Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Low Resolution”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,153 records · Page 64

Plasma characteristics of the Io torus

Simultaneous, low spectral resolution measurements of the following Jovian plasma torus forbidden emission lines show the occurrence of significant changes in characteristics on a time scale of days: S II 4069, 4076 A; S II 6716, 6731 A; S III 3722 A; and O II 3726, 3729 A. The O II emission is more extensive in magnetic latitude than the S II emission, which is the expected result of the mass difference between the ions if they have a common temperature. The S II and O II lines yield independent and consistent values for the average electron density, and variations about this average are larger than the measurement uncertainties. Unusual spectra in which the blue, but not the red S II forbidden lines are present indicate transient conditions of high plasma density and low electron temperature.

Morgan, J. S.↗

Critical Evaluation of 0-30 km Profile Information in Ground-Based Zenith-Sky and Satellite-Measured Backscattered UV Radiation

We now have several decades of experience in deriving vertical ozone profiles from the measurements of diffuse ultraviolet radiation by both ground and satellite-based instruments using Umkehr and BUV techniques. Continuing technological advances are pushing the state-of-the-art of these measurements to high spectral resolution and broader wavelength coverage. These modern instruments include the ground-based Brewer and satellite-based Global Ozone Monitoring Experiment (GOME) instruments, as well as advanced instruments being developed by ESA(SCIAMACHY), Netherlands(OMI) and Japan(ODUS). However, one of the issues that remains unresolved is the 0-30 km ozone profile information retrievable from these measurements. Though it is commonly believed that both the Umkehr and the satellite-based BUV techniques have very limited profile information below 30 km, there are those who argue that the data from these instruments should continue to be reported in this altitude range for they compare well with ozonesondes and hence there is useful scientific information. Others claim that the limitations of the Umkehr and BUV techniques are largely due to their low spectral resolution, and that the profile information below 30 km can be greatly improved by going to high spectral resolution instruments, such as Brewer and GOME. The purpose of this paper is to provide a critical evaluation of the 0-30 km ozone profile information in the various UV remote sensing techniques. We use a database of individual ozone profiles created using ozonesondes and SAGE and 4D ozone fields generated by data assimilation techniques to simulate radiances measured by the various techniques. We then apply a common inversion approach to all the methods to systematically examine how much profile information is available simply from the knowledge of total ozone, how much additional profile information is added by the traditional Dobson Umkehr and satellite buv techniques, and how much better one can do by adding additional wavelengths and by going to higher spectral resolution. An open and honest discussion of these issues is critical to provide the ozone science community a realistic assessment of the quality of data in the lower stratosphere and troposphere expected from both past and future instruments.

Bhartia, Pawan↗

Scale Dependence of Cirrus Horizontal Heterogeneity Effects on TOA Measurements: MODIS Brightness Temperatures in the Thermal Infrared - Part I

This paper presents a study on the impact of cirrus cloud heterogeneities on MODIS simulated thermal infrared (TIR) brightness temperatures (BTs) at the top of the atmosphere (TOA) as a function of spatial resolution from 50 meters to 10 kilometers. A realistic 3-D (three-dimensional) cirrus field is generated by the 3DCLOUD model (average optical thickness of 1.4, cloudtop and base altitudes at 10 and 12 kilometers, respectively, consisting of aggregate column crystals of D (sub eff) equals 20 microns), and 3-D thermal infrared radiative transfer (RT) is simulated with the 3DMCPOL (3-D Monte Carlo Polarized) code. According to previous studies, differences between 3-D BT computed from a heterogenous pixel and 1-D (one-dimensional) RT computed from a homogeneous pixel are considered dependent at nadir on two effects: (i) the optical thickness horizontal heterogeneity leading to the plane-parallel homogeneous bias (PPHB); and the (ii) horizontal radiative transport (HRT) leading to the independent pixel approximation error (IPAE). A single but realistic cirrus case is simulated and, as expected, the PPHB mainly impacts the low-spatial resolution results (above approximately 250 meters), with averaged values of up to 5-7 K (thousand), while the IPAE mainly impacts the high-spatial resolution results (below approximately 250 meters) with average values of up to 1-2 K (thousand). A sensitivity study has been performed in order to extend these results to various cirrus optical thicknesses and heterogeneities by sampling the cirrus in several ranges of parameters. For four optical thickness classes and four optical heterogeneity classes, we have found that, for nadir observations, the spatial resolution at which the combination of PPHB and HRT effects is the smallest, falls between 100 and 250 meters. These spatial resolutions thus appear to be the best choice to retrieve cirrus optical properties with the smallest cloud heterogeneity-related total bias in the thermal infrared. For off-nadir observations, the average total effect is increased and the minimum is shifted to coarser spatial resolutions.

