Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “MULTIPLE SCATTERING”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,153 records · Page 64

A generalized muon trajectory estimation algorithm with energy loss for application to muon tomography

Here, this work presents a generalized muon trajectory estimation (GMTE) algorithm to estimate the path of a muon in either uniform or nonuniform media. The use of cosmic ray muons in nuclear nonproliferation and safeguards verification applications has recently gained attention due to the non-intrusive and passive nature of the inspection, penetrating capabilities, as well as recent advances in detectors that measure position and direction of the individual muons before and after traversing the imaged object. However, muon image reconstruction techniques are limited in resolution due to low muon flux and the effects of multiple Coulomb scattering (MCS). Current reconstruction algorithms, e.g., point of closest approach (PoCA) or straight-line path (SLP), rely on overly simple assumptions for muon path estimation through the imaged object. For robust muon tomography, efficient and flexible physics-based algorithms are needed to model the MCS process and accurately estimate the most probable trajectory of a muon as it traverses an object. In the present work, the use of a Bayesian framework and a Gaussian approximation of MCS are explored for estimation of the most likely path of a cosmic ray muon traversing uniform or nonuniform media and undergoing MCS. The algorithm’s precision is compared to Monte Carlo simulated muon trajectories. It was found that the algorithm is expected to be able to predict muon tracks to less than 1.5 mm RMS for 0.5 GeV muons and 0.25 mm RMS for 3 GeV muons, a 50% improvement compared to SLP and 15% improvement when compared to PoCA. Further, a 30% increase in useful muon flux was observed relative to PoCA. Muon track prediction improved for higher muon energies or smaller penetration depth where energy loss is not significant. Finally, the effect of energy loss due to ionization is investigated, and a linear energy loss relation that is easy to use is proposed.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Performance evaluation of cosmic ray muon trajectory estimation algorithms

Muons, being elementary particles with minimal interaction with nuclear materials and abundant at sea level, have sparked interest in utilizing them for imaging various applications, such as mining [Borselli et al., Sci. Rep. 12, 22329 (2022)], volcano imaging [Nagamine et al., Nucl. Instrum. Meth. A, 356, 585(1995)], and underground tunnel detection [Guardincerri et al., Pure Appl. Geophys. 174, 2133 (2017)]. Recently, their use in nuclear nonproliferation and safeguard verification has gained attention, particularly in cargo screening for nuclear waste smuggling [Baesso et al., J. Instrum. 9, C10041 (2014)], source localization [L. J. Schultz et al., Nucl. Instrum. Meth. A 519, 687 (2004)], and locating nuclear fuel debris in reactors [Borozdin et al., Phys. Rev. Let. 109, 152501 (2012)]. However, the resolution of muon image reconstruction techniques is limited due to multiple Coulomb scattering (MCS) within the target object. To achieve robust muon tomography, it is crucial to develop efficient and flexible physics-based algorithms that can model the MCS process accurately and estimate the most probable trajectory of muons as they pass through the target object. To address this limitation, in this study, a novel algorithmic approach utilizing the Bayesian probability theory and Gaussian approximation of MCS is chosen. Different energy levels, materials, and target sizes were considered in the evaluations. The results demonstrate that the Generalized Muon Trajectory Estimation (GMTE) algorithm offers significant improvements over currently used algorithms. Across all test scenarios, the GMTE algorithm demonstrated ~50% and 38% increase in precision compared to Straight Line Path (SLP) and Point of Closest Approach (PoCA) algorithms, respectively. Furthermore, it exhibited 10%–35% and 10%–15% increases in muon flux utilization for high and medium Z materials, respectively, compared to the PoCA algorithm. In conclusion, the extensive simulations confirm the enhanced performance and efficiency of the GMTE algorithm, offering improved resolution and reduced measurement time for cosmic ray muon imaging compared to the current SLP and PoCA algorithms.

