Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “GUIDANCE”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,153 records · Page 64

Monitoring the effectiveness of floodplain habitat restoration: A review of methods and recommendations for future monitoring

Abstract Floodplains are some of the most ecologically important and human‐impacted habitats throughout the world. Large efforts are underway in North America, Europe, Australia, and elsewhere to restore floodplain habitats, not only to increase fish and aquatic biota but to restore ecological diversity. As the scale, number, and complexity of floodplain restoration projects has increased, so has the need for rigorous monitoring and evaluation to demonstrate effectiveness and guide future floodplain restoration efforts. Moreover, technological advances in remote sensing, genetics, and fish marking have been evolving rapidly and there is need to update guidance on the best methods for monitoring physical and biological response to floodplain restoration. A comprehensive review of the restoration literature located 180 papers that specifically examined the effectiveness of various floodplain restoration techniques. The various methods that were historically and currently used to evaluate the physical (channel and floodplain morphology, sediment, flow, water quality [temperature and nutrients]) and biological (fish, invertebrates, and aquatic and riparian plants) effectiveness of floodplain restoration were reviewed and used to provide recommendations for future monitoring. For each major physical and biological monitoring method, we discuss their importance, how they have historically been used to evaluate floodplain restoration, newer methodologies, and limitations or advantages of different methodologies and approaches. We then discuss monitoring the effectiveness of small (<2 km in main channel length) and large (>2 km of main channel length) floodplain projects, with recommendations for various study designs, parameters, and monitoring methodologies. This article is categorized under: Water and Life > Conservation, Management, and Awareness Water and Life > Methods

Roni, Philip↗

A review of modelling techniques for floating offshore wind turbines

Modelling floating offshore wind turbines (FOWTs) is challenging due to the strong coupling between the aerodynamics of the turbine and the hydrodynamics of the floating platform. Physical testing at scale is faced with the additional challenge of the scaling mismatch between Froude number and Reynolds number due to working in the two fluid domains, air and water. In the drive for cost-reduction of floating wind energy, designers may be seeking to move towards high-fidelity numerical modelling as a substitute for physical testing. However, the numerical engineering tools typically used for FOWT modelling are considered as mid-fidelity to low-fidelity tools, and currently lack the level of accuracy required to do so. Furthermore, there is a lack of operational FOWT data available for further development and validation. High-fidelity tools, such as CFD, have greater accuracy but are cumbersome tools and still require validation. Physical scale model testing therefore continues to play an essential role in the development of FOWTs both as a source of validation data for numerical models and as an important development step along the path to commercialization of all platform concepts. The aim of this paper is to provide an overview of both numerical modelling and physical FOWT scale model testing approaches and to provide guidance on the selection of the most appropriate approach (or combination of approaches). The current state-of-the-art will be discussed along with current research trends and areas for further investigation.

17 WIND ENERGY↗

Earliest Traces of Life as a Window on Life's Origins

Life is the outcome of a complex network of chemical reactions and mo-lecular interactions that emerged on Earth once primitive chemical automata could self-assemble in such a way that enabled them to self-reproduce and evolve. Yet exactly how, where and when life first appeared on our planet remains unknown. Various lines of evidence from fossilized traces of early life preserved in the geological record provide fundamental, albeit often rudimentary, insight into early life. The oldest fossils record the nature of life more than half a billion years after it emerged on Earth and suggest that considerable metabolic diversity had already evolved by this time. Microfossils, microbial mats, stromatolites and organic and inorganic geochemical signatures have been interpreted as compelling evidence for Archean biodiversity. In spite of the chemical enigmas of the earliest life and its limited record, characterization of the various classes of biosignatures indicative of life in its geological context provides guidance as to the earliest co-evolution of the geosphere and biosphere.