TOA↗

Retrieval of Cloud Liquid Water Using Microwave Signals from LEO Satellites: A Feasibility Study through Simulations

A novel method, using low Earth orbit (LEO) satellite microwave communication links for cloud liquid water measurements, is introduced in this paper. The feasibility of this approach is studied through simulations of the retrieval system including a LEO satellite communicating with a group of ground receivers equipped with signal-to-noise ratio (SNR) estimators, a synthetic cloud attenuation field and a tomographic retrieval algorithm. Rectangular and Gaussian basis functions are considered to define the targeted field. Simulation results suggest that the proposed least-squares based retrieval algorithm produces satisfactory outcomes for both types of basis functions. The root-mean-square error of the retrieved field is around 0.2 dB/km, with the range of the reference field as 0 to 2.35 dB/km. It is also confirmed that the partial retrieval of the cloud field is achievable when a limited number of receivers with restricted locations are available. The retrieval outcomes exhibit properties of high resolution and low error, indicating that the proposed approach has great potential for cloud observations.

54 ENVIRONMENTAL SCIENCES↗

UV laser long-path absorption spectroscopy

Long path Differential Optical Absorption Spectroscopy (DOAS) using a picosecond UV laser as a light source was developed in our institute. Tropospheric OH radicals are measured by their rotational absorption lines around 308 nm. The spectra are obtained using a high resolution spectrograph. The detection system has been improved over the formerly used optomechanical scanning device by application of a photodiode array which increased the observed spectral range by a factor of 6 and which utilizes the light much more effectively leading to a considerable reduction of the measurement time. This technique provides direct measurements of OH because the signal is given by the product of the absorption coefficient and the OH concentration along the light path according to Lambert-Beers law. No calibration is needed. Since the integrated absorption coefficient is well known the accuracy of the measurement essentially depends on the extent to which the OH absorption pattern can be detected in the spectra. No interference by self generated OH radicals in the detection lightpath has been observed. The large bandwidth (greater than 0.15 nm) and the high spectral resolution (1.5 pm) allows absolute determination of interferences by other trace gas absorptions. The measurement error is directly accessible from the absorption-signal to baseline-noise ratio in the spectra. The applicability of the method strongly depends on visibility. Elevated concentrations of aerosols lead to considerable attenuation of the laser light which reduces the S/N-ratio. In the moderately polluted air of Julich, where we performed a number of OH measurement spectra. In addition absorption features of unidentified species were frequently detected. A quantitative deconvolution even of the known species is not easy to achieve and can leave residual structures in the spectra. Thus interferences usually increase the noise and deteriorate the OH detection sensitivity. Using diode arrays for sensitive absorption measurements some specific problems of those detectors have to be solved experimentally (i.e. fixed pattern noise, dark signal noise, nonuniform efficiency of individual elements, spatial sensitivity variations). In order to improve the low spatial resolution we performed laboratory studies using a multiple reflection cell to convert the long path technique to a real in situ point measurement. Under the conditions of field experiments in Julich residual absorbance signals at present are about 1.5x10(exp -4) corresponding to an OH detection sensitivity of 2x10(exp 6) OH/cm(exp 3) using a light path of 5.8 km. Total integration times for one measurement point vary between a few minutes and an hour.

Dorn, Hans-Peter↗

New Measurements of the Lyα Forest Continuum and Effective Optical Depth with LyCAN and DESI Y1 Data

Abstract We present the Ly α Continuum Analysis Network (LyCAN), a convolutional neural network that predicts the unabsorbed quasar continuum within the rest-frame wavelength range of 1040–1600 Å based on the red side of the Ly α emission line (1216–1600 Å). We developed synthetic spectra based on a Gaussian mixture model representation of nonnegative matrix factorization (NMF) coefficients. These coefficients were derived from high-resolution, low-redshift ( z < 0.2) Hubble Space Telescope/Cosmic Origins Spectrograph (COS) quasar spectra. We supplemented this COS-based synthetic sample with an equal number of DESI Year 5 mock spectra. LyCAN performs extremely well on testing sets, achieving a median error in the forest region of 1.5% on the DESI mock sample, 2.0% on the COS-based synthetic sample, and 4.1% on the original COS spectra. LyCAN outperforms principal component analysis (PCA) and NMF-based prediction methods using the same training set by 40% or more. We predict the intrinsic continua of 83,635 DESI Year 1 spectra in the redshift range of 2.1 ≤ z ≤ 4.2 and perform an absolute measurement of the evolution of the effective optical depth. This is the largest sample employed to measure the optical depth evolution to date. We fit a power law of the form τ ( z ) = τ 0 ( 1 + z ) γ to our measurements and find τ 0 = (2.46 ± 0.14) × 10 −3 and γ = 3.62 ± 0.04. Our results show particular agreement with high-resolution, ground-based observations around z = 2, indicating that LyCAN is able to predict the quasar continuum in the forest region with only spectral information outside the forest.

