Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “LOADING RATE”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,153 records · Page 64

A consistent experimental protocol for the strain rate characterization of thermoplastic fabrics

Abstract This paper introduces an experimental procedure aiming at performing a consistent mechanical characterization of textile composites behavior, under static and dynamic loadings, and particularly their macroscopic strain rate‐dependent mechanisms. The procedure includes the design and validation of a reduced specimen adapted to dynamic testing, which guarantees the consistency of the identified macroscopic properties under a wide range of strain rates. An interrupted high speed tensile apparatus was also developed to investigate the strain rate sensitivity of the nonlinear constitutive behavior from = 10 − 4 s − 1 to 10 2 s − 1 . The originality of this experimental device lies in its ability to stop high speed loadings before ultimate failure, at adjustable, accurate strain levels. Finally, an extensive characterization campaign was performed. Results reveal a high strain rate dependency of the linear and nonlinear behavior. The procedure therefore generates consistent characterization data that may trustworthily be used for modeling purposes.

Coussa, Fabien↗

Rate Analysis of Two Photovoltaic Systems in San Diego

Analysts have found increasing evidence that rate structure has impacts on the economics of solar systems. This paper uses 2007 15-minute interval photovoltaic (PV) system and load data from two San Diego City water treatment facilities to illustrate impacts of different rate designs. The comparison is based on rates available in San Diego at the time of data collection and include proportionately small to large demand charges (relative to volumetric consumption), and varying on- and off- peak times. Findings are twofold for these large commercial systems: 1) transferring costs into demand charges does not result in savings and 2) changes in peak times do not result in a major cost difference during the course of a year. While lessons learned and discussion on rate components are based on the findings, the applicability is limited to buildings with similar systems, environments, rate options, and loads.

14 SOLAR ENERGY↗

Kinetic studies of the stress corrosion cracking of D6AC steel

The effect of load interactions on the crack growth velocity of D6AC steel under stress corrosion cracking conditions was determined. The environment was a 3.5 percent salt solution. The modified-wedge opening load specimens were fatigue precracked and subjected to a deadweight loading in creep machines. The effects of load shedding on incubation times and crack growth rates were measured using high-sensitivity compliance measurement techniques. Load shedding results in an incubation time, the length of which depends on the amount of load shed and the baseline stress intensity. The sequence of unloading the specimen also controls the subsequent incubation period. The incubation period is shorter when load shedding passes through zero load than when it does not if the specimen initially had the same baseline stress intensity. The crack growth rates following the incubation period are also different from the steady-state crack growth rate at the operating stress intensity. These data show that the susceptibility of this alloy system to stress corrosion cracking depends on the plane-strain fracture toughness and on the yield strength of the material.

Noronha, P. J.↗

Characterization of mode 1 and mixed-mode failure of adhesive bonds between composite adherends

A combined experimental and analytical investigation of an adhesively bonded composite joint was conducted to characterize both the static and fatigue beyond growth mechanism under mode 1 and mixed-mode 1 and 2 loadings. Two bonded systems were studied: graphite/epoxy adherends bonded with EC 3445 and FM-300 adhesives. For each bonded system, two specimen types were tested: a double-cantilever-beam specimen for mode 1 loading and a cracked-lapshear specimen for mixed-mode 1 and 2 loading. In all specimens tested, failure occurred in the form of debond growth. Debonding always occurred in a cohesive manner with EC 3445 adhesive. The FM-300 adhesive debonded in a cohesive manner under mixed-mode 1 and 2 loading, but in a cohesive, adhesive, or combined cohesive and adhesive manner under mode 1 loading. Total strain-energy release rate appeared to be the driving parameter for debond growth under static and fatigue loadings.