Cavalazzi, Barbara↗

Federated Learning with Frequency Estimation for Smart Meter Systems

Federated learning (FL) is a powerful framework that enables multiple distributed clients to collaborate without the need to transfer their data to a central server. However, FL does not inherently guarantee the level of privacy that clients often require. In our review of recent studies on privacy-enhancing techniques in FL, we found that frequency estimation (FE) methods remain underexplored. To address this gap, we developed and integrated FE techniques on the client side, further examining the effects of incorporating an adaptive range and a shuffled model. We also analyzed the impact of varying hyper-parameters on privacy preservation. Our results provide clear guidance on the algorithms and configurations that are most effective for enhancing privacy in FL, particularly when using long short-term memory (LSTM) architectures.

Kotevska, Olivera [ORNL] (ORCID:0000000316772243)↗

Implementing an Information Security Program

The threats to information security have dramatically increased with the proliferation of information systems and the internet. Chemical, biological, radiological, nuclear, and explosives (CBRNe) facilities need to address these threats in order to protect themselves from the loss of intellectual property, theft of valuable or hazardous materials, and sabotage. Project 19 of the European Union CBRN Risk Mitigation Centres of Excellence Initiative is designed to help CBRN security managers, information technology/cybersecurity managers, and other decision-makers deal with these threats through the application of cost-effective information security programs. Project 19 has developed three guidance documents that are publically available to cover information security best practices, planning for an information security management system, and implementing security controls for information security.

blended attack↗

Molière scattering in quark-gluon plasma: finding point-like scatterers in a liquid

By finding rare (but not exponentially rare) large-angle deflections of partons within a jet produced in a heavy ion collision, or of such a jet itself, experimentalists can find the weakly coupled short-distance quark and gluon particles (scatterers) within the strongly coupled liquid quark-gluon plasma (QGP) produced in heavy ion collisions. This is the closest one can come to probing QGP via a scattering experiment and hence is the best available path toward learning how a strongly coupled liquid emerges from an asymptotically free gauge theory. The short-distance, particulate, structure of liquid QGP can be revealed in events in which a jet parton resolves, and scatters off, a parton from the droplet of QGP. The probability for picking up significant transverse momentum via a single scattering was calculated previously, but only in the limit of infinite parton energy which means zero angle scattering. Here, we provide a leading order perturbative QCD calculation of the Molière scattering probability for incident partons with finite energy, scattering at a large angle. We set up a thought experiment in which an incident parton with a finite energy scatters off a parton constituent within a “brick” of QGP, which we treat as if it were weakly coupled, as appropriate for scattering with large momentum transfer, and compute the probability for a parton to show up at a nonzero angle with some energy. We include all relevant channels, including those in which the parton that shows up at a large angle was kicked out of the medium as well as the Rutherford-like channel in which what is seen is the scattered incident parton. The results that we obtain will serve as inputs to future jet Monte Carlo calculations and can provide qualitative guidance for how to use future precise, high statistics, suitably differential measurements of jet modification in heavy ion collisions to find the scatterers within the QGP liquid.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Gluon transverse-momentum-dependent distributions from large-momentum effective theory

We demonstrate that gluon transverse-momentum-dependent parton distribution functions (TMDPDFs) can be extracted from lattice calculations of appropriate Euclidean correlations in large-momentum effective theory (LaMET). Based on perturbative calculations of gluon unpolarized and helicity TMDPDFs, we present a matching formula connecting them and their LaMET counterparts, where the latter are renormalized in a scheme facilitating lattice calculations and converted to the $\overline{MS}$ scheme. The hard matching kernel is given up to one-loop level. We also show that the perturbative result is independent of the prescription used for the pinch-pole singularity in the relevant correlations. Our results offer a guidance for the extraction of gluon TMDPDFs from lattice simulations, and have the potential to greatly facilitate perturbative calculations of the hard matching kernel.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Non-linear dynamics of jet quenching

