Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “FEET”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,153 records · Page 64

Pretreated Waste and Melter Feed Composition Variability Testing Using LAW Simulants

This report documents the results of the testing that was performed to fulfill the Low Activity Waste (LAW) pretreated waste and melter feed product qualification requirements for Chemical Composition during Production as described in the Immobilized Low Activity Waste (ILAW) Product Compliance Plan and the Waste Treatment and Immobilization Plant (WTP) Contract. Meeting the product quality specifications relies on controlling the LAW melter feed preparation process and the resulting ILAW glass composition. In part, this control depends on (1) the ability of the Concentrate Receipt Vessel (CRV) system to homogenize the pretreated LAW concentrate feed, provide representative sampling of the vessel contents, measure the content level over the vessel operating range, and uniformly transfer the vessel contents, and (2) the ability of the Melter Feed Preparation Vessel (MFPV) system to homogenize the LAW melter feed after addition of the glass forming chemicals (GFCs) and uniformly transfer the vessel contents. A series of tests were conducted on a single scaled down tank, 8 feet in diameter, which was used to represent the WTP LAW CRV and the LAW MFPV. Prototypic equipment (such as radar level detectors, transfer pumps, agitators, and density probes) was installed in geometrically similar positions to those of the WTP tanks. Other equipment, which is not fully prototypic, was also installed in the tank to fully represent the WTP tank equipment arrangement. In addition, a prototypic autosampler and a hydraulically similar transfer line were installed to represent the WTP tank sampling systems. Testing was performed using simulants that represent the high and low bounds of rheology for the pretreated LAW prior to GFC addition and the LAW melter feed after GFC additions.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Pretreated Waste and Melter Feed Composition Variability Testing Using HLW Simulants

This report documents the results of the testing that was performed to fulfill the High Level Waste (HLW) pretreated waste and melter feed product qualification requirements for chemical composition and product loading as described in the Immobilized High Level Waste (IHLW) Wasteform Compliance Plan and the Hanford Tank Waste Treatment and Immobilization Plant (WTP) Contract. Meeting the product quality specifications relies on controlling the melter feed preparation process and the resulting IHLW glass composition. In part, this control depends on the ability of the Melter Feed Preparation Vessel (MFPV) system to homogenize pretreated waste and the melter feed after addition of the glass forming chemicals (GFCs), provide representative sampling of the vessel contents, measure the level over the vessel operating range, and uniformly transfer the vessel contents. A series of tests were conducted on a single scaled down tank, 8 feet in diameter, which was used to represent the WTP HLW MFPV. Prototypic equipment (such as radar level detectors, transfer pumps, agitators, and density probes) was installed in geometrically similar positions to those of the WTP tanks. Other equipment, which is not fully prototypic, was also installed in the tank to fully represent the WTP tank equipment arrangement. In addition, a prototypic autosampler and a hydraulically similar transfer line were installed to represent the WTP tank sampling systems. Testing was performed using simulants that represent the high and low bounds of rheology for the pretreated HLW prior to GFC addition and the HLW melter feed after GFC addition.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Effect of Citrate on the Solubility of Uranium (VI) in WIPP Brine

The Waste Isolation Pilot Plant (WIPP) is the only active deep geological repository in the United States for the disposal of defense-related transuranic (TRU) waste, located in the northern part of the Delaware Basin in southeastern New Mexico, approximately 26 miles east of Carlsbad. The repository is situated 2,150 feet (about 610 meters) underground within the Salado Formation, a thick layer of stable salt deposits. This unique geological formation provides a secure and long-term environment for isolating TRU waste, ensuring its safe containment for thousands of years.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

lllinois Storage Corridor CarbonSAFE Phase III: Pre-drilling Site Assessment: Prairie State Generating Company

The Illinois Storage Corridor project will drill a stratigraphic test well as part of the Illinois Storage Corridor CarbonSAFE Phase 3 project near the Prairie State Generating Company coal-fired power plant near Marissa, Illinois. The pre-drilling site evaluation has considered the primary target reservoirs, the Potosi Dolomite and St. Peter Sandstone, and primary seal, the Maquoketa Group. Data to be collected from the well include core, fluid samples, in situ well tests, geophysical logs intended to provide information on lithologic, geomechanical, and geophysical characteristics to determine the feasibility for the geologic sequestration of 50 million metric tons or more of injected carbon dioxide. The planned drilling site has been evaluated using available subsurface geologic data and analyses from the Illinois Basin. These data provide lithologic and structural information, shallow groundwater resource distribution, location of known nearby wellbores, and regional drilling characteristics. The data were used to generate geologic structure and isopach maps for the target reservoir and caprock strata and for prognosing the tops of major lithologic units to aid drilling and coring procedures. The regional analyses indicate that no known structural features are expected to negatively impact the target storage reservoir or caprock. No protected and sensitive areas, groundwater resources, or existing resource development are expected to be impacted by the proposed well drilling activities. The well is planned to be drilled to a total depth of approximately 5,600 feet (1,707 m) and terminate in the Precambrian. Cores (up to 5 intervals) will be collected from the Maquoketa Group, confining units above the St. Peter Sandstone, St. Peter Sandstone, confining units of the Potosi Dolomite and the Potosi Dolomite. Water samples will be attempted to be collected from the St. Peter Sandstone and Potosi Dolomite. Potential impact on drilling progress is a lost circulation zone in the Potosi Dolomite, which has been demonstrated to have intermittent cavernous porosity from karstification elsewhere in the Illinois Basin. This document also presents a preliminary coring and sampling program, proposed logging suite, and well testing program, all of which will be reviewed during drilling.