79 ASTRONOMY AND ASTROPHYSICS↗

Simulations of muon imaging with the LANL GMT detector for spent nuclear fuel cask content verification

Atmospheric muons are typically high energy, highly penetrating charged particles. They interact with matter primarily through multiple Coulomb scatterings. Muon scattering intensities can be used to characterize the density and atomic number of the matter that they pass through. Previously, the Los Alamos National Laboratory (LANL) muon tomography team performed muon imaging of the partially filled MC-10 spent nuclear fuel (SNF) cask at Idaho National Laboratory (INL). This experiment demonstrated the feasibility of muon imaging for the verification of spent fuel container contents. That original effort used the mini muon tracker array, consisting of two arrays of drift tubes on either side of the SNF cask. The reconstructed image quality was limited by statistics, largely due to low muon flux at high zenith angles. A LANL led team will perform new measurements with a larger array, the Giant Muon Tracker (GMT), to improve data collection rates and statistics. In this work, simulations were performed with the GMT near the partially filled INL MC-10 cask. For more general fuel diversion detection, a full MC-10 cask and casks with a singular missing fuel bundle were also simulated. To understand minimum measurement times needed for missing bundle identification, 100 000 to millions of tracked muons (corresponding to 1.4 days to several weeks measurement time) were analyzed. Simulated images were then analyzed visually and numerically to explore techniques designed to minimize the collection time needed to identify the diversion of fuel in each scenario.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Modelling of radiative transfer by the Monte Carlo method and solving the inverse problem based on a genetic algorithm according to experimental results of aerosol sensing on short paths using a femtosecond laser source

We consider the algorithms that implement a broadband ('multiwave') radiative transfer with allowance for multiple (aerosol) scattering and absorption by main atmospheric gases. In the spectral range of 0.6 – 1 μm, a closed numerical simulation of modifications of the supercontinuum component of a probing femtosecond pulse is performed. In the framework of the algorithms for solving the inverse atmospheric-optics problems with the help of a genetic algorithm, we give an interpretation of the experimental backscattered spectrum of the supercontinuum. An adequate reconstruction of the distribution mode for the particles of artificial aerosol with the narrow-modal distributions in a size range of 0.5 – 2 mm and a step of 0.5 mm is obtained. (light scattering)

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Consolidating WLCG topology and configuration in the Computing Resource Information Catalogue

Here, the Worldwide LHC Computing Grid infrastructure links about 200 participating computing centres affiliated with several partner projects. It is built by integrating heterogeneous computer and storage resources in diverse data centres all over the world and provides CPU and storage capacity to the LHC experiments to perform data processing and physics analysis. In order to be used by the experiments, these distributed resources should be well described, which implies easy service discovery and detailed description of service configuration. Currently this information is scattered over multiple generic information sources like GOCDB, OIM, BDII and experiment-specific information systems. Such a model does not allow to validate topology and configuration information easily. Moreover, information in various sources is not always consistent. Finally, the evolution of computing technologies introduces new challenges. Experiments are more and more relying on opportunistic resources, which by their nature are more dynamic and should also be well described in the WLCG information system. This contribution describes the new WLCG configuration service CRIC (Computing Resource Information Catalogue) which collects information from various information providers, performs validation and provides a consistent set of UIs and APIs to the LHC VOs for service discovery and usage configuration. The main requirements for CRIC are simplicity, agility and robustness. CRIC should be able to be quickly adapted to new types of computing resources, new information sources, and allow for new data structures to be implemented easily following the evolution of the computing models and operations of the experiments.

97 MATHEMATICS AND COMPUTING↗

Local Observation of the Site Occupancy of Mn in a MnFePSi Compound

MnFePSi compounds are promising materials for magnetic refrigeration as they exhibit a giant magnetocaloric effect. From first principles calculations and experiments on bulk materials, it has been proposed that this is due to the Mn and Fe atoms preferentially occupying two different sites within the atomic lattice. A recently developed technique was used to deconvolve the obscuring effects of both multiple elastic scattering and thermal diffuse scattering of the probe in an atomic resolution electron energy-loss spectroscopy investigation of a MnFePSi compound. This reveals, unambiguously, that the Mn atoms preferentially occupy the 3g site in a hexagonal crystal structure, confirming the theoretical predictions. After deconvolution, the data exhibit a difference in the Fe L 2,3 ratio between the 3f and 3g sites consistent with differences in magnetic moments calculated from first principles, which are also not observed in the raw data.

