Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Measurement Science Laboratory”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,153 records · Page 64

Low energy inelastic neutron scattering (INS) data of SrCoGe2O6 taken at CNCS chopper spectrometer.

INS measurements were performed using the Cold Neutron Chopper Spectrometer CNCS at the Spallation Neutron Source (SNS) at Oak Ridge National Laboratory. A powder sample of SrCoGe2O6 was loaded in an aluminum can for the measurements and a standard orange cryostat was used to cover the temperature region from 1.7 K to 100 K. Data were collected using fixed incident neutron energy of 5.0 meV.

MATERIALS SCIENCE↗

Catalytic Pulping of Wood

The pulp and paper industry is an essential segment of the U.S. economy, making products necessary for everyday life from renewable resources. Lignin is a naturally occurring polymer in wood that must be removed to expose the polysaccharides used in the pulping industry to produce paper products. Kraft pulping, the predominant technology, is capital- and energy-intensive, and it provides a less efficient use of wood resources than desired. Catalytic methods offer a viable alternative to increase cellulose fiber yield by improving selectivity, reducing energy use and eliminating the formation of odor-causing mercaptans associated with kraft pulping. If successful, catalytic methods will improve yield, reduce fiber waste, reduce energy use, lower the cost of bleaching and decrease the cost of air emission controls. The purpose of this CRADA was to combine industrial expertise in wood pulping with national laboratory expertise in high-performance computing eventually leading to the design of new catalysts that can remove lignin from wood pulp efficiently and cost-effectively. A combined computational and experimental approach was used to investigate the detailed chemical mechanism of oxidation of ligninlike small molecules by a cobalt-based catalyst. These reactions were also investigated in the laboratory by synthesizing the catalyst and lignin-like phenols and measuring reaction yields for the formation of benzoquinones and benzaldehydes. In this report we summarize the accomplishments of the project.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Capillary Isotachophoresis-Nanoelectrospray Ionization-Selected Reaction Monitoring MS via a Novel Sheathless Interface for High Sensitivity Sample Quantification

A novel sheathless CITP/CZE-MS interface featuring a large i.d. separation capillary and a detachable small i.d. ESI emitter was developed in this study to simultaneously achieve large sample loading capacity and stable nanoESI operation. Crucial operating parameters, including sample loading volume, flow rate, and separation window, were systematically investigated to attain optimum CITP/CZE separation efficiency and MS detection sensitivity. The performance of CITP/CZE-nanoESI-MS using the new sheathless interface was evaluated for its achievable low limit of quantitation (LOQ) by analyzing targeted peptides, leu-enkephalin and angiotensin II, spiked in a BSA tryptic digest matrix at different concentrations. A linear dynamic range spanning 4.5 orders of magnitude and a 10 pM LOQ with excellent measurement reproducibility were obtained experimentally for both targeted peptides, representing a 5-fold sensitivity improvement as compared to using the sheath liquid interface developed previously.

Environmental Molecular Sciences Laboratory↗

Study of sorption-retarded U(VI) diffusion in Hanford silt/clay material

A diffusion cell method was developed to measure the effective aqueous diffusion coefficient for U(VI) under strictly controlled chemical conditions within the inter-particle pores of silt/clay sediment from the DOE Hanford site, WA. "Inward-flux” diffusion studies were conducted in which U(VI) concentrations in both aqueous and solid phases were measured as a function of distance into the cell under conditions of constant concentration at the cell boundaries. A sequential extraction method was developed to measure sorbed U(VI) content in the solid phase, while accounting for the non-negligible extractable background U(VI). U(VI) diffusion data were found to be consistent with a model that assumed that: 1) a single effective aqueous diffusion coefficient could be used to simulate the coupled diffusion of various aqueous U(VI) species, and 2) the local equilibrium assumption (LEA) is appropriate for modeling the effects of sorption under the given experimental conditions. An effective aqueous diffusion coefficient (De) of 1.6x10^-6 cm2/s was obtained under conditions of pH 8.0 and calcite saturation that are relevant to the subsurface conditions at some regions of the Hanford site. The developed experimental techniques provide a practical approach for measuring effective aqueous U(VI) diffusivity in sorptive porous media.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