01 COAL, LIGNITE, AND PEAT↗

Composition Variability Testing Using High Bounding LAW Melter Feed Simulant

This report documents the results of the testing that was performed to fulfill the Low Activity Waste (LAW) pretreated waste and melter feed product qualification requirements for Chemical Composition during Production as described in the Immobilized Low Activity Waste (ILAW) Product Compliance Plan and the Waste Treatment and Immobilization Plant (WTP) Contract. Meeting the product quality specifications relies on controlling the LAW melter feed preparation process and the resulting ILAW glass composition. In part, this control depends on the ability of the Melter Feed Preparation Vessel (MFPV) system to adequately mix the LAW melter feed after addition of the glass forming chemicals (GFCs), provide representative sampling of the vessel contents, measure the content level over the vessel operating range, and uniformly transfer the vessel contents. A series of tests were conducted on a 72.7% scaled down tank, 8 feet in diameter, which was used to represent the LAW MFPV. Prototypic equipment (such as radar level detectors, transfer pumps, agitators, and density probes) was installed in geometrically similar positions to that of the WTP tank. Other equipment, which is not fully prototypic, was also installed in the tank to fully represent the WTP tank equipment arrangement. In addition, a prototypic autosampler and a hydraulically similar transfer line were installed to represent the WTP tank sampling systems. Testing was performed using a simulant that represented the high bound of rheology for the LAW melter feed.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Carbon Capture on Air Liquide United States Gulf Coast Steam Methane Reformer using the Cryocap TM Flue Gases Process

The objective of this DOE-funded project is to execute and complete a Front-End Engineering and Design (FEED) study for a commercial-scale carbon capture project for Air Liquide’s Steam Methane Reformer (SMR) located at La Porte, near Houston, Texas. The Host Site is one of Air Liquide’s largest SMR assets, and supplies hydrogen to the Air Liquide Gulf Coast Hydrogen System, which serves refiners and petrochemical manufacturers through an existing H2 pipeline spanning roughly 200 miles from Port Arthur, TX to Bay City, TX. The Host Site produces up to 116.5 million standard cubic feet per day (MMSCFD) of gaseous hydrogen and emits approximately 950 ktpy CO 2 at the nameplate capacity. The evolving importance of decarbonized H2 for both existing customers and new markets, as well as the availability and intent of prominent third-party partners to transport and sequester captured CO 2 in locally abundant geological sites for 45Q credits, make the AL US Gulf Coast SMR an ideal site for the proposed FEED study. The envisioned carbon capture system is based on Air Liquide’s proprietary Cryocap™ Flue Gas (FG) process. The integration of the Cryocap™ FG technology to the existing SMR would enable the capture of 900 ktpy of CO 2 , with a net carbon capture rate of >95% and with minimum impact on the levelized cost of hydrogen produced at 99.97% purity.

03 NATURAL GAS↗

Technical Basis SAVY-4000® Series, 5.5G Container (Rev. 1)

The 5.5 Gallon (5.5G) SAVY-4000® nuclear material storage container is the latest in the SAVY-4000® series. The 5.5G is similar to that of a 1or 2Qt container in functionality with the exception of a larger volume deep drawn and spun form body achieved through increases in the depth and diameter of the container. Here, a technical basis using engineering equivalency analysis, calculation, and test data is presented to establish that the 5.5G SAVY-4000® Container is a DOE Manual 441.1-1 compliant container at a drop height of 9 feet (rather than the typical 12 ft of the other SAVY-4000® containers) and that a twenty-five year design life (as with the currently approved SAVY-4000® series) is justified.

