Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “MASS RESOLUTION”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,153 records · Page 64

Overview of Phobos/Deimos Regolith Ion Sample Mission (PRISM) Concept

Far more definitive information on composition is required to resolve the question of origin for the Martian moons Phobos and Deimos. Current infrared spectra of the objects are inconclusive due to the lack of strong diagnostic features. Definitive compositional measurements of Phobos could be obtained using in-situ X-ray, gamma-ray, or neutron spectroscopy or collecting and returning samples to Earth for analysis. We have proposed, in lieu of those methods, to derive Phobos and Deimos compositional data from secondary ion mass spectrometry (SIMS) measurements by calibrating the instrument to elemental abundance measurements made for known samples in the laboratory. We describe the Phobos/Deimos Regolith Ion Sample Mission (PRISM) concept here. PRISM utilizes a high-resolution TOF plasma composition analyzer to make SIMS measurements by observing the sputtered species from various locations of the moons' surfaces. In general, the SIMS technique and ion mass spectrometers complement and expand quadrupole mass spectrometer measurements by collecting ions that have been energized to higher energies, 50-100 eV, and making measurements at very low densities and pressures. Furthermore, because the TOF technique accepts all masses all the time, it obtains continuous measurements and does not require stepping through masses. The instrument would draw less than 10 W and weigh less than 5 kg. The spacecraft, nominally a radiation-hardened 12U CubeSat, would use a low-thrust Solar Electric Propulsion system to send it on a two-year journey to Mars, where it would co-orbit with Deimos and then Phobos at distances as low as 27 km.

Dibraccio, Gina↗

GHRS observations of mass-loaded flows in Abell 78

Spectroscopic observations of the central star of the planetary nebula Abell 78 were obtained with the Goddard High Resolution Spectrograph (GHRS) onboard the Hubble Space Telescope (HST) in the vicinity of the C IV lambda 1548.2, 1550.8 doublet. We find a series of narrow absorption features superposed on the broad, P Cygni stellar wind profile. These features are seen in both components of the doublet at heliocentric radial velocities of -18, -71, -131, and -192 km/s. At higher velocities, individual components are no longer distinct but, rather, merge into a continuous absorption extending to approximately -385 km/s. This is among the highest velocities ever detected for gas in a planetary nebula. The -18 km/s feature originates in an outer envelope of normal composition, while the -71 km/s feature is produced in the wind-swept shell encircling an irregular wind-blown bubble in the planetary nebula center. The hydrogen-poor ejecta of Abell 78, consisting of dense knots with wind-blown tails, are located in the bubble's interior, in the vicinity of the stellar wind termination shock. The high-velocity C IV lambda 154 absorption features can be explained as due to parcels of ejecta being accelerated to high velocities as they are swept up by the stellar wind during its interaction with dense condensations of H-poor ejecta. As the ablated material is accelerated, it will partially mix with the stellar wind, creating a mass-loaded flow. The abundance anomalies seen at the rim of the bubble attest to the transport of H-poor knot material by such a flow.

Harrington, J. Patrick↗

OGLE-2015-BLG-1649Lb: A Gas Giant Planet around a Low-mass Dwarf

We report the discovery of an exoplanet from the analysis of the gravitational microlensing event OGLE-2015-BLG-1649 that challenges the core accretion model of planet formation and appears to support the disk instability model. The planet/host-star mass ratio is q = 7.2 × 10^(−3) and the projected separation normalized to the angular Einstein radius is s = 0.9. We conducted high-resolution follow-up observations using the Infrared Camera and Spectrograph (IRCS) camera on the Subaru telescope and are able to place an upper limit on the lens flux. From these measurements we are able to exclude all host stars greater than or equal in mass to a G-type dwarf. We conducted a Bayesian analysis with these new flux constraints included as priors resulting in estimates of the masses of the host star and planet. These are ML = 0.34 ± 0.19 M⊙ and M(p)=2.5 (+1.5,-1.4) M(Jup), respectively. The distance to the system is D(L)=4.23 (+1.51, -1.64) kpc. The projected star–planet separation is a(┴)=2.07 (+0.65,-0.77) au. The estimated relative lens-source proper motion, ~7.1 mas/yr, is fairly high and thus the lens can be better constrained if additional follow-up observations are conducted several years after the event.

