Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Fire”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,153 records · Page 64

Fire Intensity Data for Validation of the Radiative Transfer Equation

A set of experiments and test data are outlined in this report that provides radiation intensity data for the validation of models for the radiative transfer equation. The experiments were performed with lightly-sooting liquid hydrocarbon fuels that yielded fully turbulent fires 2 m diameter). In addition, supplemental measurements of air flow and temperature, fuel temperature and burn rate, and flame surface emissive power, wall heat, and flame height and width provide a complete set of boundary condition data needed for validation of models used in fire simulations.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Soil Screening Concentrations for Airborne Exposure to Radionuclides Released from Wildland Fires and Fugitive Dust Sources

This document calculates soil screening concentrations for two release scenarios: 1) radionuclides suspended in fugitive dust, and 2) radionuclides on plant surfaces and in plant tissue that are released during a wildland fire on INL Site lands. Soil screening concentrations are based on a dose of 10 mrem effective dose (ED) to a firefighter, INL Site worker, or member of the public. Soil screening concentrations that would result in an effective dose of 10 mrem to an individual (firefighter, INL Site worker, or member of the public) exposed to releases from a wildland fire or fugitive dust emissions were calculated for key radionuclides at the INL. These concentrations are intended to be compared with radionuclide soil measurements to determine whether soil contamination may need to be monitored for or remediated.

54 ENVIRONMENTAL SCIENCES↗

Transient Efficiency, Flexibility, and Reliability Optimization of Coal-Fired Power Plants - Final Report

This program developed an advanced model-based monitoring and model-predictive control algorithms for a coal fired power plant (CFPP), and deployed these algorithms in a real-time platform to demonstrate performance benefits for transient flexibility and plant operation efficiency. More specifically, the objectives were successfully achieved through a combination of (i) developing a high-fidelity transient plant model in Apros, which was used as a high-fidelity plant simulation between $100-50\% TMCR$ where TMCR denotes the turbine maximum continuous rating, i.e., baseload, (ii) developing a very fast physics-based reduced-order model (ROM) of the plant, which ran more than $100\times$ faster than real-time, enabling its use as real-time embedded model for model-based estimation (MBE) and model predictive control (MPC) (iii) implementing a real-time MBE based on ROM using a robust unscented Kalman filter (UKF) to continuously tune the ROM to match the measurements from high-fidelity Apros plant model despite significant plant-model mismatch, and thus, obtain a Digital Twin of the plant (iv) designing and implementing a real-time MPC with dual objectives of transient plant load tracking with high ramp rates and minimizing coal consumption, i.e., improving plant efficiency in the baseload-partload operation range of $100-50\% TMCR$. Each key element above was developed and tested individually, and has been reported in corresponding Topical Reports. Finally, all the individual elements were integrated in an overall closed-loop system, that was successfully tested in desktop Simulink test harness simulations with ROM or high-fidelity model as the plant. Thereafter, the Simulink implementation was used to auto-generate C-code and deploy as real-time Docker microservice containers in Linux, and validate that they can run in real-time in the hardware-in-the loop (HIL) setup and produce the same results as in Simulink. The results of the integrated simulation tests in Simulink as well as the real-time HIL deployment are documented in this final report, showing good load tracking for load ramps at $3-4\%/min$ ramp rates, and achieving up to $5.5\%$ reduction in coal relative to baseline operation at $50\% TMCR$ load. The desktop and HIL simulations show successful performance of the overall model based estimation and control solution and achieve the key objectives of the program for flexible, efficient and reliable operation of subcritical coal fired power plants.

