Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “High Temperature Methods”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,153 records · Page 64

A multiple pulse zero crossing NMR technique, and its application to F-19 chemical shift measurements in solids

A simple multiple-pulse 'zero crossing technique' for accurately determining the first moment of a solid-state NMR spectrum is introduced. This technique was applied to obtain the F-19 chemical shift versus pressure curves up to 5 kbar for single crystals of CaF2 (0.29 + or - 0.02 ppm/kbar) and BaF2 (0.62 + or - 0.05 ppm/kbar). Results at ambient temperature and pressure are also reported for a number of other fluorine compounds. Because of its high data rate, this technique is potentially several orders of magnitude more sensitive than similar CW methods.

Burum, D. P.↗

Perfluroether triazine elastomers

In order to obtain high performance elastomers with the high thermal stability and chemical inertness of perfluoroalkylene triazine and a low glass transition temperature, perfluoroether triazine elastomers were synthesized. The procedure for elastomer synthesis is described as well as general experimental methods. Results are presented and discussed. The screening of catalysts for the dehydration of perfluoroether diamide is also considered.

Korus, R. A.↗

Constitutive modeling for isotropic materials

The objective is to develop a unified constitutive model for finite element structural analysis of turbine engine hot-section components. This effort constitutes a different approach for non-linear finite-element computer codes which have heretofore been based on classical inelastic methods. The unified constitutive theory to be developed will avoid the simplifying assumptions of classical theory and should more accurately represent the behavior of superalloy materials under cyclic loading conditions and high temperature environments. During the first two years of the program, extensive experimental correlations were made with two representative unified models. The experiments were both uniaxial and biaxial at temperatures up to 1093 C (2000 F). In addition, the unified models were adopted to the MARC finite element code and used for stress analysis of notched bar and turbine blade geometries.

Lindholm, Ulric S.↗

The inflatable sphere - A technique for the accurate measurement of middle atmosphere temperatures

The present study illustrates the inflatable sphere's capability to produce accurate temperatures up to 85 km and higher, given that the necessary reduction initialization conditions are met. At heights below 60 km, comparison of sphere temperatures with in situ thermistor measurements obtained close in space and time shows good agreement. Comparison with OH-radical rotational temperatures also confirms excellent agreement at 86 km. It is concluded that the sphere technique is an independent and highly accurate source of temperature measurement, is unique in being the only low-cost source of in situ measurement of temperature throughout the mesosphere and lower thermosphere, and qualifies as an intrinsic method to establish the accuracy of other atmosphere measurement systems.

Schmidlin, F. J.↗

Local measurement of temperatures and concentrations: A review for hypersonic flows

The quality of reentry simulation for Shuttle, HERMES, Sanger, and NASP systematically suffers from the strong non-equilibrium of rotational and vibrational temperature due to the rapid acceleration of the test gas in the nozzle. Therefore the determination of temperatures is necessary and, if possible, preferable by a non-intrusive technique. The specific interests of this review are optical techniques such as electron beam fluorescence, laser-induced fluorescence, and coherent anti-Stokes Raman scattering. The capabilities available for local measurements with temporal resolution and quantitative accuracy are discussed for velocity, temperature, density, species concentrations, and fluctuations due to turbulence. The applicability of these methods of measurement is presented and discussed for the coming topic in aerothermodynamics: experimental techniques of hot gases in high enthalpy flows.

Dankert, C.↗

Preparation and characterization of poly (arylene ether isoxazole)s by fluoride ion-mediated aromatic nucleophilic displacement reactions

As part of a continuing effort to prepare novel thermally stable high-performance polymers, poly(arylene ether isoxazole)s have been prepared by fluoride ion-catalyzed aromatic nucleophilic substitution reactions with bis(trimethylsiloxyphenyl) isoxazoles and activated bisarylhalides in diphenyl sulfone. Initial investigation involving the preparation of these materials with isoxazole bisphenols and activated bisarylhalides in the presence of potassium carbonate indicated that, under reaction conditions necessary to prepare high-molecular-weight materials, the isoxazole monomer was converted to an enamino ketone. This side reaction was avoided by using fluoride as a base. However, trimethylsilyl ether derivatives of the isoxazole bisphenols were required in these polymerizations for the preparation of high-molecular-weight materials. Moderate to high inherent viscosity eta(sub inh): 0.43-0.87 dl/g) materials with good thermal stability (air: 409-477 C, helium: 435-512 C) can be prepared by the silyl ether method. Glass transition temperatures ranged from 182 to 225 C for polymers with phenyl pendants and from 170 to 214 C for those without. Molecular weight control by 2% endcapping and the incorporation of a phenyl pendant at the 4 position of the isoxazole is necessary to yield polymers soluble in polar aprotic solvents at room temperature. There is evidence, however, indicating the existence of crosslinks between the polymer chains when the silyl ether approach is utilized.

