At least 1,153 records · Page 64

Yahoo! Compute Coop (YCC). A Next-Generation Passive Cooling Design for Data Centers

The purpose of the Yahoo! Compute Coop (YCC) project is to research, design, build and implement a greenfield "efficient data factory" and to specifically demonstrate that the YCC concept is feasible for large facilities housing tens of thousands of heat-producing computing servers. The project scope for the Yahoo! Compute Coop technology includes: - Analyzing and implementing ways in which to drastically decrease energy consumption and waste output. - Analyzing the laws of thermodynamics and implementing naturally occurring environmental effects in order to maximize the "free-cooling" for large data center facilities. "Free cooling" is the direct usage of outside air to cool the servers vs. traditional "mechanical cooling" which is supplied by chillers or other Dx units. - Redesigning and simplifying building materials and methods. - Shortening and simplifying build-to-operate schedules while at the same time reducing initial build and operating costs. Selected for its favorable climate, the greenfield project site is located in Lockport, NY. Construction on the 9.0 MW critical load data center facility began in May 2009, with the fully operational facility deployed in September 2010. The relatively low initial build cost, compatibility with current server and network models, and the efficient use of power and water are all key features that make it a highly compatible and globally implementable design innovation for the data center industry. Yahoo! Compute Coop technology is designed to achieve 99.98% uptime availability. This integrated building design allows for free cooling 99% of the year via the building's unique shape and orientation, as well as server physical configuration.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Study on effect of geometrical configuration of radioactive source material to the radiation intensity of betavoltaic nuclear battery

Nuclear batteries have strategic applications and very high economic potential. One Important problem in application of nuclear betavoltaic battery is its low efficiency. Current efficiency of betavoltaic nuclear battery reaches only arround 2%. One aspect that can influence the efficiency of betavoltaic nuclear battery is the geometrical configuration of radioactive source. In this study we discuss the effect of geometrical configuration of radioactive source material to the radiation intensity in betavoltaic nuclear battery system. received by the detector. By obtaining the optimum configurations, the optimum usage of radioactive materials can be determined. Various geometrical configurations of radioactive source material are simulated. It is obtained that usage of radioactive source will be optimum for circular configuration.

30 DIRECT ENERGY CONVERSION↗

Understanding Your Utility Bills: Natural Gas

As a fossil fuel NG is a colorless and odorless gas in its natural state and is one of the cleanest burning hydrocarbons. The factors that contribute to the popularity of natural gas in the US manufacturing sector include ease of availability, clean burning properties, market deregulation, and increased domestic production. Analyzing natural gas (NG) bills can sometimes pose unique problems. Learning to read your utility bills and understand why your utility charges different fees is critical in maximizing your cost savings through energy efficiency. A key to creating a baseline is collecting and analyzing natural gas utility data. Historical data from NG bills can identify trends and help to find the baseline usage for a manufacturing operation. This guide intends to help Better Plant Program partners in understanding natural gas bills and analyzing usage to reduce costs. The guide focuses on natural gas production and transportation, understanding key charges on bills, different rate structures, and saving opportunities. A fictitious worked out example in the final section demonstrates how readers could go about analyzing natural gas bills.

03 NATURAL GAS↗

Hydropower Infrastructure – LAkes, Reservoirs, and RIvers (HILARRI)

