Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Grids”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,153 records · Page 64

Grid-based diffusion Monte Carlo for fermions without the fixed-node approximation

A diffusion Monte Carlo algorithm is introduced that can determine the correct nodal structure of the wave function of a few-fermion system and its ground-state energy without an uncontrolled bias. This is achieved by confining signed random walkers to the points of a uniform infinite spatial grid, allowing them to meet and annihilate one another to establish the nodal structure without the fixed-node approximation. An imaginary-time propagator is derived rigorously from a discretized Hamiltonian, governing a non-Gaussian, sign-flipping, branching, and mutually annihilating random walk of particles. The accuracy of the resulting stochastic representations of a fermion wave function is limited only by the grid and imaginary-time resolutions and can be improved in a controlled manner. Here, the method is tested for a series of model problems including fermions in a harmonic trap as well as the He atom in its singlet or triplet ground state. For the latter case, the energies approach from above with increasing grid resolution and converge within 0.015 E h of the exact basis-set-limit value for the grid spacing of 0.08 a.u. with a statistical uncertainty of 10 –5 E h without an importance sampling or Jastrow factor.

74 ATOMIC AND MOLECULAR PHYSICS↗

Towards time-resolved MicroED grid preparation using mix-and-inject gas dynamic virtual nozzles

Recent progress in gas dynamic virtual nozzle (GDVN) technologies in combination with high-brilliance synchrotron and X-ray free-electron lasers (XFELs) has allowed the visualization of protein dynamics in crystallo by mixing macromolecular protein crystals with a substrate using tunable mixing times on the order of milliseconds to seconds prior to serial X-ray diffraction data collection. This has become the method of choice for high-resolution structure determination of intermediate states. However, such experiments require large counts of crystals of proper sizes for high-resolution data collection, and premium beam times for screening efforts. Cryogenic microcrystal electron diffraction (MicroED) represents a complementary technique that may be a more accessible avenue for time-resolved nanocrystallography compared with serial X-ray diffraction experiments. MicroED can produce full diffraction datasets from just a few submicrometre-thick crystals, and the approach is more readily accessible, requiring standard cryogenic transmission electron microscopy (TEM) equipment available at many universities and institutes. Cryogenic MicroED, like other forms of cryo-EM, begins with rapidly freezing biological material on electron microscopy grids. In the case of MicroED, micro- to nano-crystals (<500 nm thick) are deposited onto electron microscopy grids and plunge-frozen for subsequent electron diffraction data collection. Here, we have incorporated GDVN technology developed originally for XFEL experiments into the freezing process as a first step towards time-resolved studies. We describe the limited deposition efficiency of the model MicroED protein proteinase K on TEM grids using GDVNs, preceding sample vitrification and successful MicroED data collection. We discuss both the initial results from such experiments and the methodological challenges in developing this approach into a reliable workflow for millisecond-to-second time-resolved structural studies of macromolecules. Our results promise a strategy to deposit crystals on grids using GDVNs and determine high-resolution structures by MicroED, constituting a first step towards development of time-resolved MicroED experiments.

MicroED↗

Medium Voltage Converter Inductor Insulation Design Considering Grid Insulation Requirements

Medium voltage SiC devices facilitate direct (without 50/60 Hz transformer) connection of the power electronics converter to the medium voltage grid using simple topology. Compared to the insulation design of medium voltage inductors that have been widely used in the power system, the insulation design of directly connected medium voltage converter filter inductors has more challenges. Although some works has been done discussing that, the grid insulation requirements on converter filter inductors are rarely discussed. This paper introduces the insulation design of a grid-side filter inductor for a 13.8 kV power conditioning system converter. The grid insulation requirements, including the short-duration power frequency overvoltage and the lightning impulse voltage, are considered in the design. To meet the requirements, the layer-to-layer insulation, winding-to-core/ground insulation, the air gap discharge between the winding and the core, as well as the local electrical field have been taken into consideration. Experimental tests are provided to validate the design.

Li, Haiguo↗

The Impact of the Lightning Surge on SiC-based Medium-voltage Three-phase Four-wire Grid-connected Converters

The surge voltage induced by lightning will generate an inrush current in a grid-connected converter. It may not be large in Si-based converters because of the large grid side inductive filter. However, for SiC-based multi-level converters, the inrush current could be very large due to the small filter inductance, which is selected based on the current harmonic consideration. Most previous work focuses on system-level lightning protection while the converter-level impact, especially the internal components of the converter, is rarely discussed. This paper presents the analysis of the impact of the lightning surge on a 10 kV SiC MOSFET-based 13.8 kV three-phase four-wire grid-connected converter. The IEEE arrester model and the combined wave generator model in IEC 61000-4-5 standard are used to evaluate the inrush current, DC-link overvoltage, and component-to-ground potential of the converter. Analysis and simulation results have been provided to demonstrate the impact of lightning on the grid-connected converter. It is found that large inrush current occurs due to the small filter inductance, and the neutral-to-ground impedance impacts both the inrush current and the neutral point-to-ground potential.