Mall, S.↗

Characterization of mode I and mixed-mode failure of adhesive bonds between composite adherends

A combined experimental and analytical investigation of an adhesively bonded composite joint was conducted to characterize both the static and fatigue beyond growth mechanism under mode 1 and mixed-mode 1 and 2 loadings. Two bonded systems were studied: graphite/epoxy adherends bonded with EC 3445 and FM-300 adhesives. For each bonded system, two specimen types were tested: a double-cantilever-beam specimen for mode 1 loading and a cracked-lapshear specimen for mixed-mode 1 and 2 loading. In all specimens tested, failure occurred in the form of debond growth. Debonding always occurred in a cohesive manner with EC 3445 adhesive. The FM-300 adhesive debonded in a cohesive manner under mixed-mode 1 and 2 loading, but in a cohesive, adhesive, or combined cohesive and adhesive manner under mode 1 loading. Total strain-energy release rate appeared to be the driving parameter for debond growth under static and fatigue loadings.

Mall, S.↗

Ice Formation in Gas-Diffusion Layers

Under sub-freezing conditions, ice forms in the gas-diffusion layer (GDL) of a proton exchange membrane fuel cell (PEMFC) drastically reducing cell performance. Although a number of strategies exist to prevent ice formation, there is little fundamental understanding of the mechanisms of freezing within PEMFC components. Differential scanning calorimetry (DSC) is used to elucidate the effects of hydrophobicity (Teflon® loading) and water saturation on the rate of ice formation within three commercial GDLs. We find that as the Teflon® loading increases, the crystallization temperature decreases due to a change in internal ice/substrate contact angle, as well as the attainable level of water saturation. Classical nucleation theory predicts the correct trend in freezing temperature with Teflon® loading.

30 DIRECT ENERGY CONVERSION↗

Pharmacokinetics, Safety, and Efficacy of Chemoembolization with Doxorubicin-Loaded Tightly Calibrated Small Microspheres in Patients with Hepatocellular Carcinoma

PurposeThis study examines safety, efficacy, and pharmacokinetics of chemoembolization with loadable microspheres ≤100 μm for hepatocellular carcinoma.Materials and MethodsA pilot safety study was performed in 19 patients with size and dose escalation and then 52 patients were enrolled prospectively and randomly assigned to chemoembolization with TANDEM™ loaded with 150 or 100 mg of doxorubicin.ResultsThe mean diameter of the tumors was 7.28 ± 2.09 cm (range 4–12) and distribution dominant/multiple 51.9/48.1 %. Child A/B distribution was 32/20 (61.5/38.5 %) and etiology HBV/HCV/HBV/HCV-hemochromatosis was 61.6/9.6/9.6/15.4 %. Twenty-five patients were assigned in the low and 27 in the high loading group. There was 1.92 % thirty-day mortality due to lesion rupture. Biliary damage was seen in 3 patients (5.7 %) in the high loading. Mean maximum plasma concentration of doxorubicin C{sub max} ± SD was 284.9 ± 276.2 ng/mL for the high and 108.5 ± 77.6 ng/mL for the low loading (p < 0.001). According to m-RECIST overall objective response after two sessions reached 61.22 and 63.82 % at 6 months. Notably, complete target lesion response (CR) after the second session was observed in 28.57 % and maintained in 23.40 % at 6 months. No statistical differences in the local response rates were observed between the two loading groups. Overall survival (OS) at 6 months, 1 , 2, and 3 years was 98.08, 92.3, 88.46, and 82.6 %, respectively. OS and Progression-Free Survival did not demonstrate statistical significance between the two loading groups.ConclusionInitial evidence shows that (a) TANDEM™ achieves high rates of local response and mid-term survival, (b) high loading provides no clinical benefit and is associated with biliary toxicity.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Seasonal Modulation of Crustal Seismicity in Northeastern Japan Driven by Snow Load