99 GENERAL AND MISCELLANEOUS↗

The Hanford Waste End Effector Phase II Test Report

This report describes the Phase II testing program of the Hanford Waste End Effector (HWEE) at the Washington River Protection Solutions Cold Test Facility (CTF). Phase II testing builds on the completed Phase I development testing (PNNL-26856) to address some key actual waste challenges as outlined in the Phase II test plan (PNNL-27422). This testing demonstrated retrieval of a mixed layered simulant and retrieval of uneven simulant profiles like that found near tank walls. A separate demonstration using only the HWEE conveyance jet pump assessed the lifting capabilities of this device for transporting waste out of an underground tank. The Pacific Northwest National Laboratory (PNNL)-designed robotic gantry system and associated systems (e.g., tanks, high-pressure water delivery and valves, instruments, etc.) used at CTF during Phase I were modified and upgraded to implement the Phase II test program and measure various process parameters. The tests demonstrated retrieval of water and Kaolin (sludge) simulant to determine pumping rate, dilution factors, and screen fouling rate. This report will first describe the test equipment, instrumentation, simulant preparation procedures, and testing methodology. Testing results presented include HWEE water usage versus operating pressure of modified components from Phase I, simulant characterization data, dilution ratios, and retrieval rates. Reaction forces and other factors that would affect the remote operation of the HWEE will also be presented. Results of the separate jet pump vertical lift demonstration to a fixed height of at least 35 feet are also presented.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Analysis of the Costs of a Backlog Project in Response to Recommendation 2 of the 2004 Archives and History Office Program Review Committee Report

SLAC Archives and History Office (AHO) backlog of unprocessed material is over 3,000 cubic feet and growing. Because much of this material was directly transferred to off-site storage, the provenance and contents are a mystery. The costs of off-site storage, lack of knowledge of the contents, and the impending federal regulations in 2009 concerning storage facilities all suggest the need for a long-term plan for the backlog. AHO presents these options to SLAC management: (1) Continue with the status quo, adding new accessions to OffSite Records Management, LLC (hereinafter referred to as OffSite) storage; (2) Pull the backlog back a segment at a time for box-level processing, determine what is in each box, get rid of extraneous material, and return what is left to OffSite storage; (3) Gradually retrieve the backlog for thorough, folder-level processing and then transfer to the Federal Records Center in San Bruno (hereinafter referred to as FRC) or the Archives side of the operations at the National Archives and Records Administration in San Bruno (hereinafter referred to as NARA); and (4) Gradually retrieve the backlog for a combination of box-level processing with return to OffSite storage and thorough folder-level processing with transfer to FRC or NARA.

43 PARTICLE ACCELERATORS↗

Soil Sampling Plan in Support of the Human Health and Ecological Risk Assessment for the Operation of the Explosives Waste Treatment Facilitiy at Site 300 of the Lawrence Livermore National Laboratory

LLNL proposes to obtain soil samples from the following areas: (1) Four areas downwind of the Explosives Waste Treatment Facility (EWTF) Burn Units (i.e., Thermal Treatment Unit and Burn Pan); (2) One area upwind of the Burn Units and Detonation Pad; (3) Two areas downwind of the EWTF Detonation Pad; and (4) Three areas unaffected (representing ambient conditions) by EWTF operations approximately 7000-8000 feet upwind of the facility. The purpose of the sampling in areas 1, 2, and 3 is to detect if operations cause increases in concentrations of materials downwind of the Burn Units or downwind of the Detonation Pad. The purpose of the sampling in area 4 is to determine if previously developed background screening levels can be applied to EWTF operations. A 20 foot diameter circle will define each sample area. Soil samples will be obtained from four random locations inside each 20 foot circle. The samples will be obtained immediately below the surface, free of any organic matter (e.g., roots) and other surface and subsurface material (e.g., rocks) that is not conducive to analysis. The random identification of four discrete sample locations in each circle will allow the variability between sample locations and areas, if present, to be evaluated statistically. At a minimum, data will be evaluated by the Wilcoxon Rank Sum test. All future sampling will occur in the same 20 foot diameter circle; however, only one randomly located sample (instead of four) will be obtained. Future samples will be analyzed for the same chemicals of potential ecological concern (CPECs) as the initial sample. Sample areas and locations will be recorded by Global Positioning System coordinates.