20 FOSSIL-FUELED POWER PLANTS↗

An Integrated Approach to Predicting Ash Deposition and Heat Transfer in Coal-Fired Boilers

The overall goal of this project is to develop via measurements and simulations an advanced online technology to predict, monitor and manage fireside ash deposition in a coal-fired boiler allowing for more efficient operations under a range of load conditions and fuel property variability. With this in place fuel sorting and blending can be done upstream and operations can be optimized to compensate for load and fuel properties. In support of this objective, three experimental campaigns were undertaken during the course of the project to measure ash deposition rates within the boiler at different fuel flow rates and its ash composition variability. Simulations of the experimental conditions representing actual geometry, operational scenarios in terms of air flow rates, coal flow rates as well as coal compositions, heating values, and particle size distributions were also carried out. Deposition rates were predicted using a unique particle kinetic energy and viscosity based ash deposition methodology whose validity was ascertained by comparing against deposition rate measurements for widely varying operating conditions and ash compositions in a lab-scale furnace. With a unique end-to-end combustion modeling methodology established and different simulation scenarios carried out, the results from our computational fluid dynamic (CFD) simulations in conjunction with the plant data summarized in this report were used to refine Microbeam Technology Incorporated’s MTI CSPI-CT Tool to predict and monitor fire-side ash deposition under a range of load conditions and fuel property variability in real time.

01 COAL, LIGNITE, AND PEAT↗

3013 Fire Test 2020: Post-Test Volumes

Sandia National Laboratory conducted fire tests on ten 3013 containers with varying amounts of water. The containers plastically deformed during the fire tests. The plastic deformation increased the free-gas volume within the containers. The amount of plastic deformation is measured and post-test free gas volumes at 25°C is reported.

36 MATERIALS SCIENCE↗

Remaining Sites Verification Package for the 600-111, P-11 Critical Mass Laboratory Crib, and UPR-600-16, Fire and Contamination Spread Waste Sites, Waste Site Reclassification Form 2008-045

The UPR-600-16, Fire and Contamination Spread waste site is an unplanned release that occurred on December 4, 1951, when plutonium contamination was spread by a fire that ignited inside the 120 Experimental Building. The 120 Experimental Building was a laboratory building that was constructed in 1949 and used for plutonium criticality studies as part of the P-11 Project. In November 1951, a criticality occurred in the 120 Experimental Building that resulted in extensive plutonium contamination inside the building. The confirmatory evaluation supports a reclassification of this site to Interim Closed Out. The current site conditions achieve the remedial action objectives and the corresponding remedial action goals established in the Remaining Sites ROD. The results of the extensive radiological survey of the surface soil and the confirmatory and verification sampling show that residual contaminant concentrations do not preclude any future uses and allow for unrestricted use of shallow zone soils. The results also demonstrate that residual contaminant concentrations are protective of groundwater and the Columbia River.

100-IU-6 Operable Unit↗

Emissions, Monitoring, and Control of Mercury from Subbituminous Coal-Fired Power Plants - Phase II

Western Research Institute (WRI), in conjunction with Western Farmers Electric Cooperative (WFEC), has teamed with Clean Air Engineering of Pittsburgh PA to conduct a mercury monitoring program at the WEFC Hugo plant in Oklahoma. Sponsored by US Department of Energy Cooperative Agreement DE-FC-26-98FT40323, the program included the following members of the Subbituminous Energy Coalition (SEC) as co-sponsors: Missouri Basin Power Project; DTE Energy; Entergy; Grand River Dam Authority; and Nebraska Public Power District. This research effort had five objectives: (1) determine the mass balance of mercury for subbituminous coal-fired power plant; (2) assess the distribution of mercury species in the flue gas (3) perform a comparison of three different Hg test methods; (4) investigate the long-term (six months) mercury variability at a subbituminous coal-fired power plant; and (5) assess operation and maintenance of the Method 324 and Horiba CEMS utilizing plant personnel.

01 COAL, LIGNITE, AND PEAT↗

Investigation of Mechanism of Potential Aircraft Fuel Tank Vent Fires and Explosions Caused by Atmospheric Electricity

The nature of the potential fuel tank vent fire and explosion hazard is discussed in relation to present vent exit design practice, available knowledge of atmospheric electricity as a source of ignition energy, and the vent system vapor space environment. Flammable mixtures and possible ignition sources may occur simultaneously as a rare phenomena according to existing knowledge. There is a need to extend the state of science in order to make possible vent design which is aimed specifically at minimizing fire and explosion hazards.

