Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “MALES”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,153 records · Page 64

Imaging findings of hemorrhagic hepatic cysts with enhancing mural nodules

Purpose: This study aimed to evaluate the clinical and radiological findings of hemorrhagic hepatic cysts with enhancing mural nodules. Methods: The radiology databases of five facilities were retrospectively searched for reports indicating hemorrhagic hepatic cysts or hepatic cystic tumors. Cases of hemorrhagic hepatic cysts with enhancing mural nodules based on pathological or radiological findings were identified and reviewed. Results: We included 14 cases (11 female and 3 male) with a mean patient age of 72.6 years. Up until the enhancing mural nodules were detected, the cysts had decreased in size in all ten cases for which radiological imaging was available for a period of > 3 years previous to detection. Dynamic contrast-enhanced CT or MRI showed focal enhancement in the early phase and progressive centrifugal enhancement in the delayed phase in all 16 mural nodules ≥ 10 mm in diameter. Thirteen of 14 MRI assessable enhancing mural nodules ≥ 10 mm in diameter showed a hypointense rim with central hyperintensity on T2-weighted imaging. All cases showed calcification of the cyst wall. In the three referred cases, {sup 18}F-fluorodeoxyglucose (FDG) positron emission tomography/CT demonstrated no intense FDG uptake in the enhancing mural nodules. In the four resected cases, histopathology of the enhancing mural nodules revealed neovascularization within an organized hematoma, including extensive dilated vessels and hemangioma-like lesions. Conclusions: Features including a decrease in cyst size, a progressive centrifugal enhancing pattern on dynamic contrast-enhanced CT or MRI, a hypointense rim with central hyperintensity on T2-weighted MRI, and cyst wall calcification may indicate a hemorrhagic hepatic cyst.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Transnasal stent-assisted targeting technique for percutaneous jejunostomy placement in patients with hiatal hernias

Purpose: To report the transnasal stent-assisted targeting technique for percutaneous jejunostomy placement in patients with hiatal hernias. Materials and methods: Four patients, including three (75%) females and one (25%) male, with mean age of 77.5 years (range 73–78 years), and with a hiatal hernia and intrathoracic stomach precluding gastrostomy placement and loop snare placement into the mid-jejunum underwent the transnasal stent-assisted targeting technique for percutaneous jejunostomy placement. In all patients, a duodenal stent was inserted into the jejunum in a transnasal fashion. The stent was partially unsheathed in an anterior loop of jejunum and percutaneously targeted using an 18-gauge needle through which a guidewire was advanced, trapped within the stent, and removed through the nose. The tract was serially dilated and a jejunostomy was placed. Technical success, procedure time, fluoroscopy time, radiation exposure, complications, time to enteral feeding, and follow-up were recorded. Results: Technical success was 100% (4/4) with all four patients requiring only one needle pass before successful jejunal cannulation. Mean procedure time was 108 min. Mean fluoroscopy time was 44 min. Mean dose area product was 3969.3 μGym{sup 2}. No minor or major complications occurred. All four patients received enteral feeding one day after the procedure. Mean follow-up was 366 days. Conclusion: The transnasal stent-assisted targeting technique is a novel method for primary jejunostomy placement in patients with hiatal hernias.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Quantification of fat and skeletal muscle tissue at abdominal computed tomography: associations between single-slice measurements and total compartment volumes

Purpose: Body composition is of great prognostic value in several severe diseases, including different types of cancer as well as cardiometabolic disorders. We aimed to investigate the correlations of skeletal muscle mass and abdominal adipose tissue compartments between volumetric and single-slice measurements to study the usefulness of several anatomical landmarks for estimation of total compartment volumes using abdominal CT-scans. Methods: In this retrospective study volumetric quantifications of paraspinal skeletal muscles (SM) and adipose tissue compartments (visceral adipose tissue, VAT; subcutaneous adipose tissue, SAT) were performed in 50 consecutive patients (26 male; mean age, 63 ± 15 years) who underwent abdominal multislice-CT for diagnostic purposes using an in-house software. Associations between total volumes of SM, VAT, and SAT with single-slice measurements at eight predefined anatomical landmarks (median intervertebral disk spaces T12/L1 to L5/S1; level of the umbilicus (U); level of the radix of the superior mesenteric artery (SMA)) were studied using correlation coefficients. Results: Statistical analysis revealed a strong association between single-slice measurements of adipose tissue compartments with total VAT and SAT volume (VAT: all r > 0.89, P < 0.001; SAT: all r > 0.95, P < 0.001). The strongest associations with total SM volume were found for single-slice measurements obtained at L3/4 (r = 0.94, P < 0.001) and were further improved by normalization to height (r = 0.98, P < 0.001). Conclusions: Single-slice measurements of SM, VAT, and SAT at several anatomical landmarks are strongly associated with total compartment volumes and therefore allow for easy and simultaneous assessment of skeletal muscle mass and adipose tissue compartment volumes.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

