Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Image Segmentation”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,153 records · Page 64

Outer Wall Segmentation of Abdominal Aortic Aneurysm by Variable Neighborhood Search Through Intensity and Gradient Spaces

Aortic aneurysm segmentation remains a challenge. Manual segmentation is a time-consuming process which is not practical for routine use. To address this limitation, several automated segmentation techniques for aortic aneurysm have been developed, such as edge detection-based methods, partial differential equation methods, and graph partitioning methods. However, automatic segmentation of aortic aneurysm is difficult due to high pixel similarity to adjacent tissue and a lack of color information in the medical image, preventing previous work from being applicable to difficult cases. This paper uses uses a variable neighborhood search that alternates between intensity-based and gradient-based segmentation techniques. By alternating between intensity and gradient spaces, the search can escape from local optima of each space. The experimental results demonstrate that the proposed method outperforms the other existing segmentation methods in the literature, based on measurements of dice similarity coefficient and jaccard similarity coefficient at the pixel level. In addition, it is shown to perform well for cases that are difficult to segment.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Stellar Population Properties in the Stellar Streams around SPRC047

Abstract We have investigated the properties (e.g., age, metallicity) of the stellar populations of a ringlike tidal stellar stream (or streams) around the edge-on galaxy SPRC047 (z= 0.031) using spectral energy distribution (SED) fits to integrated broadband aperture flux densities. We used visual images in six different bands and Spitzer/IRAC 3.6μm data. We have attempted to derive best-fit stellar population parameters (metallicity, age) in three noncontiguous segments of the stream. Due to the very low surface brightness of the stream, we have performed a deconvolution with a Richardson–Lucy–type algorithm of the low spatial resolution 3.6μm IRAC image, thereby reducing the effect of the point-spread function aliasedemissionfrom the bright edge-on central galaxy at the locations of our three stream segments. Our SED fits that used several different star formation (SF) history priors, from an exponentially decaying SF burst to continuous SF, indicate that the age–metallicity–dust degeneracy is not resolved, most likely because of inadequate wavelength coverage and low signal-to-noise ratios of the low surface brightness features. We also discuss how future deep visual–near-infrared observations, combined with absolute flux calibration uncertainties at or below the 1% level, complemented by equally well absolute flux-calibrated observations in ultraviolet and mid-infrared bands, would improve the accuracy of broadband SED fitting results for low surface brightness targets, such as stellar streams around nearby galaxies that are not resolved into stars.

Astronomy & Astrophysics↗

Origins of Feeding Arteries of Hepatocellular Carcinoma Located Near the Umbilical Fissure of the Left Hepatic Lobe: Angiographic Evaluation

Purpose: To analyze the origins of the feeding arteries of hepatocellular carcinomas (HCCs) near the umbilical fissure of the left hepatic lobe. Methods: Twenty-eight HCCs with a mean {+-} SD tumor diameter of 3.4 {+-} 1.0 cm (range 1-4.4 cm) in contact with the right or left side of the umbilical fissure were treated by superselective transcatheter arterial chemoembolization (TACE). The origins of the tumor-feeding arteries were analyzed with arteriograms and computed tomography or cone-beam computed tomography images obtained during and 1 week after TACE.ResultsTwenty-one HCC lesions were located in segment 3 and seven were located in segment 4. Of 21 tumors in segment 3, 13 (61.9%) were supplied by the lateral inferior subsegmental artery (A3), three (14.3%) by the medial subsegmental artery (A4), three (14.3%) by both A4 and A3, one (4.8%) by a branch arising from the left lateral hepatic artery, and one (4.8%) by a branch of the right gastric artery. In particular, all tumor-feeding branches arising from A4 were the first branch of A4. Of seven tumors in segment 4, four (57.1%) were supplied by A4 and three (42.9%) by A3. In particular, all tumor-feeding branches arising from A3 were the first branch of A3. Conclusion: This study demonstrates crossover blood supply to HCC lesions located near the umbilical fissure, in addition to direct feeding from a separate branch. In particular, the first branch of the opposite subsegmental artery may feed tumors when crossover blood supply is present.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Detection of Cement Leakage After Vertebroplasty with a Non-Flat-Panel Angio Unit Compared to Multidetector Computed Tomography - An Ex Vivo Study