Herbert, C. G.↗

Powder Processing of High Temperature Cermets and Carbides at Marshall Space Flight Center

The Materials and Processing Laboratory at NASA Marshall Space Flight Center is developing Powder Metallurgy (PM) processing techniques for high temperature cermet and carbide material consolidation. These new group of materials would be utilized in the nuclear core for Nuclear Thermal Rockets (NTR). Cermet materials offer several advantages for NTR such as retention of fission products and fuels, better thermal shock resistance, hydrogen compatibility, high thermal conductivity, and high strength. Carbide materials offer the highest operating temperatures but are sensitive to thermal stresses and are difficult to process. To support the effort, a new facility has been setup to process refractory metal, ceramic, carbides and depleted uranium-based powders. The facility inciudes inert atmosphere glove boxes for the handling of reactive powders, a high temperature furnace, and powder processing equipment used for blending, milling, and sieving. The effort is focused on basic research to identify the most promising compositions and processing techniques. Several PM processing methods including Cold and Hot Isostatic Pressing are being evaluated to fabricate samples for characterization and hot hydrogen testing.

Salvail, Pat↗

Rad-Hard, Miniaturized, Scalable, High-Voltage Switching Module for Power Applications Rad-Hard, Miniaturized

A paper discusses the successful development of a miniaturized radiation hardened high-voltage switching module operating at 2.5 kV suitable for space application. The high-voltage architecture was designed, fabricated, and tested using a commercial process that uses a unique combination of 0.25 micrometer CMOS (complementary metal oxide semiconductor) transistors and high-voltage lateral DMOS (diffusion metal oxide semiconductor) device with high breakdown voltage (greater than 650 V). The high-voltage requirements are achieved by stacking a number of DMOS devices within one module, while two modules can be placed in series to achieve higher voltages. Besides the high-voltage requirements, a second generation prototype is currently being developed to provide improved switching capabilities (rise time and fall time for full range of target voltages and currents), the ability to scale the output voltage to a desired value with good accuracy (few percent) up to 10 kV, to cover a wide range of high-voltage applications. In addition, to ensure miniaturization, long life, and high reliability, the assemblies will require intensive high-voltage electrostatic modeling (optimized E-field distribution throughout the module) to complete the proposed packaging approach and test the applicability of using advanced materials in a space-like environment (temperature and pressure) to help prevent potential arcing and corona due to high field regions. Finally, a single-event effect evaluation would have to be performed and single-event mitigation methods implemented at the design and system level or developed to ensure complete radiation hardness of the module.

Adell, Philippe C.↗

Combined Thermomechanical and Environmental Durability of Environmental Barrier Coating Systems on SiC/SiC Ceramic Matrix Composites

Environmental barrier coatings (EBCs) and SiC/SiC ceramic matrix composites (CMCs) will play a crucial role in next generation turbine engines for hot-section component applications. The development of prime-reliant environmental barrier coatings is essential to the EBC-CMC system durability, ensuring the successful implementations of the high temperature and lightweight engine component technologies for engine applications.This paper will emphasize recent NASA environmental barrier coating and CMC developments for SiC/SiC turbine airfoil components, utilizing advanced coating compositions and processing methods. The emphasis has been particularly placed on thermomechanical and environment durability evaluations of EBC-CMC systems. We have also addressed the integration of the EBCs with advanced SiC/SiC CMCs, and studied the effects of combustion environments and Calcium-Magnesium-Alumino-Silicate (CMAS) deposits on the durability of the EBC-CMC systems under thermal gradient and mechanical loading conditions. Advanced environmental barrier coating systems, including multicomponent rare earth silicate EBCs and HfO2-Si based bond coats, will be discussed for the performance improvements to achieve better temperature capability and CMAS resistance for future engine operating conditions.

Ceramic Matrix Composites↗

Inertial Weldment of Rhenium and Inconel 718

Inertia welding has been found to be a successful method for joining pure rhenium to Inconel 718, and with additional experimentation, this process may have great potential for rocket nozzle applications. Refractory metals are ideally suited to this application, where high temperatures and oxidizing environment survivability is required, but not all of the thruster must be made of these materials, only the areas that require them. A bolted joint between the two metals is not ideal, especially for small thrusters where the mess of a bolted join will come at a steep price. A welded joint would be preferred for flight thrusters.