54 ENVIRONMENTAL SCIENCES↗

Extension of 4-8 Texture Hierarchies to Large Video Processing and Visualization

The purpose of this Techbase was to reduce to practice the tiled 4-8 texture hierarchy for the display of video imagery (i.e. sequences of frames). The immediate intent was to demonstrate its use in the analysis and display of sensor imagery. As sensors are increasing in resolution the physical amount of imagery that needs to be displayed can quickly overwhelm most display systems. For example, a sensor with a horizontal resolution of over 8000 pixels would generate an image over 10 feet wide on a standard 72 DPI display. Breaking an image into tiles, and then decomposing each tile into a multiresolution hierarchy, allows a user (or software) to efficiently select and display only those parts of the image that are of interest to the user. The originator of the idea of 4-8 Texture Hierarchies was Dr. Mark Duchaineau, and we consulted with him in much of our work. We also consulted with Dan Knight, from SequoiaTek Corp., who is a contractor responsible for implementing the viewers for our applications. Most of the code for actual 4-8 Texture Hierarchy generation already existed; a large focus of the Techbase was to determine how to best use what was available for video imagery. The majority of progress was made in specifying and implementing the software framework, which turned out to be rather involved. This framework is to support the creation, storage, and display of images, both tiled and untiled. A first albeit incomplete version was successfully tested in the field in August 2007. The framework structures the process of collecting and processing images conceptually as a pipeline, where work is passed along and a different operation is performed at each stage. In practice, the pipeline is implemented by a group of processes (not threads), or 'workers', each responsible for a specific type of operation. Associated with these workers is a pool of memory (cache). As each process finishes its work, it places the results into the cache and sends a message to the process responsible for the next operation, including in the message an identifier allowing the recipient to locate the data to be worked on. Conceptually this is akin to transferring mail from person to person by placing it into and removing it from a group of mail slots, rather than handing it to the next person directly. So for example, to capture, tile, and store imagery to disk, one worker would be responsible for obtaining an image from an electro-optical sensor. Another would be responsible for breaking the image into tiles, and another for performing a decorrelating transform for entropy reduction and multiresolution representation. Still another would be responsible for compression, and another for storage. To maximize robustness in an experimental environment, we created a manager that could monitor, kill, restart, and configure the entire processing pipeline, including the shared cache and worker processes. In the event of hardware or software failure, individual elements of the pipeline were restored automatically and with minimum data loss. Working with Mark Duchaineau we attempted to determine a set of ideal coefficients for the wavelet used to create the multiresolution hierarchy. While a workable set exists, it produces undesirable artifacts at high levels of loss, so more work needs to be done to identify a more ideal set. The tiler and data structures for tiling and display have been added to the code base we developed. As currently implemented it takes approximately one second to tile and build a multiresolution hierarchy for an 11-megapixel image on a 3.8 GHz Pentium 4. This is too slow for some uses, so some work will probably need to be done to optimize the code. We may be able to leverage commodity graphics processors to gain extra speed. With the advent of quad-core CPUs it may also be possible to get required throughput by tiling the image and then having several processes run in parallel to build the multiresolution hierarchies for the resulting tiles. Additionally, more work needs to be done to define a data format for storing image tiles on disk, as well as retrieving and displaying them. As this functionality is desirable (and required, if we are to make large data easily viewable) we will be spending a lot of time developing this. As a final note, it was recently brought to our attention that Oracle provides an extension to its database technology that provides most, if not all, of the functionality that we are working on as part of this project. We will be investigating this further; if a suitable solution already exists it may be more valuable time-wise to integrate it into projects that require storing and displaying large images.

99 GENERAL AND MISCELLANEOUS↗

Closed Crawl Space Performance: Proof of Concept in the Production Builder Marketplace

This overview is intended to be a very concise, limited summary of the key project activities discussed in the detailed report that follows. Due to the large scope of this project, the detailed report is broken into three individually titled sections. Each section repeats key background information, with the goal that the sections will eventually stand alone as complete reports on the major activities of the project. The information presented herein comes from ongoing research, so please note that all observations, findings and recommendations presented are preliminary and subject to change in the future. We invite and welcome your comments and suggestions for improving the project. Advanced Energy completed its first jointly-funded crawl space research project with the Department of Energy in 2005. That project, funded under award number DE-FC26-00NT40995 and titled 'A Field Study Comparison of the Energy and Moisture Performance Characteristics of Ventilated Versus Sealed Crawl Spaces in the South' demonstrated the substantial energy efficiency and moisture management benefits that result from using properly closed crawl space foundations for residential construction instead of traditional wall vented crawl space foundations. Two activities of this first project included (1) an assessment of ten existing homes to document commonly observed energy and moisture failures associated with wall-vented crawl space foundations and (2) a detailed literature review that documented both the history of closed crawl space research and the historical lack of scientific justification for building code requirements for crawl space ventilation. The most valuable activity of the 2005 project proved to be the field demonstration of various closed crawl space techniques, which were implemented in a set of twelve small (1040 square feet), simply designed homes in eastern North Carolina. These homes had matched envelope, mechanical and architectural designs, and comparable performance characteristics with regard to infiltration and duct leakage. Researchers settled on two closed crawl space designs, one with insulation located in the framed floor structure above the crawl space and one with insulation on the crawl space perimeter wall, as the designs with the most widespread potential for application. Researchers based this assessment not only on the field performance, but also on input from residential builders, pest control professionals, code officials, installers, and building scientists active in the region. The key findings from the field demonstration were that (1) closed crawl spaces stay substantially drier than traditional wall-vented crawl spaces during humid climate conditions, and (2) the houses built on the closed crawl space foundations saved, on average, 15% or more on annual energy used for space heating and cooling. A comparison of the actual energy performance of the homes versus the performance predicted by a popular HERS software application showed that the software was unable to predict the demonstrated savings, in some cases predicting an energy penalty. Findings from the 2005 project were summarized in a publication titled Closed Crawl Spaces: An Introduction to Design, Construction and Performance. Since its release, the publication has received widespread use by builders, homeowners, installers and code officials concerned about crawl space construction. The findings were also used to create major revisions to the NC Residential Code, which were adopted in 2004 and immediately began to reduce the regulatory barriers to widespread commercialization of the technology in NC, particularly in new residential construction. Full project details are located at www.crawlspaces.org.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Natural gas pipeline technology overview.