A Preorganized Hydrogen Bond Network and Its Effect on Anion Stability

Rigid tricyclic locked in all axial 1,3,5-cyclohexanetriol derivatives with 0–3 trifluoromethyl groups were synthesized and photoelectron spectra of their conjugate bases and chloride anion clusters are reported along with density functional computations. The resulting vertical and adiabatic detachment energies provide measures of the anion stabilization due to the hydrogen bond network and inductive effects. The latter mechanism is found to be transmitted through space via hydrogen bonds

Environmental Molecular Sciences Laboratory↗

Structural Insights into the Interaction Between a Potent Anti-Inflammatory Protein, Viral CC Chemokine Inhibitor (vCCI), and the Human CC Chemokine, Eotaxin-1

Chemokines play important roles in the immune system, not only recruiting leukocytes to the site of infection and inflammation but also guiding cell homing and cell development. The soluble poxvirusencoded protein vCCI, a CC chemokine inhibitor, can bind to human CC chemokines tightly to impair the host immune defense. This protein has no known homologs in eukaryotes, and may represent a potent method to stop inflammation. Previously, our structure of the vCCI:MIP-1β complex indicated that vCCI uses negatively charged residues in β-sheet II to interact with positively charged residues in the MIP-1βN-terminus, 20’s region and 40’s loop. However, the interactions between vCCI and other CC chemokines have not yet been fully explored. Here, we used NMR and fluorescence anisotropy to study the interaction between vCCI and eotaxin-1 (CCL11), another CC chemokine that is an important factor in the asthma response. NMR results reveal that the binding pattern is very similar to the vCCI:MIP-1βcomplex, and suggest that electrostatic interactions provide a major contribution to binding. Fluorescence anisotropy results on variants of eotaxin-1 further confirm the critical roles of the charged residues in eotaxin. Compared to wild-type eotaxin, single, double, or triple mutations at these critical charged residues weaken the binding. One exception is the K47A mutation that exhibits increased affinity for vCCI, which can be explained structurally. In addition, the binding affinity between vCCI and other wild type CC chemokines, MCP-1, MIP-1β and RANTES, were determined as 1.09 nM, 1.16 nM, and 0.22 nM, respectively. To our knowledge, this is the first work quantitatively measuring the binding affinity between vCCI and different CC chemokines.

anti-inflammatory protein↗

Extending the Capabilities of Single Particle Mass Spectrometry: I. Measurements of Aerosol Number Concentration, Size Distribution, and Asphericity

Single particle mass spectrometers have traditionally been deployed to measure the size and composition of individual particles at relatively slow sampling rates that are determined by the rate at which the ionization lasers can fire and/or mass spectra can be recorded. To take advantage of the fact that under most conditions SPLAT can detect and size particles at much higher rates we developed a dual data acquisition mode, in which particle number concentrations, size distributions, and asphericity parameters are measured at a particle concentration determined rate, all the while the instrument generates and records mass-spectra at an operator set rate. We show that with this approach particle number concentration and asphericity parameters are measured with 1 sec resolution and particle vacuum aerodynamic size distributions are measured with 10 sec to 60 sec resolution. SPLAT measured particle number concentrations are in perfect agreement with the PCASP. Particle asphericity parameters are based on measured particle beam divergence. We illustrate the effect that high particle concentrations can have on the measured size distributions and develop a method to remove these effects and correct the size distributions.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

The development and evolution of biological AMS at Livermore: a perspective

Biological accelerator mass spectrometry (AMS) provides ultrasensitive carbon-14 isotopic analysis enabling a deeper understanding of human health concerns by enabling quantification of pharmacokinetics and other molecular endpoints directly in humans. It enables environmentally and human relevant studies of metabolic pathways through the use of very low concentrations of labeled metabolic substrates in cells and organisms. Here, we discuss why AMS is an important tool for the biosciences, the development and evolution of biological AMS at Livermore and discuss technical refinements that will improve the efficiency of operation for the measurement of ultra-trace levels of 14 C, which, long term, will enable greater ease of use and sample throughput.