Cavender, D. P.↗

Results of Use of Heat Flux Sensors on Liquid Hydrogen Tanks

Heat flux sensors were used to characterize the performance of insulation on the Structural Heat Intercept, Insulation, and Vibration Evaluation Rig (SHIIVER), a large-scale test article designed to simulate upper stage cryogenic propellant tank thermal performance in simulated space environments. Usually, the insulation heat loads are derived from calculations removing all other heat sources and attributing the residual heat load to the insulation system. Testing for SHIIVER included the tank being just insulated with spray-on-foam insulation as well as covering the domes with multilayer insulation while leaving the barrel section insulated with spray-on-foam. Heat flux sensors were located at multiple locations on both domes as well as on the barrel section of the tank. Results from the SHIIVER testing using the heat flux sensors are compared to other calculated heat inputs for both liquid nitrogen and liquid hydrogen testing as a function of tank fill level. Further investigation into the transient nature of the SHIIVER testing including the heat flux sensors provided insight into heat flow patterns that may not have been otherwise seen using temperature sensors and calculated insulation heat loads. While the demonstrated uncertainties in the absolute values in the heat flux sensors are high, the values and the trends match well with other calculation methods. The results of SHIIVER allow for the use of heat flux sensors for measurements of insulation performance and dynamic system thermal response for future applications.

Cryogenic Fluid Management↗

Results of Use of Heat Flux Sensors on Liquid Hydrogen Tanks

ABSTRACT: Heat flux sensors were used to characterize the performance of insulation on the Structural Heat Intercept, Insulation, and Vibration Evaluation Rig (SHIIVER), a large-scale test article designed to simulate upper stage cryogenic propellant tank thermal performance in simulated space environments. Usually, the insulation heat loads are derived from calculations removing all other heat sources and attributing the residual heat load to the insulation system. Testing for SHIIVER included the tank being just insulated with spray-on-foam insulation as well as covering the domes with multilayer insulation while leaving the barrel section insulated with spray-on-foam. Heat flux sensors were located at multiple locations on both domes as well as on the barrel section of the tank. Results from the SHIIVER testing using the heat flux sensors are compared to other calculated heat inputs for both liquid nitrogen and liquid hydrogen testing as a function of tank fill level. Further investigation into the transient nature of the SHIIVER testing including the heat flux sensors provided insight into heat flow patterns that may not have been otherwise seen using temperature sensors and calculated insulation heat loads. While the demonstrated uncertainties in the absolute values in the heat flux sensors are high, the values and the trends match well with other calculation methods. The results of SHIIVER allow for the use of heat flux sensors for measurements of insulation performance and dynamic system thermal response for future applications.

Cryogenic Fluid Management↗

Thermodynamic and Diffusion Model Estimates on Metamorphic Temperatures and Timescales for Basaltic Eucrite GRA 98098