CT and MRI features of undifferentiated carcinomas with osteoclast-like giant cells of the pancreas: a case series

Purpose: The purpose of this case series was to describe computed tomography (CT) and magnetic resonance imaging (MRI) features of undifferentiated carcinoma with osteoclast-like giant cells of the pancreas. Methods: Institutional ethics review board approval was obtained, and informed consent was waived for this case series. We reviewed CT and MRI of patients with pathologically confirmed undifferentiated carcinoma with osteoclast-like giant cells of the pancreas found in the medical records of our hospital between 2006 and 2016. Results: Seven patients (3 males and 4 females; age, 59–82 years (mean, 71)) with confirmation by surgical resection (n = 3) or biopsy (n = 4) were identified. They underwent CT (n = 7) and MRI (n = 6). The tumors 26–83 mm in diameter (mean, 44 mm) were located in the head (n = 4) or body (n = 3) of the pancreas. They were demonstrated as lower attenuation areas relative to the adjacent pancreas on CT images obtained in both pancreatic and portal vein phases (n = 7) with a well-defined smooth margin (n = 5). They were demonstrated as hypointense areas relative to the pancreas on T2-weighted images (n = 4) and T2*-weighted images (n = 4) and diffusion-weighted images (n = 3). They contained hemosiderin deposits on histology (n = 7). Conclusions: Undifferentiated carcinoma with osteoclast-like giant cells of the pancreas might be present as low attenuation areas with a well-defined smooth margin on CT images obtained in pancreatic and portal vein phases, and hypointense areas on T2-, T2*-, and diffusion-weighted images caused by hemosiderin deposits.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Comparison of navigator-gated and breath-held image acquisition techniques for multi-echo quantitative dixon imaging of the liver in children and young adults

Purpose: Acquired over a breath hold, multi-echo Dixon (mDixon) magnetic resonance imaging (MRI) of the liver can be used to quantify proton density fat fraction (PDFF) and iron-related signal decay. However, young, obese, and co-morbid patients may have limited breath holding capacity and could benefit from a motion-robust mDixon acquisition. The purpose of this study was to compare hepatic PDFF and R2* values between navigator-gated and breath-held mDixon MRI acquisition techniques in children and young adults with suspected liver disease. Materials and methods: This retrospective study was institutional review board-approved with a waiver of informed consent. Patients who underwent liver MRI with breath-held and navigator-gated mDixon sequences between January 2017 and July 2018 were included. One reviewer, blinded to sequence, measured PDFF and R2* on four images from each sequence. Another blinded reviewer graded respiratory motion (5-point Likert scale). Pearson correlation (r), Lin’s concordance coefficients (r{sub c}), and Bland–Altman analyses were used to assess agreement between techniques. Frequency of clinically limiting motion (score ≥ 3) was compared with Fisher’s exact test. Results: Forty-two patients were included (15 female, 27 male; mean age: 15.7 ± 4.6 years). Mean PDFF and R2* were 16.6 ± 13.1% and 29.3 ± 4.7 s{sup −1} (breath-held) versus 17.0 ± 13.2% and 29.6 ± 5.2 s{sup −1} (navigator-gated). PDFF agreed almost perfectly between sequences (r{sub c} = 0.997, 95% CI 0.994–0.998; mean bias: 0.3%; 95% limits of agreement: − 2.4 to +1.7%), while R2* values correlated very strongly but with poor agreement (r = 0.837, r{sub c} = 0.832, 95% CI 0.716–0.910). Navigator-gated images exhibited significantly higher frequency of clinically limiting respiratory motion (88% vs. 48%, p = 0.0001). Conclusion: Despite greater respiratory motion artifact, a free-breathing navigator-gated mDixon sequence produces PDFF values with almost perfect agreement to a breath-held sequence.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Diagnostic performance of magnetic resonance cholangiopancreatography (MRCP) versus endoscopic retrograde cholangiopancreatography (ERCP) in the pediatric population: a clinical effectiveness study

