Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “GAMMA FUNCTION”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,153 records · Page 64

Ab initio response functions for Cherenkov-based neutron detectors

Neutron time-of-flight diagnostics at the NIF were of late outfitted with Cherenkov detectors. A fused silica radiator delivers sub-nanosecond response time and is optically coupled to a microchannel plate photomultiplier tube with gain from ~1 to 10 4 . Capitalizing on fast time response and gamma-ray sensitivity, these systems can provide better than 30 ps precision for measuring first moments of neutron distributions. Generation of ab initio instrument response functions (IRFs) is critical to meet the <1% uncertainty needed. A combination of Monte Carlo modeling, benchtop characterization, and in situ comparison is employed. Close agreement is shown between the modeled IRFs and in situ measurements using the NIF’s short-pulse advanced radiographic capability beams. First and second moments of neutron spectra calculated using ab initio IRFs agree well with established scintillator measurements. Next-step designs offer increased sensitivity and time-response.

47 OTHER INSTRUMENTATION↗

Zero-dimensional Cs 4 EuX 6 (X = Br, I) all-inorganic perovskite single crystals for gamma-ray spectroscopy

Organic–inorganic and all-inorganic halide perovskites have become leading candidates toward high-performance optoelectronic devices and radiation detectors. In this work, we report novel zero-dimensional Cs 4 EuX 6 (X = Br, I) perovskite single crystals as self-activated scintillators with superior performance for gamma-ray spectroscopy. Both Cs 4 EuBr 6 and Cs 4 EuI 6 single crystals grown by the Bridgman method were determined to have the trigonal crystal structure with the R$\bar{3}$c space group, and have a melting point of approximately 540°C. Cs 4 EuBr 6 and Cs4EuI 6 exhibit blue emission under UV excitation and high light yields of 78,000 ± 4000 photons/MeV and 53,000 ± 3000 photons/MeV under 137 Cs gamma-ray irradiation, respectively. In particular, the former represents the best result achieved for self-activated scintillators thus far. Thermally stimulated luminescence studies and density functional theory calculations elucidate the correlation between halogen vacancies and long-lived emission (afterglow) at room temperature in Cs4EuX 6 (X=Br, I) single crystals. In conclusion, our findings not only demonstrate the high gamma-ray detection efficiency in Cs 4 EuX 6 (X=Br, I), but will further promote the development of 0D metal halide-based novel luminescent and radiation detection materials.

36 MATERIALS SCIENCE↗

On microscopic theory of radiative nuclear reaction characteristics

A survey of some results in the modern microscopic theory of properties of nuclear reactions with gamma rays is given. First of all, we discuss the impact of Phonon Coupling (PC) on the Photon Strength Function (PSF) because it represents the most natural physical source of additional strength found for Sn isotopes in recent experiments that could not be explained within the standard HFB + QRPA approach. The self-consistent version of the Extended Theory of Finite Fermi Systems in the Quasiparticle Time Blocking Approximation is applied. It uses the HFB mean field and includes both the QRPA and PC effects on the basis of the SLy4 Skyrme force. With our microscopic E1 PSFs, the following properties have been calculated for many stable and unstable even–even semi-magic Sn and Ni isotopes as well as for double-magic {sup 132}Sn and {sup 208}Pb using the reaction codes EMPIRE and TALYS with several Nuclear Level Density (NLD) models: (1) the neutron capture cross sections; (2) the corresponding neutron capture gamma spectra; (3) the average radiative widths of neutron resonances. In all the properties considered, the PC contribution turned out to be significant, as compared with the standard QRPA one, and necessary to explain the available experimental data. The results with the phenomenological so-called generalized superfluid NLD model turned out to be worse, on the whole, than those obtained with the microscopic HFB + combinatorial NLD model. The very topical question about the M1 resonance contribution to PSFs is also discussed.Finally, we also discuss the modern microscopic NLD models based on the self-consistent HFB method and show their relevance to explain the experimental data as compared with the phenomenological models. The use of these self-consistent microscopic approaches is of particular relevance for nuclear astrophysics, but also for the study of double-magic nuclei.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Confirmation of the E(sup src)(sub Peak)-E(sub iso) (Amati) relation from the x-ray flash XRF 050416A observed by the Swift burst alert telescope