We develop a comprehensive analytic framework for jet quenching in QCD media, based on a medium-induced parton cascade sourced by collinear virtual splittings. We show that the energy flow out of the jet cone, driven by turbulent gluon cascades, is governed by a non-linear rate equation that resums gluon splittings at arbitrary angles and is enhanced by the medium length, L. The solution of this equation sets the initial condition for a non-linear DGLAP-like evolution equation, which describes the collinear early vacuum cascade resolved by the medium at angles exceeding the medium resolution angle, θ c . For asymptotic jet energies, the medium-induced cascade displays an exponential behavior that generalizes the Poisson-like distribution of parton energy loss. This formulation enables the resummation of leading contributions in α s ln(1/R), and α s ln(R/θ c ), and powers of α s L. We briefly explore the limit of strong quenching, where analytic treatments are feasible, offering insights into the impact of parton cascades on jet quenching. These results provide guidance for future numerical simulations and analytical investigations.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Measurements of the groomed and ungroomed jet angularities in pp collisions at $ \sqrt{s}$ = 5.02 TeV

The jet angularities are a class of jet substructure observables which characterize the angular and momentum distribution of particles within jets. These observables are sensitive to momentum scales ranging from perturbative hard scatterings to nonperturbative fragmentation into final-state hadrons. We report measurements of several groomed and ungroomed jet angularities in pp collisions at $\sqrt{s}$ = 5.02 TeV with the ALICE detector. Jets are reconstructed using charged particle tracks at midrapidity (|η| < 0.9). The anti-$k_T$ algorithm is used with jet resolution parameters R = 0.2 and R = 0.4 for several transverse momentum $p^{ch jet}_{T}$ intervals in the 20–100 GeV/c range. Using the jet grooming algorithm Soft Drop, the sensitivity to softer, wide-angle processes, as well as the underlying event, can be reduced in a way which is well-controlled in theoretical calculations. We report the ungroomed jet angularities, λ α , and groomed jet angularities, λ α,g , to investigate the interplay between perturbative and nonperturbative effects at low jet momenta. Various angular exponent parameters α = 1, 1.5, 2, and 3 are used to systematically vary the sensitivity of the observable to collinear and soft radiation. Results are compared to analytical predictions at next-to-leading-logarithmic accuracy, which provide a generally good description of the data in the perturbative regime but exhibit discrepancies in the nonperturbative regime. Moreover, these measurements serve as a baseline for future ones in heavy-ion collisions by providing new insight into the interplay between perturbative and nonperturbative effects in the angular and momentum substructure of jets. They supply crucial guidance on the selection of jet resolution parameter, jet transverse momentum, and angular scaling variable for jet quenching studies.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Indirect percutaneous core needle biopsy of solid pancreatic or peripancreatic lesions

Solid pancreatic or peripancreatic lesions comprise a heterogeneous group of diseases that rely on a multimodality imaging approach for subsequent tissue procurement. Endoscopic ultrasound (EUS)-guided fine needle aspiration (FNA)/biopsy is an effective and safe method for tissue diagnosis in this region. The failure to obtain adequate tissue for diagnosis under EUS guidance is still a rare but important issue. Percutaneous core needle biopsy (CNB) provides an alternative pathway for adequate specimen acquisition. Because of the deep retroperitoneal location, the percutaneous biopsy of pancreatic or peripancreatic lesions may inevitably pass through visceral organs. The procedure is relatively risky and difficult for general radiologists, particularly beginners, and an adequate knowledge of the abdominal anatomy and biopsy technique is indispensable. In this review, various aspects of percutaneous CNB for solid pancreatic or peripancreatic lesions using different trans-organ approaches are reviewed to increase the chance of successful biopsy.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Magnetic Resonance Imaging-Guided Osseous Biopsy in Children With Chronic Recurrent Multifocal Osteomyelitis