79 ASTRONOMY AND ASTROPHYSICS↗

Confirmation of a Steep Luminosity Function for Ly alpha Emitters at z 5.7: a Major Component of Reionization

We report the first direct and robust measurement of the faint-end slope of the Ly-alpha emitter (LAE) luminosity function at z = 5.7. Candidate LAEs from a low-spectral-resolution blind search with IMACS on Magellan- Baade were targeted at higher resolution to distinguish high redshift LAEs from foreground galaxies. All but 2 of our 42 single-emission-line systems are fainter than F = 2.0×10(exp−17) ergs s(exp−1) cm(exp−2), making these the faintest emission-lines observed for a z = 5.7 sample with known completeness, an essential property for determining the faint end slope of the LAE luminosity function. We find 13 LAEs as compared to 29 foreground galaxies, in very good agreement with the modeled foreground counts predicted in Dressler et al. (2011a) that had been used to estimate a faint-end slope of alpha = −2.0 for the LAE luminosity function. A 32% LAE fraction, LAE/(LAE+foreground) within the flux interval F = 2−20 × 10(exp−18) ergs s(exp−1) cm(exp−2) constrains the faint end slope of the luminosity function to −1.95 greater than alpha greater than −2.35 (1 delta). We show how this steep LF should provide, to the limit of our observations, more than 20% of the flux necessary to maintain ionization at z = 5.7, with a factor-of-ten extrapolation in flux reaching more than 55%. We suggest that this bodes well for a comparable contribution by similar, low-mass star forming galaxies at higher-redshift - within the reionization epoch at z greater than approximately 7, only 250 Myr earlier - and that such systems provide a substantial, if not dominant, contribution to the late-stage reionization of the IGM.

STEEP↗

Thermal signatures of urban land cover types: High-resolution thermal infrared remote sensing of urban heat island in Huntsville, AL

The main objective of this research is to apply airborne high-resolution thermal infrared imagery for urban heat island studies, using Huntsville, AL, a medium-sized American city, as the study area. The occurrence of urban heat islands represents human-induced urban/rural contrast, which is caused by deforestation and the replacement of the land surface by non-evaporating and non-porous materials such as asphalt and concrete. The result is reduced evapotranspiration and more rapid runoff of rain water. The urban landscape forms a canopy acting as a transitional zone between the atmosphere and the land surface. The composition and structure of this canopy have a significant impact on the thermal behavior of the urban environment. Research on the trends of surface temperature at rapidly growing urban sites in the United States during the last 30 to 50 years suggests that significant urban heat island effects have caused the temperatures at these sites to rise by 1 to 2 C. Urban heat islands have caused changes in urban precipitation and temperature that are at least similar to, if not greater than, those predicted to develop over the next 100 years by global change models. Satellite remote sensing, particularly NOAA AVHRR thermal data, has been used in the study of urban heat islands. Because of the low spatial resolution (1.1 km at nadir) of the AVHRR data, these studies can only examine and map the phenomenon at the macro-level. The present research provides the rare opportunity to utilize 5-meter thermal infrared data acquired from an airplane to characterize more accurately the thermal responses of different land cover types in the urban landscape as input to urban heat island studies.