The United States relies on natural gas for one-quarter of its energy needs. In 2001 alone, the nation consumed 21.5 trillion cubic feet of natural gas. A large portion of natural gas pipeline capacity within the United States is directed from major production areas in Texas and Louisiana, Wyoming, and other states to markets in the western, eastern, and midwestern regions of the country. In the past 10 years, increasing levels of gas from Canada have also been brought into these markets (EIA 2007). The United States has several major natural gas production basins and an extensive natural gas pipeline network, with almost 95% of U.S. natural gas imports coming from Canada. At present, the gas pipeline infrastructure is more developed between Canada and the United States than between Mexico and the United States. Gas flows from Canada to the United States through several major pipelines feeding U.S. markets in the Midwest, Northeast, Pacific Northwest, and California. Some key examples are the Alliance Pipeline, the Northern Border Pipeline, the Maritimes & Northeast Pipeline, the TransCanada Pipeline System, and Westcoast Energy pipelines. Major connections join Texas and northeastern Mexico, with additional connections to Arizona and between California and Baja California, Mexico (INGAA 2007). Of the natural gas consumed in the United States, 85% is produced domestically. Figure 1.1-1 shows the complex North American natural gas network. The pipeline transmission system--the 'interstate highway' for natural gas--consists of 180,000 miles of high-strength steel pipe varying in diameter, normally between 30 and 36 inches in diameter. The primary function of the transmission pipeline company is to move huge amounts of natural gas thousands of miles from producing regions to local natural gas utility delivery points. These delivery points, called 'city gate stations', are usually owned by distribution companies, although some are owned by transmission companies. Compressor stations at required distances boost the pressure that is lost through friction as the gas moves through the steel pipes (EPA 2000). The natural gas system is generally described in terms of production, processing and purification, transmission and storage, and distribution (NaturalGas.org 2004b). Figure 1.1-2 shows a schematic of the system through transmission. This report focuses on the transmission pipeline, compressor stations, and city gates.

03 NATURAL GAS↗

Legacy Compliance Final Report: Results of the Navy/Encapo Soil Stabilization Study at the Nevada Test Site, Nye County, Nevada

