.

Potter, P. D.↗

Reactivity change in a fast-spectrum space power reactor due to a 328-meter-per-second (1075-ft/sec) impact

Application of nuclear reactors in space will present operational problems. One such problem is the possibility of an earth impact at velocities in excess of 305 m/sec (1000 ft/sec). This report shows the results of an impact against concrete at 328 m/sec (1075 ft/sec) and examines the deformed core to estimate the range of activity inserted as a result of the impact. The results of this examination are that the deformation of the reactor core within the containment vessel left only an estimated 2.7 percent void in the core and that the reactivity inserted due to this impact deformation could be from 4.0 to 10.25 dollars.

Peoples, J. A., Jr.↗

Apollo 15 measurement of lunar surface brightness temperatures - Thermal conductivity of the upper 1.5 meters of regolith.

In situ measurements of lunar surface brightness temperatures made as a part of the Apollo Lunar Surface Experiments Package at the Apollo 15 Hadley Rille landing site are reported. Data derived from five thermocouples of the Heat Flow Experiment, which are lying on or just above the surface, are used to examine the thermal properties of the upper 15 cm of the lunar regolith using eclipse and nighttime cool-down temperatures. Application of finite-difference techniques in modeling the lunar soil shows that the thermocouple data are best fit by a model consisting of a low-density and low-thermal conductivity surface layer approximately 2 cm thick overlying a region increasing in conductivity and density with depth. Conductivities on the order of 0.00001 W per cm per deg K are postulated for the upper layer, with conductivity increasing to the order of 0.0001 W per cm per deg K at depths exceeding 20 cm. An increase in mean temperature with depth indicates that the ratio of radiative to conductive transfer at 350 K is 2.7 for at least the upper few centimeters of lunar soil; this value is nearly twice that measured for returned lunar fines.

Keihm, S. J.↗

Performance of transonic fan stage with weight flow per unit annulus area of 178 kilograms per second per square meter (6.5(lb/sec)/(sq ft))

The overall and blade-element performances are presented over the stable flow operating range from 50 to 100 percent of design speed. Stage peak efficiency of 0.834 was obtained at a weight flow of 26.4 kg/sec (58.3 lb/sec) and a pressure ratio of 1.581. The stall margin for the stage was 7.5 percent based on weight flow and pressure ratio at stall and peak efficiency conditions. The rotor minimum losses were approximately equal to design except in the blade vibration damper region. Stator minimum losses were less than design except in the tip and damper regions.

Moore, R. D.↗

Performance of transonic fan stage with weight flow per unit annulus area of 208 kilograms per second per square meter (42.6 (lb/sec)/sq ft)

Performance was obtained for a 50-cm-diameter compressor designed for a high weight flow per unit annulus area of 208 (kg/sec)/sq m. Peak efficiency values of 0.83 and 0.79 were obtained for the rotor and stage, respectively. The stall margin for the stage was 23 percent, based on equivalent weight flow and total-pressure ratio at peak efficiency and stall.

Urasek, D. C.↗

Performance of transonic fan stage with weight flow per unit annulus area of 198 kilograms per second per square meter (40.6(lb/sec)/sq ft)

The overall and blade-element performance are presented for an air compressor stage designed to study the effect of weight flow per unit annulus area on efficiency and flow range. At the design speed of 424.8 m/sec the peak efficiency of 0.81 occurred at the design weight flow and a total pressure ratio of 1.56. Design pressure ratio and weight flow were 1.57 and 29.5 kg/sec (65.0 lb/sec), respectively. Stall margin at design speed was 19 percent based on the weight flow and pressure ratio at peak efficiency and at stall.

Kovich, G.↗

Metering gun for dispensing precisely measured charges of fluid

A cyclically operable fluid dispenser for use in dispensing precisely measured charges of potable water aboard spacecraft is described. The dispenser is characterized by (1) a sealed housing adapted to be held within a crewman's palm and coupled with a pressurized source of potable water; (2) a dispensing jet projected from the housing and configured to be received within a crewman's lips; (3) an expansible measuring chamber for measuring charges of drinking water received from the source; (4) and a dispenser actuator including a lever extended from the housing to be digitated for initiating operational cycles, whereby precisely measured charges of potable water selectively are delivered for drinking purposes in a weightless environment.

Cook, T. A.↗

The feasibility of a fluidic respiratory flow meter

A study was undertaken to determine the feasibility of adapting a fluidic airspeed sensor for use as a respiratory flowmeter. A Pulmonary Function Testing Flowmeter was developed which should prove useful for mass screening applications. The fluidic sensor threshold level was not reduced sufficiently to permit its adaptation to measuring the low respiratory flow rates encountered in many respiratory disorders.

