Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Image Segmentation”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,153 records · Page 64

Improving OFDR Distributed Fiber Sensing by Fibers With Enhanced Rayleigh Backscattering and Image Processing

This article investigates using optical fibers with enhanced backscattering profiles to improve distributed fiber sensor performance and reduce instrumentation costs. Using a femtosecond (fs) laser direct writing technique, the Rayleigh backscattering profile of a standard telecom fiber was enhanced by more than 40 dB to improve the signal-to-noise ratio (SNR) for optical frequency domain reflectometry (OFDR). The enhanced backscattering signals enable effectively distributed strain measurements using a low-cost tunable laser (TL). Median filtering is applied to denoise cross correlation results to further improve measurement outcomes. Results presented in this article show that a TL with a 1-nm tuning range, which is far less than the tuning range used in commercial OFDR interrogators, can perform effectively distributed strain measurements using sensing fibers with enhanced backscattering profiles. The sensing fiber with over 40-dB backscattering enhancement achieved 4.8-cm spatial resolution in strain measurements with a root mean square accuracy of less than 2.70 με when 10–50 με were exerted to the sensing fiber. In conclusion, results presented in this article reveal both the potential and limitations of sensing fibers with enhanced backscattering for OFDR-based distributed fiber sensors.

42 ENGINEERING↗

Evaluation of a method for activity estimation in Sm-153 EDTMP imaging

Absolute activity evaluation is fundamental for internal radionuclide dosimetry when patient-specific therapy optimization is wanted. Often, quantification is attempted with 3D SPECT image based (IB) methods, but the true concentration values can be underestimated due to the partial volume effect (PVE). This is especially true when small diffuse lesions are present. In this paper, we describe a 3D region of interest (ROI) based quantification method (LS-ROI), which estimates the ROI concentration values directly from the projection data acquired in the tomographic scan once ROIs have been segmented on a CT and/or a SPECT image. The method, which has inherent PVE correction capabilities, was applied both on simulated and on real phantom data. Simulations reflected the case of a patient with bone metastases treated with {sup 153}Sm-EDTMP: Both the activity in the metastases and the total retention in the skeleton were evaluated. Thirty noisy data sets were produced in order to evaluate the accuracy and precision of the method. The effect of region segmentation errors on estimated concentrations was thoroughly investigated. Real data were acquired on a NEMA phantom, where a cylindrical central region (283 cm{sup 3}) simulated the bone and two spheres (10.3 and 25.5 cm{sup 3}) simulated the metastases. The results obtained with the LS-ROI method were compared with those of a conventional 3D IB method and those of a quantitative conjugate view approach derived from LS-ROI and applied to the anterior and posterior views acquired in the tomographic scan (LS-ROI anterior-posterior: LS-ROI-AP). Simulations showed that when the geometry of regions is known, the LS-ROI method recovered the simulated concentration values within 20%, while the IB method underestimated the concentration in high activity small lesions by as much as 49%. Segmentation errors, up to 44% of the true region volume, produced a higher variation in LS-ROI estimates than in IB ones; however, the overall bias of the LS-ROI estimates ({<=}25%) remained lower than that of IB estimates. In the case of the evaluation of the total retention in the skeleton, the LS-ROI method recovered the simulated value within 2%, while IB underestimated it up to 13%. In all the cases, the LS-ROI-AP method showed an accuracy comparable with that of the LS-ROI one, and a worse precision just because of the lower number of counts used in the analysis. However, a worsening of LS-ROI-AP performances was demonstrated in the case of strong overlap of regions: In this case, a bias of up to 40% was observed. The results obtained on real phantom data confirmed the simulation results: The IB method underestimated activity up to 47% in the smallest sphere, while the bias was reduced to 13% with LS-ROI and LS-ROI-AP estimates. The good quantification capabilities of the LS-ROI method can be useful for absolute activity quantification in the case of small active diffused lesions and constitute the basis for the development of an accurate patient-specific planning strategy in internal radionuclide treatments, provided there is a reliable segmentation of lesions.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Low Cerebral Blood Volume Identifies Poor Outcome in Stent Retriever Thrombectomy