HILARRI is a database of links between major datasets of operational hydropower dams and powerplants, and inland water bodies. These connections are critical for conducting large-scale analysis of hydropower infrastructure and their associated natural and engineered water systems. Features include: – Dams from the National Inventory of Dams (2024) and the Global Reservoir and Dam Database (GRanD v1.3) – Hydropower plants from the Existing Hydropower Assets dataset (EHA 2024) These hydropower infrastructure features are linked to several major datasets that provide hydrologic and hydraulic information relevant for analysis of hydropower systems that includes the integral water resources. That information comes from: – Products from the National Hydrography Dataset (NHD) – NHDPlusV2 Medium Resolution river network flowlines, – NHD waterbodies (limited to lakes and reservoirs), – NHD Watershed Boundary Dataset (HUC12-level for the Conterminous United States (CONUS)) – NHD High Resolution waterbodies – HydroLAKES water bodies (lakes and reservoirs) – LAGOS-US lakes and reservoirs – EPA National Lakes Assessment (2007, 2012, 2017, and 2022) – The Reservoir Sedimentation Database (RESSED) Unique identifiers are used to facilitate joining to the original full datasets. For example, characteristics of NHD flowlines such as estimated average flow rate can be joined from the NHDPlusV2 dataset to a dam or power plant listed in HILARRI based on the ID field, “COMID”, that is common to both datasets. HILARRI only includes basic information about identifiers, location, and data quality or usage notes. It does not contain the attributes or time series data associated with these sites. The HILARRI dataset incorporates information from several datasets to facilitate more effective and accurate analysis of hydropower infrastructure and their associated waterbodies. For example, dams were checked against the most recent American Rivers Dam Removal Database to identify and flag facilities that may no longer exist. Additionally, dams that are listed multiple times in the NID are identified and flagged to avoid double-counting when analyzing and summarizing information. Other quality flags include certainty of operational hydropower (i.e., if one or more datasets indicates hydropower at a particular location), whether an associated water body is accurate or composed of multiple polygons, or whether there is a known issue with reported characteristics in one of the underlying datasets. These additional data flags are designed to increase confidence in data usage for individual to large-scale analyses.

13 HYDRO ENERGY↗

NREL RSF Measured Data 2011

Modern buildings are complex energy systems that must be controlled for energy efficiency. The Research Support Facility (RSF) at the National Renewable Energy Laboratory (NREL) has hundreds of controllers -- computers that communicate with the building's various control systems -- to control the building based on tens of thousands of variables and sensor points. These control strategies were designed for the RSF's systems to efficiently support research activities. Many events that affect energy use cannot be reliably predicted, but certain decisions (such as control strategies) must be made ahead of time. NREL researchers modeled the RSF systems to predict how they might perform. They then monitor these systems to understand how they are actually performing and reacting to the dynamic conditions of weather, occupancy, and maintenance. This submission includes the Measured Energy Data from the RSF Systems Model. The data includes a csv with measured data from NREL's Research and Support Facility (RSF) for 2011. The dataset contains hourly data for: Total Cooling (kW)- Total Heating (kW)- Total Mechanical (kW)- Total Lighting (kW)- Total Plug Loads (kW)- Total Data Center (kW)- Total Building (kW)- PV (kW)- Building Net (kW). Energy Model data and Weather data related to the RSF Systems Model can be found in the "Related Datasets" section of this submission.

2011↗

Fuel-Optimal Trajectories in a Planet-Moon Environment Using Multiple Gravity Assists

For low energy spacecraft trajectories such as multi-moon orbiters for the Jupiter system, multiple gravity assists by moons could be used in conjunction with ballistic capture to drastically decrease fuel usage. In this paper, we outline a procedure to obtain a family of zero-fuel multi-moon orbiter trajectories, using a family of Keplerian maps derived by the first author previously. The maps capture well the dynamics of the full equations of motion; the phase space contains a connected chaotic zone where intersections between unstable resonant orbit manifolds provide the template for lanes of fast migration between orbits of different semimajor axes. Patched three body approach is used and the four body problem is broken down into two three-body problems, and the search space is considerably reduced by the use of properties of the Keplerian maps. We also introduce the notion of Switching Region where the perturbations due to the two perturbing moons are of comparable strength, and which separates the domains of applicability of the corresponding two Keplerian maps.