We report Swift Burst Alert Telescope (BAT) observations of the X-ray flash (XRF) XRF 050416A. The fluence ratio between the 15-25 and 25-50 keV energy bands of this event is 1.5, thus making it the softest gamma-ray burst (GRB) observed by BAT so far. The spectrum is well fitted by a Band function with E(sup obs)(sub peak) of 15.0(sup +2.3)(sub -2.7) keV. Assuming the redshift of the host galaxy (z = 0.6535), the isotropic equivalent radiated energy E(sub iso) and the peak energy at the GRB rest frame (E(sup src)(sub peak)) of XRF 050416A are not only consistent with the correlation found by Amati et al. and extended to XRFs by Sakamoto et al. but also fill in the gap of this relation around the 30-80 keV range of E(sup src)(sub peak). This result tightens the validity of the E(sup src)(sub Peak)-E(sup src)(sub peak) relation from XRFs to GRBs. We also find that the jet break time estimated using the empirical relation between E(sup src)(sub peak) and the collimation corrected energy E(sub gamma), is inconsistent with the afterglow observation by the Swift X-Ray Telescope. This could be due to the extra external shock emission overlaid around the jet break time or to the nonexistence of a jet break feature for XRFs, which might be a further challenge for GRB jet emission models and XRF/GRB unification scenarios.

Sakamoti, T.↗

Smooth Optical Self-similar Emission of Gamma-Ray Bursts

We offer a new type of calibration for gamma-ray bursts (GRB), in which some class of GRB can be marked and share a common behavior. We name this behavior Smooth Optical Self-similar Emission (SOS-similar Emission) and identify this subclasses of GRBs with optical light curves described by a universal scaling function.

79 ASTRONOMY AND ASTROPHYSICS↗

Test of the statistical model in {sup 96}Mo with the BaF{sub 2}{gamma} calorimeter DANCE array

The {gamma}-ray cascades following the {sup 95}Mo(n,{gamma}){sup 96}Mo reaction were studied with the {gamma} calorimeter DANCE (Detector for Advanced Neutron Capture Experiments) consisting of 160 BaF{sub 2} scintillation detectors at the Los Alamos Neutron Science Center. The {gamma}-ray energy spectra for different multiplicities were measured for s- and p-wave resonances below 2 keV. The shapes of these spectra were found to be in very good agreement with simulations using the DICEBOX statistical model code. The relevant model parameters used for the level density and photon strength functions were identical with those that provided the best fit of the data from a recent measurement of the thermal {sup 95}Mo(n,{gamma}){sup 96}Mo reaction with the two-step-cascade method. The reported results strongly suggest that the extreme statistical model works very well in the mass region near A=100.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

WE-EF-303-03: A New Aperture-Based Imaging System for Prompt-Gamma Range Verification of Proton Beam Therapy

Purpose: To develop and characterize a novel aperture-based imaging system for high-energy gamma-rays. This collimated system will provide 2-dimensional imaging capability for verification of proton beam range and Bragg peak dose via prompt-gamma detection. Methods: A multi-knife-edge slit collimator has been designed, constructed, and characterized via simulations and experimental measurements. The 20×20×7.5 cm{sup 3} tungsten collimator and accompanying LSO scintillation detector were simulated using the TOPAS Geant4 -based Monte Carlo package. Iterative reconstruction methods were combined with point response functions to characterize the imaging performance of the system. The response of the system has begun to be characterized experimentally as well, using 2.6 MeV gamma-rays from Th-228. Results: Both simulation and experimental results indicate that this collimated system provides 2-D imaging capability in the energy range of interest for prompt-gamma dose verification. In the current configuration, with collimator to source distance of 13 cm, image reconstruction of point sources resulted in spatial resolution (FWHM) of approximately 4 mm in both x-and y-directions in the imaging plane. The accuracy of positioning the point sources is less than 1 mm. Conclusion: This work has characterized, via simulation and measurements, a novel multi-knife-edge slit collimator in front of a more conventional position-sensitive LSO scintillator detector. The multi-slit pattern is designed to increase detection efficiency and provide spatial information in 2-dimensions -- an improvement over a single-slit collimator design. The thickness and density of the collimator will allow this detection system to perform well in an environment with high gamma flux, while ultimately providing peak determination accuracy on the order of 1 mm. This material is based upon work supported by the Department of Energy National Nuclear Security Administration under Award Number: DE-NA0000979 through the Nuclear Science and Security Consortium.