Li, Haiguo↗

A Novel Bi-directional AC/DC - DC/AC Wireless Power Transfer System for Grid Support Applications

The severity of the economic impact caused by grid outages has been the driving factor for creating innovative solutions that increases interest for the deployment of distributed energy resources to reduce the impact of grid outages. This paper presents a novel topology for providing export power applications. Proposed topology can be used for grid (primary)-side of bi-directional wireless power transfer (WPT) systems, mobile energy storage systems (ESSs), and electric vehicle (EV) batteries. The proposed concept here achieves energy transfer between sources by using a hybrid frequency bi-directional ac/dc converter without an additional front-end converter stage compared to the conventional systems. Due to inherent merit of the proposed bi-directional ac/dc converter, ac input with 60 Hz grid frequency can be directly transferred through the wireless coils and can be directly converted to the dc. Results demonstrate the performance and the functionality of the single-phase bi-directional system with the input / output of 110 V ac,rms and 200 V dc at 1 kW power. Full paper will demonstrate the converter operation at 10 kW power level with additional features and control aspects.

Asa, Erdem↗

Grid-Forming Storage Networks: Analytical Characterization of Damping and Design Insights

Grid-forming storage resources are critical to the operation of power grids with high renewable penetration. Over the years, there has been considerable emphasis on understanding the benefits these inverter-based storage resources bring towards managing volatility and enhancing grid reliability but little is studied about the supplementary advantages latent in their operation. This paper investigates one such application in which we explore the impact of grid-forming distributed storage in damping low-frequency inter-area oscillations. We present a detailed analysis characterizing the impact of inverter-droop and storage size on the slower eigenvalues, highlighting potential design considerations for enhancing system stability.

Chatterjee, Kaustav [BATTELLE (PACIFIC NW LAB)] (O↗

Medium Voltage Energy Hub Based on Multilevel Cascaded H Bridge-Dual Active Bridge Back-to-Back Converter for Power Distribution Feeders Interconnection and Multiple Simultaneous Grid Services

This paper presents a medium voltage energy hub based on a modular design of a multilevel cascaded H bridge (CHB)-dual active bridge (DAB) converter. The energy hub composed of the two CHB-DAB modules with a back-to-back topology can be utilized as a grid interconnection component between distribution feeders. The energy hub can provide multiple simultaneous grid services such as voltage regulation, power factor correction, as well as active power flow control between the connected feeders, contributing to grid flexibility, efficiency, reliability, and resilience. Circuit structure and control schemes for the energy hub including both local controllers for each converter and outer loop controllers are proposed to enable simultaneous grid services with coordination to prevent the overloading of the hub. To validate the performance of the hub, the hub system is interconnected between two IEEE 4-bus feeders and provides voltage regulation for both feeders, while controlling active power flow between them. The system and the feeders are implemented in Real-Time Digital Simulator (RTDS) for real-time simulation verification.

Choi, Jongchan↗

Detection of Cyber Attacks in Grid-tied PV Systems Using Dynamic Watermarking

This paper presents of an active detection scheme for detecting cyber attacks on sensors controlling a grid-tied PV systems. Several cyber vulnerabilities in Grid tied PV Systems are discussed. The defense mechanism introduces a private (secret) watermarking signal into the control inputs of the grid-tied inverter system. This will enable the detection of any malicious manipulation of sensor measurements. Based on the measured data, two statistical tests are conducted to identify anomalies in the system using the presence of the watermarking signal. It shown that when a sensor data is compromised and/or replaced by a pre-recorded healthy signal, both test 1 and 2 exhibit high values indicating a possible malicious activity. The robustness of the proposed algorithm is tested and validated with several attack scenarios on a grid tied PV system. Select results from an experimental setup are discussed.