Purpose: To determine the diagnostic performance of magnetic resonance cholangiopancreatography (MRCP) for detecting biliary and pancreatic abnormalities in a pediatric population, using endoscopic retrograde cholangiopancreatography (ERCP) as the reference standard. Materials and methods: Institutional review board approval with a waiver of informed consent was obtained for this retrospective investigation. Records from the Cincinnati Children’s Hospital Medical Center, Division of Gastroenterology and Department of Radiology were used to identify patients aged ≤ 18 years who had undergone both ERCP and MRCP within a 4-week interval between January 2013 and May 2017. Biliary and pancreatic duct findings were documented for each modality to determine the diagnostic performance of MRCP (with 95% confidence intervals), using ERCP as the reference standard. Results: 54 patients met inclusion criteria. Mean patient age at time of ERCP was 10.4 ± 4.9 years, and 25 (46%) were male. Mean interval between ERCP and MRCP was 11.2 ± 9.7 days. For detection of any abnormality (n = 99 ERCP findings), MRCP had a sensitivity of 76.8% (67.5–84.0%) and a positive predictive value (PPV) of 81.7% (72.7–88.3%). MRCP was 75.7% (59.9–86.6%) sensitive, with a PPV of 84.9% (69.1–93.4%) for biliary findings (n = 37) and 73.5% (59.7–83.8%) sensitive, with a PPV of 78.3% (64.4–87.7%) for pancreatic findings (n = 49). For pancreatobiliary abnormalities (n = 13), MRCP had a sensitivity of 92.3% (66.7–99.6%) and a PPV of 85.7% (60.1–97.5%). Conclusion: In clinical practice, MRCP is moderately sensitive for biliary and pancreatic abnormalities, with false-negative and false-positive examinations being relatively common.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Interobserver agreement of computed tomography reporting standards for chronic pancreatitis

Aim: To assess the interobserver agreement of computed tomography (CT) reporting standards for chronic pancreatitis (CP). Subjects and methods: Retrospective analysis of CT of 47 patients (33 males and 11 females, age range 36 to 56 years) with CP who presented with abdominal pain (n = 41), steatorrhea (n = 37), and glucose intolerance (n = 31). The patients underwent CT study using a 16-multidetector CT scanner with a pancreatic protocol including a nonenhanced scan followed by pancreatic phase at 35 s and portal venous phase at 65 s after intravenous injection of nonionic contrast medium. Image analysis was performed by two radiologists according to reporting standards for CP. Results: There was excellent interobserver agreement (84.8 %) between the two reviewers in CT reporting standards for CP (K = 0.80, 95 % CI 0.75–0.85, P = 0.001). There was good interobserver agreement for pancreatic duct (PD) caliber (K = 0.71, 95 % CI 0.56–0.87, P = 0.001), PD contour (K = 0.76, 95 % CI 0.61–0.91, P = 0.001), PD stricture (K = 0.070, 95 % CI 0.53–0.88, P = 0.001), and distribution of findings (K = 0.69, 95 % CI 0.51–0.86, P = 0.001). There was excellent interobserver agreement for intraductal calculi (K = 0.84, 95 % CI 0.68–0.98, P = 0.001), pancreatic calcifications (K = 0.86, 95 % CI 0.84–0.98, P = 0.001), and pancreatic diameter (K = 0.87, 95 % CI 0.75–0.99, P = 0.001). Conclusion: CT reporting standards for CP is a reliable method for diagnosis of patients with CP.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Diffusion-weighted imaging as a part of PET/MR for small lesion detection in patients with primary abdominal and pelvic cancer, with or without TOF reconstruction technique