Purpose: To report the safety and diagnostic performance of magnetic resonance (MRI)-guided core biopsy of osseous lesions in children with chronic recurrent multifocal osteomyelitis (CRMO) that were visible on MRI but were occult on radiography and computed tomography (CT). Materials and Methods: A retrospective analysis of MRI-guided osseous biopsy performed in seven children (four girls and three boys; mean age 13 years (range 11 to 14) with CRMO was performed. Indication for using MRI guidance was visibility of lesions by MRI only. MRI-guided procedures were performed with 0.2-Tesla (Magnetom Concerto; Siemens, Erlangen, Germany; n = 5) or 1.5-T (Magnetom Espree; Siemens; n = 2) open MRI systems. Core needle biopsy was obtained using an MRI-compatible 4-mm drill system. Conscious sedation or general anesthesia was used. Parameters evaluated were lesion visibility, technical success, procedure time, complications and microbiology, cytology, and histopathology findings. Results: Seven of seven (100%) targeted lesions were successfully visualized and sampled. All obtained specimens were sufficient for histopathological analysis. Length of time of the procedures was 77 min (range 64 to 107). No complications occurred. Histopathology showed no evidence of malignancy, which was confirmed at mean follow-up of 50 months (range 28 to 78). Chronic nonspecific inflammation characteristic for CRMO was present in four of seven (58%) patients, and edema with no inflammatory cells was found in three of seven (42%) patients. There was no evidence of infection in any patient. Conclusion: MRI-guided osseous biopsy is a safe and accurate technique for the diagnosis of pediatric CRMO lesions that are visible on MRI only.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Percutaneous Irreversible Electroporation Lung Ablation: Preliminary Results in a Porcine Model

Objective: Irreversible electroporation (IRE) uses direct electrical pulses to create permanent 'pores' in cell membranes to cause cell death. In contrast to conventional modalities, IRE has a nonthermal mechanism of action. Our objective was to study the histopathological and imaging features of IRE in normal swine lung. Materials and Methods: Eleven female swine were studied for hyperacute (8 h), acute (24 h), subacute (96 h), and chronic (3 week) effects of IRE ablation in lung. Paired unipolar IRE applicators were placed under computed tomography (CT) guidance. Some applicators were deliberately positioned near bronchovascular structures. IRE pulse delivery was synchronized with the cardiac rhythm only when ablation was performed within 2 cm of the heart. Contrast-enhanced CT scan was performed immediately before and after IRE and at 1 and 3 weeks after IRE ablation. Representative tissue was stained with hematoxylin and eosin for histopathology. Results: Twenty-five ablations were created: ten hyperacute, four acute, and three subacute ablations showed alveolar edema and necrosis with necrosis of bronchial, bronchiolar, and vascular epithelium. Bronchovascular architecture was maintained. Chronic ablations showed bronchiolitis obliterans and alveolar interstitial fibrosis. Immediate post-procedure CT images showed linear or patchy density along the applicator tract. At 1 week, there was consolidation that resolved partially or completely by 3 weeks. Pneumothorax requiring chest tube developed in two animals; no significant cardiac arrhythmias were noted. Conclusion: Our preliminary porcine study demonstrates the nonthermal and extracellular matrix sparing mechanism of action of IRE. IRE is a potential alternative to thermal ablative modalities.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

An Approach for Preoperative Planning and Performance of MR-guided Interventions Demonstrated With a Manual Manipulator in a 1.5T MRI Scanner