M. Nagakane↗

Disk mass densities in edge-on spiral galaxies

Very Large Array (VLA) observations of the neutral hydrogen (HI) gas in two nearby edge-on spirals (NGC 4565 and NGC 891) successfully resolve the thickness of the gas layers in both disks over a wide range in radii. The combination of B, C, and D array data produces a 4 arcsec (approx. 200 pc) beam and 21 km s(exp -1) velocity resolution, combined with sensitivity to structures as large as 18 arcmin (approx. 54 kpc). These observations directly constrain the mid-plane disk mass densities, under the assumption of an equilibrium between the thermal pressure of the gas and the gravitational attraction of the disk. The results of a preliminary analysis are given regarding the z-velocity dispersion of the gas, the mass-to-light ratio of the disk in NGC 4565, and the roles of atomic and molecular gases. The data also allow a detailed study of the HI in these galaxies; in general their brightness temperature distributions seem similar to that in the Milky Way. Both galaxies show asymmetric HI extensions beyond the optical disk. In NGC 4565 the extension is a surprisingly abrupt warp, which may bend back to parallel the galactic plane; the velocity structure implies the warp is continuous around the disk.

Rupen, Michael P.↗

Erosion-Corrosion Detection in Carbon Steel Pipe Loops using SRNLs Thickness and Mass Loss Measurement Coupons - 20464

Structural health of waste transfer infrastructure is of utmost importance to DOE and communities surrounding their active sites. A Fitness-for-Service (FFS) program for the Waste Transfer System has been implemented by the US Department of Energy (DOE) for the purposes of evaluating and quantifying the degradation of critical components. Currently, the method of approach is to section and evaluate pipelines that have been removed at end service. In order to augment data collection methods applied to making lifespan estimates of waste transfer system components, Florida International University (FIU) has been investigating new-technology based strategies for quantifying the rate of degradation. Present research considers the option of a coupon system installed on a section of pipe at points of interest that will provide easy access to high resolution measurements of erosion/corrosion rates during operation. Researchers at Savannah River National Laboratory (SRNL) have developed this novel solution for in situ erosion and corrosion measurements in many applicable locations such as tanks, pipes, ducts, and injection points. The coupons are approximately 12.7 mm (1/2 inch) in diameter and 25.4 mm (1 inch) in length and can be placed in the pipe sections using Swagelok compression fittings. The coupon design allows for monitoring of the total degradation resulting from corrosion and erosion. High-resolution Ultrasonic Thickness (UT) testing allows in-situ monitoring of both degradation mechanisms. When removed from the system mass loss resulting from corrosion and erosion may also be evaluated. Experimental testing at FIU implemented the SRNL coupon system in a 6.10 meter (20 foot) pipe loop system comprised of 50.8 mm (2 inch) and 76.2 mm (3 inch) pipe sections in order to replicate expected use cases at the sites. Operational conditions were emulated by pumping abrasive materials through the pipeline at full capacity and collecting measurements from the SRNL coupons. Initial testing was conducted by circulating water followed by a mixture of sand and water for uniform wear rates. Thickness changes and mass loss were measured, and the surface exposed to the process fluid was observed for visual evidence of characteristic wear patterns resulting from an erosive environment. The test matrix consisted of several hours of operation and using fine, medium and coarse grain sands. Test results were analyzed to check for all three parameters (mass loss/gain, thickness change and surface patters) which could provide estimates of the remaining useful life of the pipe sections. Thus, the research presents the findings of this evaluation of the SRNL coupons as a means for conducting high accuracy, cost effective in-situ analysis of pipeline and waste transfer systems for erosion and corrosion susceptibility. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Liquid Bismuth Propellant Flow Sensor