47 OTHER INSTRUMENTATION↗

Soil Organic Matter (SOM): Mass Spectrometry Data Analysis

Considered a general purpose tool for characterization of samples at the molecular level in environmental and life sciences, mass spectrometry (MS) is commonly used for measuring organic matter in air, water and soil. Broad base of commercially available instrumentation and data analysis tools provide functional analytical platforms for molecular characterization for a variety of applications and samples. MS instrumentation with ultrahigh resolving power (m/ΔmFWHM > 200 000) is necessary for broad identification of thousands of molecular components present in organic matter samples. This article discusses basic principles of data analysis for ultrahigh resolution MS measurements of small molecules of organic matter.

Environmental Molecular Sciences Laboratory↗

Real-time neutron multiplicity and source localization for criticality safety during fuel debris removal

Advancing neutron detection and analysis techniques for complex radiation environments is an ongoing focus in nuclear instrumentation and monitoring. This proposal presents research and development of a generalized real-time neutron monitoring and analysis system, applicable to any detector capable of producing time-tagged neutron count data. While the work is demonstrated using the Neutron Multiplication Analysis Detector (NoMAD), a modular 15-tube helium-3 (He-3) array, due to its availability, spatial resolution, and flexible deployment, the methods developed are extensible to other systems, including organic scintillators and fast digital detectors. This research investigates two complementary analytical techniques for real-time characterization of neutron emitting sources: neutron multiplicity estimation based on the Hage-Cifarelli formalism and spatial localization using supervised machine learning applied to spatial count rate patterns. These methods are designed to operate under dynamic, evolving conditions such as fuel debris retrieval or reactor startup, where neutron-emitting material geometries may be partially unknown or changing over time. By integrating statistical neutron emission data with spatial localization, this research aims to develop and evaluate methods for real time neutron monitoring, source characterization, and material verification. Key contributions include implementation of a low-latency data pipeline for continuous neutron multiplicity analysis, development and validation of machine learning models for spatial inference, and experimental evaluation of system performance under variable measurement conditions. The outcomes are intended to support applications in nuclear safeguards, verification, emergency response, and reactor startup.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

SU-F-19A-02: Comparison of Absorbed Dose to Water Standards for HDR Ir-192 Brachytherapy Between the LCR, Brazil and NRC, Canada

Purpose: To compare absorbed dose to water standards for HDR brachytherapy dosimetry developed by the Radiological Science Laboratory of Rio de Janeiro State University (LCR) and the National Research Council, Canada (NRC). Methods: The two institutions have separately developed absorbed dose standards based on the Fricke dosimetry system. There are important differences between the two standards, including: preparation and read-out of the Fricke solution, irradiation geometry of the Fricke holder in relation to the Ir-192 source, and determination of the G-value to be used at Ir-192 energies. All measurements for both standards were made directly at the NRC laboratory (i.e., no transfer instrument was used) using a single Ir-192 source (microSelectron v2). In addition, the NRC group has established a self-consistent method to determine the G-value for Ir-192, based on an interpolation between G-values obtained at Co-60 and 250kVp X-rays, and this measurement was repeated using the LCR Fricke solution to investigate possible systematic uncertainties. Results: G-values for Co-60 and 250 kVp x-rays, obtained using the LCR Fricke system, agreed with the NRC values within 0.5 % and 1 % respectively, indicating that the general assumption of universal G-values is appropriate in this case. The standard uncertainty in the determination of G for Ir-192 is estimated to be 0.6 %. For the comparison of absorbed dose measurements at the reference point for Ir-192 (1 cm depth in water, perpendicular to the seed long-axis), the ratio Dw(NRC)/Dw(LCR) was found to be 1.011 with a combined standard uncertainty of 1.7 %, k=1. Conclusion: The agreement in the absorbed dose to water values for the LCR and NRC systems is very encouraging. Combined with the lower uncertainty in this approach compared to the present air-kerma approach, these results reaffirm the use of Fricke solution as a potential primary standard for HDR Ir-192 brachytherapy.