60 APPLIED LIFE SCIENCES↗

Magnetic Microcalorimeter Gamma-Detectors for High-Accuracy Nuclear Decay Data

Magnetic microcalorimeters (MMCs) are low-energy gamma-ray detectors with ultra-high energy resolution that are operated at temperatures below 50 mK. They use metallic Au absorbers and paramagnetic Ag:Er sensors to measure gamma-ray energies from an increase in detector temperature. Ultra-low temperatures are made accessible to non-expert users with “dry” dilution refrigerators that replace the traditional liquid N 2 and He pre-cooling with a mechanically cooled pulse-tube refrigerator. Our MMC gamma detectors have achieved an energy resolution below 40 eV FWHM at 60 keV, and they have a uniform and reproducible response function that allows adding spectra from different detector pixels without loss in energy resolution. These properties make MMCs well-suited to re-measure nuclear decay data with increased precision and smaller systematic errors to increase the accuracy of non-destructive assays (NDA). We present recent MMC gamma-ray spectra of Th-234 to show how MMCs can resolve lines that are relevant for NDA analysis and that overlap in Ge spectra. We also discuss the accuracy that MMCs can achieve for nuclear decay data with an emphasis on gamma-ray energies and intensity ratios that current NDA codes are based on.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Direct cross section measurement of 102 Pd ⁢(𝛾,𝑝) and 102 Pd ⁢(𝛾,𝛼) for the astrophysical 𝑝 process

Background: A handful of neutron-deficient stable nuclei, known as the “p nuclei,” cannot be produced through astrophysical neutron capture processes. Instead, some of these nuclei are proposed to be produced by 𝛾-induced reactions on existing r- and s-process seeds. The specific astrophysical site or sites are not yet identified, however, with uncertainties in the cross sections of these 𝛾-induced reactions playing a role. Databases of reaction rates for astrophysical simulations often rely on theoretical statistical model calculations, such as Hauser-Feshbach, for rates where no experimental information is known. However, reasonable variations in the choice of parametrizations of various nuclear properties can create order-of-magnitude variations in the final predicted cross sections and reaction rates, which are then propagated through the models to the predicted final abundances. Purpose: To better constrain these statistical model calculations and ultimately reduce the uncertainties from the nuclear physics on our understanding of the p nuclei, a measurement of the cross sections of 𝛾-induced reactions on the p-nucleus 102 Pd was undertaken. This work represents the first measurement of its kind, using segmented silicon detectors to measure prompt charged particle emission from 𝛾-induced reactions. Methods: Quasimonoenergetic gamma beams from the High Intensity 𝛾 Source facility bombarded an enriched 102 Pd target. A segmented silicon array was arranged to detect the particles emitted from (𝛾,𝑝) and (𝛾,𝛼) reactions. Results: Reaction cross sections were deduced at multiple 𝛾-beam energies between 10 and 19 MeV, and compared to statistical model calculations using talys-1.96. The 102 Pd ⁢(𝛾,𝑝)⁢ 101 Rh reaction cross section was reasonably well reproduced by a subset of photon strength functions and level densities, though the strength to the ground state of 101 Rh was underestimated at higher incident gamma energies. The 102 Pd ⁢(𝛾,𝛼)⁢ 98 Ru was in general overpredicted by the various alpha-nucleus optical model potentials. Conclusions: While the theoretical cross sections used to model the (𝛾,𝑝) reactions for the p process may be reasonable, a more careful approach is needed in the case of (𝛾,𝛼). Further work to probe gamma-induced reaction cross sections at and near the p nuclei is warranted.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Photolysis of n-butyl nitrite and isoamyl nitrite at 355 nm: A time-resolved Fourier transform infrared emission spectroscopy and ab initio study