Lo, Chor Pang↗

Grating-Based Imaging-Scattering with Portable Neutron Generator

Company: Adelphi Technology, Inc. Title: Grating-Based Imaging-Scattering with Portable Neutron Generator PI: Dr. Jay Theodore Cremer, Jr. Topic: 26a Statement of the problem or situation that is being addressed. Successful plant growth depends upon an efficient and robust root system. The plant root is part of a larger system of water and microbial flows in the soil system. While much effort has been exerted to develop an imaging system for water, microbes, and roots, the problem is challenging, and no widely accepted imaging method currently exists. The optical solutions use a highly modified soil system. X-ray imaging methods are insensitive to the soft tissues in the presence of sand. Thermal neutron imaging has been often tested, but found inadequate, due to limited access and low image resolution. This project will develop a new strategy for neutron imaging of plant/soil systems. The project will allow long duration experiments in greenhouse environments and increase the image information content to the micron scale. General statement of how this problem is being addressed. Portable, rugged thermal and fast neutron sources are being developed where portable means a two-soldier team can carry the source and power unit to survey rough terrain for explosives. In the past decade, microfabrication of X-ray and thermal/cold neutron optics has opened a new imaging strategy. The standard transmission image is now supplemented with simultaneous acquisition of a phase contrast image and an image revealing scattering features. In materials science, the interferometric neutron scattering image has been used to detect early crack formation in stressed additive manufacturing test samples. The detection requires sensitivity to scattering features at the 1-micron scale. By addition of our proposed grating-optic to Adelphi Technology’s radiographic/tomographic imaging system, which is based on portable thermal neutron source, the resulting thermal neutron scatter image of the plant/soil system, will reveal details at 1-micron. Commercial Applications and Other Benefits Neutron interferometry imaging has greater penetration through large metal components compared to industrial X-ray imaging. The low-cost, large area optics developed for greenhouse applications, combined with the robust, portable neutron generator, can then be marketed as a system for inspection of additive manufactured components. In the aerospace industry, all freshly printed components are validated with X-ray CT. Scheduled maintenance again requires X-ray CT as the ability to predict aerospace component lifetime does not yet exist. Large aerospace components are only partially observed with X-ray imaging. Key Words Neutron radiography/tomography, grating interferometry, thermal neutron generator imaging, plant root and soil imaging, rhizosphere imaging, deployable neutron imaging systems Summary for Members of Congress A rugged, portable source of thermal neutrons is adapted for neutron interferometry imaging with the addition of low-cost, 3D printed optics. The first application of our proposed deployable, compact thermal neutron generator imaging system, using a grating optic, is plant root/soil science in greenhouse settings and agricultural laboratories.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Spectral Induced Polarization-Biogeochemical Relationships for Remediation Amendment Monitoring

Geophysical tools such as electrical resistivity (ER) can indirectly monitor subsurface changes in response to remedial injections. These methods exhibit relatively low spatial resolution compared to sediment core characterization but are advantageous due to the ability to collect measurements non-intrusively over time across large volumes of the subsurface. Moreover, along with confirmatory groundwater or core sampling, geophysical methods can be used during active biogeochemical remedies to monitor short-term contaminant transformations and mobility, as well as part of an overall strategy for long-term monitoring of subsurface contaminated sites. The use of alternating current spectral induced polarization (SIP) provides significantly more information than conventional geophysical methods like direct current ER. SIP allows for monitoring changes in both solution and surface conductivity by separation of real and imaginary conductivity, respectively, as well as surface capacitance. In principle, SIP can measure indicators of remedy progression such as precipitation reactions that sequester contaminants, potentially providing a better indication of amendment delivery and reactivity as compared to conventional ER methods. However, multiple processes and material properties have overlapping (interacting) electrical responses across a range of frequencies. Hence, the purpose of this scoping study was to evaluate if SIP can be used to monitor (a) amendment delivery and (b) precipitation and reactivity of amendments under consideration at Hanford. SIP measurements were collected in fully saturated columns packed with sand and Hanford formation sediments containing (a) amendments that were highly conductive with significant capacitance (zero valent iron – ZVI, sulfur modified iron – SMI) and (b) amendments that exhibited low electrical conductivity with a small capacitance (calcite, apatite, bismuth). The sand was a quartz material with homogenous particle size that exhibited a relatively low surface conductivity. It was used as a control for comparison with the sediments from the Hanford Site, which have a greater surface conductivity because of their complex mineralogy and heterogeneous particle size distribution and may have complex interactions with amendments. The amendment mass fraction was varied to represent the different stages and subsurface locations associated with the delivery of a remedy. The primary objective was to identify the solution and solid surface changes associated with the delivery amendments and their secondary reactions within the subsurface. The figure below summarizes results for the amendments tested through this project. The SIP phase shift or imaginary conductivity change for the high conductivity amendments was more than 10 times that of the low conductivity amendments, highlighting the relative ease of detection of ZVI and SMI independent of the background signal from sand or Hanford sediments. The ZVI phase shift and imaginary conductivity changes occur primarily at high frequency (> 100 Hz) whereas SMI changes were at low frequency (0.01 to 10 Hz). SIP signals of SMI also increased over time and the maximum shifted to lower frequencies. The low conductivity amendments (calcite, abiotic and biotic apatite, bismuth subnitrate) exhibited relatively small phase and imaginary conductivity changes when added to sediments. The changes were above minimum detection limits (0.5 mrad for phase shift, 0.03 µS/cm for imaginary conductivity) for the highest concentration except for the commercial bismuth material. The lowest amendment concentration that can be detected is likely sediment specific, as minerals in sediments (clays, magnetite, Fe-oxides) have some capacitance and, therefore, exhibit a variable phase shift.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Cassini/CIRS Observations of Water Vapor in Saturn's Stratosphere