36 MATERIALS SCIENCE↗

Characteristics of Muon Computed Tomography of Used Fuel Casks Using Algebraic Reconstruction

Cosmic raymuons passing through matter lose energy from inelastic collisions with electrons and are deflected from nuclei due to multiple Coulomb scattering (MCS). The recent developments in position sensitive muon detectors that can measure incoming and outgoing trajectories of individual muons indicate that MCS could be an excellent candidate for spent nuclear fuel imaging. The main purpose of this paper is to evaluate tomographic scanning of spent nuclear fuel stored within vertical and horizontal dry storage casks. A quantitative analysis of the characteristics of images obtained with filtered back projection (FBP) and algebraic reconstruction techniques (ART) are presented herein, as such a comparison has not been carried out in the past. FBP is a fast tool to determine object boundaries. ART can include muon path models and prior knowledge that can improve resolution and reduce measurement time. The results demonstrate that missing fuel assemblies can be identified with more than 5 projections and that use of muon momentum significantly increases image resolution. It is expected that MCS can be used to successfully reconstruct the dry cask contents and allow identification of all described scenarios in hours. It is also expected that when total variation minimization and a non-local mean filter are applied, ART may yield much better image quality than FBP.

Liu, Zhengzhi↗

Sparse-view proton computed tomography using modulated proton beams

Purpose: Proton imaging that uses a modulated proton beam and an intensity detector allows a relatively fast image acquisition compared to the imaging approach based on a trajectory tracking detector. In addition, it requires a relatively simple implementation in a conventional proton therapy equipment. The model of geometric straight ray assumed in conventional computed tomography (CT) image reconstruction is however challenged by multiple-Coulomb scattering and energy straggling in the proton imaging. Radiation dose to the patient is another important issue that has to be taken care of for practical applications. In this work, the authors have investigated iterative image reconstructions after a deconvolution of the sparsely view-sampled data to address these issues in proton CT. Methods: Proton projection images were acquired using the modulated proton beams and the EBT2 film as an intensity detector. Four electron-density cylinders representing normal soft tissues and bone were used as imaged object and scanned at 40 views that are equally separated over 360°. Digitized film images were converted to water-equivalent thickness by use of an empirically derived conversion curve. For improving the image quality, a deconvolution-based image deblurring with an empirically acquired point spread function was employed. They have implemented iterative image reconstruction algorithms such as adaptive steepest descent-projection onto convex sets (ASD-POCS), superiorization method–projection onto convex sets (SM-POCS), superiorization method–expectation maximization (SM-EM), and expectation maximization-total variation minimization (EM-TV). Performance of the four image reconstruction algorithms was analyzed and compared quantitatively via contrast-to-noise ratio (CNR) and root-mean-square-error (RMSE). Results: Objects of higher electron density have been reconstructed more accurately than those of lower density objects. The bone, for example, has been reconstructed within 1% error. EM-based algorithms produced an increased image noise and RMSE as the iteration reaches about 20, while the POCS-based algorithms showed a monotonic convergence with iterations. The ASD-POCS algorithm outperformed the others in terms of CNR, RMSE, and the accuracy of the reconstructed relative stopping power in the region of lung and soft tissues. Conclusions: The four iterative algorithms, i.e., ASD-POCS, SM-POCS, SM-EM, and EM-TV, have been developed and applied for proton CT image reconstruction. Although it still seems that the images need to be improved for practical applications to the treatment planning, proton CT imaging by use of the modulated beams in sparse-view sampling has demonstrated its feasibility.