We report on the photodissociation dynamics study of n-butyl nitrite and isoamyl nitrite by means of time-resolved Fourier transform infrared (TR-FTIR) emission spectroscopy. The obtained TR-FTIR emission spectra of the nascent NO fragments produced in the 355 nm laser photolysis of the two alkyl nitrite species showed an almost identical rotational temperature and vibrational distributions of NO. In addition, a close resemblance between the two species was also found in the measured temporal profiles of the IR emission of NO and the recorded UV absorption spectra. The experimental results are consistent with our ab initio calculations using the time-dependent density functional theory at the B3LYP/6-311G(d,p) level, which indicate that the substitution of one of the two {gamma}-H atoms in n-C{sub 4}H{sub 9}ONO with a methyl group to form (CH{sub 3}){sub 2}C{sub 3}H{sub 5}ONO has only a minor effect on the photodissociation dynamics of the two molecules.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Nifedipine, a calcium channel blocker, inhibits advanced glycation end product (AGE)-elicited mesangial cell damage by suppressing AGE receptor (RAGE) expression via peroxisome proliferator-activated receptor-gamma activation

The interaction between advanced glycation end products (AGE) and their receptor RAGE mediates the progressive alteration in renal architecture and loss of renal function in diabetic nephropathy. Oxidative stress generation and inflammation also play a central role in diabetic nephropathy. This study investigated whether and how nifedipine, a calcium channel blocker (CCB), blocked the AGE-elicited mesangial cell damage in vitro. Nifedipine, but not amlodipine, a control CCB, down-regulated RAGE mRNA levels and subsequently reduced reactive oxygen species (ROS) generation in AGE-exposed mesangial cells. AGE increased mRNA levels of vascular cell adhesion molecule-1 (VCAM-1) and induced monocyte chemoattractant protein-1 (MCP-1) production in mesangial cells, both of which were prevented by the treatment with nifedipine, but not amlodipine. The beneficial effects of nifedipine on AGE-exposed mesangial cells were blocked by the simultaneous treatment of GW9662, an inhibitor of peroxisome proliferator-activated receptor-{gamma} (PPAR-{gamma}). Although nifedipine did not affect expression levels of PPAR-{gamma}, it increased the PPAR-{gamma} transcriptional activity in mesangial cells. Our present study provides a unique beneficial aspect of nifedipine on diabetic nephropathy; it could work as an anti-inflammatory agent against AGE by suppressing RAGE expression in cultured mesangial cells via PPAR-{gamma} activation.

60 APPLIED LIFE SCIENCES↗

GAMMA-RAY LIGHT CURVES AND VARIABILITY OF BRIGHT FERMI-DETECTED BLAZARS

This paper presents light curves as well as the first systematic characterization of variability of the 106 objects in the high-confidence Fermi Large Area Telescope Bright AGN Sample (LBAS). Weekly light curves of this sample, obtained during the first 11 months of the Fermi survey (2008 August 4-2009 July 4), are tested for variability and their properties are quantified through autocorrelation function and structure function analysis. For the brightest sources, 3 or 4 day binned light curves are extracted in order to determine power density spectra (PDSs) and to fit the temporal structure of major flares. More than 50% of the sources are found to be variable with high significance, where high states do not exceed 1/4 of the total observation range. Variation amplitudes are larger for flat spectrum radio quasars and low/intermediate synchrotron frequency peaked BL Lac objects. Autocorrelation timescales derived from weekly light curves vary from four to a dozen of weeks. Variable sources of the sample have weekly and 3-4 day bin light curves that can be described by 1/f {sup {alpha}} PDS, and show two kinds of gamma-ray variability: (1) rather constant baseline with sporadic flaring activity characterized by flatter PDS slopes resembling flickering and red noise with occasional intermittence and (2)-measured for a few blazars showing strong activity-complex and structured temporal profiles characterized by long-term memory and steeper PDS slopes, reflecting a random walk underlying mechanism. The average slope of the PDS of the brightest 22 FSRQs and of the 6 brightest BL Lacs is 1.5 and 1.7, respectively. The study of temporal profiles of well-resolved flares observed in the 10 brightest LBAS sources shows that they generally have symmetric profiles and that their total duration vary between 10 and 100 days. Results presented here can assist in source class recognition for unidentified sources and can serve as reference for more detailed analysis of the brightest gamma-ray blazars.