Numerous studies have reported that surface hydrological loading can seasonally modulate seismicity rates at crustal depths. For example, substantial winter snow accumulation occurs across the Japanese Islands, and these snowy regions appear to have seasonally modulated the occurrence of previous large inland earthquakes. Therefore, it is important to investigate the impact of seasonal stress changes on crustal seismicity to deepen our understanding of earthquake generation. Here we constrain seasonal changes in the surface load across northeastern Japan using Global Navigation Satellite System surface displacements and evaluate the potential relationship between temporal trends in inland seismicity and estimated seasonal stress changes. The spatial distribution of the seasonal surface load is consistent with snow depth along the Sea of Japan. The inland seismicity beneath northeastern Japan is modestly modulated by the seasonal stress changes that are induced by the annual snow load. However, this seasonal response is weaker than that in other regions. This weak modulation may be due to the small surface-load-induced stress perturbation relative to the long-term-averaged stressing rate and/or the limited presence of crustal fluids to trigger seismicity in Japan.

58 GEOSCIENCES↗

Grain size dependence of dynamic mechanical behavior of AZ31B magnesium alloy sheet under compressive shock loading

The effects of grain size on the dynamic deformation behavior of rolled AZ31B alloy at high strain rates were investigated. Rolled AZ31B alloy samples with grain sizes of 6, 18 and 37 μm, were subjected to shock loading tests using Split Hopkinson Pressure Bar at room temperature and at a strain rate of 1100 s{sup −} {sup 1}. It was found that a double-peak basal texture formed in the shock loaded samples. The strength and ductility of the alloy under the high strain-rate compressive loading increased with decreasing grain size. However, twinning fraction and strain hardening rate were found to decrease with decreasing grain size. In addition, orientation imaging microscopy showed a higher contribution of double and contraction twins in the deformation process of the coarse-grained samples. Using transmission electron microscopy, pyramidal dislocations were detected in the shock loaded sample, proving the activation of pyramidal slip system under dynamic impact loading. - Highlights: • A double-peak basal texture developed in all shock loaded samples. • Both strength and ductility increased with decreasing grain size. • Twinning fraction and strain hardening rate decreased with decreasing grain size. • ‘g.b’ analysis confirmed the presence of dislocations in shock loaded alloy.

36 MATERIALS SCIENCE↗

Strain energy release rate analysis of delamination in a tapered laminate subjected to tension load

A tapered composite laminate subjected to tension load was analyzed using the finite-element method. The glass/epoxy laminate has a (+ or - 45)sub 3 group of plies dropped in three distinct steps, each 20 ply-thicknesses apart, thus forming a taper angle of 5.71 degrees. Steep gradients of interlaminar normal and shear stress on a potential delamination interface suggest the existence of stress singularities at the points of material and geometric discontinuities created by the internal plydrops. The delamination was assumed to initiate at the thin end of the taper on a -45/+45 interface and the delamination growth was simulated in both directions, i.e., along the taper and into the thin region. The strain-energy-release rate for a delamination growing into the thin laminate consisted predominantly of mode I (opening) component. For a delamination growing along the tapered region, the strain-energy-release rate was initially all mode I, but the proportion of mode I decreased with increase in delamination size until eventually total G was all mode II. The total G for both delamination tips increased with increase in delamination size, indicating that a delamination initiating at the end of the taper will grow unstably along the taper and into the thin laminate simultaneously.

Salpekar, S. A.↗

Fatigue retardation due to creep in a fibrous composite

Experiments performed to determine the effects of temperature and creep strain on the fatigue life of a graphite/epoxy composite laminate show that (1) sustained periods of static loading have significant retardation effects on the fatigue degradation rate of the laminated composite, and (2) cyclic loading with a lower frequency preceding higher frequency loading also prolongs the fatigue life. A creep crack hypothesis is proposed that can provide reasonable interpretations for these experimental results.