The purpose of this study was to investigate the detection of cement leakages after vertebroplasty using angiographic computed tomography (ACT) in a non-flat-panel angio unit compared to multidetector computed tomography (MDCT). Vertebroplasty was performed in 19 of 33 cadaver vertebrae (23 thoracic and 10 lumbar segments). In the angio suite, ACT (190{sup o}; 1.5{sup o} per image) was performed to obtain volumetric data. Another volumetric data set of the specimen was obtained by MDCT using a standard algorithm. Nine multiplanar reconstructions in standardized axial, coronal, and sagittal planes of every vertebra were generated from both data sets. Images were evaluated on the basis of a nominal scale with 18 criteria, comprising osseous properties (e.g., integrity of the end plate) and cement distribution (e.g., presence of intraspinal cement). MDCT images were regarded as gold standard and analyzed by two readers in a consensus mode. Rotational acquisitions were analyzed by six blinded readers. Results were correlated with the gold standard using Cohen's {kappa}-coefficient analysis. Furthermore, interobserver variability was calculated. Correlation with the gold standard ranged from no correlation (osseous margins of the neuroforamen, {kappa} = 0.008) to intermediate (trace of vertebroplasty canula; {kappa} = 0.615) for criteria referring to osseous morphology. However, there was an excellent correlation for those criteria referring to cement distribution, with {kappa} values ranging from 0.948 (paravertebral cement distribution) to 0.972 (intraspinal cement distribution). With a minimum of {kappa} = 0.768 ('good correlation') and a maximum of {kappa} = 0.91 ('excellent'), interobserver variability was low. In conclusion, ACT in an angio suite without a flat-panel detector depicts a cement leakage after vertebroplasty as well as MDCT. However, the method does not provide sufficient depiction of osseous morphology.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

OptEase and TrapEase Vena Cava Filters: A Single-Center Experience in 258 Patients

We aimed to evaluate the efficacy and safety of the OptEase and TrapEase (both from Cordis, Roden, Netherlands) vena cava filters in the prevention of pulmonary embolism (PE). Between May 2004 and December 2008, OptEase (permanent/retrievable; n = 228) or TrapEase (permanent; n = 30) vena cava filters were placed in 258 patients (160 female and 98 male; mean age 62 years [range 22 to 97]). Indications were as follows: prophylaxis for PE (n = 239), contraindication for anticoagulation in the presence of PE or DVT (n = 10), and development of PE or DVT despite anticoagulation (n = 9). Medical records were retrospectively reviewed for indications, clinical results, and procedure-related complications during placement and retrieval. Clinical PE did not develop in any of the patients. However, radiologic signs of segmental PE were seen in 6 of 66 patients with follow-up imaging data. Migration or fracture of the filter or cava perforation was not seen in any of the patients. Except for a single case of asymptomatic total cava thrombosis, no thrombotic occlusion was observed. One hundred forty-one patients were scheduled to undergo filter removal; however, 17 of them were not suitable for such based on venography evaluation. Removal was attempted in 124 patients and was successful in 115 of these (mean duration of retention 11 days [range 4 to 23]). Nine filters could not be removed. Permanent/retrievable vena cava filters are safe and effective devices for PE prophylaxis and for the management of venous thromboembolism by providing the option to be left in place.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Spectral resolution measurement of an x-ray imaging crystal spectrometer for KSTAR

A spectral resolution measurement of the x-ray imaging crystal spectrometer for the Korea Superconducting Tokamak Advanced Research machine utilizing a segmented position-sensitive detector and time-to-digital converter based delay-line readout electronics was performed by using an x-ray tube in a laboratory. The measured spectral resolution is about 12 600, which means the actual energy resolution is 0.32 eV for the x-ray tube's bremsstrahlung peak energy of 4 keV. The results from the spectral resolution measurement are described.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Evolution of intermittent filaments in the scrape-off layer of NSTX