07 ISOTOPE AND RADIATION SOURCES↗

UAS remote sensing (Osprey platform): Red-green-blue (RGB) imagery, thermal infrared (TIR) imagery, and canopy reflectance, Seward Peninsula, Alaska, 2019

Airborne remote sensing data collected using the Brookhaven National Laboratory's (BNL) heavy-lift unoccupied aerial system (UAS) octocopter platform - the Osprey - operated by the Terrestrial Ecosystem Science and Technology (TEST) group (https://www.bnl.gov/testgroup). This package includes data from 17 flights flown over the NGEE-Arctic Council Mile Maker 64 (MM64) and Teller MM27 sites in July, 2019. The Osprey is a multi-sensor UAS platform that simultaneously measures very high spatial resolution optical red/green/blue (RGB) and thermal infrared (TIR) surface "skin" temperature imagery, as well as surface reflectance at 1 nm intervals in the visible to near-infrared spectral range from ~350-1000 nm measured at regular intervals along each flight path. This package provide the Level 0 (raw, unprocessed) data collected by the Osprey platform. Ancillary aircraft data, flight mission parameters, and general flight conditions provided by the onboard flight and data collection computers are also included. Data and metadata are provided as text (*.txt, *.json), tabular (*.dat, *.csv, *.waypoint), and image (*.jpg) formats. This metadata document contains flight campaign, instrument and file metadata, along with a description of the L0 data, and file naming scheme. The Next-Generation Ecosystem Experiments: Arctic (NGEE Arctic), was a research effort to reduce uncertainty in Earth System Models by developing a predictive understanding of carbon-rich Arctic ecosystems and feedbacks to climate. NGEE Arctic was supported by the Department of Energy's Office of Biological and Environmental Research. The NGEE Arctic project had two field research sites: 1) located within the Arctic polygonal tundra coastal region on the Barrow Environmental Observatory (BEO) and the North Slope near Utqiagvik (Barrow), Alaska and 2) multiple areas on the discontinuous permafrost region of the Seward Peninsula north of Nome, Alaska. Through observations, experiments, and synthesis with existing datasets, NGEE Arctic provided an enhanced knowledge base for multi-scale modeling and contributed to improved process representation at global pan-Arctic scales within the Department of Energy's Earth system Model (the Energy Exascale Earth System Model, or E3SM), and specifically within the E3SM Land Model component (ELM).

54 ENVIRONMENTAL SCIENCES↗

Proceedings of the Twelfth International Symposium on Space Terahertz Technology

The Twelfth International Symposium on Space Terahertz Technology was held February 14-16, 2001 in San Diego, California, USA. This symposium was jointly sponsored by the National Aeronautics and Space Administration (NASA) and the Jet Propulsion Laboratory, California Institute of Technology. The symposium featured sixty nine presentations covering a wide variety of technical topics relevant to Terahertz Technology. The presentations can be divided into five broad technology areas: Hot Electron Bolometers, superconductor insulator superconductor (SIS) technology, local oscillator (LO) technology, Antennas and Measurements, and Direct Detectors. The symposium provides scientists, engineers, and researchers working in the terahertz technology and science fields to engineers their work and exchange ideas with colleagues.

Mehdi, Imran↗

CIGS P1, P2, P3 Scribing Processes using a Pulse Programmable Industrial Fiber Laser: Preprint

We describe a novel set of laser processes for the CIGS P1, P2 and P3 scribing steps, the development of which has been enabled by a unique pulse-programmable fiber laser. We find that the unique pulse control properties of this 1064 nm wavelength laser have significant effects on the material removal dynamics of the various film layers in the CIGS material system. In the case of the P2 and P3processes, the shaped pulses create new laser/material interaction effects that permit the material to be cleanly and precisely removed with zero Heat Affected Zone (HAZ) at the edges of the scribe. The new P2 and P3 processes we describe demonstrate the first use of infrared nanosecond laser pulses that eliminate the HAZ and the consequent localized compositional changes in the CIGS absorbermaterial that result in poor shunt resistance. SEM micrographs and EDX compositional scans are presented. For the P1 scribe, we process the bi-layer molybdenum from the film side as well as through the glass substrate. Microscopic inspection and compositional analysis of the scribe lines are not sufficient to determine electrical and optical performance in working PV modules. Therefore, todemonstrate the applicability of the infrared pulse-programmable laser to all three scribing processes for thin-film CIGS, we fabricate small-size multiple-cell monolithically interconnected mini-modules in partnership with the National Renewable Energy Laboratory (Golden, Colorado). A total of four mini-modules are produced, two utilizing all laser scribing, and two with the P2 and P3 stepsmechanically scribed (by a third party) for reference. Mini-module performance data measured at NREL is presented, and we also discuss the commercialization potential of the new single-laser CIGS scribing process. Finally we present a phenomenological model to describe this physics underlying this novel ablation process.