Sun, C. T.↗

Fast Acting Eddy Current Driven Valve for Massive Gas Injection on ITER

Tokamak plasma disruptions present a significant challenge to ITER as they can result in intense heat flux, large forces from halo and eddy currents, and potential first-wall damage from the generation of multi-MeV runaway electrons. Massive gas injection (MGI) of high Z material using fast acting valves is being explored on existing tokamaks and is planned for ITER as a method to evenly distribute the thermal load of the plasma to prevent melting, control the rate of the current decay to minimize mechanical loads, and to suppress the generation of runaway electrons. A fast acting valve and accompanying power supply have been designed and first test articles produced to meet the requirements for a disruption mitigation system on ITER. The test valve incorporates a flyer plate actuator similar to designs deployed on TEXTOR, ASDEX upgrade, and JET [1 3] of a size useful for ITER with special considerations to mitigate the high mechanical forces developed during actuation due to high background magnetic fields. The valve includes a tip design and all-metal valve stem sealing for compatibility with tritium and high neutron and gamma fluxes.

Fast Acting Eddy current↗

Evolution of the Rate-Limiting step: From Thin Film to Thick Ni-rich Cathodes

Ni-rich NMC (LiNixMnyCo1-x-yO2, x = 0.6) has the attributes of high specific capacity (greater than 180 mAh g-1), high operating voltage (ca. 3.8 V) and low cost, which is therefore deemed as one of the most promising cathode candidates for next-generation high-energy Li-ion batteries (LIBs). However, challenges exist before the large-scale commercialization of Ni-rich cathode such as gas generation, capacity degradation especially at high rate or elevated temperatures. From thin film to densely pack high loading cathode, this work investigates the rate-limiting steps in Ni-rich cathodes e.g., phase structure, electronic and ionic conductivity to understand the reaction kinetics at different scales. This work provides new insights in understanding the electrochemical properties of Ni-rich cathode at different levels to inspire revolutionary ideas to address the fundamental issues of Ni-rich cathode from materials to relevant electrode levels.

Hu, Jiangtao↗

Small Business Demand Response with Communicating Thermostats: SMUD's Summer Solutions Research Pilot

This report documents a field study of 78 small commercial customers in the Sacramento Municipal Utility District service territory who volunteered for an integrated energy-efficiency/demand-response (EE-DR) program in the summer of 2008. The original objective for the pilot was to provide a better understanding of demand response issues in the small commercial sector. Early findings justified a focus on offering small businesses (1) help with the energy efficiency of their buildings in exchange for occasional load shed, and (2) a portfolio of options to meet the needs of a diverse customer sector. To meet these expressed needs, the research pilot provided on-site energy efficiency advice and offered participants several program options, including the choice of either a dynamic rate or monthly payment for air-conditioning setpoint control. An analysis of hourly load data indicates that the offices and retail stores in our sample provided significant demand response, while the restaurants did not. Thermostat data provides further evidence that restaurants attempted to precool and reduce AC service during event hours, but were unable to because their air-conditioning units were undersized. On a 100 F reference day, load impacts of all participants during events averaged 14%, while load impacts of office and retail buildings (excluding restaurants) reached 20%. Overall, pilot participants including restaurants had 2007-2008 summer energy savings of 20% and bill savings of 30%. About 80% of participants said that the program met or surpassed their expectations, and three-quarters said they would probably or definitely participate again without the $120 participation incentive. These results provide evidence that energy efficiency programs, dynamic rates and load control programs can be used concurrently and effectively in the small business sector, and that communicating thermostats are a reliable tool for providing air-conditioning load shed and enhancing the ability of customers on dynamic rates to respond to intermittent price events.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Fatigue flaw growth behavior in stiffened and unstiffened panels loaded in biaxial tension

The effect was investigated of biaxial loading on the flaw growth rate of 2219-T87 aluminum alloy that would be typical of Space Shuttle cryogenic tankage design. The stress distribution and stress concentration factors for several integrally stiffened panels under various loading conditions were obtained. The flaw growth behavior of both stiffened and unstiffened panels under biaxial loading conditions was determined. The effect of a complex stress state was studied by introducing flaws in fillet areas of biaxially loaded stiffened panels.