The Composite Infrared Spectrometer (CIRS) on the Cassini spacecraft has obtained numerous spectra of Saturn at varying spectral and spatial resolutions since Saturn Orbit Insertion in 2004. Emission lines due to water vapor in Saturn's stratosphere were first detected using whole-disk observations from the Infrared Space Observatory (Feuchtgruber et al 1997) and subsequently confirmed by the Submillimeter Wave Astronomy Satellite (Rergin et al 2000). CIRS has detected water and the data permit the retrieval of the latitudinal variation of water on Saturn. Emission lines of H2O on Saturn are very weak in the CIRS data. Thus. large spectral averages as well as improvements in calibration are necessary to detect water vapor. Zonally averaged nadir spectra were produced every 10 degrees of latitude. Stratospheric temperatures in the 0.5 - 5.0 mbar range were obtained by inverting spectra of CH4 in the v4 band centered at 1304 cm(exp -1). The origin of water vapor is believed to be from the ablation of micrometeorites containing water ice, followed by photochemistry. This external source of oxygen originates either from the Saturn system (from the rings or perhaps from Enceladus) or from the interplanetary medium. Connerney (1986) proposed a mechanism to transport water from the inner edge of the B-ring along magnetic field lines to specific latitudes (50N and 44S) on Saturn. Prange et al (2006) interpreted a minimum in the abundance of acetylene from ultraviolet spectra near 41S on Saturn as possibly due to an enhanced influx of water. Existing CIRS far-IR spectra are at relatively low spatial resolution, but observations at closer range planned for the extended mission will be able to test the "ring rain" mechanism by searching for localized water vapor enhancement at midlatitudes.

Bjoraker, G. L.↗

Investigation of Magmatic Activities on Early Mars Using Igneous Mineral Chemistry in Gale Crater, Mars