FUEL TANK↗

Project Fire photographic summary and record of reentry phenomena at hyperbolic velocities

Project Fire was undertaken by the National Aeronautics and Space Administration to measure the total and radiative heating experienced by a blunt body reentering the earth's atmosphere at 11 300 meters per second. This report presents a photographic record of the Fire II spacecraft during its reentry. The photographs were clear enough to establish the times of major events, and they show that adequate-separation was maintained between the reentry package and the spent Antares. This report also identifies operational problems encountered in spacecraft reentry at hyperbolic velocities and presents the solutions satisfactorily employed.

Reentry vehicle↗

The Yellowstone Fires as Observed by SIR-C SAR

Covers SIR-C (Spaceborne Imaging Radar C) SAR (Synthetic Aperture Radar) imaging of the 1988 Yellowstone National Forest fires. Discusses some of the images and data collected, and some conclusions drawn from them about both the fires, and SIR-C SAR imaging capabilities.

SIR-C Spaceborne Imaging Radar C Radar SAR Synthet↗

Integrating Land Cover Modeling and Adaptive Management to Conserve Endangered Species and Reduce Catastrophic Fire Risk

Land cover modeling is used to inform land management, but most often via a two-step process where science informs how management alternatives can influence resources and then decision makers can use this to make decisions. A more efficient process is to directly integrate science and decision making, where science allows us to learn to better accomplish management objectives and is developed to address specific decisions. Co-development of management and science is especially productive when decisions are complicated by multiple objectives and impeded by uncertainty. Multiple objectives can be met by specification of tradeoffs, and relevant uncertainty can be addressed through targeted science (i.e., models and monitoring). We describe how to integrate habitat and fuels monitoring with decision making focused on dual objectives of managing for endangered species and minimizing catastrophic fire risk. Under certain conditions, both objectives might be achieved by a similar management policy, but habitat trajectories suggest tradeoffs. Knowledge about system responses to actions can be informed by applying competing management actions to different land units in the same system state and by ideas about fire behavior. Monitoring and management integration is important to optimize state-specific management decisions and increase knowledge about system responses. We believe this approach has broad utility for and cover modeling programs intended to inform decision making.

adaptive management↗

Evaluation of Global Fire Weather Database Reanalysis and Short-Term Forecast Products

Daily Fire Weather Index (FWI) System components calculated from the NASA Modern-Era Retrospective analysis for Research and Applications, Version 2 (MERRA-2), are compared to FWI calculations from a global network of weather stations over 2004–2018, and short-term, experimental (8 d) daily FWI forecasts are evaluated for their skill across the Terrestrial Ecoregions of the World for 2018. FWI components from MERRA-2 were, in general, biased low compared to station data, but this reflects a mix of coherent low and high biases of different magnitudes. Biases in different MERRA-2 FWI components were related to different biases in weather input variables for different regions, but temperature and relative humidity biases were the most important overall. FWI forecasts had high skill for 1–2 d lead times for most of the world. For longer lead times, forecast skill decreased most quickly at high latitudes and was most closely related to decreasing skill of relative humidity forecasts. These results provide a baseline for the evaluation and use of fire weather products calculated from global analysis and forecast fields.

Global Fire Weather Database↗

Evolving Role of Aircraft and Airspace Operations for Aerial Fire Mitigation

Various sizes and types of aircraft are envisioned to play a critical role in fighting fires. Multiple aircraft, including drones, operating simultaneously to fight fires requires coordination to maintain effectiveness as well as safety. Presently, firefighting is limited to day time, high visibility, and low wind conditions. It is also impacted if unmanned aircraft system operates in the area or nearby. NASA is exploring opportunities where a variety of aircraft and their coordinated airspace management would improve the effectiveness of aerial firefighting. Dr. Kopardekar will discuss future aircraft requirements, approach for coordinated firefighting as well as a path towards improving effectiveness.