Beck, E. J.↗

BENCHMARK EVALUATION OF THE START-UP CORE REACTOR PHYSICS MEASUREMENTS OF THE HIGH TEMPERATURE ENGINEERING TEST REACTOR

The benchmark evaluation of the start-up core reactor physics measurements performed with Japan’s High Temperature Engineering Test Reactor, in support of the Next Generation Nuclear Plant Project and Very High Temperature Reactor Program activities at the Idaho National Laboratory, has been completed. The evaluation was performed using MCNP5 with ENDF/B-VII.0 nuclear data libraries and according to guidelines provided for inclusion in the International Reactor Physics Experiment Evaluation Project Handbook. Results provided include updated evaluation of the initial six critical core configurations (five annular and one fully-loaded). The calculated keff eigenvalues agree within 1s of the benchmark values. Reactor physics measurements that were evaluated include reactivity effects measurements such as excess reactivity during the core loading process and shutdown margins for the fully-loaded core, four isothermal temperature reactivity coefficient measurements for the fully-loaded core, and axial reaction rate measurements in the instrumentation columns of three core configurations. The calculated values agree well with the benchmark experiment measurements. Fully subcritical and warm critical configurations of the fully-loaded core were also assessed. The calculated keff eigenvalues for these two configurations also agree within 1s of the benchmark values. The reactor physics measurement data can be used in the validation and design development of future High Temperature Gas-cooled Reactor systems.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Rate-sensitive and self-releasing battery cells and battery-cell structures as structural and/or energy-absorbing vehicle components

A battery system includes a load bearing structure having battery cells, or structures formed by battery cells, and at least one mechanical switch, and an electrical connection coupled with the battery cells of the load bearing structure. A battery has a rate-sensitive component that is configured to deform into a first state to provide a first reaction force under a mechanical loading of a first magnitude. The rate-sensitive component is configured to deform into a second state to provide a second reaction force under a mechanical loading of a second magnitude.

25 ENERGY STORAGE↗

Load Expansion of Stoichiometric HCCI Using Spark Assist and Hydraulic Valve Actuation

A spark-assist homogeneous charge compression ignition (SA-HCCI) operating strategy is presented here that allows for stoichiometric combustion from 1000-3000 rpm, and at loads as high as 750 kPa net IMEP. A single cylinder gasoline engine equipped with direct fuel injection and fully variable hydraulic valve actuation (HVA) is used for this experimental study. The HVA system enables negative valve overlap (NVO) valve timing for hot internal EGR. Spark-assist stabilizes combustion over a wide range of engine speeds and loads, and allows for stoichiometric operation at all conditions. Characteristics of both spark-ignited combustion and HCCI are present, with combustion analysis showing a distinctive spark ignited phase of combustion, followed by a much more rapid HCCI combustion phase. At high load, the maximum pressure rise rate is controlled by a combination of spark timing and retarding the intake valve closing angle. The latter reduces the effective compression ratio, and therefore the compressive temperatures, allowing the high load limit of the operating range to be expanded. The SA-HCCI operating strategy exhibits improved thermal efficiency at most operating conditions, with fuel consumption improvements up to 9% realized at light engine loads. The SA-HCCI operating strategy presented here does not provide an efficiency advantage at all operating points compared to SI combustion; a decrease was observed at the highest speed and at loads above 500 kPa net IMEP. At light engine loads the majority of the heat release takes place during the HCCI phase of the heat release, and as such the NOx emissions are very low and are similar to levels observed in pure HCCI. At higher loads, a larger portion of the heat release takes place during the spark ignited phase of combustion, which produces NOx emissions that are much higher than is typically associated with HCCI, but still represent a decrease from conventional SI combustion. By limiting the fuel/air mixture to stoichiometric conditions, the higher NOx emissions do not represent an implementation barrier to this strategy because compatibility is maintained with very effective conventional 3-way catalysts.