Filamentary structures naturally arise from background turbulence in the scrape-off layer (SOL) of plasmas, leading to significant particle and heat transport that can degrade overall plasma confinement. This enhanced transport can contribute to unacceptably high heat loads on plasma-facing components. As such, understanding the physics of SOL plasma filaments is critical for predicting and mitigating their effects in future fusion devices. On the National Spherical Torus Experiment (NSTX), plasma filaments—commonly referred to as “blobs”—were investigated using the gas-puff imaging (GPI) diagnostic in the edge and SOL regions. The analysis involved identifying, segmenting, and tracking the characteristic contours of the blobs in each frame of the GPI video sequences. Their evolution was characterized through shape descriptors, velocity, and angular velocity derived from their contour coordinates. The results indicate that as the blob area increases, their shapes become more concave and less circular, suggesting reduced structural stability in larger blobs. This result aligns with previous theoretical results where it was shown that larger blobs are more susceptible to instabilities [Krasheninnikov et al., J. Plasma Phys. 74, 679–717 (2008) and D'Ippolito et al., Phys. Plasmas 18, 060501 (2011)]. A positive correlation was observed between radial velocity and radial position, suggesting radially outward acceleration of the filaments, potentially driven by decreasing viscous drag toward the far SOL. Interestingly, blobs in background SOL turbulence exhibited minimal spinning in contrast to filaments originating from edge localized modes, which show substantial rotation during their paths [Lampert et al., Phys. Plasmas 29, 102502 (2022)]. Statistical analysis of the solidity and total curvature shape descriptors, along with their temporal evolution, revealed relatively broad, near-Gaussian distributions. This suggests that blob morphology is strongly influenced by stochastic turbulent processes in the surrounding plasma environment. Blob parameters were also compared with bulk plasma and radial profile measurements. Notable trends were found between blob rotation and poloidal velocity with collisionality and line-integrated density. These findings contribute to a deeper understanding of blob dynamics and provide valuable insights for refining SOL turbulence models.

Covariance and correlation↗

Particle trajectory representation learning with masked point modeling

Liquid argon time projection chambers (LArTPCs) offer millimeter-scale 3D images of particle trajectories, enabling precision studies of neutrino oscillation, detection of supernova and solar neutrinos, searches for exotic dark matter, and proton decay. Current approaches utilize supervised machine learning models, requiring extensive simulations of particle physics and detector response that can introduce bias. Self-supervised learning (SSL), a machine learning approach that learns useful representations of unlabeled data from the data itself, has significantly advanced how large datasets are utilized for representation learning; however, its potential for applications to sensory data in high precision particle physics experiments remains largely unexplored. We introduce the Point-based liquid argon masked autoencoder (PoLAr-MAE), a self-supervised framework that learns physically meaningful representations directly from unlabeled LArTPC images. PoLAr-MAE achieves remarkable data efficiency for a point-level segmentation task, outperforming fully supervised methods in low data regimes. Linear classifiers on model outputs demonstrate robust performance across multiple downstream tasks. Our results position sensor-level SSL as a practical foundation model strategy for LArTPCs.

Young, Samuel [Stanford Univ., CA (United States)]↗

Proximal femur segmentation in conventional pelvic x ray

A solid and accurate proximal femur segmentation technique using the popular active shape model (ASM) is proposed. For generating an optimal shape prior, the minimum description length, based on 200 supervised manual segmented proximal femur shapes, is used. The segmentation is based on a coarse to fine scaling technique including a profile scale space method. The segmentation results are compared using an optimal defined initial pose and a pose based on a registration technique. Using ideal template initialization, 95% of the shapes have been recovered exactly (average point-to-point error {approx}13 pixels, average point-to-boundary error {approx}7 pixels). Using a template-based initialization based on a registration technique, a successful segmentation rate of {approx}89% is achieved, with an average point-to-point error {approx}12 pixels, and an average point-to-boundary error {approx}8 pixels. With an adequate template initialization and an improved ASM, this method seems to provide an accurate tool for segmentation of the proximal femur shapes on conventional hip overview x-ray images.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

ecospec v0.1.0

Bespoke software for segmenting plants in ecoFABs to monitor growth and health. Contains python libraries for image alignment, training neural networks and running inference.