Quantifying the propellant mass flow rate in liquid bismuth-fed electric propulsion systems has two challenging facets. First, the flow sensors must be capable of providing a resolvable measurement at propellant mass flow rates on the order of 10 mg/see with and uncertainty of less that 5%. The second challenge has to do with the fact that the materials from which the flow sensors are fabricated must be capable of resisting any of the corrosive effects associated with the high-temperature propellant. The measurement itself is necessary in order to properly assess the performance (thrust efficiency, Isp) of thruster systems in the laboratory environment. The hotspot sensor[I] has been designed to provide the bismuth propellant mass flow rate measurement. In the hotspot sensor, a pulse of thermal energy (derived from a current pulse and associated joule heating) is applied near the inlet of the sensor. The flow is "tagged" with a thermal feature that is convected downstream by the flowing liquid metal. Downstream, a temperature measurement is performed to detect a "ripple" in the local temperature associated with the passing "hotspot" in the propellant. By measuring the time between the upstream generation and downstream detection of the thermal feature, the flow speed can be calculated using a "time of flight" analysis. In addition, the system can be calibrated by measuring the accumulated mass exiting the system as a-function of time and correlating this with the time it takes the hotspot to convect through the sensor. The primary advantage of this technique is that it doesn't depend on an absolute measurement of temperature but, instead, relies on the observation of thermal features. This makes the technique insensitive to other externally generated thermal fluctuations. In this paper, we describe experiments performed using the hotspot flow sensor aimed at quantifying the resolution of the sensor technology. Propellant is expelled onto an electronic scale to provide an independent measure of the propellant mass flow rate as a function of time. In addition, two separate detection schemes are employed. The first uses a thermocouple to directly measure temperature in the fluid. The second involves the ,use of a fiber optic coupled to a photodiode allowing for detection of an increase in light emission from the fluid as the hotspot passes. the detection location.

Polzin, Kurt A.↗

FIB-ToF-SIMS characterization of irradiated U-10Zr

Post-irradiation examination (PIE) is critical for the performance assessment and qualification of nuclear fuels. Secondary ion mass spectrometry (SIMS) is a powerful materials characterization technique that allows for elemental and isotopic mapping with a depth resolution greater than EDS and EPMA. However, it has not yet been applied to PIE of metallic nuclear fuel. Here, in this work, we characterize an fast neutron spectrum irradiated U-10Zr fuel sample using a time-of-flight SIMS (ToF-SIMS) system connected to a FIB/SEM system, which allows for flexible sample analysis compared to a dedicated ToF-SIMS instrument. Analysis of the resulting hyperspectral micrograph data was aided by the development of an unsupervised machine learning (ML) algorithm that iterates on existing methods to segment the 3D micrographic datasets based on the similarity of mass spectra. The results showed that the FIB-ToF-SIMS instrument was potentially capable of spatially resolving closed fission gas bubbles in 3D by continued ion sputtering of the analyzed volume. Additionally, the ML algorithm proved useful in revealing the chemical segregation of light fission products (those with an atomic mass between approximately 85–105 amu, such as ruthenium and rhodium) plus matrix zirconium, heavy fission products (those with an atomic mass between approximately 135–150 amu, such as the lanthanides) and uranium. Future studies are planned to conduct FIB-ToF-SIMS analysis on more irradiated U-Zr samples to study the constituent redistribution.

11 - NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Potassium Stable Isotopic Compositions Measured by High-Resolution MC-ICP-MS

Potassium isotopic (K-41/K-39) compositions are notoriously difficult to measure. TIMS measurements are hindered by variable fractionation patterns throughout individual runs and too few isotopes to apply an internal spike method for instrumental mass fractionation corrections. Internal fractionation corrections via the K-40/K-39 ratio can provide precise values but assume identical K-40/K-39 ratios (e.g. 0.05% (1sigma) in [1]); this is appropriate in some cases (e.g. identifying excess K-41) but not others (e.g., determining mass fractionation effects and metrologically traceable isotopic abundances). SIMS analyses have yielded measurements with 0.25% precisions (1sigma) [2]. ICP-MS analyses are significantly affected by interferences from molecular species such as Ar-38H(+) and Ar-40H(+) and instrument mass bias. Single collector ICP-MS instruments in "cold plasma" mode have yielded uncertainties as low as 2% (1sigma, e.g. [3]). Although these precisions may be acceptable for some concentration determinations, they do not resolve isotopic variation in terrestrial materials. Here we present data from a series of measurements made on the Thermo Scientific NEPTUNE Plus multi-collector ICP-MS that demonstrate the ability to make K-41/K-39 ratio measurements with 0.07% precisions (1sigma). These data, collected on NIST K standards, indicate the potential for MC-ICP-MS measurements to look for K isotopic variations at the sub-permil level. The NEPTUNE Plus can sufficiently resolve 39K and 41K from the interfering 38ArH+ and 40ArH+ peaks in wet cold plasma and high-resolution mode. Measurements were made on small but flat, interference-free, plateaus (ca. 50 ppm by mass width for K-41). Although ICP-MS does not yield accurate K-41/K-39 values due to significant instrumental mass fractionation (ca. 6%), this bias can be sufficiently stable over the time required for several measurements so that relative K-41/K-39 values can be precisely determined via sample-standard bracketing. As cold plasma conditions can amplify matrix effects, experiments were conducted to test the matrix tolerance of measurements; the use of clean, matrix-matched samples and standards is critical. Limitations of the cold-plasma high-resolution MC-ICP-MS methodology with respect to matrix tolerance are discussed and compared with the limitations of TIMS methodologies.