60 APPLIED LIFE SCIENCES↗

SU-F-BRD-09: A Random Walk Model Algorithm for Proton Dose Calculation

Purpose: To develop a random walk model algorithm for calculating proton dose with balanced computation burden and accuracy. Methods: Random walk (RW) model is sometimes referred to as a density Monte Carlo (MC) simulation. In MC proton dose calculation, the use of Gaussian angular distribution of protons due to multiple Coulomb scatter (MCS) is convenient, but in RW the use of Gaussian angular distribution requires an extremely large computation and memory. Thus, our RW model adopts spatial distribution from the angular one to accelerate the computation and to decrease the memory usage. From the physics and comparison with the MC simulations, we have determined and analytically expressed those critical variables affecting the dose accuracy in our RW model. Results: Besides those variables such as MCS, stopping power, energy spectrum after energy absorption etc., which have been extensively discussed in literature, the following variables were found to be critical in our RW model: (1) inverse squared law that can significantly reduce the computation burden and memory, (2) non-Gaussian spatial distribution after MCS, and (3) the mean direction of scatters at each voxel. In comparison to MC results, taken as reference, for a water phantom irradiated by mono-energetic proton beams from 75 MeV to 221.28 MeV, the gamma test pass rate was 100% for the 2%/2mm/10% criterion. For a highly heterogeneous phantom consisting of water embedded by a 10 cm cortical bone and a 10 cm lung in the Bragg peak region of the proton beam, the gamma test pass rate was greater than 98% for the 3%/3mm/10% criterion. Conclusion: We have determined key variables in our RW model for proton dose calculation. Compared with commercial pencil beam algorithms, our RW model much improves the dose accuracy in heterogeneous regions, and is about 10 times faster than MC simulations.

60 APPLIED LIFE SCIENCES↗

A pencil beam approach to proton computed tomography

Purpose: A new approach to proton computed tomography (pCT) is presented. In this approach, protons are not tracked one-by-one but a beam of particles is considered instead. The elements of the pCT reconstruction problem (residual energy and path) are redefined on the basis of this new approach. An analytical image reconstruction algorithm applicable to this scenario is also proposed. Methods: The pencil beam (PB) and its propagation in matter were modeled by making use of the generalization of the Fermi–Eyges theory to account for multiple Coulomb scattering (MCS). This model was integrated into the pCT reconstruction problem, allowing the definition of the mean beam path concept similar to the most likely path (MLP) used in the single-particle approach. A numerical validation of the model was performed. The algorithm of filtered backprojection along MLPs was adapted to the beam-by-beam approach. The acquisition of a perfect proton scan was simulated and the data were used to reconstruct images of the relative stopping power of the phantom with the single-proton and beam-by-beam approaches. The resulting images were compared in a qualitative way. Results: The parameters of the modeled PB (mean and spread) were compared to Monte Carlo results in order to validate the model. For a water target, good agreement was found for the mean value of the distributions. As far as the spread is concerned, depth-dependent discrepancies as large as 2%–3% were found. For a heterogeneous phantom, discrepancies in the distribution spread ranged from 6% to 8%. The image reconstructed with the beam-by-beam approach showed a high level of noise compared to the one reconstructed with the classical approach. Conclusions: The PB approach to proton imaging may allow technical challenges imposed by the current proton-by-proton method to be overcome. In this framework, an analytical algorithm is proposed. Further work will involve a detailed study of the performances and limitations of this approach in terms of image quality. The paper shows how to account for the MCS in the reconstruction step with this new approach when an analytical reconstruction algorithm is used.

60 APPLIED LIFE SCIENCES↗

SU-C-207A-01: A Novel Maximum Likelihood Method for High-Resolution Proton Radiography/proton CT