Ross, Shane D.↗

Hybrid Electric MC-12 Ground Testing Plan Chapter

In the commercial aviation world, hybrid/electric propulsion is a promising technology for fuel, emissions, and noise reduction in support of the challenging goals established by 2050 EU Flightpath/SRIA, NASA ARMD Strategic Implementation Plan, and the US Air Force ATTAM programs. Ongoing results indicate operational benefits are possible in those three technical areas. Considering military applications, hybrid/electric propulsion may yield further significant improvements by enabling new, unorthodox mission capabilities. Potential benefits are expected in the areas of vehicle signature reduction (lower noise, lower exhaust signature), usage in enhanced flight environments, minimized human-in-the-loop workload by offering a platform compatible with future goals of autonomous operations facilitation, maintenance cost reductions, and performance burst/dash energy. Additional synergies are likely when used in conjunction with energy weapons. Some potential areas of mutual interest could include, dusty operations capability, remote supply capability, extended surveillance, dispatch able power, fuel-flexible vehicles, and autonomous rescue equipment. Many of the key technologies that have been demonstrated in ground operation must now be qualified for altitude conditions. We expect to have many flight qualified powertrain systems over the next decade for military planners to choose from for new future battlefield capability. This requires new flight-weight and flight-efficient powertrain components, fault tolerant power management, and electromagnetic interference mitigation technologies. Moreover, initial studies indicate some combination of ambient and cryogenic thermal management and relatively high bus voltages when compared to state of practice will be required to achieve a net system benefit. Developing all these powertrain technologies within a realistic aircraft architectural geometry and under realistic operational conditions requires a unique electric aircraft test bed. The MC-12 surveillance aircraft is an ideal military aircraft for demonstrating some of the benefits of incorporating hybrid electric propulsion. This report details an approach for full-scale ground-based altitude testing the hybrid electric MC-12 powertrain through a full flight profile.

military electric aircraft propulsion↗

Evaluating the Computational Requirements of using SVM software to train Data-Intensive Problems

Support vector machine (SVM) technology is a growing class of computational algorithms for solving classification problems using supervised learning. There are many freely available SVM codes with implementations of varying granularity in the core optimization task. The performance of SVM implementations is related to four key elements; (1) the size and dimension of the data set on which they are operating, (2) the granularity of their core SVM optimization implementation, (3) the kernel transformation applied to the data, and the (4) underlying hardware on which the implementation is running. To assess the performance of different SVM implementations, several freely available codes representing the spectrum of optimization granularity were built on a variety of hardware—two linux clusters, and a shared memory machine. Binary classifiers were trained on datasets of varying size containing anywhere from a few hundred to over 50,000 vectors. Performance of the methods was measured in terms of wall-clock time for training, statistical quality of the resulting classifier, hardware performance (memory footprint, memory bandwidth, floating point unit usage, I/O bandwidth, and instruction stalls), robustness and portability.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Community Solar and Community Solar+Storage: A Roadmap of Barriers and Solutions for Commercial Systems in NYC

Sustainable CUNY worked with decision makers and subject matter experts (SME's) to identify the barriers to and solutions for advancing commercial Community Solar (CS) and CS+Storage (CS+S) in urban areas. This roadmap captures the key challenges and solutions identified by New York City (NYC) stakeholders, including the Real Estate Board of New York (REBNY), through a collaborative process. Solar, as well as storage, are among the fastest growing energy segments in the United States, with CS, also known as Community Distributed Generation (CDG), gaining popularity with those who may not own or have access to a viable roof. Urban areas like NYC, which have a large population of renters, are particularly well suited for CS projects where credits from the power produced by a large remote installation are offered on a subscription basis to residents or businesses in the community. However, CS and CS+S projects have stalled at the doorstep of many cities. Host site owners, particularly those with large rooftops, have been slow to commit to installing CS due to competing rooftop usage and programs, limited knowledge about incentives, lack of economic data, and a complicated implementation process.

14 SOLAR ENERGY↗

Dual energy exposure control (DEEC) for computed tomography: Algorithm and simulation study