Ibrahim, Hasan↗

SNNPG: Using Spiking Neural Networks to Detect Attacks in the Power Grid

We explore the potential of Spiking Neural Networks (SNN) to enhance the security of power grid operations by detecting False Data Injection (FDI) attacks. These attacks manipulate PMU readings, leading to erroneous control decisions and grid disruptions. We develop a method to convert Phase Measurement Unit (PMU) data into spike trains, capturing both temporal and spatial dimensions. Using an SNN model, we conduct evaluations with simulated power grid data, showcasing accuracy in detecting FDI attacks. SNN models rapidly identify anomalies in real-time PMU data, safeguarding grid operations by alerting operators to irregular readings and preventing incorrect decisions.

artificial intelligence↗

Behavior of Multiple PV Plants in Future Power Grids During Events

As the integration of multiple photovoltaic (PV) plants into power grids grows, the dynamic response of each plant and their interactions during transient events demands a deeper understanding. In this paper, the dynamic behavior of multiple PV plants connected to future power grids is comprehensively explored using site-specific high-fidelity electromagnetic transient (EMT) PV plant models and generic high-fidelity EMT PV plant models. This research demonstrates the need to employ multiple high-fidelity EMT PV plant models to understand the intricate interactions between multiple PV plants during grid events. These models, developed in Fortran within the PSCAD environment, encompass a range of operational scenarios and plant configurations, offering invaluable insights crucial for future system planning with multiple PV plants to enhance grid stability.

Marthi, Phani Ratna Vanamali [ORNL] (ORCID:0000000↗

Positive-Sequence Phasor Modeling of Droop-Controlled, Grid-Forming Inverters with Fault Current Limiting Function

Traditional positive-sequence phasor models of droop-controlled, grid-forming inverters do not have the fault current limiting function. During a short-circuit fault the model generates unrealistic high fault current making the simulation results less practical. This paper develops a fault current limiting function for the positive-sequence phasor model of droop-controlled, grid-forming inverters, which can effectively limit the inverter output current at the predefined maximum during faults. A user-written model has been developed for the commercially-available software Siemens/PTI PSS/E. Fault studies on a modified IEEE 39-bus system with all grid-forming inverters verify the effectiveness of the developed fault current limiting function. The proposed model can be used to evaluate how the limited fault currents of droop-controlled, grid-forming inverters impact the bulk power system transient stability under fault conditions.

Du, Wei↗

Analysis of Transformer Magnetizing Reactance Using Describing Function in Direct Power Control of Back-to-Back Modular Multilevel Converter with Advanced Grid Support

This paper presents a Port Controlled Hamiltonian based direct power control architecture for a back-to-back modular multilevel converter system connecting two ac sources at different frequencies. The system features advanced grid support functionalities based on IEEE 1547-2018, implemented on the inverter side. The rectifier side controller ensures reference following for active and/or reactive powers and maintains the commanded dc bus voltage. The inverter side controller ensures power command following for active and reactive powers.The proposed control architecture is designed to suppress second harmonic oscillations in powers during unbalanced grid voltage sags by dynamically adjusting the currents on each ac side. This also ensures effective elimination of any second harmonic oscillations in the equivalent dc bus voltage. Validation is performed on an OPAL-RT real-time platform with case studies on unbalanced and balanced sags, demonstrating the controller's effectiveness during real time implementation. A reduced-scale laboratory prototype further verifies these case studies, with experimental results for balanced sags due to grid simulator limitations. The results confirm the robustness and efficiency of the proposed control strategy in ensuring stable and reliable operation under various grid conditions.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Model Residuals as Shields: A Two-Level Formulation to Defend Smart Grids From Poisoning Attacks

The advancement of smart grids presents both vast opportunities and heightened cybersecurity risks. Data-driven defense mechanisms, though designed as a shield against these threats, can fall prey to poisoning attacks. We delve into regression settings, underscoring the imperative to fortify defenses against a spectrum of poison ratios, notably those above 0.5—an issue scarcely addressed in prior studies. Recognizing the susceptibilities of smart grids and their manipulable sensors, we exploit the very intent of poisoning attacks, compromising model accuracy, as our defense mechanism. Our proposed two-level optimization framework discerns between poisoned and authentic data based on model residuals, outperforming or matching existing methods in 72% to 77% of precision and 75% to 80% of recalls across various poisoning attacks, poison ratios, and datasets. Once the authentic data are identified, the trained model is adaptable for a variety of applications. Comprehensive evaluations on different smart grid datasets, pitted against myriad poisoning schemes, validate our methodology’s edge over existing methods. Here, we also shed light on the implications of model misspecification originating from temporal auto-correlation, a common feature in Internet of Things and smart grid data.