One objective of rover missions is exploring the geological context of the surroundings. Over the years, igneous petrology and sedimentology have been disconnected, the first investigating magmatic processes and volcanic activities, and the second seeking environmental conditions in the past and assessing the habitability of the planet. Although different, one is related to the other: igneous rocks are altered and broken down, leading to the formation of sedimentary rocks, which can in turn be used to back out the nature of their magmatic source. The Curiosity rover that landed in the 3.7 Gyr old impact crater Gale is traveling through sedimentary rocks. About fifty float rocks have been observed, and several of them with ambiguous texture and composition have been classified as igneous or sedimentary depending on studies such as Jake_M. The composition of several unambiguous igneous rocks has been analyzed [4- 6] but their heterogeneity at a larger instrumental (measurement size < 2 cm) scale prevents the measurement of a bulk composition as performed on Earth. An original approach avoiding these two last issues is to consider igneous mineral chemistry analyzed within igneous and sedimentary rocks to assess magmatic processes that could have formed them. Most Curiosity data are used to explore ancient environmental conditions, and a significant number of compositional analyses are under-explored for constraining magmatic activities. We will present how we can make use of sedimentary data for investigating igneous processes in the vicinity of Gale crater. Geological Context: We focus on the first 750 martian days, corresponding to measurements in a coherent lacustrine sedimentary unit called Bradbury, because all sedimentary rocks were sourced from the same watershed and appear to have a consistent source with minimal alteration [2-3]. Igneous detrital minerals including feldspar and pyroxene, are observed in sedimentary rocks. Monte Carlo models showed that minimal cation loss is observed based on the composition of all Bradbury rocks, implying negligible weathering [3]. Although clay minerals are detected in few rocks [7], chemical compositions of rocks can be explained by a mixture of primary igneous minerals [3]. Variation of composition within Bradbury rocks can be explained by mineral sorting and one distinct source component. While a common magmatic source is suggested, Bradbury sediments likely come from several volcanic eruptions from a single magmatic chamber [9- 10]. The occurrence of alkali minerals like sanidine and K-rich rocks throughout Bradbury supports the presence of a potassic component, likely trachytic, while plagioclase and a mafic composition suggest a basaltic component [8-9]. Instruments: Mineral chemistry can be estimated by three instruments onboard Curiosity. The CheMin instrument enables detection of mineral assemblages using X-ray diffraction (XRD). Using Rietveld refinement, each mineral is identified according to their 1D XRD pattern [11]. Note that distinction between pyroxene minerals is challenging with the CheMin instrument due to overlapping peaks on XRD patterns and low angular resolution of the instrument [12]. Then, using least square regression and optimization algorithms based on unit-cell parameters, mineral chemistry has been estimated by [11]. Plagioclase composition has been estimated using the NaAlSi3O8- CaAl2Si2O8 system and alkali feldspar is based on the NaAlSi3O8-KAlSi3O8 system (stars in Fig.1). Two mudstone samples (John Klein and Cumberland) and one sandstone sample (Windjana) were analyzed by CheMin at Yellowknife Bay and Kimberley, respectively. Figure 1. Ternary diagrams of feldspars (top) and pyroxene (bottom) quadrilateral. Stars correspond to CheMin composition and the gray patches to ChemCam composition. The colored dots are the composition of feldspar and pyroxene that crystallized during fractional crystallization at FMQ+1 of a melt extracted at distinct melting degree during the adiabatic ascent of a primitive mantle composition, without any water (left panels) and with 0.5 wt.% of water (right panels) at distinct pressure. The ChemCam instrument enables the analysis of the chemical compositions of rocks at hundreds of micrometer scale (350-550 μm) using laser induced breakdown spectroscopy (LIBS), which may provide the composition of minerals when they are larger than the beam spot (>550 μm) [13]. Within >5000 LIBS points, we performed a typical stoichiometric filtering allowing us to distinguish 56 feldspar and 10 pyroxene mineral compositions (grey patches in Fig. 1). Finally, the Alpha Particle X-ray Spectrometer (APXS) analyzes the composition of rocks with a 1.6 cm diameter spot size. Monte Carlo mass balance modeling allowed [3] to decipher a feldspar range varying between An30 and An40 (Fig. 1). Discussion: Although there could be a more complex history and other ways to form the whole compositional range of igneous minerals analyzed within the Bradbury formation, we are presenting here simple magmatic pathways commonly occurring on Earth using the thermodynamical softwares pMELTS and rhyoliteMELTS [14]. The objective is to find reasonable igneous processes that produce minerals that parallel the compositions of feldspar and pyroxene analyzed by the Curiosity rover. As commonly observed for mid-ocean ridge basalts, the adiabatic ascent of a primitive mantle composition [15] partially melting at 2 GPa has been modeled, followed by the extraction of a liquid at distinct degrees of partial melting, which undergoes fractional crystallization at an oxygen fugacity +1 log unit above the fayalite-magnetite-quartz (FMQ) buffer within the crust (0.02-0.4 GPa) with H2O = 0- 0.5 wt. %. These latter conditions correspond to those recorded within igneous clasts from the Noachian martian breccia NWA 7034 and paired and within Gale igneous rocks (colored dots in Fig. 1) [16-17]. To check the reliability of these 2-step models, we also tested fractional crystallization at similar conditions (FMQ+1; P=0.02-0.4 GPa; H2O = 0-0.5 wt. %) of starting compositions corresponding to that of magmas with distinct melting degrees obtained from isobaric experiments at 2 GPa [18]. Mineral compositions obtained from both models are similar. As shown on Fig. 1, the whole range of observed feldspar compositions cannot be reproduced by fractionation of one magma only. Indeed, while alkali feldspar and Na-plagioclase likely crystallized from fractional crystallization of a low-degree melt (here <15%), plagioclase and pyroxene can only be formed by fractional crystallization of a higher degree melt (here >19%). The corresponding liquid descent lines are broadly in agreement with compositions estimated by ChemCam corresponding to float igneous rocks (Fig. 2) [4-6]. Figure 2. Silica versus alkali content. Lines show the liquid lines of descent from magmas with distinct degrees of melting. Gray patches represents the composition of Gale igneous rocks [4-6]. Trachytic to rhyolitic magmas crystallize alkali feldspar, and andesite to dacite magmas likely form plagioclase. Therefore, at least two starting magmas at distinct melting degrees, which could easily come from a single mantle source, are necessary to explain the whole compositional range of feldspar and pyroxene analyzed within Bradbury rocks. Conclusion: Because rocks from the Bradbury formation are likely originating from the same magmatic source with minimal weathering as supported by several studies using different approaches, igneous mineral chemistry analyzed by CheMin and ChemCam allows us to back out reasonable magmatic pathways that could have crystallized them. Fractional crystallization of at least two starting magmas originating from distinct melting degrees of a single mantle source can explain the whole range of feldspar and pyroxene composition. Both alkaline and sub-alkaline liquids can be produced, with compositions corresponding to those of the igneous rocks analyzed by ChemCam within the Bradbury formation, highlighting the complexity of Mars magmatism.

Payre, V.↗

Comparison of greenhouse gas emission estimates from six hydropower reservoirs using modeling versus field surveys