Zwart, PetrusH [Lawrence Berkeley National Laborat↗

SE Great Basin Play Fairway Analysis Heat and Permeability CRS

Within this submission are multiple .tif images with accompanying metadata of magnetotelluric conductor occurrence, fault critical stress composite risk segment (CRS), permeability CRS, Quaternary mafic extrusions, Quaternary fault density, and Quaternary rhyolite maps. Each of these contributed to a final play fairway analysis (PFA) for the SE Great Basin study area.

15 GEOTHERMAL ENERGY↗

Analysis of irradiated U-7wt%Mo dispersion fuel microstructures using automated image processing

The High Performance Research Reactor Fuel Development (HPPRFD) program is responsible for developing low enriched uranium (LEU) fuel substitutes for high performance reactors fueled with highly enriched uranium (HEU) that have not yet been converted to LEU. The uranium-molybdenum (U-Mo) fuel system was selected for this effort. In this study, fission gas pore segmentation was performed on U-7wt%Mo dispersion fuel samples at three separate fission densities using an automated image processing interface developed in MATLAB. Pore size distributions were attained that showed both expected and unexpected fission gas behavior. In general, it proved challenging to identify any dominant trends when comparing fission bubble data across samples from different fuel plates due to varying compositions and fabrication techniques. Here, the results exhibited fair agreement with the fission density vs. porosity correlation developed by the Russian reactor conversion program.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

The simulation of 3D mass models in 2D digital mammography and breast tomosynthesis

Purpose: This work proposes a new method of building 3D breast mass models with different morphological shapes and describes the validation of the realism of their appearance after simulation into 2D digital mammograms and breast tomosynthesis images. Methods: Twenty-five contrast enhanced MRI breast lesions were collected and each mass was manually segmented in the three orthogonal views: sagittal, coronal, and transversal. The segmented models were combined, resampled to have isotropic voxel sizes, triangularly meshed, and scaled to different sizes. These masses were referred to as nonspiculated masses and were then used as nuclei onto which spicules were grown with an iterative branching algorithm forming a total of 30 spiculated masses. These 55 mass models were projected into 2D projection images to obtain mammograms after image processing and into tomographic sequences of projection images, which were then reconstructed to form 3D tomosynthesis datasets. The realism of the appearance of these mass models was assessed by five radiologists via receiver operating characteristic (ROC) analysis when compared to 54 real masses. All lesions were also given a breast imaging reporting and data system (BIRADS) score. The data sets of 2D mammography and tomosynthesis were read separately. The Kendall's coefficient of concordance was used for the interrater observer agreement assessment for the BIRADS scores per modality. Further paired analysis, using the Wilcoxon signed rank test, of the BIRADS assessment between 2D and tomosynthesis was separately performed for the real masses and for the simulated masses. Results: The area under the ROC curves, averaged over all observers, was 0.54 (95% confidence interval [0.50, 0.66]) for the 2D study, and 0.67 (95% confidence interval [0.55, 0.79]) for the tomosynthesis study. According to the BIRADS scores, the nonspiculated and the spiculated masses varied in their degrees of malignancy from normal (BIRADS 1) to highly suggestive for malignancy (BIRADS 5) indicating the required variety of shapes and margins of these models. The assessment of the BIRADS scores for all observers indicated good agreement based on Kendall's coefficient for both the 2D and the tomosynthesis evaluations. The paired analysis of the BIRADS scores between 2D and tomosynthesis for each observer revealed consistent behavior for the real and simulated masses. Conclusions: A database of 3D mass models, with variety of shapes and margins, was validated for the realism of their appearance for 2D digital mammography and for breast tomosynthesis. This database is suitable for use in future observer performance studies whether in virtual clinical trials or in patient images with simulated lesions.

60 APPLIED LIFE SCIENCES↗

Digital Tomosynthesis for Respiratory Gated Liver Treatment: Clinical Feasibility for Daily Image Guidance

