Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Fluorescence”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,153 records · Page 64

Chemically sensitive fluorescence imaging of colliding microdroplets

Here, we present a simple optical capability for generating spatially resolved chemical concentration maps of mixing fluids using a chemically sensitive dye, 1-hydroxy-3,6,8-pyrenetrisulfonic acid, detected by planar laser induced fluorescence. To demonstrate an application of this capability, we investigate the collision and mixing of a pair of microdroplets in air. The two microdroplets are composed of different fluids, methanol and water, with the dye initially in the methanol droplet. When the droplets collide and mixing process develops, the fluorescence of the dye shifts from blue to green as the solvent environment changes. A series of spectral-temporal images of the collision and subsequent mixing are recorded, from which we extract the distribution of the two intermixing droplet species reflected in the spatially resolved dye spectra. Images reveal material transfer between droplets in both coalescing and non-coalescing droplet collisions.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Charge transfer as a mechanism for chlorophyll fluorescence concentration quenching

Highly concentrated solutions of chlorophyll display rapid fluorescence quenching. The same devastating energy loss is not seen in photosynthetic light-harvesting antenna complexes, despite the need for chromophores to be in close proximity to facilitate energy transfer. A promising, though unconfirmed mechanism for the observed quenching is energy transfer from an excited chlorophyll monomer to a closely associated chlorophyll pair that subsequently undergoes rapid nonradiative decay to the ground state via a short-lived intermediate charge-transfer state. In this work, we make use of newly emerging fast methods in quantum chemistry to assess the feasibility of this proposed mechanism. We calculate rate constants for the initial charge separation, based on Marcus free-energy surfaces extracted from molecular dynamics simulations of solvated chlorophyll pairs, demonstrating that this pathway will compete with fluorescence (i.e., drive quenching) at experimentally measured quenching concentrations. We show that the rate of charge separation is highly sensitive to interchlorophyll distance and the relative orientations of chromophores within a quenching pair. We discuss possible solvent effects on the rate of charge separation (and consequently the degree of quenching), using the light-harvesting complex II (LH2) protein from rps. acidophila as a specific example of how this process might be controlled in a protein environment. Crucially, we reveal that the LH2 antenna protein prevents quenching, even at the high chlorophyll concentrations required for efficient energy transfer, by restricting the range of orientations that neighboring chlorophyll pairs can adopt.

59 BASIC BIOLOGICAL SCIENCES↗

Spatially resolved charge-transfer kinetics at the quantum dot–microbe interface using fluorescence lifetime imaging microscopy

Integrating the optoelectronic properties of quantum dots (QDs) with biological enzymatic systems to form microbe-semiconductor biohybrids offers promising prospects for both solar-to-chemical conversion and light-modulated biochemical processes. Developing these nano–bio hybrid systems necessitates a deep understanding of charge-transfer dynamics at the nano–bio interface. Photoexcited carrier transfer from QDs to microbes is driven by complex interactions, with emerging insights into the relevant thermodynamic and kinetic factors. The heterogeneities of both microbes and QD ensembles pose significant challenges in mechanistic understanding, which is critical for designing advanced nano–bio hybrids. We used fluorescence lifetime imaging microscopy to analyze charge transfer between a CdSe QD film andShewanella oneidensismicrobes. We correlated the spatiotemporal fluorescence data with an analytical model. Our analysis revealed two distinct distributions of QD de-excitation pathways. The characteristics of these distributions: 1) a faster transfer rate ( k ¯ E T 1 = 1.5 10 9 s - 1 ), with a lower acceptor number ( N ¯ a 1 = 0.03 ) and 2) a slower transfer rate ( k ¯ E T 2 = 4.1 10 8 s - 1 ) with a higher acceptor number ( N ¯ a 2 = 0.18 ). We assign these distributions to the indirect and direct electron transfer mechanisms, respectively. Our findings demonstrate how spectroscopic imaging can uncover fundamental electron transfer mechanisms at complex interfaces, offering valuable design principles for future nano–bio hybrids.