Objectives: To investigate the value of diffusion-weighted imaging (DWI) in detection of small lesions (≤ 10 mm) in patients with primary abdominal and pelvic cancer in hybrid PET/MR with or without time-of-flight (TOF) technique. Materials and methods: Twenty patients (11 females and 9 males, mean age 67.23 ± 12.90 years) with histologically confirmed primary abdominal and pelvic cancer underwent hybrid PET/MR examination. A total of 64 small lesions were included in this study, which were divided into two groups (≤ 10 mm and 10–30 mm). Visual scores of small lesion detection ability were rated by five-point ordinal scale. The visual scores and detectability of small lesions on TOF PET image, noTOF PET image, and DWI sequences of hybrid PET/MR examination with or without TOF technique were analyzed. Logistic regression model was established for analysis in the value of DWI in hybrid PET/MR examination with or without TOF technique in detection of the small lesions between two groups. Results: The visual evaluation revealed the small lesion (≤ 10 mm) visual scores of DWI (mean ± SD: 4.23 ± 1.41), TOF PET image (mean ± SD: 4.14 ± 0.89), and noTOF PET image (mean ± SD: 2.68 ± 1.13);.and the visual scores of small lesions (10–30 mm) on DWI (mean ± SD: 4.98 ± 0.15), TOF PET image (mean ± SD: 4.57 ± 0.59), and noTOF PET image (mean ± SD: 3.98 ± 1.05). The visual scores of all small lesions on DWI were higher than that on TOF PET data and noTOF PET data in both two groups (**P < 0.01). The missed diagnosis rates of small FDG avid lesions (≤ 10 mm) of DWI and noTOF PET image were 9.1% and 9.1%, respectively. However, the TOF PET-based clinical diagnosis detected all small lesions (≤ 30 mm). DWI was of great importance in detection of small lesions (≤ 10 mm) in the absence of TOF technique in PET/MR examination (**P < 0.01). DWI’s effect on detection of small lesions(10-30 mm) has shown no difference between PET/MR examinations with TOF and without TOF techniques (P > 0.05). Conclusion: DWI has significant value in the detection of small lesions (≤ 10 mm) in hybrid PET/MR examination without TOF technique for patients with primary abdominal and pelvic cancer. However, it had less detection benefits in the small lesions (≤ 10 mm) in hybrid PET/MR examination with TOF PET image.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

110 Patients with adenosquamous carcinomas of the pancreas (PASC): imaging differentiation of small (≤ 3 cm) versus large (> 3 cm) tumors

Objective: This study examined radiological imaging features of small (≤ 3 cm) and large (> 3 cm) adenosquamous carcinomas of the pancreas (PASC) lesions to better understand the morphology of these lesions. Methods: Images from 110 patients with pathologically proven PASC (80 males and 30 females, mean age: 62.6 years) were retrospectively reviewed. Two radiologists analyzed images and reached a consensus regarding the following features: location, shape, margins, presence of solid and necrotic components, rim enhancement, density/intensity during the portal venous phase, invasion of surrounding organs, vascular invasion, venous tumor thrombus formation, and enlarged lymph nodes. Differences in the imaging features between the two groups were evaluated with the Chi-square test or Fisher’s exact test. Results: There were 41 small PASC lesions (mean age: 60.59 years) and 69 large PASC lesions (63.74 years). Statistical analysis demonstrated significant differences in the location, shape, adjacent organ and vessel invasion, and venous tumor thrombus formation (P < 0.05). Small PASC lesions were more frequently detected in the pancreatic head and had an ovoid shape. There was no significant difference in the presence of solid and necrotic components (P = 0.090), including approximately 3/4 of the lesions with necrosis and 1/4 purely solid lesions, enlarged lymph nodes (P = 0.068) and other features. Conclusion: Regardless of the tumor size, 75% of PASC lesions present with central necrosis while 25% are purely solid. Small PASC lesions can be associated with lymph node metastasis at a relatively early stage. Large PASC lesions are likely to invade adjacent tissues and be associated with venous tumor thrombus formation.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Transcatheter arterial infusion for pancreatic cancer: a 10-year National Cancer Center experience in 115 patients and literature review

Purpose: To evaluate the efficacy and safety of transcatheter arterial infusion (TAI) for the treatment of pancreatic cancer in patients ineligible for or refractory to systemic chemotherapy. Materials and methods: The medical records of 115 consecutive patients (mean age, 58.9 years; 71 males) with documented pancreatic cancer ineligible for or refractory to systemic chemotherapy and underwent TAI between February 2007 and January 2017 were reviewed. Results: A total of 224 TAI sessions [mean, 1.9 (range 1–8)] were performed. Technical success rate was 100%. Disease control (i.e., complete response, partial response, and stable disease) was achieved in 72 (62.6%) patients. The median progression-free survival and median overall survival were 56 days and 147 days, respectively. Subgroup analysis revealed that disease control, progression-free survival, and overall survival were significantly improved in patients with an Eastern Cooperative Oncology Group score of ≤ 1 compared with those in patients with an Eastern Cooperative Oncology Group score of 2 (all p < 0.001) and in patients who received > 1 sessions of TAI compared with that in patients who received only 1 session of TAI (p = 0.012, < 0.001, and = 0.002, respectively). A major complication in the form of cerebral infarction occurred in 1 (0.9%) patient 1 day after the procedure. This patient was treated with conservative therapy and recovered without permanent adverse sequelae. No other major complications were observed. Conclusions: TAI may be effective and safe for the treatment of pancreatic cancer.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Measurement of spleen fat on MRI-proton density fat fraction arises from reconstruction of noise