Morgan, Leah E.↗

Combining ToF‐SIMS and Multivariate Analysis to Resolve Active Sites on Ni‐Based HER Catalysts

Unambiguous identification of active sites in heterogeneous catalysis remains a major challenge, particularly for materials with ultrathin, chemically mixed surface layers. Here, we demonstrate a generalizable approach that combines time-of-flight secondary ion mass spectrometry (ToF-SIMS) with multivariate statistical analysis (principal component analysis [PCA] and multivariate curve resolution [MCR]) to resolve catalytically relevant motifs at the nanoscale. Using Ni electrodes as a model system, PCA distinguished hydroxide-enriched domains from oxide- and metal-rich regions, while MCR decomposed depth profiles and 3D images into hydroxide, oxide, and metallic layers with nanometer resolution. A unique secondary-ion fragment, NiO 3 H 3 − (m/z 108.94), emerged as a marker of hydroxide-rich environments and correlated with hydrogen evolution reaction (HER) activity across a series of Ni electrodes. Complementary density functional theory (DFT) calculations revealed that Ni(OH) 2 clusters adjacent to metallic Ni offer the most favorable water dissociation energetics, establishing the structural origin of the marker. While illustrated here for Ni-based HER, this workflow provides a broadly applicable framework to isolate and rank near-surface patterns that govern catalytic activity, thereby extending ToF-SIMS from a qualitative probe to a predictive tool for active site identification.

HER active sites↗

Experimental Validation of Calorimetric Electron Capture Spectral Theory with 193 Pt

Using microcalorimeters, a high statistics, high-resolution calorimetric spectrum of electron capture in 163 Ho can be used to determine the neutrino mass. The spectral shape can be calculated from first principles with various assumptions and approximations. To determine the validity of these choices, the theoretical calculations must be compared to data from multiple isotopes. In this work, new calorimetric data for a 193 Pt-in-Pt absorber measured with a transition edge sensor are presented and compared to theoretical calculations and values from the literature.

74 ATOMIC AND MOLECULAR PHYSICS↗

Reactor antineutrino flux and anomaly

Reactor antineutrinos have played a significant role in establishing the standard model of particle physics and the theory of neutrino oscillations. In this article, we review the reactor antineutrino flux and in particular the reactor antineutrino anomaly (RAA) coined over a decade ago. RAA refers to a deficit of the measured antineutrino inverse beta decay rates at very short-baseline reactor experiments compared to the theoretically improved predictions (i.e. the Huber–Mueller model). Since the resolution of several previous experimental anomalies have led to the discovery of non-zero neutrino mass and mixing, many efforts have been invested to study the origin of RAA both experimentally and theoretically. The progress includes the observation of discrepancies in antineutrino energy spectrum between data and the Huber–Mueller model, the re-evaluation of the Huber–Mueller model uncertainties, the potential isotope-dependent rate deficits, and the better agreement between data and new model predictions using the improved summation method. Importantly, these developments disfavor the hypothesis of a light sterile neutrino as the explanation of RAA and supports the deficiencies of Huber–Mueller model as the origin. Looking forward, more effort from both the theoretical and experimental sides is needed to fully understand the root of RAA and to make accurate predictions of reactor antineutrino flux and energy spectrum for future discoveries.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Dark matter trigger for early dark energy coincidence