Science & Technology - Other Topics↗

Molecular Dynamics Simulations of Highly Charged Green Fluorescent Proteins

A recent experimental study showed that green fluorescent protein (GFP) that has been mutated to have ultra-high positive or negative net charges, retain their native structure and fluorescent properties while gaining resistance to aggregation under denaturing conditions. These proteins also provide an ideal test case for studying the effects of surface charge on protein structure and dynamics. They have performed classical molecular dynamics (MD) simulations on the near-neutral wildtype GFP and mutants with net charges of -29 and +35. They analyzed the resulting trajectories to quantify differences in structure and dynamics between the three GFPs. This analyses shows that all three proteins are stable over the MD trajectory, with the near-neutral wild type GFP exhibiting somewhat more flexibility than the positive or negative GFP mutants, as measured by the order parameter and changes in phi-psi angles. There are more dramatic differences in the properties of the water and counter ions surrounding the proteins. The water diffusion constant near the protein surface is closer to the value for bulk water in the positively charged GFP than in the other two proteins. Additionally, the positively charged GFP shows a much greater clustering of the counter ions (CL-) near its surface than corresponding counter ions (Na+) near the negatively charged mutant.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

LCLS in—photon out: fluorescence measurement of neon using soft x-rays

Here, we measured the fluorescence photon yield of neon upon soft x-ray ionization (~1200 eV) from the x-ray free-electron laser at Linac Coherent Light Source, and demonstrated the usage of a grazing incidence spectrometer with a variable line spacing grating to perform x-ray fluorescence spectroscopy on a gas phase system. Our measurements also allowed us to estimate the focal size of the beam from the theoretical description developed, in terms of the rate equation approximation accounting for photoionization shake off of neutral neon and double auger decay of single core holes.

74 ATOMIC AND MOLECULAR PHYSICS↗

2D imaging of absolute methyl concentrations in nanosecond pulsed plasma by photo-fragmentation laser-induced fluorescence

The methyl radical plays a central role in plasma-assisted hydrocarbon chemistry but is challenging to detect due to its high reactivity and strongly pre-dissociative electronically excited states. In this work, we report the development of a photo-fragmentation laser-induced fluorescence (PF-LIF) diagnostic for quantitative 2D imaging of methyl profiles in a plasma. This technique provides temporally and spatially resolved measurements of local methyl distributions, including in near-surface regions that are important for plasma-surface interactions such as plasma-assisted catalysis. The technique relies on photo-dissociation of methyl by the fifth harmonic of a Nd:YAG laser at 212.8 nm to produce CH fragments. These photofragments are then detected with LIF imaging by exciting a transition in the B-X(0, 0) band of CH with a second laser at 390 nm. Fluorescence from the overlapping A-X(0, 0), A-X(1, 1), and B-X(0, 1) bands of CH is detected near 430 nm with the A-state populated by collisional B-A electronic energy transfer. This non-resonant detection scheme enables interrogation close to a surface. The PF-LIF diagnostic is calibrated by producing a known amount of methyl through photo-dissociation of acetone vapor in a calibration gas mixture. We demonstrate PF-LIF imaging of methyl production in methane-containing nanosecond pulsed plasmas impinging on dielectric surfaces. Absolute calibration of the diagnostic is demonstrated in a diffuse, plane-to-plane discharge. Measured profiles show a relatively uniform distribution of up to 30 ppm of methyl. Relative methyl measurements in a filamentary plane-to-plane discharge and a plasma jet reveal highly localized intense production of methyl. The utility of the PF-LIF technique is further demonstrated by combining methyl measurements with formaldehyde LIF imaging to capture spatiotemporal correlations between methyl and formaldehyde, which is an important intermediate species in plasma-assisted oxidative coupling of methane.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Fluorescence time profile measurement of LAB based liquid scintillator in response to medium relativistic ion particles

Liquid scintillator is widely used in particle physics experiments due to its high light yield, good timing resolution, scalability and low cost. Certain liquid scintillators exhibit pulse shape discrimination capabilities because of difference in fluorescence timing properties induced by different particles. Its fluoresence timing properties have been measured mostly for radioactive decay sources at MeV energies. Here, we present a novel measurement of fluorescence time properties of Linear Alkyl Benzene (LAB) based liquid scintillator in response to high-energy ions of hydrogen (Z = 1), helium (Z = 2) and krypton at around 200–300 MeV/u for the first time. We compared the results to those from radioactive sources and observed a distinct dE / dX dependence, regardless of the particle type. These findings are essential for physics searches such as the diffuse supernova neutrino background in large liquid scintillator detectors like JUNO, and are also critical towards understanding the underlying scintillation timing mechanism.