79 ASTRONOMY AND ASTROPHYSICS↗

Anisotropic detector system for the measurement of gamma-ray source position

Detection efficiencies of cylindrical detectors for various gamma ray photon angular distributions in the energy range from .10 MeV to 15 MeV are studied. It was found that a properly chosen cylindrical crystal can produce a significantly modulated count rate as a function of angle when rotated in the anisotropic flux, The studies further indicate that simple detector systems can be used on small satellites for the determination of a gamma ray source position. Results are outlined and extended to examine source resolution angles for a practical size detector.

Trombka, J. I.↗

Structural, electronic and optical properties of orthorhombic CdGeO{sub 3} from first principles calculations

Orthorhombic perovskite CdGeO{sub 3} was studied using the density-functional theory (DFT) formalism. The electronic band structure, density of states, effective masses, dielectric function and optical absorption were obtained. Comparing with orthorhombic CaGeO{sub 3}, which is an indirect S->GAMMA gap material, the substitution of calcium by cadmium changes the valence band maximum from the S point to the GAMMA point in reciprocal space, and decreases the Kohn-Sham band gap energy. Our results suggest that orthorhombic CdGeO{sub 3} has features of a semiconductor and is potentially useful for optoelectronic applications. - Abstract: Graphical Abstract Legend (TOC Figure): Different views of the unit cell of orthorhombic CdGeO{sub 3} (left, top). The electronic band structure near the main gap and the partial density of states (PDOS) are shown also (right), as well as the optical absorption for different polarizations of incident light (left, bottom).

36 MATERIALS SCIENCE↗

TRIPOLI-4{sup R} version 9 Shielding for the Shielding Community: Overview, Relevant Benchmarking for Shielding and Licensing Policy - Paper 49

This is a review paper of the Shielding only version of TRIPOLI-4. TRIPOLI-4 and TRIPOLI-4 S: TRIPOLI{sup R} represents a family of radiation transport codes using the Monte Carlo method (1,2). It has been continuously developed at CEA since the mid 60's. TRIPOLI-4{sup R}, being the fourth generation, has been developed starting from the mid 90's in C++. It tracks neutrons from 20 MeV down to 10{sup -5} eV, photons, electrons and positrons from 100 MeV to 1 keV, in 3D arbitrary geometries either in TRIPOLI{sup R} proprietary format or ROOT(4) format. It reads its continuous energy nuclear data from any evaluation in ENDF format, including but not limited to JEFF-3.1.1 and ENDF/BVII.0. It has various simulation modes, fixed-source (with or without fission), criticality, or both of them chained. A variety of tallies are available: averaged flux in a volume (track length and collision estimators), surface flux and current, point flux, reaction rates, deposited energy, dpa, pka, gamma spectroscopy, mesh tallies, tallies for criticality (k{sub eff}, beta eff, kinetic parameters). It provides the user with embedded response functions from IRDF and EAF as well. Several variance reduction techniques (3), including automated ones, make it particularly suitable to deep penetration problems (implicit capture, Russian roulette, exponential biasing with automatic estimation of the importance map). It may run in parallel, on single multi-core machines as well as heterogeneous networks of stations or massively parallel machines. It comes with productivity tools designed to speed-up the elaboration and verification of the input deck as well as the output analysis: 2D interactive display of geometry; 2D display of mesh tallies and collision sites; 3D input deck modeler; compatibility with ROOT tools to post-process TRIPOLI{sup R} outputs. Its V and V test base is made of more than 1000 internationally accepted benchmarks from ICSBEP and SINBAD (REPLICA, ASPIS, NESDIP) and covers all its application domains, including several shielding cases which will be detailed in the talk. TRIPOLI-4{sup R} is the reference Monte Carlo code for CEA, EDF, and also for AREVA for a number of applications. A 'Shielding-only' version has been designed to specifically answer the needs of the shielding community. It is distributed through the NEA Databank with a license for R and D, covering the fusion applications, whose terms are detailed in the paper.