BackgroundMechanical thrombectomy (MT) is an efficient treatment of acute stroke caused by large-vessel occlusion. We evaluated the factors predicting poor clinical outcome (3-month modified Rankin Scale, mRS >2) although MT performed with modern stent retrievers.MethodsWe prospectively collected the clinical and imaging data of 105 consecutive anterior circulation stroke patients who underwent MT after multimodal CT imaging. Patients with occlusion of the internal carotid artery and/or middle cerebral artery up to the M2 segment were included. We recorded baseline clinical, procedural and imaging variables, technical outcome, 24-h imaging outcome and the clinical outcome. Differences between the groups were studied with appropriate statistical tests and binary logistic regression analysis.ResultsLow cerebral blood volume Alberta stroke program early CT score (CBV-ASPECTS) was associated with poor clinical outcome (median 7 vs. 9, p = 0.01). Lower collateral score (CS) significantly predicted poor outcome in regression modelling with CS = 0 increasing the odds of poor outcome 4.4-fold compared to CS = 3 (95% CI 1.27–15.5, p = 0.02). Lower CBV-ASPECTS significantly predicted poor clinical outcome among those with moderate or severe stroke (OR 0.82, 95% CI 0.68–1, p = 0.05) or poor collateral circulation (CS 0–1, OR 0.66, 95% CI 0.48–0.90, p = 0.009) but not among those with mild strokes or good collaterals.ConclusionsCBV-ASPECTS estimating infarct core is a significant predictor of poor clinical outcome among anterior circulation stroke patients treated with MT, especially in the setting of poor collateral circulation and/or moderate or severe stroke.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Unsupervised Azimuth Estimation of Solar Arrays in Low-Resolution Satellite Imagery through Semantic Segmentation and Hough Transform

This paper explains the use of a convolutional neural network (CNN) to segment solar panels in a satellite image containing solar arrays, and extract associated metadata from the arrays. A novel unsupervised technique is introduced to estimate the azimuth of each individual solar panel from the predicted mask of the convolutional neural network. This pipeline was developed with the aim of extracting necessary metadata for a solar installation, using only a set of latitude–longitude coordinates. Azimuth prediction results for 669 individual solar installations associated with 387 sites located across the United States are provided. A mean average error and median average error of 21.65 degrees and 1.0 degrees were obtained, respectively, when predicting the azimuth of the solar fleet data set, with about 80% of the results within an error of zero degrees of the ground truth azimuth value and about 85% within an error of 25 degrees. The predicted azimuth was then used to estimate the energy conversion of the solar arrays. Results show a 90.9 and 90.6 R-squared value for estimating alternating current (AC) and direct current (DC) energy, respectively, and a mean absolute percentage error (MAPE) of 1.70% in estimating the alternating current (AC) energy using the fully automated algorithm.

14 SOLAR ENERGY↗

Detecting brain tumor in computed tomography images using Markov random fields and fuzzy C-means clustering techniques

Brain tumors, are an abnormal growth of tissues in the brain. They may arise in people of any age. They must be detected early, diagnosed accurately, monitored carefully, and treated effectively in order to optimize patient outcomes regarding both survival and quality of life. Manual segmentation of brain tumors from CT scan images is a challenging and time consuming task. Size and location accurate detection of brain tumor plays a vital role in the successful diagnosis and treatment of tumors. Brain tumor detection is considered a challenging mission in medical image processing. The aim of this paper is to introduce a scheme for tumor detection in CT scan images using two different techniques Hidden Markov Random Fields (HMRF) and Fuzzy C-means (FCM). The proposed method has been developed in this research in order to construct hybrid method between (HMRF) and threshold. These methods have been applied on 4 different patient data sets. The result of comparison among these methods shows that the proposed method gives good results for brain tissue detection, and is more robust and effective compared with (FCM) techniques.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Deep medical image analysis with representation learning and neuromorphic computing