Ion identification systems↗

Fluorescent and Bioluminescent Reporter Mouse-Adapted Ebola Viruses Maintain Pathogenicity and Can Be Visualized in Vivo

Abstract Ebola virus (EBOV) causes lethal disease in humans but not in mice. Here, we generated recombinant mouse-adapted (MA) EBOVs, including 1 based on the previously reported serially adapted strain (rMA-EBOV), along with single-reporter rMA-EBOVs expressing either fluorescent (ZsGreen1 [ZsG]) or bioluminescent (nano-luciferase [nLuc]) reporters, and dual-reporter rMA-EBOVs expressing both ZsG and nLuc. No detriment to viral growth in vitro was seen with inclusion of MA-associated mutations or reporter proteins. In CD-1 mice, infection with MA-EBOV, rMA-EBOV, and single-reporter rMA-EBOVs conferred 100% lethality; infection with dual-reporter rMA-EBOV resulted in 73% lethality. Bioluminescent signal from rMA-EBOV expressing nLuc was detected in vivo and ex vivo using the IVIS Spectrum CT. Fluorescent signal from rMA-EBOV expressing ZsG was detected in situ using handheld blue-light transillumination and ex vivo through epi-illumination with the IVIS Spectrum CT. These data support the use of reporter MA-EBOV for studies of Ebola virus in animal disease models.

Immunology↗

X-ray fluorescence mapping of brain tissue reveals the profound extent of trace element dysregulation in stroke pathophysiology

Abstract The brain is a privileged organ with regard to its trace element composition and maintains a robust barrier system to sequester this specialized environment from the rest of the body and the vascular system. Stroke is caused by loss of adequate blood flow to a region of the brain. Without adequate blood flow ischaemic changes begin almost immediately, triggering an ischaemic cascade, characterized by ion dysregulation, loss of function, oxidative damage, cellular degradation, and breakdown of the barrier that helps maintain this environment. Ion dysregulation is a hallmark of stroke pathophysiology and we observe that most elements in the brain are dysregulated after stroke. X-ray fluorescence-based detection of physiological changes in the neurometallome after stroke reveals profound ion dysregulation within the lesion and surrounding tissue. Not only are most elements significantly dysregulated after stroke, but the level of dysregulation cannot be predicted from a cell-level description of dysregulation. X-ray fluorescence imaging reveals that the stroke lesion retains <25% of essential K+ after stroke, but this element is not concomitantly elevated elsewhere in the organ. Moreover, elements like Na+, Ca2+, and Cl− are vastly elevated above levels available in normal brain tissue (>400%, >200%, and >150%, respectively). We hypothesize that weakening of the blood–brain barrier after stroke allows elements to freely diffuse down their concentration gradient so that the stroke lesion is in equilibrium with blood (and the compartments containing brain interstitial fluid and cerebrospinal fluid). The change observed for the neurometallome likely has consequences for the potential to rescue infarcted tissue, but also presents specific targets for treatment.

Biochemistry & Molecular Biology↗

Energy shift of Fe-K fluorescence lines due to low ionization demonstrated with XRISM in Centaurus X-3