DECT means acquiring the same object at two different energies, respectively two different tube voltages U{sub 1} and U{sub 2}. The raw data q{sub 1} and q{sub 2} undergo a decomposition process of type p=p(q{sub 1},q{sub 2}). The raw data p are reconstructed to obtain monochromatic images of the attenuation {mu}, of the object density {rho}, or of a specific material distribution. Recent advances in DECT focus on noise reduction techniques [S. Richard and J. H. Siewerdsen, Med. Phys. 35(2), 586-600 (2008)] and enable high performance DECT such as lung nodule detection [Shkumat et al., Med. Phys. 35(2), 629-632 (2008)]. Given p and a raw data-based projection-wise patient dose estimation D({alpha}) the authors determine the optimal tube current curves I{sub 1}({alpha}) and I{sub 2}({alpha}), with {alpha} being the view angle, which minimizes image noise for a given patient dose level. DEEC can perform online; I{sub 1}({alpha}) and I{sub 2}({alpha}) can be determined during the scan. Simulation studies using semianthropomorphic phantom data were carried out. In particular, functions p that generate {mu}-images and density images were evaluated. Image quality was compared to standard scans at U{sub 0}=120 kV (clinical CT) and U{sub 0}=45 kV (micro-CT) that were taken at the same dose level (D{sub 0}=D{sub 1}+D{sub 2}) and identical spatial resolution. Appropriate choice of p(q{sub 1},q{sub 2}) allows to obtain {mu}-images that show fewer artifacts and yield image noise levels comparable to the noise of the standard scan. The authors compared the standard scan to {mu}-images at 70 keV, which is the effective energy used in clinical CT, and found optimal results with {mu}-images at 25 keV for micro-CT. Nonoptimal choice of the decomposition function will, however, significantly increase image noise. In particular {mu}-images at 511 keV, as needed for PET/CT attenuation correction, exhibit more than twice as much image noise as the standard scan. With DEEC, which guarantees best dose usage possible, monochromatic images are generated with only slightly increased noise levels at the same dose compared to a standard scan. The benefit of significantly decreased artifacts appears to allow using DEEC-generated monochromatic images in daily routine. Furthermore, DEEC is not restricted to DECT and the inherent tube current modulation algorithm may also be applied to single energy CT.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Techno-Economic Analysis of BEV Service Providers Offering Battery Swapping Services: Preprint

Battery electric vehicles (BEVs) offer the potential to reduce both oil imports and greenhouse gas emissions, but high upfront costs, battery-limited vehicle range, and concern over high battery replacement costs may discourage potential buyers. A subscription model in which a service provider owns the battery and supplies access to battery swapping infrastructure could reduce upfront and replacement costs for batteries with a predictable monthly fee, while expanding BEV range. Assessing the costs and benefits of such a proposal are complicated by many factors, including customer drive patterns, the amount of required infrastructure, battery life, etc. The National Renewable Energy Laboratory has applied its Battery Ownership Model to compare the economics and utility of BEV battery swapping service plan options to more traditional direct ownership options. Our evaluation process followed four steps: (1) identifying drive patterns best suited to battery swapping service plans, (2) modeling service usage statistics for the selected drive patterns, (3) calculating the cost-of-service plan options, and (4) evaluating the economics of individual drivers under realistically priced service plans. A service plan option can be more cost-effective than direct ownership for drivers who wish to operate a BEV as their primary vehicle where alternative options for travel beyond the single-charge range are expensive, and a full-coverage-yet-cost-effective regional infrastructure network can be deployed. However, when assumed cost of gasoline, tax structure, and absence of purchase incentives are factored in, our calculations show the service plan BEV is rarely more cost-effective than direct ownership of a conventional vehicle.

25 ENERGY STORAGE↗

Potentials for Platooning in U.S. Highway Freight Transport

Smart technologies enabling connection among vehicles and between vehicles and infrastructure as well as vehicle automation to assist human operators are receiving significant attention as a means for improving road transportation systems by reducing fuel consumption - and related emissions - while also providing additional benefits through improving overall traffic safety and efficiency. For truck applications, which are currently responsible for nearly three-quarters of the total U.S. freight energy use and greenhouse gas (GHG) emissions, platooning has been identified as an early feature for connected and automated vehicles (CAVs) that could provide significant fuel savings and improved traffic safety and efficiency without radical design or technology changes compared to existing vehicles. A statistical analysis was performed based on a large collection of real-world U.S. truck usage data to estimate the fraction of total miles that are technically suitable for platooning. In particular, our analysis focuses on estimating 'platoonable' mileage based on overall highway vehicle use and prolonged high-velocity traveling, and established that about 65% of the total miles driven by combination trucks from this data sample could be driven in platoon formation, leading to a 4% reduction in total truck fuel consumption. This technical potential for 'platoonable' miles in the United States provides an upper bound for scenario analysis considering fleet willingness and convenience to platoon as an estimate of overall benefits of early adoption of connected and automated vehicle technologies. A benefit analysis is proposed to assess the overall potential for energy savings and emissions mitigation by widespread implementation of highway platooning for trucks.