Adversarial machine learning (ML)↗

Grid-Forming Frequency Shaping Control for Low-Inertia Power Systems

As power systems transit to a state of high renewable penetration, little or no presence of synchronous generators makes the prerequisite of well-regulated frequency for grid-following inverters unrealistic. As such, there is a trend to resort to grid-forming inverters which set frequency directly. We propose a novel grid-forming frequency shaping control that is able to shape the aggregate system frequency dynamics into a first-order one with the desired steady-state frequency deviation and Rate of Change of Frequency (RoCoF) after a sudden power imbalance. The no overshoot property resulting from the first-order dynamics allows the system frequency to monotonically move towards its new steady-state without experiencing frequency Nadir, which largely improves frequency security. We prove that our grid-forming frequency-shaping control renders the system internally stable under mild assumptions. The performance of the proposed control is verified via numerical simulations on a modified Icelandic Power Network test case.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Power Grid Reliability Estimation via Adaptive Importance Sampling

Electricity production currently generates approximately 25% of greenhouse gas emissions in the USA. Thus, increasing the amount of renewable energy is a key step to carbon neutrality. However, integrating a large amount of fluctuating renewable generation is a significant challenge for power grid operating and planning. Grid reliability, i.e., an ability to meet operational constraints under power fluctuations, is probably the most important of them. In this letter, we propose computationally efficient and accurate methods to estimate the probability of line overflow, i.e., reliability constraints violation, under a known distribution of renewable energy generation. To this end, we investigate an importance sampling approach, a flexible extension of Monte-Carlo methods, which adaptively changes the sampling distribution to generate more samples near the reliability boundary. The approach allows to estimate overload probability in real-time based only on a few dozens of random samples, compared to thousands required by the plain Monte-Carlo. Our study focuses on high voltage direct current power transmission grids with linear reliability constraints on power injections and line currents. Herein, we propose a novel theoretically justified physics-informed adaptive importance sampling algorithm and compare its performance to state-of-the-art methods on multiple IEEE power grid test cases.

power system faults↗

Experimental Setup for Grid Control Device Software Updates in Supply Chain Cyber-Security

Supply chain cyberattacks that exploit insecure third-party software are a growing concern for the security of the electric power grid. These attacks seek to deploy malicious software in grid control devices during the fabrication, shipment, installation, and maintenance stages, or as part of routine software updates. Malicious software on grid control devices may inject bad data or execute bad commands, which can cause blackouts and damage power equipment. This paper describes an experimental setup to simulate the software update process of a commercial power relay as part of a hardware-in-the-loop simulation for grid supply chain cyber-security assessment. The laboratory setup was successfully utilized to study three supply chain cyber-security use cases.

Keller, Joseph↗

Generalized Power Flow Model of an Extra High-Power Multi-Terminal HVdc Transmission Grid with Parallel-Connected and Voltage-Stacked Converters

To increase power transfer capacity of high-voltage direct current (HVdc) transmission, a new extra high-power HVdc architecture with multiple standard modular multilevel converters (MMCs) per substation has recently been introduced. This paper proposes a power flow model for a multi-terminal HVdc (MTdc) grid with this innovative substation architecture. The proposed MTdc model can be integrated seamlessly with existing ac-dc power flow algorithms with minimal modifications. The model is applicable to various MTdc grid types and topologies, different numbers of dc buses, dc lines, and MMCs per substation, along with diverse control parameters. In addition, it accurately captures both balanced and unbalanced operations of the MTdc grid. The proposed model is verified using a 5-terminal bipole MTdc grid that spans 4 areas in the Eastern Interconnection system of the USA. The numerical solutions obtained from unified and sequential ac-dc power flow algorithms under different operating conditions closely match the time-domain simulation results in PSCAD, validating the accuracy and versatility of the proposed MTdc power flow model.

Nguyen, Quan H.↗

A Co-Simulation Framework for Steady-State Analyses of Multiple Droop-based MTdc Grids in Continental-Scale Systems

The growing scale and complexity of planning continental hybrid ac and multi-terminal dc (MTdc) systems require scalable steady-state modeling and analysis approaches not currently available in commercial tools. This paper presents a comprehensive multi-fidelity model-conversion framework that enables the efficient transition of MTdc grid models from production cost modeling (PCM) and approximated ac power flow to detailed ac–MTdc power flow for large-scale planning studies. The core of this framework is a scalable co-simulation approach that, for the first time, enables power flow analysis in continental-scale ac–MTdc systems. It seamlessly couples commercial ac solvers with a detailed MTdc grid model that incorporates droop-based control and current-limiting strategies of multiple meshed MTdc grids. Leveraging this capability, an evaluation framework to systematically assess and compare different MTdc power redispatch strategies under ac and dc contingencies is introduced. The proposed framework and algorithm are evaluated using a combined Western and Eastern Interconnection system with 11 MTdc grids of various sizes, showing a coherent transition from PCM to detailed ac–MTdc power flow and improved system performance in voltage regulation and line overload mitigation following typical contingencies.

Nguyen, Quan H.↗