Historic atmospheric testing of nuclear devices at the Nevada Test Site (NTS) has resulted in large areas of plutonium-contaminated surface soils. The potential transport of these contaminated soils to onsite and offsite receptors is a concern to the land steward and local stakeholders. The primary transport pathways of interest at the NTS are sediment entrained in surface water runoff and windblown dust. This project was initially funded by the U.S. Navy and subsequently funded by the USDOE Stockpile Stewardship Program. Field tests were conducted over a 20.5 month period to evaluate the efficacy of an organic-based, surface applied emulsion to reduce sediment transport from plutonium-contaminated soils. The patented emulsion was provided by Encapco Technologies LLC. Field tests were conducted within the SMOKY radioactive contamination area (CA). The SMOKY above ground nuclear test was conducted on 08/31/1957, with a reported yield of 44 kilotons and was located at N 37 degrees 10.5 minutes latitude and W 116 degrees 04.5 minutes longitude. Three 'safety tests' were also conducted within approximately 1,500 meters (5,000 feet) of the SMOKY ground zero in 1958. Safety tests are designed to test the response of a nuclear device to an unplanned external force (e.g., nearby detonation of conventional explosives). These three safety tests (CERES, OBERON, and TITANIA) resulted in dispersal of plutonium over a wide area (Bechtel Nevada, 2002). Ten 3 x 4.6 meter test plots were constructed within the SMOKY CA to conduct rainfall-runoff simulations. Six of the ten test plots were treated with the emulsion at the manufacturer recommended loading of 1.08 gallons per square meter, and four plots were held untreated as experimental controls. Separate areas were also treated to assess impacts to native vegetation and surface infiltration rate. Field tests were conducted at approximately 6, 13, and 20.5 months post emulsion treatment. Field tests consisted of rainfall-runoff simulations and double ring infiltrometer measurements. Plant vigor assessments were conducted during peak production time, approximately seven months post treatment. Rainfall was simulated at the approximate 5 minute intensity of a 50-year storm (5.1 inches per hour) for durations of four to five minutes. All runoff generated from each test plot was collected noting the time for each liter of volume. Five gallon carboys containing the runoff water and sediment were shipped to Clemson Environmental Technologies Laboratory for analysis. The samples were separated into liquid and solid fractions. Liquid and solid fractions were weighed and analyzed for Americium-241 (Am-241) by gamma spectrometry. Quality control measures used at the laboratory indicate the analytical data are accurate and reproducible. A weather station was deployed to the field site to take basic meteorological measurements including air temperature, incoming solar radiation, wind speed, wind direction, barometric pressure, relative humidity, precipitation, and volumetric soil moisture content. Meteorological monitoring data indicate the climate over the test period was hot and dry with 41 days having measurable precipitation. The total precipitation for the study period was 12.5 centimeters, 37% of the long-term average. For the 20.5 month test period, 64 freeze-thaw cycles occurred. Vegetation assessments indicate the emulsion treatment did not negatively impact existing vegetation. The three rounds of double ring infiltration tests on treated surfaces indicate the infiltration rate was relatively constant over time and not significantly different from measurements taken on untreated surfaces. Significant differences were observed in the amount of runoff and sediment collected from treated and untreated plots for the first two but not the third round of rainfall-runoff simulations, indicating significant emulsion degradation after 20.5 months of exposure. Treated plots had higher total runoff volumes and sediment loads as compared to untreated plots for the first two rounds of simulations. These data indicate the treatment caused the treated surfaces to repel more of the simulated rainfall than the untreated plots but did not increase the cohesion between soil particles to resist soil particle detachment and transport with the runoff water. Am-241 concentration in collected sediments varied as a function of proximity to the safety test locations, not as a function of surface treatment. The results from field testing the Encapco emulsion indicate it is not a viable long-term option for the stabilization of radionuclide impacted surface soils at the Nevada Test Site in its current formulation. Dust suppression studies conducted by Etyemezian et al. (2006) at an uncontaminated location near the SMOKY site indicate the emulsion significantly reduced dust emissions for at least four months post application, indicating the emulsion may be useful for short-term applications.

54 ENVIRONMENTAL SCIENCES↗

An Aerial Radiological Survey of Selected Areas of the City of North Las Vegas

As part of the proficiency training for the Radiological Mapping mission of the Aerial Measuring System (AMS), a survey team from the Remote Sensing Laboratory-Nellis (RSL-Nellis) conducted an aerial radiological survey of selected areas of the city of North Las Vegas for the purpose of mapping natural radiation background and locating any man-made radioactive sources. Survey areas were selected in collaboration with the City Manager's office and included four separate areas: (1) Las Vegas Motor Speedway (10.6 square miles); (2) North Las Vegas Downtown Area (9.2 square miles); (3) I-15 Industrial Corridor (7.4 square miles); and (4) Future site of University of Nevada Las Vegas campus (17.4 square miles). The survey was conducted in three phases: Phase 1 on December 11-12, 2007 (Areas 1 and 2), Phase 2 on February 28, 2008 (Area 3), and Phase 3 on March 19, 2008 (Area 4). The total completed survey covered a total of 44.6 square miles. The flight lines (without the turns) over the surveyed areas are presented in Figures 1, 2, 3, and 4. A total of eight 2.5-hour-long flights were performed at an altitude of 150 ft above ground level (AGL) with 300 feet of flight-line spacing. Water line and test line flights were conducted over the Lake Mead and Government Wash areas to ensure quality control of the data. The data were collected by the AMS data acquisition system (REDAR V) using an array of twelve 2-inch x 4-inch x 16-inch sodium iodide (NaI) detectors flown on-board a twin-engine Bell 412 helicopter. Data, in the form of gamma energy spectra, were collected continually (every second) over the course of the survey and were geo-referenced using a differential Global Positioning System. Collection of spectral data allows the system to distinguish between ordinary fluctuations in natural background radiation levels and the signature produced by man-made radioisotopes. Spectral data can also be used to identify specific radioactive isotopes. As a courtesy service, with the approval of the U.S. Department of Energy, National Nuclear Security Administration, Nevada Site Office, RSL-Nellis is providing this summary to the office of the Mayor of the City of North Las Vegas along with the gross-count-based exposure rate and man-made count contour maps and GIS shape files in electronic format on a compact disk.