Neradka, V. F.↗

A feasibility study for a remote laser water turbidity meter

A technique to remotely determine the attenuation coefficient (alpha) of the water was investigated. The backscatter energy (theta = 180 deg) of a pulse laser (lambda = 440 - 660 nm) was found directly related to the water turbidity. The greatest sensitivity was found to exist at 440 nm. For waters whose turbidity was adjusted using Chesapeake Bay sediment, the sensitivity in determining alpha at 440 nm was found to be approximately 5 - 10%. A correlation was also found to exist between the water depth (time) at which the peak backscatter occurs and alpha.

Hickman, G. D.↗

Electromagnetic flow rate meter

A liquid metal, whose flow rate is to be determined, is directed through a chamber made of electrically-insulating material on which there is impressed a magnetic field perpendicular to the direction of flow of the liquid metal. The magnetic field is made to increase in strength in a downstream direction of the flow of liquid metal. At least a pair of electrodes are disposed in the chamber traversely and perpendicular to the direction of flow and an ammeter is connected between the electrodes. Electrodes may be disposed in the top or the bottom of the chamber and each may be segmented. Oppositely disposed electrodes may be used with at least one dividing wall extending from each electrode to cause reversal of the direction of flow of the liquid metal. The magnetic field may be provided by electromagnets or permanent magnets such as shaded pole permanent magnets.

Banks, B. A.↗

High resolution observations of Cassiopeia A at meter wavelengths

Very long baseline interferometric (VLBI) observations of the supernova remnant Cassiopeia A, at 74 MHz with a 12,000-wavelength baseline and at 111 MHz with a 18,500-wavelength baseline, are reported. The fringe amplitudes are strongly varying on a time scale of about 15 to 30 minutes. The location of the extra source must lie outside the supernova remnant shell possibly associated with a concentration of emission north of the shell, or lying outside the gap in the northeastern side of the shell. The flux and spectral index deduced for the compact source depend on the assumed size, with a range of 100 Jy to 500 Jy at 74 MHz. If the source is associated with the supernova explosion, it must have been traveling at least 5000 km s/2.

Hutton, L. K.↗

A new high-speed solar radio spectrograph for meter and decameter wavelengths

The design and characteristics of a high resolution, digital solar spectrograph are discussed. The spectrometer operates in the 10 to 80 MHz range. The primary considerations in the design of the spectrograph were: (1) optimun sensitivity, (2) wide dynamic range, (3) flexibility in time and frequency resolution, and (4) modern data handling techniques with a simple computer interface.

Mosier, S. R.↗

Deployment and performance characteristics of 1.5-meter supersonic attached inflatable decelerators

Attached-inflatable-decelerator (AID) canopies fabricated from lightweight Nomex cloth and tapes were deployed in a supersonic stream from the base of a 140 deg conical aeroshell. Characteristics of the deceleration system were obtained over a wide range of Mach number, dynamic pressure, and pitch angle. All models deployed rapidly by ram air and experienced only mild deployment shock loads. Steady-state drag coefficients as high as 1.3 were obtained in the supersonic stream and were relatively insensitive to Mach number, dynamic pressure, and pitch angle. All models were free of fluttering motion. Results also showed that the AID is aerodynamically more efficient without a burble fence in a supersonic stream. Though measured meridian-tape loads were higher than those predicted by theory, the ram-air deployment rates and steady-state drag coefficients were in good agreement with theory. These results indicate that the AID is a stable, efficient decelerator in a supersonic stream and its performance is readily predictable.

Bohon, H. L.↗

Lightweight 3.66-meter-diameter conical mesh antenna reflector

A description is given of a 3.66 m diameter nonfurlable conical mesh antenna incorporating the line source feed principle recently developed. The weight of the mesh reflector and its support structure is 162 N. An area weighted RMS surface deviation of 0.28 mm was obtained. The RF performance measurements show a gain of 48.3 db at 8.448 GHz corresponding to an efficiency of 66%. During the design and development of this antenna, the technology for fabricating the large conical membranes of knitted mesh was developed. As part of this technology a FORTRAN computer program, COMESH, was developed which permits the user to predict the surface accuracy of a stretched conical membrane.

Moore, D. M.↗

Pressure-viscosity measurements for several lubricants to 5.5 x 10 to the 8th power Newtons per square meter (8 x 10 to the 4th psi) and 149 C (300 F)

A capillary viscometer was used to measure viscosity as a function of pressure, temperature, and shear stress for a number of lubricants. The conditions under which the measurements were made are specified. The results obtained for each material are analyzed. It was determined that all pressure-viscosity coefficients decreased with increasing temperature. Data from other techniques such as optical elastohydrodynamics, oscillating crystal, and low shear capillary viscometry were compared with the results obtained.

Jones, W. R.↗