The Fe K$\alpha$ fluorescence line at 6.4 keV is a powerful probe of cold matter surrounding X-ray sources and has been widely used in various astrophysical contexts. The X-ray microcalorimeter spectrometer onboard XRISM can measure line shifts with unprecedented precision of ${\sim }$0.2 eV, equivalent to a line-of-sight velocity of ${\sim }$10 km s$^{-1}$. At this level of accuracy, however, several factors that influence the line energy must be carefully considered prior to astrophysical interpretation. One such important factor is the ionization degree, Fe$^{q+}$. The K$\alpha$ line shifts redward by ${\sim }$4 eV as q increases from 0 (neutral) to 8 (Ar-like). Additionally, the accompanying Fe K$\beta$ line at 7.06 keV shifts blueward by ${\sim }$30 eV from $q=0$ to 8. We demonstrate that this effect is actually observable in the XRISM data of the high-mass X-ray binary Centaurus X-3 (Cen X-3). We advocate that the differential energy shift between the K$\alpha$ and K$\beta$ line provides a robust estimate of q by decoupling from other effects that shift the two lines in the same direction. We derived $q \sim 5$ (Sc-like) for the fluorescing matter by comparing the observation with atomic structure calculations of our own and in the literature. By accounting for the derived charge state and the corresponding shift in the rest-frame line energy, we made corrections for this effect and reached a consistent residual shift among the K$\alpha$, K$\beta$, and the optical measurement attributable to the systemic velocity of the system. Consequently, we obtained a new constraint on the location of the cold matter. This ionization effect needs to be assessed in all use cases of the Fe K$\alpha$ line shift beyond Cen X-3, and the proposed metric is generally applicable to all of them.

Astronomy and AstroPhysics↗

Rotational order–disorder structure of fluorescent protein FP480

An analysis of the rotational order–disorder structure of fluorescent protein FP480 is presented. In the last decade, advances in instrumentation and software development have made crystallography a powerful tool in structural biology. Using this method, structural information can now be acquired from pathological crystals that would have been abandoned in earlier times. In this paper, the order–disorder (OD) structure of fluorescent protein FP480 is discussed. The structure is composed of tetramers with 222 symmetry incorporated into the lattice in two different ways, namely rotated 90° with respect to each other around the crystal c axis, with tetramer axes coincident with crystallographic twofold axes. The random distribution of alternatively oriented tetramers in the crystal creates a rotational OD structure with statistically averaged I422 symmetry, although the presence of very weak and diffuse additional reflections suggests that the randomness is only approximate.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Quantification of phosphorus in single cells using synchrotron X-ray fluorescence

Phosphorus is required for numerous cellular compounds and as a result can serve as a useful proxy for total cell biomass in studies of cell elemental composition. Single-cell analysis by synchrotron X-ray fluorescence (SXRF) enables quantitative and qualitative analyses of cell elemental composition with high elemental sensitivity. Element standards are required to convert measured X-ray fluorescence intensities into element concentrations, but few appropriate standards are available, particularly for the biologically important element P. Empirical P conversion factors derived from other elements contained in certified thin-film standards were used to quantify P in the model diatom Thalassiosira pseudonana, and the measured cell quotas were compared with those measured in bulk by spectrophotometry. The mean cellular P quotas quantified with SXRF for cells on Au, Ni and nylon grids using this approach were not significantly different from each other or from those measured spectrophotometrically. Inter-cell variability typical of cell populations was observed. Additionally, the grid substrates were compared for their suitability to P quantification based on the potential for spectral interferences with P. Nylon grids were found to have the lowest background concentrations and limits of detection for P, while background concentrations in Ni and Au grids were 1.8- and 6.3-fold higher. The advantages and disadvantages of each grid type for elemental analysis of individual phytoplankton cells are discussed.

54 ENVIRONMENTAL SCIENCES↗

Fluorescence intensity monitors as intensity and beam-position diagnostics for X-ray free-electron lasers

For LCLS-II, a fluorescence intensity monitor for the non-invasive, pulse-by-pulse normalization of experiments has been developed. A prototype diagnostic was constructed with a microchannel plate assembly and two photodiodes. The diagnostic was then installed in the LCLS SXR instrument Kirkpatrick–Baez mirror chamber with the detectors located above the vertically reflecting mirror. The linearity, noise and position sensitivity of the detectors have been characterized. The photodiode responsivity is suitable for high pulse energies. The microchannel plate detector shows sufficient responsivity over a wide range of pulse energies. The relative signal from the two photodiodes provides a sensitive measure of the X-ray beam position. The fluorescence intensity monitor provides intensity normalization while being compatible with high incident power, a 0.93 MHz repetition rate and ultra-high vacuum.