As with most aquatic ecosystems, reservoirs play an important role in the global carbon (C) cycle and emit greenhouse gases (GHG) as carbon dioxide (CO 2 ) and methane (CH 4 ). However, GHG emissions from reservoirs are poorly quantified, especially in temperate systems, resulting in high uncertainty. We compared reservoir C emission estimates and uncertainty of diffusive, ebullitive, and degassing pathways in six hydropower reservoirs in the southeastern United States among four data sources: two field-based surveys and two models (including the GHG Reservoir “G-res” Tool). We found that CH 4 diffusion was most similar across data sources (modeled minus observed, bias = - 21 g CO 2-eq m -2 y -1 ) and had low relative uncertainty (coefficient of variation, CV = 0.98). On the other hand, CO 2 diffusion was least consistent across data sources (bias = - 518 g CO 2-eq m -2 y -1 ). Both field surveys indicated strong negative CO 2 diffusion (i.e., CO 2 uptake) at all reservoirs, while G-res estimated positive CO 2 diffusion. By extension, total C emissions showed similar discrepancies, leading to high uncertainty in upscaling and interpreting reservoir source-sink dynamics. Finally, CH 4 ebullition had the highest relative uncertainty (CV = 2.77) due to high variability across sites. We discuss limitations of field surveys and these models, including temperature-based annualization methods, varying definitions of ebullition zones, low sampling resolution, and lack of dynamism. Future field efforts focused on capturing variability in CO 2 diffusion and CH 4 ebullition will be especially valuable in reducing uncertainty and improving models to advance our understanding reservoir GHG emissions.

54 ENVIRONMENTAL SCIENCES↗

Accuracy and precision of ESI-Orbitrap-IRMS observations of hours to tens of hours via reservoir injection

Here, orbitrap isotope ratio mass spectrometry (Orbitrap-IRMS) has recently been applied to high-precision, natural-abundance isotope ratio measurements of a diverse range of compounds, including amino acids, oxyanions, fatty acids, and metals. These measurements can characterize many isotope ratios simultaneously at high (≈1.0‰) precision. In a successful experiment, observed precision will track the shot-noise limit and be limited by experimental time. Some isotope ratios, for example those involving 17 O in organic compounds or multiply-substituted (‘clumped’) isotopologues, require experimental times of hours to tens of hours to achieve desired precision, while current sample introduction techniques focus on observations on the order of seconds to tens of minutes. In this study, we characterize Orbitrap-IRMS performance for three long duration measurements (individual acquisitions ≥1 h and as long as 24 h) using an automated reservoir injection system coupled to a Q Exactive HF Orbitrap with an electrospray ionization (ESI) source. First, we characterize long-term intra-measurement stability through a 24-h long measurement of acetone. We report the following isotope ratios and precisions (as acquisition errors, errors on the observed ratio within this measurement (σ AE )): 13 C/ 12 C (σ AE = 0.07‰), 17 O/ 16 O (σ AE = 1.1‰), 18 O/ 16 O (σ AE = 0.3‰), and 13 C 13 C/ 12 C (σ AE = 0.65‰). The σ AE of each tracks the shot noise limit throughout and is limited by the challenging conditions (high resolution and low numbers of ions per scan) required for 17 O/ 16 O measurement in the presence of 13 C via Orbitrap. Second, we characterize inter-measurement stability via a sequence of seven 75-min analyses of perchlorate. We observe the following ratios and acquisition errors: 37 Cl/ 35 Cl (σ AE = 0.09‰); 17 O/ 16 O (σ AE = 1.6‰); 18 O/ 16 O (σ AE = 0.7‰), 37 Cl 17 O/ 35 Cl 16 O (σ AE = 2.7‰), and 37 Cl 18 O/ 35 Cl 16 O (σ AE = 1.2‰). However, we find that inter-measurement drift between acquisitions limits our accuracy and precision for standardized measurements (i.e., error on reported δ values) to ≈1‰ for the 37 Cl/ 35 Cl measurement. Hence, the benefits of low σ AE may not be fully realized. Third, we demonstrate accuracy via sample/standard comparisons of a methionine sample with 13 C enrichment of ≈20‰ relative to a known standard. Using a sequence of seven 60-min analyses, we recover the following isotope ratios and standardized precisions (i.e., error on reported δ values, denoted propagated acquisition errors, σ PAE ): 33 S/ 32 S (σ PAE = 1.0‰), 34 S/ 32 S (σ PAE = 0.7‰), 15 N/ 14 N (σ PAE = 2.1‰), 2 H/ 1 H (σ PAE = 3.2‰), 13 C/ 12 C (σ PAE = 0.4‰), 18 O/ 16 O (σ PAE = 1.6‰), & 13 C 13 C/ 12 C (σ PAE = 2.8‰) with confirmation of accurate results for the known 13 C/ 12 C and 13 C 13 C/ 12 C enrichments. Together, our results demonstrate the viability of Orbitrap-IRMS for long duration measurements of diverse sample types via an automated reservoir injection system. Inter-measurement stability remains a challenge; we expect our methods to be most applicable to extended measurements of hard-to-observe properties, such as 17 O in organics and clumped isotopologues.