Purpose: Multiple Coulomb scattering is the largest contributor to blurring in proton imaging. Here we tested a maximum likelihood least squares estimator (MLLSE) to improve the spatial resolution of proton radiography (pRad) and proton computed tomography (pCT). Methods: The object is discretized into voxels and the average relative stopping power through voxel columns defined from the source to the detector pixels is optimized such that it maximizes the likelihood of the proton energy loss. The length spent by individual protons in each column is calculated through an optimized cubic spline estimate. pRad images were first produced using Geant4 simulations. An anthropomorphic head phantom and the Catphan line-pair module for 3-D spatial resolution were studied and resulting images were analyzed. Both parallel and conical beam have been investigated for simulated pRad acquisition. Then, experimental data of a pediatric head phantom (CIRS) were acquired using a recently completed experimental pCT scanner. Specific filters were applied on proton angle and energy loss data to remove proton histories that underwent nuclear interactions. The MTF10% (lp/mm) was used to evaluate and compare spatial resolution. Results: Numerical simulations showed improvement in the pRad spatial resolution for the parallel (2.75 to 6.71 lp/cm) and conical beam (3.08 to 5.83 lp/cm) reconstructed with the MLLSE compared to averaging detector pixel signals. For full tomographic reconstruction, the improved pRad were used as input into a simultaneous algebraic reconstruction algorithm. The Catphan pCT reconstruction based on the MLLSE-enhanced projection showed spatial resolution improvement for the parallel (2.83 to 5.86 lp/cm) and conical beam (3.03 to 5.15 lp/cm). The anthropomorphic head pCT displayed important contrast gains in high-gradient regions. Experimental results also demonstrated significant improvement in spatial resolution of the pediatric head radiography. Conclusion: The proposed MLLSE shows promising potential to increase the spatial resolution (up to 244%) in proton imaging.

60 APPLIED LIFE SCIENCES↗

SU-C-207A-03: Development of Proton CT Imaging System Using Thick Scintillator and CCD Camera

Purpose: In the treatment planning of proton therapy, Water Equivalent Length (WEL), which is the parameter for the calculation of dose and the range of proton, is derived by X-ray CT (xCT) image and xCT-WEL conversion. However, about a few percent error in the accuracy of proton range calculation through this conversion has been reported. The purpose of this study is to construct a proton CT (pCT) imaging system for an evaluation of the error. Methods: The pCT imaging system was constructed with a thick scintillator and a cooled CCD camera, which acquires the two-dimensional image of integrated value of the scintillation light toward the beam direction. The pCT image is reconstructed by FBP method using a correction between the light intensity and residual range of proton beam. An experiment for the demonstration of this system was performed with 70-MeV proton beam provided by NIRS cyclotron. The pCT image of several objects reconstructed from the experimental data was evaluated quantitatively. Results: Three-dimensional pCT images of several objects were reconstructed experimentally. A finestructure of approximately 1 mm was clearly observed. The position resolution of pCT image was almost the same as that of xCT image. And the error of proton CT pixel value was up to 4%. The deterioration of image quality was caused mainly by the effect of multiple Coulomb scattering. Conclusion: We designed and constructed the pCT imaging system using a thick scintillator and a CCD camera. And the system was evaluated with the experiment by use of 70-MeV proton beam. Three-dimensional pCT images of several objects were acquired by the system. This work was supported by JST SENTAN Grant Number 13A1101 and JSPS KAKENHI Grant Number 15H04912.

60 APPLIED LIFE SCIENCES↗

SU-F-I-54: Spatial Resolution Studies in Proton CT Using a Phase-II Prototype Head Scanner

Purpose: To characterize the modulation transfer function (MTF) of the pre-clinical (phase II) head scanner developed for proton computed tomography (pCT) by the pCT collaboration. To evaluate the spatial resolution achievable by this system. Methods: Our phase II proton CT scanner prototype consists of two silicon telescopes that track individual protons upstream and downstream from a phantom, and a 5-stage scintillation detector that measures a combination of the residual energy and range of the proton. Residual energy is converted to water equivalent path length (WEPL) of the protons in the scanned object. The set of WEPL values and associated paths of protons passing through the object over a 360° angular scan is processed by an iterative parallelizable reconstruction algorithm that runs on GP-GPU hardware. A custom edge phantom composed of water-equivalent polymer and tissue-equivalent material inserts was constructed. The phantom was first simulated in Geant4 and then built to perform experimental beam tests with 200 MeV protons at the Northwestern Medicine Chicago Proton Center. The oversampling method was used to construct radial and azimuthal edge spread functions and modulation transfer functions. The spatial resolution was defined by the 10% point of the modulation transfer function in units of lp/cm. Results: The spatial resolution of the image was found to be strongly correlated with the radial position of the insert but independent of the relative stopping power of the insert. The spatial resolution varies between roughly 4 and 6 lp/cm in both the the radial and azimuthal directions depending on the radial displacement of the edge. Conclusion: The amount of image degradation due to our detector system is small compared with the effects of multiple Coulomb scattering, pixelation of the image and the reconstruction algorithm. Improvements in reconstruction will be made in order to achieve the theoretical limits of spatial resolution.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