47 OTHER INSTRUMENTATION↗

Open-source electrochemical cell for in situ X-ray absorption spectroscopy in transmission and fluorescence modes

X-ray spectroscopy is a valuable technique for the study of many materials systems. Characterizing reactions in situ and operando can reveal complex reaction kinetics, which is crucial to understanding active site composition and reaction mechanisms. In this project, the design, fabrication and testing of an open-source and easy-to-fabricate electrochemical cell for in situ electrochemistry compatible with X-ray absorption spectroscopy in both transmission and fluorescence modes are accomplished via windows with large opening angles on both the upstream and downstream sides of the cell. Using a hobbyist computer numerical control machine and free 3D CAD software, anyone can make a reliable electrochemical cell using this design. Onion-like carbon nanoparticles, with a 1:3 iron-to-cobalt ratio, were drop-coated onto carbon paper for testing in situ X-ray absorption spectroscopy. Cyclic voltammetry of the carbon paper showed the expected behavior, with no increased ohmic drop, even in sandwiched cells. Chronoamperometry was used to apply 0.4 V versus reversible hydrogen electrode, with and without 15 min of oxygen purging to ensure that the electrochemical cell does not provide any artefacts due to gas purging. The XANES and EXAFS spectra showed no differences with and without oxygen, as expected at 0.4 V, without any artefacts due to gas purging. The development of this open-source electrochemical cell design allows for improved collection of in situ X-ray absorption spectroscopy data and enables researchers to perform both transmission and fluorescence simultaneously. It additionally addresses key practical considerations including gas purging, reduced ionic resistance and leak prevention.

08 HYDROGEN↗

Escape Ratio Contributes More Than Fluorescence Yield to SIF-GPP Relationship Over Crops and Rainforest

Solar-induced chlorophyll fluorescence (SIF) is an effective indicator to track the gross primary productivity (GPP). However, there is still a lack of a clear understanding for the contribution of physiological and structural factors to the SIF–GPP relationship at the canopy scale. To quantify the influence of different SIF components, particularly the photon escape ratio ($f$ esc ) and fluorescence yield (Φ F ), on the SIF–GPP relationship, this study evaluated the performance of various vegetation indices (VIs), SIF components, light use efficiency (LUE), and GPP over two typical biomes (crops and rainforest), using a range of satellite remote sensing products. In August of each year from 2018 to 2020, both SIF and GPP over United States (U.S.) Corn Belt are higher than those over the Amazon rainforest, attributed to the consistent pattern of higher $f$ esc and LUE over crops than over rainforest, as well as Φ F . Furthermore, the structural signals represented by $f$ esc (R = 0.41–0.64) can better capture the LUE variations than Φ F (R = 0.10–0.30) for each biome. In conclusion, this study highlights that $f$ esc , determined by canopy structure, has great potential to capture LUE and GPP changes within and across biomes.

60 APPLIED LIFE SCIENCES↗

Normalized Solar-Induced Fluorescence Responds Earlier Than Vegetation Indices to the 2019 North China Plain Drought

Recently, solar-induced chlorophyll fluorescence (SIF) from satellites has shown potential for evaluating vegetation status and stress responses. Fluorescence quantum yield ($Φ_F$) is essentially linked to vegetation stress. However, the complex physiological and structural responses of SIF and $Φ_F$ to drought need further study. This study normalized SIF as SIFn to account for angular variations and fluctuations in photosynthetically active radiation (PAR), aiming for more accurate drought monitoring. SIFn anomalies were compared to historical baselines (2019–2021 averages) of vegetation indices (VIs), raw SIF, and $Φ_F$ during a 2019 drought in the North China Plain (NCP). Here, the results show SIFn provides an effective method for drought monitoring, showing the earliest decline compared to raw SIF, VIs, and $Φ_F$. In the first two weeks of drought, SIFn decreased by 8.2%, 7.0%, 12.5%, and 8.2% across the four NCP subdivisions. SIFn outperformed other indicators, proving sensitive to early drought detection. SIFn was also examined for tracking drought alleviation by rainfall. The uncertainty under different viewing geometries was quantified. SIFn anomalies showed a strong correlation with rainfall anomalies (R: 0.45 ~ 0.52) and meteorological factors like PAR (R: 0.80 ~ 0.84) and relative humidity (R:0.52 ~ 0.54). The correlation of near-infrared reflectance (NIRv) and $Φ_F$ anomalies with SIF was weak during drought onset (R: 0.16 ~ 0.32) but strong at the end (R: 0.83 ~ 0.87). These suggest both canopy structure (mainly characterized by NIRv) and vegetation chlorophyll ($Φ_F$) are impacted by drought and influence SIF at different stages.