Purpose: This study compares splenic proton density fat fraction (PDFF) measured using confounder-corrected chemical shift-encoded (CSE)-MRI to magnetic resonance spectroscopy (MRS) in human patients at 3T. Methods: This was a prospectively designed ancillary study to various previously described single-center studies performed in adults and children with known or suspected nonalcoholic fatty liver disease. Patients underwent magnitude-based MRI (MRI-M), complex-based MRI (MRI-C), high signal-to-noise variants (Hi-SNR MRI-M and Hi-SNR MRI-C), and MRS at 3T for spleen PDFF estimation. PDFF from CSE-MRI methods were compared to MRS-PDFF using Wilcoxon signed-rank tests. Demographics were summarized descriptively. Spearman’s rank correlations were computed pairwise between CSE-MRI methods. Individual patient measurements were plotted for qualitative assessment. A significance level of 0.05 was used. Results: Forty-seven patients (20 female, 27 male) including 12 adults (median 55 years old) and 35 children (median 12 years old). Median PDFF estimated by MRS, MRI-M, Hi-SNR MRI-M, MRI-C, and Hi-SNR MRI-C was 1.0, 2.3, 1.9, 2.2, and 2.0%. The four CSE-MRI methods estimated statistically significant higher spleen PDFF values compared to MRS (p < 0.0001 for all). Pairwise associations in spleen PDFF values measured by different CSE-MRI methods were weak, with the highest Spearman’s rank correlations being 0.295 between MRI-M and Hi-SNR MRI-M; none were significant after correction for multiple comparisons. No qualitative relationship was observed between PDFF measurements among the various methods. Conclusion: Overestimation of PDFF by CSE-MRI compared to MRS and poor agreement between related CSE-MRI methods suggest that non-zero PDFF values in human spleen are artifactual.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Restoration of Failed Renal Graft Function After Successful Angioplasty of Pressure-Resistant Renal Artery Stenosis Using a Cutting Balloon: A Case Report

This study is the report of a 37-year-old male with a transplanted kidney from a 3.5-year-old donor: the graft had two arteries transplanted with an aortic patch to an external iliac artery. Four months after transplantation, the graft function deteriorated, together with the development of hypertension. Stenosis of both graft arteries was detected and the patient was referred for angioplasty. The angiographic result was suboptimal, nevertheless, the graft function improved and was more or less stable (serum creatinine, 160-200 {mu}mol/l) for 4 years, along with persistently difficult-to-control hypertension. Five years after transplantation, the graft function deteriorated again and severe graft artery restenosis was detected. The restenosis did not respond to dilatation, graft function failed, hypertension decompensated, and left ventricular failure developed. The patient required dialysis. A cutting balloon angioplasty opened the artery, and kidney function was restored after a few days: the serum creatinine level dropped to 140-160 {mu}mol/l, and the glomerular filtration rate (creatinine clearance) to 0.65 ml/min/1.73 m{sup 2}. The graft function has now been stable for more than 2 years, however, the hypertension is still difficult to control.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Endovascular Repair of a Right-Sided Descending Thoracic Aortic Aneurysm Associated with a Right Aortic Arch and a Left Subclavian Artery Arising from a Kommerell's Diverticulum