SU-F-T-158: Experimental Characterization of Field Size Dependence of Dose and Lateral Beam Profiles of Scanning Proton and Carbon Ion Beams for Empirical Model in Air

Purpose: The Gaussian model for the lateral profiles in air is crucial for an accurate treatment planning system. The field size dependence of dose and the lateral beam profiles of scanning proton and carbon ion beams are due mainly to particles undergoing multiple Coulomb scattering in the beam line components and secondary particles produced by nuclear interactions in the target, both of which depend upon the energy and species of the beam. In this work, lateral profile shape parameters were fitted to measurements of field size dependence dose at the center of field size in air. Methods: Previous studies have employed empirical fits to measured profile data to significantly reduce the QA time required for measurements. From this approach to derive the weight and sigma of lateral profiles in air, empirical model formulations were simulated for three selected energies for both proton and carbon beams. Results: The 20%–80% lateral penumbras predicted by the double model for proton and single model for carbon with the error functions agreed with the measurements within 1 mm. The standard deviation between measured and fitted field size dependence of dose for empirical model in air has a maximum accuracy of 0.74% for proton with double Gaussian, and of 0.57% for carbon with single Gaussian. Conclusion: We have demonstrated that the double Gaussian model of lateral beam profiles is significantly better than the single Gaussian model for proton while a single Gaussian model is sufficient for carbon. The empirical equation may be used to double check the separately obtained model that is currently used by the planning system. The empirical model in air for dose of spot scanning proton and carbon ion beams cannot be directly used for irregular shaped patient fields, but can be to provide reference values for clinical use and quality assurance.

60 APPLIED LIFE SCIENCES↗

SU-G-TeP1-04: Deriving Spot Shape Criteria for Proton Pencil Beam Scanning

Purpose: The shape of a single beam in proton PBS influences the resulting dose distribution. Spot profiles are modelled as two-dimensional Gaussian (single/ double) distributions in treatment planning systems (TPS). Impact of slight deviations from an ideal Gaussian on resulting dose distributions is typically assumed to be small due to alleviation by multiple Coulomb scattering (MCS) in tissue and superposition of many spots. Quantitative limits are however not clear per se. Methods: A set of 1250 deliberately deformed profiles with sigma=4 mm for a Gaussian fit were constructed. Profiles and fit were normalized to the same area, resembling output calibration in the TPS. Depth-dependent MCS was considered. The deviation between deformed and ideal profiles was characterized by root-mean-squared deviation (RMSD), skewness/ kurtosis (SK) and full-width at different percentage of maximum (FWxM). The profiles were convolved with different fluence patterns (regular/ random) resulting in hypothetical dose distributions. The resulting deviations were analyzed by applying a gamma-test. Results were compared to measured spot profiles. Results: A clear correlation between pass-rate and profile metrics could be determined. The largest impact occurred for a regular fluence-pattern with increasing distance between single spots, followed by a random distribution of spot weights. The results are strongly dependent on gamma-analysis dose and distance levels. Pass-rates of >95% at 2%/2 mm and 40 mm depth (=70 MeV) could only be achieved for RMSD<10%, deviation in FWxM at 20% and root of quadratic sum of SK <0.8. As expected the results improve for larger depths. The trends were well resembled for measured spot profiles. Conclusion: All measured profiles from ProBeam sites passed the criteria. Given the fact, that beam-line tuning can result shape distortions, the derived criteria represent a useful QA tool for commissioning and design of future beam-line optics.