Deep learning is increasingly used in medical imaging, improving many steps of the processing chain, from acquisition to segmentation and anomaly detection to outcome prediction. Yet significant challenges remain: (i) image-based diagnosis depends on the spatial relationships between local patterns, something convolution and pooling often do not capture adequately; (ii) data augmentation, the de facto method for learning three-dimensional pose invariance, requires exponentially many points to achieve robust improvement; (iii) labelled medical images are much less abundant than unlabelled ones, especially for heterogeneous pathological cases; and (iv) scanning technologies such as magnetic resonance imaging can be slow and costly, generally without online learning abilities to focus on regions of clinical interest. To address these challenges, novel algorithmic and hardware approaches are needed for deep learning to reach its full potential in medical imaging.

60 APPLIED LIFE SCIENCES↗

An Application of Faster R-CNNs in Object Detection Efforts Applied to the Critical Infrastructure Domain

Object detection and segmentation approaches have been successfully applied to multiple interdisciplinary domains ranging from medical imaging to autonomous vehicles. The following study details efforts to apply segmentation methods to the critical infrastructure domain. Specifically, the identification of critical sub-components of four facilities: airports, hospitals, hydroelectric dams, and water treatment plants. Data for this study was extracted from the U.S. Department of Agriculture’s National Agriculture Imagery Program data set. Each facility class was considered independently of the other facilities, producing four different segmentation models during the testing and training process. Ultimately, the study team concluded there are significant challenges associated with object detection modeling when applied to facility analysis within the critical infrastructure domain. The study team was able to identify possible sources of these challenges that could be potentially addressed in future work.

97 MATHEMATICS AND COMPUTING↗

2D Rotational Angiography for Fast and Standardized Evaluation of Peripheral and Visceral Artery Stenoses

Purpose: To investigate the value of rotational digital subtraction angiography (rDSA) for evaluation of peripheral and visceral artery stenoses compared to conventional digital subtraction angiography (cDSA). Methods: A phantom study was performed comparing the radiation dose of cDSA with two projections and rDSA by means of the 2D Dynavision technique (Siemens Medical Solutions, Forchheim, Germany). Subsequently, 33 consecutive patients (18 women, 15 men; mean {+-} SD age 67 {+-} 15 years) were examined by both techniques. In total, 63 vessel segments were analyzed by two observers with respect to stenoses, image contrast, and vessel sharpness. Results: Radiation dose was significantly lower with rDSA. cDSA and rDSA revealed 21 and 24 flow-relevant stenotic lesions and vessel occlusions (70-100%), respectively. The same stenosis grade was assessed in 45 segments. By means of rDSA, 10 lesions were judged to have a higher and 8 lesions a lower stenosis grade compared to cDSA. rDSA yielded additive information regarding the vessel anatomy and pathology in 29 segments. However, a tendency toward better image quality and sharper vessel visualization was seen with cDSA. Conclusion: rDSA allows for multiprojection assessment of peripheral and visceral arteries and provides additional clinically relevant information after a single bolus of contrast medium. At the same time, radiation dose can be significantly reduced compared to cDSA.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Three-Dimensional Imaging and Numerical Reconstruction of Graphite/Epoxy Composite Microstructure Based on Ultra-High Resolution X-Ray Computed Tomography