This case report describes the endovascular repair of a right-sided descending thoracic aortic aneurysm associated with a right aortic arch and an aberrant left subclavian artery. A 76-year-old male with multiple comorbidities was incidentally found to have a right-sided descending thoracic aortic aneurysm with a maximum diameter of 6.2 cm. Additionally, there was a right aortic arch with a retroesophageal segment and separate arch branches arising in the following order: left common carotid artery, right common carotid artery, right subclavian artery, and left subclavian artery that was aberrant, arising from a Kommerrell's diverticulum. The aneurysm was successfully excluded by deployment of a Zenith TX1 36 x 32 x 20-mm stent-graft using wire traction technique via the left femoral and right brachial arteries in order to deal with two severe aortic angulations. At 18-month follow-up the patient was doing well, with aneurysm sac shrinkage to 5.9 cm and no signs of endoleak or migration. Endovascular repair of right-sided descending thoracic aortic aneurysms with a right arch and aberrant left subclavian artery is feasible, safe, and effective. In such rare configurations, which demand considerably increased technical dexterity and center experience, endovascular repair emerges as an attractive therapeutic option.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Portal Vein Embolization Using a Nitinol Plug (Amplatzer Vascular Plug) in Combination with Histoacryl Glue and Iodinized Oil: Adequate Hypertrophy with a Reduced Risk of Nontarget Embolization

The purpose of this study was to assess whether portal vein embolization (PVE) using a nitinol vascular plug in combination with histoacryl glue and iodinized oil minimizes the risk of nontarget embolization while obtaining good levels of future liver remnant (FLR) hypertrophy. Between November 2005 and August 2008, 16 patients (8 females, 8 males; mean age, 63 {+-} 3.6 years), each with a small FLR, underwent right ipsilateral transhepatic PVE prior to major hepatectomy. Proximal PVE was initially performed by placement of a nitinol vascular plug, followed by distal embolization using a mixture of histoacryl glue and iodinized oil. Pre- and 6 weeks postprocedural FLR volumes were calculated using computed tomographic imaging. Selection for surgery required an FLR of 0.5% of the patient's body mass. Clinical course and outcome of surgical resection for all patients were recorded. At surgery, the ease of hepatectomy was subjectively assessed in comparison to previous experience following PVE with alternative embolic agents. PVE was successful in all patients. Mean procedure time was 30.4 {+-} 2.5 min. Mean absolute increase in FLR volume was 68.9% {+-} 12.0% (p = 0.00005). There was no evidence of nontarget embolization during the procedure or on subsequent imaging. Nine patients proceeded to extended hepatectomy. Six patients demonstrated disease progression. One patient did not achieve sufficient hypertrophy in relation to body mass to undergo hepatic resection. At surgery, the hepatobiliary surgeons observed less periportal inflammation compared to previous experience with alternative embolic agents, facilitating dissection at extended hepatectomy. In conclusion, ipsilateral transhepatic PVE using a single nitinol plug in combination with histoacryl glue and iodinized oil simplifies the procedure, offering short procedural times with minimal risk of nontarget embolization. Excellent levels of FLR hypertrophy are achieved enabling safe extended hepatectomy.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Transcatheter Embolization for Delayed Hemorrhage Caused by Blunt Splenic Trauma

Although the exact benefit of adjunctive splenic artery embolization (SAE) in the nonoperative management (NOM) of patients with blunt splenic trauma has been debated, the role of transcatheter embolization in delayed splenic hemorrhage is rarely addressed. The purpose of this study was to evaluate the effectiveness of SAE in the management of patients who presented at least 3 days after initial splenic trauma with delayed hemorrhage. During a 24-month period 4 patients (all male; ages 19-49 years) presented with acute onset of pain 5-70 days after blunt trauma to the left upper quadrant. Two had known splenic injuries that had been managed nonoperatively. All had computed axial tomography evidence of active splenic hemorrhage or false aneurysm on representation. All underwent successful SAE. Follow-up ranged from 28 to 370 days. These cases and a review of the literature indicate that SAE is safe and effective for NOM failure caused by delayed manifestations of splenic arterial injury.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Total Percutaneous Aortic Repair: Midterm Outcomes