Aerial Fire Mitigation↗

A New Test Methodology for Evaluating Fire Risk Due to Electrical Faults in Oxygen-Enriched Environments

This paper discusses a new test methodology for assessing the safe use of materials found in spacecraft that may be exposed to electrical faults, as performed at the NASA White Sands Test Facility. “Wire-break” testing, modeled after the Cleveland Open Cup method, identifies the conditions under which pyrolyzed material transitions from a brief flash to a propagating flame. The approach focuses on fuel mass liberated through pyrolysis, mixed with oxygen, and ignited by a piloted ignition (spark due to fusion of wire) to achieve flame propagation with the least energy. The test approach attempts to find energy density thresholds derived using I²t values from current-induced heating of various test materials and wire characteristics. The application of the data provides a useful approach to mitigating fire risks in space systems by correlating threshold data to real-world designs and scaling factors, including oxygen pressure, wire diameter, heat sinking, and contained smoke volume. Several case studies, including Apollo missions and hypothetical scenarios, illustrate practical applications of these thresholds to enhance fire safety design considerations in space environments.

methodology↗

Effects of the MacArthur Maze Fire and Roadway Collapse on a Spent Nuclear Fuel Transportation Package

In 2007, a severe transportation accident occurred near Oakland, California, on a section of Interstate 880 known as the "MacArthur Maze," involving a tractor trailer carrying gasoline which impacted an overpass support column and burst into flames. The subsequent fire caused the collapse of portions of the Interstate 580 overpass onto the remains of the tractor-trailer in less than 20 minutes, due to a reduction of strength in the structural steel exposed to the fire. The US Nuclear Regulatory Commission is in the process of examining the impacts of this accident on the performance of a spent nuclear fuel transportation package, using detailed analysis models, in order to determine the potential regulatory implications related to the safe transport of spent nuclear fuel in the United States. This paper will provide a summary of this ongoing effort and present some preliminary results and conclusions.

extra-regulatory fire↗

Wild Fire Computer Model Helps Firefighters

A high-tech computer model called HIGRAD/FIRETEC, the cornerstone of a collaborative effort between U.S. Forest Service Rocky Mountain Research Station and Los Alamos National Laboratory, provides insights that are essential for front-line fire fighters. The science team is looking into levels of bark beetle-induced conditions that lead to drastic changes in fire behavior and how variable or erratic the behavior is likely to be.

54 ENVIRONMENTAL SCIENCES↗

Transient Efficiency, Flexibility, and Reliability Optimization of Coal-Fired Power Plants - Final Program Review

This program developed an advanced model-based monitoring and model-predictive control algorithms for a coal fired power plant (CFPP), and deployed these algorithms in a real-time platform to demonstrate performance benefits for transient flexibility and plant operation efficiency. More specifically, the objectives were successfully achieved through a combination of (i) developing a high-fidelity transient plant model in Apros, which was used as a high-fidelity plant simulation between $100-50\% TMCR$ where TMCR denotes the turbine maximum continuous rating, i.e., baseload, (ii) developing a very fast physics-based reduced-order model (ROM) of the plant, which ran more than $100\times$ faster than real-time, enabling its use as real-time embedded model for model-based estimation (MBE) and model predictive control (MPC) (iii) implementing a real-time MBE based on ROM using a robust unscented Kalman filter (UKF) to continuously tune the ROM to match the measurements from high-fidelity Apros plant model despite significant plant-model mismatch, and thus, obtain a Digital Twin of the plant (iv) designing and implementing a real-time MPC with dual objectives of transient plant load tracking with high ramp rates and minimizing coal consumption, i.e., improving plant efficiency in the baseload-partload operation range of $100-50\% TMCR$. Each key element above was developed and tested individually, and has been reported in corresponding Topical Reports. Finally, all the individual elements were integrated in an overall closed-loop system, that was successfully tested in desktop Simulink test harness simulations with ROM or high-fidelity model as the plant. Thereafter, the Simulink implementation was used to auto-generate C-code and deploy as real-time Docker microservice containers in Linux, and validate that they can run in real-time in the hardware-in-the loop (HIL) setup and produce the same results as in Simulink. The results of the integrated simulation tests in Simulink as well as the real-time HIL deployment are documented in this final report, showing good load tracking for load ramps at $3-4\%/min$ ramp rates, and achieving up to $5.5\%$ reduction in coal relative to baseline operation at $50\% TMCR$ load. The desktop and HIL simulations show successful performance of the overall model based estimation and control solution and achieve the key objectives of the program for flexible, efficient and reliable operation of sub-critical coal fired power plants.

20 FOSSIL-FUELED POWER PLANTS↗