Purpose: The aim of this work was to develop and test a general methodology for the planning and performance of robot-assisted, MR-guided interventions. This methodology also includes the employment of software tools with appropriately tailored routines to effectively exploit the capabilities of MRI and address the relevant spatial limitations. Methods: The described methodology consists of: (1) patient-customized feasibility study that focuses on the geometric limitations imposed by the gantry, the robotic hardware, and interventional tools, as well as the patient; (2) stereotactic preoperative planning for initial positioning of the manipulator and alignment of its end-effector with a selected target; and (3) real-time, intraoperative tool tracking and monitoring of the actual intervention execution. Testing was performed inside a standard 1.5T MRI scanner in which the MR-compatible manipulator is deployed to provide the required access. Results: A volunteer imaging study demonstrates the application of the feasibility stage. A phantom study on needle targeting is also presented, demonstrating the applicability and effectiveness of the proposed preoperative and intraoperative stages of the methodology. For this purpose, a manually actuated, MR-compatible robotic manipulation system was used to accurately acquire a prescribed target through alternative approaching paths. Conclusions: The methodology presented and experimentally examined allows the effective performance of MR-guided interventions. It is suitable for, but not restricted to, needle-targeting applications assisted by a robotic manipulation system, which can be deployed inside a cylindrical scanner to provide the required access to the patient facilitating real-time guidance and monitoring.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Single-Session Radiofrequency Ablation of Bilateral Lung Metastases

Purpose: This retrospective study examined the feasibility and efficacy of bilateral lung radiofrequency ablation (RFA) performed in a single session. Methods: From 2002-2009, patients with bilateral lung metastases were treated by RFA, where possible in a single session under general anesthesia with CT guidance. The second lung was punctured only if no complications occurred after treatment of the first lung. Five lung metastases maximum per patient were treated by RFA and prospectively followed. The primary endpoint was the evaluation of acute and delayed complications. Secondary endpoints were calculation of hospitalization duration, local efficacy, median survival, and median time to tumor progression. Local efficacy was evaluated on CT or positron emission tomography (PET) CT. Results: Sixty-seven patients were treated for bilateral lung metastases with RFA (mean age, 62 years). Single-session treatment was not possible in 40 due to severe pneumothoraces (n = 24), bilateral pleural contact (n = 14), and operational exclusions (n = 2). Twenty-seven (41%) received single-session RFA of lesions in both lungs for 66 metastases overall. Fourteen unilateral and four bilateral pneumothoraces occurred (18 overall, 66.7%). Unilateral (n = 13) and bilateral (n = 2) chest tube drainage was required. Median hospitalization was 3 (range, 2-8) days. Median survival was 26 months (95% confidence interval (CI), 19-33). Four recurrences on RFA sites were observed (4 patients). Median time to tumor progression was 9.5 months (95% CI, 4.2-23.5). Conclusions: Although performing single-session bilateral lung RFA is not always possible due to pneumothoraces after RFA of first lung, when it is performed, this technique is safe and effective.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Comparison of Survival Rate in Primary Non-Small-Cell Lung Cancer Among Elderly Patients Treated With Radiofrequency Ablation, Surgery, or Chemotherapy

Purpose: We retrospectively compared the survival rate in patients with non-small-cell lung cancer (NSCLC) treated with radiofrequency ablation (RFA), surgery, or chemotherapy according to lung cancer staging. Materials and Methods: From 2000 to 2004, 77 NSCLC patients, all of whom had WHO performance status 0-2 and were >60 years old, were enrolled in a cancer registry and retrospectively evaluated. RFA was performed on patients who had medical contraindications to surgery/unsuitability for surgery, such as advanced lung cancer or refusal of surgery. In the RFA group, 40 patients with inoperable NSCLC underwent RFA under computed tomography (CT) guidance. These included 16 patients with stage I to II cancer and 24 patients with stage III to IV cancer who underwent RFA in an adjuvant setting. In the comparison group (n = 37), 13 patients with stage I to II cancer underwent surgery; 18 patients with stage III to IV cancer underwent chemotherapy; and 6 patients with stage III to IV cancer were not actively treated. The survival curves for RFA, surgery, and chemotherapy in these patients were calculated using Kaplan-Meier method. Results: Median survival times for patients treated with (1) surgery alone and (2) RFA alone for stage I to II lung cancer were 33.8 and 28.2 months, respectively (P = 0.426). Median survival times for patients treated with (1) chemotherapy alone and (2) RFA with chemotherapy for stage III to IV cancer were 29 and 42 months, respectively (P = 0.03). Conclusion: RFA can be used as an alternative treatment to surgery for older NSCLC patients with stage I to II inoperable cancer and can play a role as adjuvant therapy with chemotherapy for patients with stage III to IV lung cancer.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Image-Based Monitoring of Magnetic Resonance-Guided Thermoablative Therapies for Liver Tumors