54 ENVIRONMENTAL SCIENCES↗

Nevada Test Site 2007 Waste Management Monitoring Report Area 3 and Area 5 Radioactive Waste Management Sites

Environmental monitoring data were collected at and around the Area 3 and Area 5 Radioactive Waste Management Sites (RWMSs) at the Nevada Test Site. These data are associated with radiation exposure, air, groundwater, meteorology, vadose zone, subsidence, and biota. This report summarizes the 2007 environmental data to provide an overall evaluation of RWMS performance and to support environmental compliance and performance assessment (PA) activities. Some of these data (e.g., radiation exposure, air, and groundwater) are presented in other reports (National Security Technologies, LLC, 2007a; 2008; Warren and Grossman, 2008). Direct radiation monitoring data indicate exposure levels at the RWMSs are at background levels. Air monitoring data at the Area 3 and Area 5 RWMSs indicate that tritium concentrations are slightly above background levels. A single gamma spectroscopy measurement for cesium was slightly above the minimum detectable concentration, and concentrations of americium and plutonium are only slightly above detection limits at the Area 3 RWMS. The measured levels of radionuclides in air particulates are below derived concentration guides for these radionuclides. Radon flux from waste covers is well below regulatory limits. Groundwater monitoring data indicate that the groundwater in the uppermost aquifer beneath the Area 5 RWMS is not impacted by facility operations. The 136.8 millimeters (mm) (5.39 inches [in.]) of precipitation at the Area 3 RWMS during 2007 is 13 percent below the average of 158.1 mm (6.22 in.), and the 123.8 mm (4.87 in.) of precipitation at the Area 5 RWMS during 2007 is 6 percent below the average of 130.7 mm (5.15 in.). Soil-gas tritium monitoring at borehole GCD-05U continues to show slow subsurface migration consistent with previous results. Water balance measurements indicate that evapotranspiration from the vegetated weighing lysimeter dries the soil and prevents downward movement percolation of precipitation more effectively than evaporation from the bare-soil weighing lysimeter. Data from the automated vadose zone monitoring system for the operational waste pit covers show that evaporation continues to slowly remove soil moisture that came from the heavy precipitation in the fall of 2004 and the spring of 2005. The vegetated final mono-layer cover on the U-3ax/bl disposal unit at the Area 3 RWMS effectively removes moisture from the cover by evapotranspiration. During 2007, there was no drainage through 2.4 meters (8 feet) of soil from the Area 3 drainage lysimeters that received only natural precipitation or were vegetated but water drained from the bare-soil Area 3 drainage lysimeter that received 3 times natural precipitation. Elevated tritium levels in plants and animals sampled from the Area 3 and Area 5 RWMSs show tritium uptake by the biota, but the low levels of other radionuclides do not suggest that there has been intrusion into the waste. All 2007 monitoring data indicate that the Area 3 and Area 5 RWMSs are performing within expectations of the model and parameter assumptions for the facility PAs.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Post-Closure Inspection and Monitoring Report for Corrective Action Unit 110: Area 3 WMD U-3ax/bl Crater, Nevada Test Site, Nevada, For the Period July 2007-June 2008

This Post-Closure Inspection and Monitoring Report (PCIMR) provides the results of inspections and monitoring for Corrective Action Unit (CAU) 110, Area 3 WMD [Waste Management Division] U-3ax/bl Crater. This PCIMR includes an analysis and summary of the site inspections, repairs and maintenance, meteorological information, and soil moisture monitoring data obtained at CAU 110 for the period July 2007 through June 2008. Site inspections of the cover were performed quarterly to identify any significant changes to the site requiring action. The overall condition of the cover, perimeter fence, and use restriction (UR) warning signs was good. However, settling was observed that exceeded the action level as specified in Section VII.B.7 of the Hazardous Waste Permit Number NEV HW021 (Nevada Division of Environmental Protection, 2005). This permit states that cracks or settling greater than 15 centimeters (6 inches) deep that extend 1.0 meter (m) (3 feet [ft]) or more on the cover will be evaluated and repaired within 60 days of detection. Two areas of settling and cracks were observed on the south and east edges of the cover during the September 2007 inspection that exceeded the action level and required repair. The areas were repaired in October 2007. Additional settling and cracks were observed along the east side of the cover during the December 2007 inspection that exceeded the action level, and the area was repaired in January 2008. Significant animal burrows were also observed during the March 2008 inspection, and small mammal trapping and relocation was performed in April 2008. The semiannual subsidence surveys were performed in September 2007 and March 2008. No significant subsidence was observed in the survey data. Monument 5 shows the greatest amount of subsidence (-0.02 m [-0.08 ft] compared to the baseline survey of 2000). This amount is negligible and near the resolution of the survey instruments; it does not indicate that subsidence is occurring overall on the cover. Soil moisture results obtained to date indicate that the CAU 110 cover is performing well. Time Domain Reflectometry (TDR) data show regular changes in the shallow subsurface with significant rain events; however, major changes in volumetric moisture content (VMC) appear to be limited to 1.8 m (6 ft) below ground surface or shallower, depending on the location on the cover. At 2.4 m (8 ft) below the cover surface, TDR data show soil moisture content remained between 9 and 15 percent VMC, depending on the TDR location. The west portion of the cover tends to reflect a lower moisture content and less variability in annual fluctuations in moisture content at this depth. Results of soil moisture monitoring of the cover indicate that VMC at the compliance level (at 2.4 m [8 ft] below the cover surface) is approaching a steady state. If the moisture content at this level remains consistent with recent years, then a recommendation may be made for establishing compliance levels for future monitoring.