14 SOLAR ENERGY↗

Fast-Neutron Activation of Long-Lived Isotopes in Enriched Ge

We measured the production of 57Co, 54Mn, 68Ge, 65Zn, and 60Co in an sample of Ge enriched in isotope 76 due to high-energy neutron interactions. These isotopes are critical in understanding background in Ge detectors used for double-beta decay experiments. These isotopes are produced by cosmogenic-neutron interactions in the detectors while they reside on the Earth's surface. We compared the measured production to that predicted by cross-section calculations based on CEM03.02. The cross section calculations over-predict our measurements by approximately a factor of 2-3 depending on isotope. We then use the measured cosmic-ray neutron ux and our results to predict the cosmogenic production rate with an accuracy near 15%.

Environmental Molecular Sciences Laboratory↗

Opinion: Lighting Research During and After the Pandemic

For many lighting researchers, the recent restrictions related to COVID-19 have paused most in-person laboratory or field experiments. In certain countries, regulatory institutions have allowed such experiments to resume but issued safety recommendations like pre-checking participants for disease symptoms and excluding those that are especially vulnerable. To avoid potential complications and delays, researchers are likely to resort to other research designs that enable remote research — eliminating the need for the experimenter and subjects to be in the same room. While unanticipated, this shift to remote research methods is an opportunity to revisit and further develop remote experimental techniques, which can have beneficial long-lasting implications on lighting research during and after the pandemic. Perhaps the most common type of remote research is online experiments; which can greatly benefit from improved techniques to allow for greater control or characterization of experimental conditions, like those proposed by Villa and Labayrade . These techniques require validation specific to the type of response collected and context, e.g. space type and attributes. New research techniques continue to emerge and will enable remote collection of objective measures such as gaze direction and high dynamic range images (HDRIs) without specialized equipment. In fact, many of these methods and techniques are commonly used in other disciplines, like vision science and psychology, and can be adapted for lighting research. Not all lighting studies can be conducted online, but in the age of ubiquitous and connected technologies, there is a largely missed opportunity to utilize crowdsourced responses to lighting conditions in real environments where people live and go about their daily lives without the research being limited to a certain time and laboratory locations. For instance, outdoor street luminaires can be rated by passersby using ecological momentary assessments on mobile phones. While this approach does not provide laboratory-level control over experimental conditions, it can provide more contextual responses resulting from ‘normal’ dynamic gaze, behavior, and interactions. Further, it can also reduce bias related to the experimental setting. Further development of remote research methods and their use in lighting research can improve the quality of lighting research. Given that sample sizes in most lighting research are relatively small, remote research can substantially increase sample sizes, reduce research costs, and shorten study duration, all while reducing interaction between experimenter and subjects. Another benefit is reaching a wider audience and including under-represented individuals who typically are not reachable using common recruitment methods. The pandemic has set back our plans for in-lab experiments, but can it inspire us to think of new and creative ways to expand lighting research?

Abboushi, Belal K.↗

Viscosity Measurements in Extreme Conditions

Radiation-hydrodynamics simulations are critical to the NNSA complex for understanding high energy density physics and for addressing problems in national security science. However, current rad-hydro codes typically do not account for viscosity, which generally leads to large uncertainties in problems involving mixing of materials under shock loading. This report details progress made towards experimental measurements of fluid viscosity at high pressures and temperatures achieved by shock wave compression techniques, as well as complementary material model development and hydrodynamic simulations.

36 MATERIALS SCIENCE↗