58 GEOSCIENCES↗

Distinguishing Mesoscale Polar Order (Unidirectional vs Bidirectional) of Cellulose Microfibrils in Plant Cell Walls Using Sum Frequency Generation Spectroscopy

Cellulose in plant cell walls are synthesized as crystalline microfibrils with diameters of 3–4 nm and lengths of around 1–10 μm. These microfibrils are known to be the backbone of cell walls, and their multiscale three-dimensional organization plays a critical role in cell wall functions including plant growth and recalcitrance to degradation. The mesoscale organization of microfibrils over a 1–100 nm range in cell walls is challenging to resolve because most characterization techniques investigating this length scale suffer from low spatial resolution, sample preparation artifacts, or inaccessibility of specific cell types. Here, we report a sum frequency generation (SFG) study determining the mesoscale polarity of cellulose microfibrils in intact plant cell walls. SFG is a nonlinear optical spectroscopy technique sensitive to the molecular-to-mesoscale order of noncentrosymmetric domains in amorphous matrices. However, the quantitative theoretical model to unravel the effect of polarity in packing of noncentrosymmetric domains on SFG spectral features has remained unresolved. In this work, we show how the phase synchronization principle of the SFG process is used to predict the relative intensities of vibrational modes with different polar angles from the noncentrosymmetric domain axis. Applying this model calculation for the first time and employing SFG microscopy, we found that cellulose microfibrils in certain xylem cell walls are deposited unidirectionally (or biased in one direction) instead of the bidirectional polarity which was believed to be dominant in plant cell walls from volume-averaged characterizations of macroscopic samples. Here, with this advancement in SFG analysis, one can now determine the relative polarity of noncentrosymmetric domains such as crystalline biopolymers interspersed in amorphous polymer matrices, which will open opportunities to study new questions that have not been conceived in the past.

36 MATERIALS SCIENCE↗

Feeling the Strain: Quantifying Ligand Deformation in Photosynthesis

Structural distortion of protein-bound ligands can play a critical role in enzyme function by tuning the electronic and chemical properties of the ligand molecule. However, quantifying these effects is difficult due to the limited resolution of protein structures and the difficulty of generating accurate structural restrains for non-protein ligands. Here, we seek to quantify these effects through a statistical analysis of ligand distortion in Chlorophyll (Chl) proteins (CP), where ring deformation is thought to play a role in energy and electron transfer. To assess the accuracy of ring-deformation estimates from available structural data, we take advantage of the C 2 symmetry of Photosystem II (PSII), comparing ring-deformation estimates for equivalent sites both within and between 113 distinct X-ray and Cryogenic electron microscopy (CryoEM) PSII structures. Significantly, we find that several deformation modes exhibit considerable variability in predictions, even for equivalent monomers, down to 2 Å resolution, to an extent that probably prevents their utilization in optical calculations. We further find that refinement restrains play a critical role in determining deformation values to resolution as low as 2 Å. However, for those modes that are well-resolved in the structural data, ring deformation in PSII is strongly conserved across all species tested, from cyanobacteria to algae. Furthermore, these results highlight both the opportunities and limitations inherent in the structure-based analysis of the bioenergetic and optical properties of CPs and other protein-ligand complexes.

14 SOLAR ENERGY↗

Enhanced Neutron and γ-Ray Detection via 6 Li Substitution in Undoped and Tl-Doped Zero-Dimensional Perovskite Cs 3 Cu 2 I 5 Scintillators

Radiation detectors are crucial in a wide variety of research and commercial applications, such as oil and gas exploration, medical imaging, nuclear nonproliferation, and homeland security. Neutron and gamma-ray detectors are fundamental components in portal monitors at ports and border crossings, bolstering national security against radiological threats. This study presents a dual-mode scintillator, undoped and Tl-doped 6 Li-Cs 3 Cu 2 I 5 , and demonstrates its potential as a promising material for simultaneous thermal neutron and gamma-ray detection. We explore the Bridgman growth of both undoped and thallium doped Li → Cu and Li → Cs substitutional systems with various Li doping levels and assess their impact on scintillation properties. Under 662 keV gamma-ray excitation, the undoped crystals had light yields up to 35,900 ph/MeV, with energy resolutions down to 4.5%. The Tl-doped crystals performed better than the undoped crystals with light yields peaking at 65,900 ph/MeV and energy resolutions as low as 3.5%. When exposed to a moderated 252 Cf excitation source, our crystals had light yields between 102,900 and 167,200 photons per thermal neutron capture, with a full energy thermal neutron peak reaching 3 MeV in gamma equivalent energy. Pulse shape discrimination studies reveal well-separated gamma and neutron events, resulting in Figure-Of-Merit (FOM) as high as 3.7. Furthermore, these findings highlight the potential of Li-doped Cs 3 Cu 2 I 5 as a viable candidate for next-generation dual-mode scintillators.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