A combined experimental and computational study aimed at high-resolution 3D imaging, visualization, and numerical reconstruction of fiber-reinforced polymer microstructures at the fiber length scale is presented. To this end, a sample of graphite/epoxy composite was imaged at sub-micron resolution using a 3D X-ray computed tomography microscope. Next, a novel segmentation algorithm was developed, based on concepts adopted from computer vision and multi-target tracking, to detect and estimate, with high accuracy, the position of individual fibers in a volume of the imaged composite. In the current implementation, the segmentation algorithm was based on Global Nearest Neighbor data-association architecture, a Kalman filter estimator, and several novel algorithms for virtualfiber stitching, smoothing, and overlap removal. The segmentation algorithm was used on a sub-volume of the imaged composite, detecting 508 individual fibers. The segmentation data were qualitatively compared to the tomographic data, demonstrating high accuracy of the numerical reconstruction. Moreover, the data were used to quantify a) the relative distribution of individual-fiber cross sections within the imaged sub-volume, and b) the local fiber misorientation relative to the global fiber axis. Finally, the segmentation data were converted using commercially available finite element (FE) software to generate a detailed FE mesh of the composite volume. The methodology described herein demonstrates the feasibility of realizing an FE-based, virtual-testing framework for graphite/fiber composites at the constituent level.

Czabaj, M. W.↗

Irradiation of the prostate and pelvic lymph nodes with an adaptive algorithm

Purpose: The simultaneous treatment of pelvic lymph nodes and the prostate in radiotherapy for prostate cancer is complicated by the independent motion of these two target volumes. In this work, the authors study a method to adapt intensity modulated radiation therapy (IMRT) treatment plans so as to compensate for this motion by adaptively morphing the multileaf collimator apertures and adjusting the segment weights. Methods: The study used CT images, tumor volumes, and normal tissue contours from patients treated in our institution. An IMRT treatment plan was then created using direct aperture optimization to deliver 45 Gy to the pelvic lymph nodes and 50 Gy to the prostate and seminal vesicles. The prostate target volume was then shifted in either the anterior-posterior direction or in the superior-inferior direction. The treatment plan was adapted by adjusting the aperture shapes with or without re-optimizing the segment weighting. The dose to the target volumes was then determined for the adapted plan. Results: Without compensation for prostate motion, 1 cm shifts of the prostate resulted in an average decrease of 14% in D-95%. If the isocenter is simply shifted to match the prostate motion, the prostate receives the correct dose but the pelvic lymph nodes are underdosed by 14% {+-} 6%. The use of adaptive morphing (with or without segment weight optimization) reduces the average change in D-95% to less than 5% for both the pelvic lymph nodes and the prostate. Conclusions: Adaptive morphing with and without segment weight optimization can be used to compensate for the independent motion of the prostate and lymph nodes when combined with daily imaging or other methods to track the prostate motion. This method allows the delivery of the correct dose to both the prostate and lymph nodes with only small changes to the dose delivered to the target volumes.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Methods for rapid identification of anomalous layers in laser powder bed fusion

In situ process monitoring is a key requirement for increased industry acceptance of powder bed Additive Manufacturing. As sensing technologies increase in maturity, attention must also be given to effective data exploration techniques. These data are often high-resolution and multi-modal, with each build consisting of thousands of layers. Here, in this paper, the authors propose two methods enabling users to rapidly identify layers of interest within a build. Both methods leverage results from deep learning based segmentations of in situ powder bed images. The first method is an unsupervised “reverse layer search” algorithm while the second method uses supervised machine learning.

36 MATERIALS SCIENCE↗

Wettability Effects on Primary Drainage Mechanisms and NAPL Distribution: A Pore-Scale Study