Introduction: HED meteorites are thought to rep-resent igneous rocks from Vesta’s basaltic crust and preserve evidence of early crustal metamorphism. Determining the temperatures and timescales of thermal metamorphism is important for reconstructing crustal evolution in the early solar system. Here, we study basaltic eucrite Graves Nunataks (GRA) 98098, which has been identified as a highly metamorphosed eucrite [1]. We present new estimates on metamorphic temperatures determined via thermodynamic modeling as well as the initial results from diffusion models constraining timescales of thermal metamorphism. Sample Description: GRA 98098 is an unbrecciated eucrite with a granoblastic plagioclase and pyroxene mineralogy. Millimeter to cm-long lathes of tridymite cross-cut and poikilitically enclose plagioclase and pyroxene [1,this work]. Pyroxene grains have exsolved into Ca-rich (~Wo38En29Fs33) and Ca-poor (~Wo4.5En36Fs59.5) lamellae. Both unzoned and zoned plagioclase grains are observed. Unzoned plagioclase grains are found solely with tridymite laths. These grains have ~An92 compositions. The cores of the zoned plagioclase grains have the same composition and thin, relatively sodic rims (~An67), (Fig. 1). The bulk sample is unusually enriched in highly in-compatible elements and has one of the most fractionated REE patterns reported [1]. Maximum metamorphic temperatures of 985±78°C have been estimated using two-pyroxene thermometry [2]. Methods: Thermodynamic modeling. Thermodynamic models were constructed using the software Perple_X, which employs a Gibbs free energy minimization in order to determine the most stable phase assemblage for a given bulk rock composition [3]. Bulk composition was calculated using mineral com-positions acquired via EMPA (this study) and the observed abundancies present in the thin section. Two bulk compositions were estimated; 1) includes all phases present in the thin section, (assumes that all phases are present during metamorphism), 2) excludes tridymite from the bulk calculation (assumes that tridymite was not present during metamorphism). In order to determine whether metamorphic equilibria was achieved and estimate temperatures of metamorphism, we compared measured pyroxene compositions with thermodynamically predicted compositions [4, Fig. 2]. Diffusion Modeling. Several time-temperature de-pendent diffusion profiles were calculated in order to determine the best match for XAn chemical profiles observed at the edges of the zoned plagioclase (Fig. 3). We assumed that the start condition was a stepwise gradient at the plagioclase/pyroxene interface. We also assumed an average diffusion coefficient (D) and a constant temperature using the equation in [5]. D was determined for two temperatures (T = 1060ºC; near eucrite solidus [6] and T = 985ºC; metamorphism reported in [4]) and then XAn was calculated as a function of distance from plagioclase core to rim using an error function solution to Fick’s second law. Results: Thermodynamic model results are summarized in Fig. 2. For a bulk composition that includes all phases in the thin section, pyroxene endmember compositions plot in the following temperature ranges: Fs ~660-860ºC, En~1000ºC & 1150ºC, and Wo~760-900ºC (Fig. 2a). For a bulk composition that excludes tridymite from the peak metamorphic assemblage (i.e., the bulk composition minus the contribution from tridymite), a temperature range could not be determined for the Fs component of pyroxene. For Wo, T~760-900ºC and En, T~1000ºC & 1150ºC (Fig. 2b). Fig. 3 summarizes the diffusion model results. For T = 1060°C & 985°C, the most appropriate time interval was estimated based on which diffusion curve most matched (solid lines, Fig. 3) the EMPA data. For T = 1060°C, the best looking match was t = 500 ka. For T = 985°C, the best match was t = 7 Ma. Discussion and future work: Temperature estimates from thermodynamic models are not conclusive because the temperature ranges determined for pyroxene endmember stability do not overlap (colored fields in Fig. 2), thus implying that there is disequilibrium between pyroxene crystals and the bulk composition considered [4]. Thus, additional exploration is needed to define a metamorphically equilibrated do-main that accurately records peak temperature. The utility of defining metamorphically equilibrated do-mains to improve the accuracy and level of detail elucidated regarding the petrogenetic history of metamorphose samples has been demonstrated previously [4,7]. We suggest that in the case of Fig. 2a, the thin section composition is not representative of the length scales over which metamorphic equilibrium was achieve and in the case of Fig. 2b, the assumption that tridymite was not present during metamorphism was incorrect. However, results from thermodynamic models can provide insight into the relative timing of mineral and compositional textures. For example from texture alone, it is unclear whether tridymite was igneous in origin and represents the last bits of melt in a crystallizing magma chamber, or if it formed during (and possibly initiated) open system thermal metamorphism. The latter could be consistent with a partial melt hypothesis [8,9] while the former implies that simple fractional crystallization can yield the textures present in GRA 98098. The lack of coincidence be-tween pyroxene endmember compositions in Fig. 2b suggest that the bulk composition minus tridymite was not the assemblage in equilibrium with the pyroxene, suggesting that tridymite was present during metamorphism and formed during igneous crystallization. We conclude that the development of the Na-rich plagioclase rims likely occurred during or immediately after peak thermal metamorphism, because eucrites of similar metamorphic grade and texture have unzoned plagioclase (~An92) [2,4,8], and Na zoning is only observed in the plagioclase not included in the tridymite. This suggests that the zoning formed after tridymite formation, and therefore after igneous crystallization. Thus, the timescales calculated via diffusion modeling possibly represent the time interval over which thermal metamorphism occurred. Cooling rates approximated for the Vestan crust predict that the crust cooled below 300°C around 35-40 Ma after formation[10]. This is consistent with our modeling results that predict formation of the Na rich plagioclase rims occurring at higher temperatures over a period of 0.5 to 7 Ma years. Future work. Additional thermodynamic modeling work will focus on selecting an equilibrated bulk rock domain in which to elucidate metamorphic conditions. Diffusion models currently provide a minimum time-scale, since diffusion slows down as the system cools. Future work with will focus on integrating cooling into the diffusion models and constraining the depth at which thermal metamorphism occurs because it could be used to determine whether the range of time-scales calculated for thermal metamorphism are consistent with the geologic environment.