61 RADIATION PROTECTION AND DOSIMETRY↗

An updated analysis of two classes of f(R) theories of gravity

The observed accelerated cosmic expansion can be a signature of fourth-order gravity theories, where the acceleration of the Universe is a consequence of departures from Einstein General Relativity, rather than the sign of the existence of a fluid with negative pressure. In the fourth-order gravity theories, the gravity Lagrangian is described by an analytic function f(R) of the scalar curvature R subject to the demanding conditions that no detectable deviations from standard GR is observed on the Solar System scale. Here we consider two classes of f(R) theories able to pass Solar System tests and investigate their viability on cosmological scales. To this end, we fit the theories to a large dataset including the combined Hubble diagram of Type Ia Supernovae and Gamma Ray Bursts, the Hubble parameter H(z) data from passively evolving red galaxies, Baryon Acoustic Oscillations extracted from the seventh data release of the Sloan Digital Sky Survey (SDSS) and the distance priors from the Wilkinson Microwave Anisotropy Probe seven years (WMAP7) data. We find that both classes of f(R) fit very well this large dataset with the present-day values of the matter density, Hubble constant and deceleration parameter in agreement with previous estimates; however, the strong degeneracy among the f(R) parameters prevents us from strongly constraining their values. We also derive the growth factor g = dln δ/dln a, with δ = δρ{sub M}/ρ{sub M} the matter density perturbation, and show that it can still be well approximated by g(z)∝Ω{sub M}(z){sup γ}. We finally constrain γ (on some representative scales) and investigate its redshift dependence to see whether future data can discriminate between these classes of f(R) theories and standard dark energy models.

79 ASTRONOMY AND ASTROPHYSICS↗

Development of pseudo-random binary gratings and arrays for calibration of surface profile metrology tools

Optical Metrology tools, especially for short wavelength (EUV and X-Ray), must cover a wide range of spatial frequencies from the very low, which affects figure, to the important mid-spatial frequencies and the high spatial frequency range, which produces undesirable flair. A major difficulty in using surface profilometers arises due to the unknown Modulation Transfer Function (MTF) of the instruments. Therefore, accurate calibration of profilometers, the understanding of their MTF limitations, and cross calibration between tools represents a considerable challenge for quantitative optical metrology. In previous work the instrumental MTF of a surface profiler was precisely measured using reference test surfaces based on binary pseudo-random (BPR) gratings. Here, they present results of fabricating and using two-dimensional (2D) BPR arrays that allow for a direct 2D calibration of the instrumental MTF. BPR sequences are widely used in engineering and communication applications such as Global Position System, and wireless communication protocol. The ideal BPR pattern has a flat 'white noise' response over the entire range of spatial frequencies of interest. The BPR array used here is based on the Uniformly Redundant Array prescription initially used for x-ray and gamma ray astronomy applications. The URA's superior imaging capability originates from the fact that its cyclical autocorrelation function very closely approximates a delta function, which produces a flat Power Spectrum Density (PSD). Three different BPR array patterns were fabricated by electron beam lithography and ICP etching of silicon. The basic size unit was 200 nm, 400 nm, and 600 nm. Figure 1 shows the fabrication sequence. The 2D BPR arrays were used as standard test surfaces for MTF calibration of the MicroMap{trademark}-570 interferometric microscope with all available objectives. Figure 2 shows representative scanning probe height data for the 400 nm BPR sample. Figure 2 shows the raw Power Spectral Density for 5 different objectives. They demonstrate that the two dimensional BPR array is a very effective calibration standard. However, departures from ideal, such as square sidewall, and uniform etch depth ultimately can limit the accuracy of the calibration. The effects of fabrication imperfections on the efficiency of calibration will be discussed.

36 MATERIALS SCIENCE↗