The pore-scale processes governing water drainage behavior in porous media have implications for geoscience multiphase scenarios including carbon capture and storage, contaminant site remediation, oil recovery, and vadose zone processes. However, few studies report directly observed pore-scale water drainage phenomena in 3-D soils. This knowledge gap limits our ability to verify assumptions underlying existing models and develop optimal solutions. As such, this paper utilizes synchrotron X-ray microtomography to present an experimental pore-scale examination of nonaqueous phase liquid (NAPL)/water distribution along a primary drainage front as dense NAPL was injected upward into water wetting (WW) and intermediate wetting (IW) sand-packed columns. Pore-network structures were extracted from imaged data sets and mapped onto segmented NAPL/water data sets which allowed quantitative examinations of wettability impacts on (a) the extent to which NAPL fills individual pore bodies and (b) relationships between pore size and the phase occupying the pore, with both considered as a function of distance (and capillary pressure) relative to the NAPL front. These results revealed that several hypotheses treating IW sand similarly to WW sands are simplistic. IW systems exhibited a sequence of pore filling that deviated from traditional capillary pressure-based model predictions: NAPL invades smaller pores, while larger, adjacent pores are bypassed leaving multipore residual water ganglia. NAPL pore saturations were close to 1 and did not change with capillary pressure in IW systems. Overall, the results illustrate how a relatively small change in operative contact angle alters NAPL distribution during water drainage, with important implications for geoscience multiphase flow scenarios.

58 GEOSCIENCES↗

Search for very-short-baseline oscillations of reactor antineutrinos with the SoLid detector

In this paper we report the first scientific result based on antineutrinos emitted from the BR2 reactor at SCK CEN. The SoLid experiment uses a novel type of highly granular detector whose basic detection unit combines two scintillators, polyvinyl toluene (PVT) and Li 6 F : ZnS ( Ag ) , to measure antineutrinos via their inverse- β -decay products. An advantage of PVT is its highly linear response as a function of deposited particle energy. The full-scale detector comprises 12 800 voxels and operates over a very short 6.3–8.9 m baseline from the reactor core. The detector segmentation and its three-dimensional imaging capabilities facilitate the extraction of the positron energy from the rest of the visible energy, allowing the latter to be utilized for signal-background discrimination. We present a result obtained from 280 reactor-on days (55 MW mean power) and 172 reactor-off days, respectively, of live data taking. A total of 29 479 ± 603 (stat) antineutrino candidates have been selected, corresponding to an average rate of 105 events per day and a signal-to-background ratio of 0.27. A search for disappearance of antineutrinos to a sterile state has been conducted using complementary model-dependent frequentist and Bayesian fits, providing constraints on the allowed region of the reactor antineutrino anomaly.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Ultra-scale vehicle tracking in low spatial-resolution and low frame-rate overhead video

Overhead persistent surveillance systems are becoming more capable at acquiring wide-field image sequences for long time-spans. The need to exploit this data is becoming ever greater. The ability to track a single vehicle of interest or to track all the observable vehicles, which may number in the thousands, over large, cluttered regions while they persist in the imagery either in real-time or quickly on-demand is very desirable. With this ability we can begin to answer a number of interesting questions such as, what are normal traffic patterns in a particular region or where did that truck come from? There are many challenges associated with processing this type of data, some of which we will address in the paper. Wide-field image sequences are very large with many thousands of pixels on a side and are characterized by lower resolutions (e.g. worse than 0.5 meters/pixel) and lower frame rates (e.g. a few Hz or less). The objects in the scenery can vary in size, density, and contrast with respect to the background. At the same time the background scenery provides a number of clutter sources both man-made and natural. We describe our current implementation of an ultrascale capable multiple-vehicle tracking algorithm for overhead persistent surveillance imagery as well as discuss the tracking and timing performance of the currently implemented algorithm which is aimed at utilizing grayscale electrooptical image sequences alone for the track segment generation.