Minimally invasive treatment options for liver tumor therapy have been increasingly used during the last decade because their benefit has been proven for primary and inoperable secondary liver tumors. Among these, radiofrequency ablation has gained widespread consideration. Optimal image-guidance offers precise anatomical information, helps to position interventional devices, and allows for differentiation between already-treated and remaining tumor tissue. Patient safety and complete ablation of the entire tumor are the overriding objectives of tumor ablation. These may be achieved most elegantly with magnetic resonance (MR)-guided therapy, where monitoring can be performed based on precise soft-tissue imaging and additional components, such as diffusion-weighted imaging and temperature mapping. New MR scanner types and newly developed sequence techniques have enabled MR-guided intervention to move beyond the experimental phase. This article reviews the current role of MR imaging in guiding radiofrequency ablation. Signal characteristics of primary and secondary liver tumors are identified, and signal alteration during therapy is described. Diffusion-weighted imaging (DWI) and temperature mapping as special components of MR therapy monitoring are introduced. Practical information concerning coils, sequence selection, and parameters, as well as sequence gating, is given. In addition, sources of artifacts are identified and techniques to decrease them are introduced, and the characteristic signs of residual tumor in T1-, T2-, and DWI are described. We hope to enable the reader to choose MR sequences that allow optimal therapy monitoring depending on the initial signal characteristics of the tumor as well as its size and location in the liver.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Thrombin Injection Failure with Subsequent Successful Stent-Graft Placement for the Treatment of an Extracranial Internal Carotid Pseudoaneurysm in a 5-Year-Old Child

Internal carotid artery pseudoaneurysm is a rare life-threatening condition that may develop in different clinical situations. We report the case of an extracranial internal carotid artery pseudoaneurysm secondary to a throat infection in a pediatric patient that was initially treated with percutaneous thrombin injection under ultrasound guidance. However, recanalization occurred at 48 h, and definitive treatment was then performed by endovascular stent-graft placement. We briefly review the clinical characteristics of this uncommon clinical condition as well as the treatment options.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Venous Access Ports: Indications, Implantation Technique, Follow-Up, and Complications

The subcutaneous venous access device (SVAD or 'port') is a critical component in the care of patients with chronic disease. The modern SVAD provides reliable access for blood withdrawal and medication administration with minimal disruption to a patient's lifestyle. Because of improved materials and catheter technology, today's ports are lighter and stronger and capable of high-pressure injections of contrast for cross-sectional imaging. The majority of SVAD placement occurs in interventional radiology departments due to their ability to provide this service at lower costs, lower, complication rates, and greater volumes. Port-insertion techniques vary depending on the operator, but all consist of catheter placement in the central venous circulation followed by subcutaneous pocket creation and port attachment to the catheter with fixation and closure of the pocket. Venous access challenges occasionally occur in patients with central vein occlusions, necessitating catheterization of collateral veins or port placement in alternate locations. Complications of SVADs include those associated with the procedure as well as short- (<30 days) and long-term problems. Procedural and early complications are quite rare due to the near-universal use of real-time ultrasound guidance for vein puncture, but they can include hematoma, catheter malposition, arrhythmias, and pneumothorax. Late problems include both thrombotic complications (native venous or port-catheter thrombosis) and infections (tunnel or pocket infections or catheter-associated bloodstream infections). Most guidelines suggest that 0.3 infections/1000 catheter days is an appropriate upper threshold for the insertion of SVADs.

62 RADIOLOGY AND NUCLEAR MEDICINE↗