Purpose: Breath-hold (BH) treatment minimizes internal target volumes (ITV) when treating sites prone to motion. Digital tomosynthesis (DTS) imaging has advantages over cone-beam CT (CBCT) for BH imaging: BH-DTS scan can be completed during a single breath-hold, whereas BH-CBCT is usually acquired by parsing the gantry rotation into multiple BH segments. This study evaluates the localization accuracy of DTS for BH treatment of liver tumors. Methods: Both planning CT and on-board DTS/CBCT images were acquired under BH, using the planning CT BH window as reference. Onboard imaging data sets included two independent DTS orientations (coronal and sagittal), and CBCT images. Soft tissue target positioning was measured by each imaging modality and translated into couch shifts. Performance of the two DTS orientations was evaluated by comparing target positioning with the CBCT benchmark, determined by two observers. Results: Image data sets were collected from thirty-eight treatment fractions (14 patients). Mean differences between the two DTS methods and the CBCT method were <1 mm in all directions (except the lateral direction with sagittal-DTS: 1.2 mm); the standard deviation was in the range of 2.1-3.5 mm for all techniques. The Pearson correlation showed good interobserver agreement for the coronal-DTS (0.72-0.78). The interobserver agreement for the sagittal-DTS was good for the in-plane directions (0.70-0.82), but poor in the out-of-plane direction (lateral, 0.26). Conclusions: BH-DTS may be a simpler alternative to BH-CBCT for onboard soft tissue localization of the liver, although the precision of DTS localization appears to be somewhat lower because of the presence of subtle out-of-plane blur.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

SU-D-207A-04: Use of Gradient Echo Plural Contrast Imaging (GEPCI) in MR-Guided Radiation Therapy: A Feasibility Study Targeting Brain Treatment

Purpose: To implement the Gradient Echo Plural Contrast Imaging(GEPCI) technique in MRI-simulation for radiation therapy and assess the feasibility of using GEPCI images with advanced inhomogeneity correction in MRI-guided radiotherapy for brain treatment. Methods: An optimized multigradient-echo GRE sequence (TR=50ms;TE1=4ms;delta-TE=4ms;flip angle=300,11 Echoes) was developed to generate both structural (T1w and T2*w) and functional MRIs (field and susceptibility maps) from a single acquisition. One healthy subject (Subject1) and one post-surgical brain cancer patient (Subject2) were scanned on a Philips Ingenia 1.5T MRI used for radiation therapy simulation. Another healthy subject (Subject3) was scanned on a 0.35T MRI-guided radiotherapy (MR-IGRT) system (ViewRay). A voxel spread function (VSF) was used to correct the B0 inhomogeneities caused by surgical cavities and edema for Subject2. GEPCI images and standard radiotherapy planning MRIs for this patient were compared focusing the delineation of radiotherapy target region. Results: GEPCI brain images were successfully derived from all three subjects with scan times of <7 minutes. The images derived for Subjects1&2 demonstrated that GEPCI can be applied and combined into radiotherapy MRI simulation. Despite low field, T1-weighted and R2* images were successfully reconstructed for Subject3 and were satisfactory for contour and target delineation. The R2* distribution of grey matter (center=12,FWHM=4.5) and white matter (center=14.6, FWHM=2) demonstrated the feasibility for tissue segmentation and quantification. The voxel spread function(VSF) corrected surgical site related inhomogeneities for Subject2. R2* and quantitative susceptibility map(QSM) images for Subject2 can be used to quantitatively assess the brain structure response to radiation over the treatment course. Conclusion: We implemented the GEPCI technique in MRI-simulation and in MR-IGRT system for radiation therapy. The images demonstrated that it is feasible to adopt this technique in radiotherapy for structural delineation. The preliminary data also enable the opportunity for quantitative assessment of radiation response of the target region and normal tissue.

60 APPLIED LIFE SCIENCES↗

AUTOMATIC RETINA EXUDATES SEGMENTATION WITHOUT A MANUALLY LABELLED TRAINING SET

Diabetic macular edema (DME) is a common vision threatening complication of diabetic retinopathy which can be assessed by detecting exudates (a type of bright lesion) in fundus images. In this work, two new methods for the detection of exudates are presented which do not use a supervised learning step and therefore do not require ground-truthed lesion training sets which are time consuming to create, difficult to obtain, and prone to human error. We introduce a new dataset of fundus images from various ethnic groups and levels of DME which we have made publicly available. We evaluate our algorithm with this dataset and compare our results with two recent exudate segmentation algorithms. In all of our tests, our algorithms perform better or comparable with an order of magnitude reduction in computational time.

59 BASIC BIOLOGICAL SCIENCES↗