30 DIRECT ENERGY CONVERSION↗

Active SOC Balancing for a Multi-Chemistry Battery Pack with Reduced Number of Converters

In energy storage systems using second-life or multi-chemistry cells, an active state of charge (SOC) balancing system can prolong pack life and enhance performance by utilizing the healthier cells more than those which are heavily degraded. However, the high cost of the active balancing system, particularly in converter-based solutions, prevents their widespread usage. Considering this, existing research has proposed numerous balancing systems utilizing only one converter. However, such systems may compromise the balancing speed too much. Therefore, this work proposes two active balancing systems with a reduced number of converters for 14-16 series-connected cells. One system uses two converters for direct cell-to-cell balancing. The other uses a time-multiplexed approach to exchange energy via an auxiliary low-voltage (LV) bus using four converters. The proposed balancing systems are compared to two baseline systems, a single converter cell-to-cell balancing system, and a 14 converter balancing system with an auxiliary LV bus.

battery pack↗

Active SOC Balancing for a Multi-Chemistry Battery Pack with Reduced Number of Converters: Preprint

In energy storage systems using second-life or multi-chemistry cells, an active state of charge (SOC) balancing system can prolong pack life and enhance performance by utilizing the healthier cells more than those which are heavily degraded. However, the high cost of the active balancing system, particularly in converter-based solutions, prevents their widespread usage. Considering this, existing research has proposed numerous balancing systems utilizing only one converter. However, such systems may compromise the balancing speed too much. Therefore, this work proposes two active balancing systems with a reduced number of converters for 14-16 series-connected cells. One system uses two converters for direct cell-to-cell balancing. The other uses a time-multiplexed approach to exchange energy via an auxiliary low-voltage (LV) bus using four converters. The proposed balancing systems are compared to two baseline systems, a single converter cell-to-cell balancing system, and a 14 converter balancing system with an auxiliary LV bus.

battery pack↗

Multi-objective optimization of sustainable aviation fuel production pathways in the U.S. Corn Belt

As a potential source of low-carbon transportation energy, biofuels offer certain advantages over vehicle electrification (e.g., lower societal vulnerability to grid failures, and improved range of sustainable aviation), but also several challenges, including cost, carbon intensity, and land usage. There are also well-founded concerns that biofuel supply chains could be disrupted if extreme weather events impact feedstock yields. In this paper, we explore the use of multi-objective optimization to identify biofuel production pathways that balance cost, greenhouse gas emissions, and supply vulnerability to extreme weather. We compare the use of three different many-objective evolutionary algorithms and linear programming in optimizing biomass cultivation decisions in the U.S. Corn Belt under weather uncertainty using historical, modeled, and synthetic yield data. We consider four feedstock choices (corn, soy, switchgrass, and algae) with two land types (agricultural and marginal lands) and evaluate decisions using three alternative spatial resolutions (ranging from the USDA agricultural district level to the state level). Results show that feedstock choice is the primary driver of objective performance (i.e., the position and shape of 3D, approximate Pareto frontiers). Spatial diversification is a less effective tool in reducing exposure to weather-caused drops in crop yield.

09 BIOMASS FUELS↗

Electricity use in big area additive manufacturing of fiber-reinforced polymer composites

In recent years, additive manufacturing (AM), especially large-format additive manufacturing (LFAM), has gained momentum in the manufacturing industry. While LFAM offers benefits over conventional manufacturing processes, such as minimizing material waste and providing vast geometric freedom, assessing its sustainability remains challenging due to limited data, particularly on energy consumption. Most existing data pertain to small-scale or desktop AM and are not directly applicable to LFAM. In this study, we conducted real-time measurements of electricity usage for a type of LFAM known as big area additive manufacturing (BAAM), which typically uses fiber-reinforced polymer pellets as feedstock. We collected electricity usage data from fifteen printing jobs over two months in an industrial production setting. These data fill the existing gap and can be reused to enhance the community’s understanding of LFAM electricity usage, support further research, and promote sustainable development in advanced manufacturing technologies.

ecology↗