Current cosmological measurements present a persistent tension in the value of the current cosmic expansion rate, the Hubble constant, as inferred from cosmic microwave background (CMB) and large-scale structure (LSS) data compared to that inferred from the classical distance ladder. Early dark energy (EDE), whose cosmological role is localized in time around the epoch of matter-radiation equality just prior to the release of the CMB photons, is designed to resolve this "Hubble tension". However, the model introduces a new coincidence problem: Why should the EDE dynamics occur near matter-radiation equality if EDE is decoupled from both matter and radiation? The resolution of this problem may lie in an early dark sector (EDS), wherein the dark matter mass is dependent on the EDE scalar field. In this work, we construct such an EDS model and show that it naturally resolves the EDE coincidence problem at the background level without any fine-tuning of the coupling to dark matter or of the initial conditions. When fitting to current cosmological data, including that from the local distance ladder, CMB, and LSS, our EDS maximum-likelihood model performs comparably to EDE for resolving the Hubble tension. However, fitting the Planck CMB data requires a specific range of initial field positions to balance the scalar field fluctuations that drive acoustic oscillations, providing testable differences with other EDE models and a platform for future model-building.

79 ASTRONOMY AND ASTROPHYSICS↗

WHONDRS Summer 2019 Sampling Campaign: Global River Corridor Surface Water FTICR-MS, NPOC, TN, Anions, Stable Isotopes, Bacterial Abundance, and Dissolved Inorganic Carbon (v8)

The WHONDRS Summer 2019 Sampling (S19S) Campaign collected samples in 97 globally distributed river corridor systems between July and September 2019. Surficial streambed sediments were collected at three locations within each site (upstream, midstream, and downstream). Surface water was collected at the downstream site. This dataset includes a portion of the data types produced from the surface water samples and does not include any results from the sediment. Sediment data can be found at https://data.ess-dive.lbl.gov/view/doi:10.15485/1729719. The S19S campaign was designed with the science community to ask questions associated with links among core/transient metabolomes, microbial metabolism, biogeochemical function, and physical properties of watershed and river corridor systems. This data package was originally published in March 2020. It was updated in October 2020 (v2, new and modified files), July 2021 (v3, new and modified files), January 2023 (v4, new and modified files), February 2023 (v5, new and modified files), August 2023 (v6, new and modified files), July 2025 (v7,new and modified files), and August 2026 (v8, new and modified files). Version 8 includes major restructuring of the files and their formats. See the change history section in readme for more details. In addition to a readme, this data package also includes a file-level metadata (FLMD) file that describes each file and a data dictionary (DD) that describes all column/row headers and variable definitions. This dataset contains (1) readme, (2) data dictionary, (3) file level metadata, (4) sampling protocol, (5) a data checks report, (6) field metadata, (7) international generic sample number (IGSN) mapping file, (8) joint genome institute (JGI) mapping file, and (9) a folder of sample data. The sample data folder contains (1) dissolved organic carbon (DOC, measured as non-purgeable organic carbon, NPOC) and FTICR methods, (2) dissolved inorganic carbon (DIC), (3) stable water isotopes (O and H), (4) specific conductivity, (5) total dissolved nitrogen (TN), (6) anions, (7) flow cytometry bacterial abundance data, (8) laboratory methods, and (9) a folder containing unaligned, peak-picked high resolution characterization of dissolved organic matter from sediment via 12 Tesla Fourier transform ion cyclotron resonance mass spectrometry (FTICR-MS) through the Environmental Molecular Sciences Laboratory (EMSL, https://www.pnnl.gov/environmental-molecular-sciences-laboratory), and (12) a folder containing processed FTICR-MS data. All files are .msa, .txt, .spx, .xml, .csv, .pdf, .txt, .html, .jpg, or .jpeg.

18-O↗

FTICR, NPOC, TN, and Moisture of Variably Inundated Sediment across 48 North American Rivers

This dataset supports a broader study examining drivers of organic matter chemistry in variably inundated hyporheic zone sediments and further linking that chemistry to biogeochemical rates. The dataset provides physical and chemical sediment data collected from 48 rivers across North America. There are related data that will be published, including surficial sediment temperature time series that can be used to infer the dynamics of inundation prior to the collection of sediments. This dataset is comprised of two folders: (1) ECA2_Sediment and (2) ECA2_SitePhotos. The ECA2_Sediment folder contains: (1) file-level metadata; (2) data dictionary; (3) field metadata; (4) non-purgeable organic carbon (NPOC), total nitrogen (TN), and sediment moisture; (5) sediment sampling protocol, (6) readme, and (7) folder of high resolution characterization of organic matter from sediment extracts via 12 Tesla Fourier transform ion cyclotron resonance mass spectrometry (FTICR-MS) through the Environmental Molecular Sciences Laboratory (EMSL; https://www.pnnl.gov/environmental-molecular-sciences-laboratory). The FTICR-MS files are .xml, and the data package includes instructions for using Formularity (https://omics.pnl.gov/software/formularity) and an R script to process the data based on the user's specific needs. All other files are .csv, .txt, or .pdf. The ECA2_SitePhotos folder contains a readme and site photographs taken in the field. All files are .txt or .jpg.