54 ENVIRONMENTAL SCIENCES↗

Non-Blind Deblurring for Fluorescence: A Deformable Latent Space Approach with Kernel Parameterization

We report N\non-blind deblurring (NBD) is a modeling method of the image deblurring problem in computer vision, where the blurring kernel is known or can be externally estimated. In this paper, we attempt to solve a parametric NBD problem, inspired by the simultaneous acquisition of ptychography and fluorescent imaging (FI). Ptychography is an imaging method that favors larger probes, i.e. convolutional kernels, while FI relies on a small probe for high resolution. Also, the kernel can be solved during ptychographic reconstruction. With Ptycho-FI using the same larger kernel, we can perform NBD on the blurred fluorescent images to achieve high-resolution FI, and thus speed up the experiments. To this end, we design a deep latent space deformation network that is directly parameterized by the kernel. The network consists of three components: encoder, deformer, and decoder, where the deformer is specifically meant to rectify the latent space representations of blurred images to a standard latent space, regardless of the kernel. The deformation network is trained with a two-stage training scheme. We conduct extensive experiments to confirm that our parametric model can adapt to drastically different blurring kernels and perform robust deblurring.

77 NANOSCIENCE AND NANOTECHNOLOGY↗

Focused‐beam X‐ray fluorescence and diffraction microtomographies for mineralogical and chemical characterization of unsectioned extraterrestrial samples

Abstract This study describes the application of new synchrotron X‐ray fluorescence (XRF) and diffraction (XRD) microtomographies for the 3‐D visualization of chemical and mineralogical variations in unsectioned extraterrestrial samples. These improved methods have been applied to three compositionally diverse chondritic meteorite samples that were between 300 and 400 μm in diameter, including samples prepared from fragments of the CR2 chondrite LaPaz Icefield (LAP) 02342, H5 chondrite MacAlpine Hills (MAC) 88203, and the CM2 chondrite Murchison. The synchrotron‐based XRF and XRD tomographies used are focused‐beam techniques that measure the intensities of fluorescent and diffracted X‐rays in a sample simultaneously during irradiation by a high‐energy microfocused incident X‐ray beam. Measured sinograms of the emitted and diffracted intensities were then tomographically reconstructed to generate 2‐D slices of XRF and XRD intensity through the sample, with reconstructed pixel resolution of 1–2 μm, defined by the resolution of the focused incident X‐ray beam. For sample LAP 02342, primary mineral phases that were visualized in reconstructed slices using these techniques included isolated grains of α‐Fe, orthopyroxene, and olivine. For our sample of MAC 88203, XRF/XRD tomography allowed visualization of forsteritic olivine as a primary mineral phase, a vitrified fusion crust at the sample surface, identification of localized Cr‐rich spinels at spatial resolutions of several micrometers, and imaging of a plagioclase‐rich glassy matrix. In the sample of Murchison, major identifiable phases include clinoenstatite‐ and olivine‐rich chondrules, variable serpentine matrix minerals and small Cr‐rich spinels. Most notable in the tomographic analysis of Murchison is the ability to quantitatively distinguish and visualize the complex mixture of serpentine‐group minerals and associated tochilinite–cronstedtite intergrowths. These methods provide new opportunities for spatially resolved characterization of sample texture, mineralogy, crystal structure, and chemical state in unsectioned samples. This provides researchers an ability to characterize such samples internally with minimal disruption of sample micro‐structures and chemistry, possibly without the need for sample extraction from some types of sampling and capture media.

Geochemistry & Geophysics↗