J S Gorce↗

TARDIS: Acelerating TVAC Transitions

"Large spacecraft components, including instruments, require long durations to transition between temperature plateaus during TVAC (Thermal Vacuum) testing. This is especially true for cryogenic instruments whose operating temperatures are extremely low. Due to the T4 relation, using radiative heat transfer alone for temperature transitions to cryogenic temperatures is extremely time consuming. The Wide Field Instrument (WFI) on the upcoming Roman Space Telescope (RST) is one such cryogenic instrument. The TARDIS (Thermal Acceleration Rate Device for Integrated Systems) is a heat switch device which will be used during the WFI TVAC test campaign in order to decrease WFI transition times. Over the course of the planned ___ week WFI instrument-level TVAC testing, TARDIS is being estimated to save ___ days of test time. By reducing the total TVAC duration, TARDIS is providing significant cost and schedule savings to the RST WFI project. Based on the successful design of the LUCY L’Ralph AZQ Heat Switch, TARDIS can provide both high conductivity for temperature transitions and low conductivity Zero-Q for thermal balances. This is achieved by use of a mechanical clamp heat switch and actively controlled cold plate. Using this method, TARDIS is estimated to be able to change its conductance from approximately 0.20 W/K to ¬¬0.002 W/K, for a turndown ratio of 100. This paper details the design, analysis, and testing of TARDIS. It also previews the operation of TARDIS in the upcoming WFI TVAC test campaign. "

TVAC, Heat Switch↗

Containerless measurements on liquids at high temperatures

The application of containerless techniques for measurements of the thermophysical properties of high temperature liquids is reviewed. Recent results obtained in the materials research laboratories at Intersonics are also presented. Work to measure high temperature liquid properties is motivated by both the need for reliable property data for modeling of industrial processes involving molten materials and generation of data form basic modeling of materials behavior. The motivation for this work and examples of variations in thermophysical property values from the literature are presented. The variations may be attributed to changes in the specimen properties caused by chemical changes in the specimen and/or to measurement errors. The two methods used to achieve containerless conditions were aeroacoustic levitation and electromagnetic levitation. Their qualities are presented. The accompanying slides show the layout of levitation equipment and present examples of levitated metallic and ceramic specimens. Containerless techniques provide a high degree of control over specimen chemistry, nucleation and allow precise control of liquid composition to be achieved. Effects of minor additions can thus be measured in a systematic way. Operation in reduced gravity enables enhanced control of liquid motion which can allow measurement of liquid transport properties. Examples of nucleation control, the thermodynamics of oxide contamination removal, and control of the chromium content of liquid aluminum oxide by high temperature containerless processes are presented. The feasibility of measuring temperature, emissivity, liquidus temperature, enthalpy, surface tension, density, viscosity, and thermal diffusivity are discussed in the final section of the paper.

Weber, Richard↗

Thermodynamic Measurements Using the Knudsen Cell Technique

The Knudsen cell technique has been used for over a century and is a valuable tool for measurement of vapor pressures and thermodynamic properties. It is based on a small enclosure (~1 cm long x 1 cm diameter) in which a condensed phase/vapor equilibria can be established. A small (<1 mm) orifice on the cell allows sampling of the vapor via a variety of techniques including weight loss, torsion effusion, target collection, and mass spectrometry. Many excellent measurements based on these methods have been reported. However in order to obtain reliable measurements, a variety of factors must be considered. They include proper cell material selection, accurate and uniform temperature control and measurement, and proper sampling of the vapor. Each of these factors are discussed in detail in this chapter. Typically these studies are conducted at high temperatures and it is a challenge to select an inert container material. Recommended materials are discussed and in some cases the container may be used as part of the system under study. Temperature control and measurement is perhaps the most important issue. In most systems, the furnace must be compact yet there can be no temperature gradient in the cell. Temperatures are measured with either a thermocouple or pyrometer and the relative advantages of each are discussed. Sampling method considerations depend on the particular technique. It is essential that all of the vapor or a representative portion of the vapor be sampled. The distribution of the effusate from a Knudsen cell is discussed and sampling positions discussed. Mass spectrometry is often used to study the effusing vapor and the relations between ion current and vapor pressure are discussed.

mass spectrometry↗

Three-dimensional tracking solar energy concentrator and method for making same

A three dimensional tracking solar energy concentrator, consisting of a stretched aluminized polymeric membrane supported by a hoop, was presented. The system is sturdy enough to withstand expected windage forces and precipitation. It can provide the high temperature output needed by central station power plants for power production in the multi-megawatt range.

Miller, C. G.↗

Observations on the dynamics of electromagnetically levitated liquid metals and alloys at elevated temperatures

Electromagnetic levitation and heating of small (0.5 to 1.0 gm) samples of Cu, Ni, and Ni-base alloys were performed in inert atmospheres. These experiments were recorded by high-speed photography using both regular film and video methods. Initial studies revealed interesting dynamics of the droplets that included axisymmetric oscillation, rotation, and oscillation mode changes. An attempt is made to explain the behavior using available models.

Hansen, G. P.↗