54 ENVIRONMENTAL SCIENCES↗

Accelerated Climate Model for Energy (ACME): Ocean and Sea-Ice Processes

The primary goal of this project was to understand the role of the ocean and sea-ice components in the evolution of the climate in both a high-resolution fully-coupled 1850 preindustrial control and present day transient climate simulations run using the Energy Exascale Earth System Model (E3SM), formerly known as the Accelerated Climate Model for Energy (ACME). Two distinct approaches to the initialization of the present day transients were tested: in the first, an ensemble of three transients used atmospheric reanalysis forced 0.1-degree ocean/sea-ice states, while a fourth transient was branched off the preindustrial control. Biases from the control were inherited by its successor transient, in particular, sea surface temperatures (SSTs) at high latitudes were too warm and too much northward meridional heat transport occurred in the North Atlantic Ocean. SSTs in the Northern Hemisphere and Atlantic meridional heat transport increased in the transients initialized from the ocean/sea-ice simulation over a 40-50 year period to largely resemble the transient branched off the control simulation. Excessive absorbed solar radiation (ASR) is considered to be responsible for the SST biases as well as the formation of mode waters in lighter density classes than in reality both in the Southern Ocean and the North Atlantic Ocean subtropical gyre. These mode waters ventilate the thermocline waters to the north of their formation sites explaining the excessive Atlantic meridional heat transport and some of the warming in the high-latitude North Atlantic Ocean after multiple decades.

54 ENVIRONMENTAL SCIENCES↗

Constraining the Halo Mass of Damped Lyα Absorption Systems (DLAs) at z = 2–3.5 Using the Quasar-CMB Lensing Cross-correlation

We study the cross-correlation of damped Lyα systems (DLAs) and their background quasars, using the most updated DLA catalog and the Planck 2018 CMB lensing convergence field. Our measurement suggests that the DLA bias b DLA is smaller than 3.1, corresponding to log (M/M ⊙ h -1 ) ⩽ 12.3 at a confidence of 90%. These constraints are broadly consistent with Alonso et al. and previous measurements by cross-correlation between DLAs and the Lyα forest (e.g., Font-Ribera et al.; Prez-Rfols et al.). Further, our results demonstrate the potential of obtaining a more precise measurement of the halo mass of the high-redshift sources using next generation CMB experiments with a higher angular resolution. The python-based codes and data products of our analysis are available at https://github.com/LittleLin1999/CMB-lensingxDLA.

79 ASTRONOMY AND ASTROPHYSICS↗

CaptureFOAM

CaptureFOAM provides utilities for fast and accurate direct air capture (DAC) contactor simulations, based on the OpenFOAM framework. At the core, CaptureFOAM is a suite of mass transfer and chemistry models built upon the OpenFOAM thin film model, which allows coarser mesh resolution and less constrictive time step requirements when compared to a traditional volume of fluid approach. This allows CaptureFOAM to conduct device-scale simulations for complex geometries including commercial packing materials and novel contactor shapes, matching experimental results in a wide variety of applications.

Kincaid, Kellis [Oak Ridge National Laboratory (OR↗

Fine-scale motion in the central Orion nebula

The inner region of M42 has been mapped in the O III N1 forbidden line at an unprecedented combination of velocity and spatial resolution and photometric accuracy. Three separate velocity systems along the line of sight are identified. Differential mass flow is present in two of these systems. All three systems show random fluctuations in velocity well above their measurement errors. The point-by-point velocities are used to determine the diagnostic statistical parameter, the structure function. The random motions show correlation with spatial separation, as expected for turbulence; but comparison with the predictions of classical theory for nebular turbulence shows poor agreement. If Kolmogorov (1941, 1942) theory applies, then the energy must be input at many scales.

Castaneda, Hector O.↗