54 ENVIRONMENTAL SCIENCES↗

Thin Film Packaging Solutions for High Efficiency OLED Lighting Products

The objective of the 'Thin Film Packaging Solutions for High Efficiency OLED Lighting Products' project is to demonstrate thin film packaging solutions based on SiC hermetic coatings that, when applied to glass and plastic substrates, support OLED lighting devices by providing longer life with greater efficiency at lower cost than is currently available. Phase I Objective: Demonstrate thin film encapsulated working phosphorescent OLED devices on optical glass with lifetime of 1,000 hour life, CRI greater than 75, and 15 lm/W. Phase II Objective: Demonstrate thin film encapsulated working phosphorescent OLED devices on plastic or glass composite with 25 lm/W, 5,000 hours life, and CRI greater than 80. Phase III Objective: Demonstrate 2 x 2 ft{sup 2} thin film encapsulated working phosphorescent OLED with 40 lm/W, 10,000 hour life, and CRI greater than 85. This report details the efforts of Phase III (Budget Period Three), a fourteen month collaborative effort that focused on optimization of high-efficiency phosphorescent OLED devices and thin-film encapsulation of said devices. The report further details the conclusions and recommendations of the project team that have foundation in all three budget periods for the program. During the conduct of the Thin Film Packaging Solutions for High Efficiency OLED Lighting Products program, including budget period three, the project team completed and delivered the following achievements: (1) a three-year marketing effort that characterized the near-term and longer-term OLED market, identified customer and consumer lighting needs, and suggested prototype product concepts and niche OLED applications lighting that will give rise to broader market acceptance as a source for wide area illumination and energy conservation; (2) a thin film encapsulation technology with a lifetime of nearly 15,000 hours, tested by calcium coupons, while stored at 16 C and 40% relative humidity ('RH'). This encapsulation technology was characterized as having less than 10% change in transmission during the 15,000 hour test period; (3) demonstrated thin film encapsulation of a phosphorescent OLED device with 1,500 hours of lifetime at 60 C and 80% RH; (4) demonstrated that a thin film laminate encapsulation, in addition to the direct thin film deposition process, of a polymer OLED device was another feasible packaging strategy for OLED lighting. The thin film laminate strategy was developed to mitigate defects, demonstrate roll-to-roll process capability for high volume throughput (reduce costs) and to support a potential commercial pathway that is less dependent upon integrated manufacturing since the laminate could be sold as a rolled good; (5) demonstrated that low cost 'blue' glass substrates could be coated with a siloxane barrier layer for planarization and ion-protection and used in the fabrication of a polymer OLED lighting device. This study further demonstrated that the substrate cost has potential for huge cost reductions from the white borosilicate glass substrate currently used by the OLED lighting industry; (6) delivered four-square feet of white phosphorescent OLED technology, including novel high efficiency devices with 82 CRI, greater than 50 lm/W efficiency, and more than 1,000 hours lifetime in a product concept model shelf; (7) presented and or published more than twenty internal studies (for private use), three external presentations (OLED workshop-for public use), and five technology-related external presentations (industry conferences-for public use); and (8) issued five patent applications, which are in various maturity stages at time of publication. Delivery of thin film encapsulated white phosphorescent OLED lighting technology remains a challenging technical achievement, and it seems that commercial availability of thin, bright, white OLED light that meets market requirements will continue to require research and development effort. However, there will be glass encapsulated white OLED lighting products commercialized in niche markets during the 2008 calendar year. This commercialization effort, the project team believes, will lead to increasing market attention and broader demand for more efficient, wide area general purpose white OLED lighting in the coming years.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