The purpose of this study was to examine the immediate and midterm outcomes of percutaneous endovascular repair of thoracic and abdominal aortic pathology. Between December 2003 and June 2005, 21 patients (mean age: 60.4 {+-} 17.1 years; 15 males, 6 females) underwent endovascular stent-graft insertion for thoracic (n = 13) or abdominal aortic (n = 8) pathology. Preprocedural computed tomographic angiography (CTA) was performed to assess the suitability of aorto-iliac and common femoral artery (CFA) anatomy, including the degree of CFA calcification, for total percutaneous aortic stent-graft repair. Percutaneous access was used for the introduction of 18- to 26-Fr delivery devices. A 'preclose' closure technique using two Perclose suture devices (Perclose A-T; Abbott Vascular) was used in all cases. Data were prospectively collected. Each CFA puncture site was assessed via clinical examination and CTA at 1, 6, and 12 months, followed by annual review thereafter. Minimum follow-up was 36 months. Outcome measures evaluated were rates of technical success, conversion to open surgical repair, complications, and late incidence of arterial stenosis at the site of Perclose suture deployment. A total of 58 Perclose devices were used to close 29 femoral arteriotomies. Outer diameters of stent-graft delivery devices used were 18 Fr (n = 5), 20 Fr (n = 3), 22 Fr (n = 4), 24 Fr (n = 15), and 26 Fr (n = 2). Percutaneous closure was successful in 96.6% (28/29) of arteriotomies. Conversion to surgical repair was required at one access site (3.4%). Mean follow-up was 50 {+-} 8 months. No late complications were observed. By CT criteria, no patient developed a >50% reduction in CFA caliber at the site of Perclose deployment during the study period. In conclusion, percutaneous aortic stent-graft insertion can be safely performed, with a low risk of both immediate and midterm access-related complications.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Use of Intra-Arterial Chemotherapy and Embolization Before Limb Salvage Surgery for Osteosarcoma of the Lower Extremity

We report our experience with the use of intra-arterial chemotherapy and embolization before limb salvage surgery in patients with osteosarcoma of the lower extremity. We evaluated the effect of this procedure on the degree of tumor necrosis and on the amount of blood loss during surgery. We reviewed the medical records of all patients who received intra-arterial chemotherapy and embolization before undergoing limb salvage surgery for osteosarcoma of the lower extremity at our institution between January 2003 and April 2008. Patient demographic, tumor characteristics, treatment details, postembolization complications, and surgical and pathological findings were recorded for each patient. We evaluated the operative time, estimated blood loss (EBL), and volume of blood transfusion during surgery and in the postoperative period in all patients in the study group. The same parameters were recorded for 65 other patients with lower extremity osteosarcoma who underwent limb salvage operation at our institution without undergoing preoperative intervention. The study included 47 patients (25 males and 22 females). Angiography showed that the tumors were hypervascular. Intra-arterial chemotherapy and embolization were performed successfully, resulting in a substantial reduction or complete disappearance of tumor stain in all patients. No major complications were encountered. At the time of surgery, performed 3-7 days after embolization, a fibrous edematous band around the tumor was observed in 43 of the 47 patients, facilitating surgery. The goal of limb salvage was achieved successfully in all cases. Percentage tumor necrosis induced by treatment ranged from 70.2% to 94.2% (average, 82.9%). EBL during surgery, EBL from drains in the postoperative period, total EBL, and transfusion volumes were significantly lower in the 47 study patients compared to the 65 patients who underwent surgery without preoperative treatment with intra-arterial chemotherapy and embolization. The mean operative time was also significantly less in the intervention group compared to the nonintervention group (73.2 vs. 88.5 min; p < 0.05). In conclusion, intra-arterial chemotherapy and embolization performed 3 to 7 days before limb salvage surgery in patients with lower extremity osteosarcomas can cause substantial tumor necrosis, reduce the EBL and transfusion requirements during surgery, and induce formation of a false capsule around the tumor, thus facilitating surgical excision of the tumors.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Treatment of Venous Aortorenal Bypass Graft Aneurysm Using a Stent-Graft

We present the case of a 77-year-old male patient who had undergone a bilateral venous aortorenal bypass graft 30 years previously. Thirteen years previously, the patient was shown to have a decrease in renal function, with mild shrinking of both kidneys; additionally, a stenosis was found in the left proximal anastomosis. At the most recent follow-up visit (1 year previously), ultrasound revealed an aneurysm (42 mm in diameter) of the left renal bypass graft; the finding was confirmed by CT angiography. A significant ostial stenosis of the left renal bypass graft was also confirmed. It was decided to place a self-expandable stent-graft into the aneurysm while also attempting to dilate the stenosis. Proximal endoleak after stent-graft placement necessitated the implantation of another, balloon-expandable stent-graft into the bypass graft ostium. Postprocedural angiography and follow-up by CT angiography at 3 months confirmed good patency of the stent-grafts and complete thrombosis of the aneurysmal sac, with preserved kidney perfusion. Renal function remained unaltered, while the hypertension is better controlled.

62 RADIOLOGY AND NUCLEAR MEDICINE↗