07 ISOTOPE AND RADIATION SOURCES↗

Decay of {sup 161m1,m2}Dy isomers under conditions of a resonance environment (Moessbauer Screen)

The half-lives of the isomers {sup 161m1}Dy and {sup 161m2}Dy (E = 25.6 keV and T{sub 1/2} {approx} 30 ns for the former and E = 74.6 keV and T{sub 1/2} {approx} 3 ns for the latter) placed in a {sup 160}Gd{sub 2}O{sub 3} crystal lattice at T = 300 K and surrounded by stable {sup 161}Dy nuclei in the composition of {sup 161}Dy{sub 2}O{sub 3} were measured by the method of ({beta}-{gamma}) coincidences in the beta-decay process {sup 161}Tb {yields} {sup 161}Dy. Nuclei of {sup 161m1,m2}Dy were obtained according to the chain {sup 160}Gd(n, {gamma}){sup 161}Gd {yields} {sup 161}Tb {yields} {sup 161}Dy from {sup 160}Dy{sub 2}O{sub 3} weighted portions irradiated at the PWR-M reactor of the Petersburg Nuclear Physics Institute (PNPI, Gatchina, Russia). The T{sub 1/2} value observed for the isomer {sup 161m1}Dy was found to be correlated with the number of surrounding {sup 161}Dy nuclei. The presence of this correlation in {sup 161m1}Dy can be explained by the multiple resonance scattering of photons from isomer decay within the sample used. No such correlation was observed for {sup 161m2}Dy. The half-lives measured for the isomers {sup 161m1}Dy and {sup 161m2}Dy in the absence of the above environment are 29.2(1) and 3.50(1) ns, respectively.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Measurement of the underlying event in jet events from 7 TeV proton–proton collisions with the ATLAS detector

Distributions sensitive to the underlying event in QCD jet events have been measured with the ATLAS detector at the LHC, based on 37 pb -1 of proton–proton collision data collected at a centre-of-mass energy of 7 TeV. Charged-particle mean p T and densities of all-particle E T and charged-particle multiplicity and p T have been measured in regions azimuthally transverse to the hardest jet in each event. These are presented both as one-dimensional distributions and with their mean values as functions of the leading-jet transverse momentum from 20 to 800 GeV. The correlation of charged-particle mean p T with charged-particle multiplicity is also studied, and the E T densities include the forward rapidity region; these features provide extra data constraints for Monte Carlo modelling of colour reconnection and beam-remnant effects respectively. For the first time, underlying event observables have been computed separately for inclusive jet and exclusive dijet event selections, allowing more detailed study of the interplay of multiple partonic scattering and QCD radiation contributions to the underlying event. Comparisons to the predictions of different Monte Carlo models show a need for further model tuning, but the standard approach is found to generally reproduce the features of the underlying event in both types of event selection.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Observation and measurements of the production of prompt and non-prompt ${\text {J}\psi }$ mesons in association with a ${Z}$ boson in ${pp}$ p p collisions at ${\sqrt{s}= 8\,\text {TeV}}$ with the ATLAS detector

The production of a Z boson in association with a J/ψ meson in proton–proton collisions probes the production mechanisms of quarkonium and heavy flavour in association with vector bosons, and allows studies of multiple parton scattering. Using 20.3 fb -1 of data collected with the ATLAS experiment at the LHC in pp collisions at √s=8TeV, the first measurement of associated Z + J/ψ production is presented for both prompt and non-prompt J/ψ production, with both signatures having a significance in excess of 5σ. The inclusive production cross-sections for Z boson production (analysed in μ + μ - or e + e - decay modes) in association with prompt and non-prompt J/ψ( → μ + μ - ) are measured relative to the inclusive production rate of Z bosons in the same fiducial volume to be (36.8 ± 6.7 ± 2.5) × 10 -7 and (65.8 ± 9.2 ± 4.2) × 10 -7 respectively. Normalised differential production cross-section ratios are also determined as a function of the Jψ transverse momentum. As a result, the fraction of signal events arising from single and double parton scattering is estimated, and a lower limit of 5.3 (3.7) mb at 68 (95)% confidence level is placed on the effective cross-section regulating double parton interactions.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