42 ENGINEERING↗

Performance characterization of a MVCT scanner using multislice thick, segmented cadmium tungstate-photodiode detectors

Purpose: Megavoltage computed tomography (MVCT) and megavoltage cone beam computed tomography (MVCBCT) can be used for visualizing anatomical structures prior to radiation therapy treatments to assist in patient setup and target localization. These systems are less susceptible to metal artifacts and provide better CT number linearity than conventional CT scanners. However, their contrast is limited by the properties of the megavoltage photons and the low detective quantum efficiency (DQE) of flat panel detector systems currently available. By using higher DQE, thick, segmented cadmium tungstate detectors, the authors can improve the low contrast detectability of a MVCT system. This in turn would permit greater soft tissue visualization for a given radiation dose, allowing MVCT to be used in more clinical situations. Methods: This article describes the evaluation of our prototype system that uses thick, segmented detectors. In order to create images using a dose that would be acceptable for day to day patient imaging, the authors evaluated their system using the low intensity bremsstrahlung component of a 6 MeV electron beam. The system was evaluated for its uniformity, high contrast resolution, low contrast detectability, signal to noise ratio, contrast to noise ratio, and CT number linearity. Results: The prototype system was found to have a high contrast spatial resolution of about 5 line pairs per cm, and to be able to visualize a 15 mm 1.5% contrast target with 2 cGy of radiation dose delivered. SNR{sup 2} vs radiation dose and mean pixel value vs electron density curves were linear. Conclusions: This prototype system shows a large improvement in low contrast detectability over current MVCBCT systems.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Reconstruction of Dislocation Potential Relief by Means of Self-Blocking Effect

The effect of dislocation self-blocking in intermetallic compounds with an anomalous temperature dependence of yield stress has been theoretically and experimentally analyzed. In essence, this effect is a dislocation self-immersion in a deep potential relief valley (without external stress). The possibility of reconstructing the relief shape (from one-valley to two-valley) is shown and the relief parameters are reported. The allowed and forbidden regions for self-blocking are revealed. The method for determining the ratio of the valley depths by measuring the self-blocking limiting angles between the dislocation segments is proposed. Transmission electron microscopy images of the dislocation structure can be used to this end. As an example, this ratio is estimated for a superpartial dislocation sliding in the cube plane in Ni{sub 3}Ge.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

3D Imaging of Nickel Oxidation States using Full Field X-ray Absorption Near Edge Structure Nanotomography

Reduction-oxidation (redox) cycling of the nickel electrocatalyst phase in the solid oxide fuel cell (SOFC) anode can lead to performance degradation and cell failure. A greater understanding of nickel redox mechanisms at the microstructural level is vital to future SOFC development. Transmission x-ray microscopy (TXM) provides several key techniques for exploring oxidation states within SOFC electrode microstructure. Specifically, x-ray nanotomography and x-ray absorption near edge structure (XANES) spectroscopy have been applied to study samples of varying nickel (Ni) and nickel oxide (NiO) compositions. The imaged samples are treated as mock SOFC anodes containing distinct regions of the materials in question. XANES spectra presented for the individual materials provide a basis for the further processing and analysis of mixed samples. Images of composite samples obtained are segmented, and the distinct nickel and nickel oxide phases are uniquely identified using full field XANES spectroscopy. Applications to SOFC analysis are discussed.

30 DIRECT ENERGY CONVERSION↗

Compact single-shot soft X-ray photon spectrometer for free-electron laser diagnostics

The photon spectrum from free-electron laser (FEL) light sources offers valuable information in time-resolved experiments and machine optimization in the spectral and temporal domains. We have developed a compact single-shot photon spectrometer to diagnose soft X-ray spectra. The spectrometer consists of an array of off-axis Fresnel zone plates (FZP) that act as transmission-imaging gratings, a Ce:YAG scintillator, and a microscope objective to image the scintillation target onto a two-dimensional imaging detector. This spectrometer operates in segmented energy ranges which covers tens of electronvolts for each absorption edge associated with several atomic constituents: carbon, nitrogen, oxygen, and neon. The spectrometer’s performance is demonstrated at a repetition rate of 120 Hz, but our detection scheme can be easily extended to 200 kHz spectral collection by employing a fast complementary metal oxide semiconductor (CMOS) line-scan camera to detect the light from the scintillator. This compact photon spectrometer provides an opportunity for monitoring the spectrum downstream of an endstation in a limited space environment with sub-electronvolt energy resolution.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