Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “ELECTRICITY”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,153 records · Page 64

System and method for detecting false data injection in electrical substations

Unique systems, methods, techniques and apparatuses of a substation phasor data concentrator (ssPDC) is disclosed herein. One exemplary embodiment is a method for operating an electrical substation including a merging unit (MU), a phasor measurement unit (PMU), and a substation phasor data concentrator (ssPDC). The method includes receiving, with the MU and the PMU, input information corresponding to a set of electrical characteristics of the electrical substation; measuring, with the MU, the input information; measuring, with the PMU, the input information; a and estimating, with the ssPDC, electrical characteristics of the electrical substation using the received false measurement and the one of the MU measurement and the PMU measurement, determining in substantially real time the false measurement does not correspond to the set of electrical characteristics using the estimated electric characteristics, and replacing the false measurement with the received the one of the MU measurement and the PMU measurement.

Hong, Junho↗

ELECTRICAL BREAKDOWN STRENGTH AND AC WITHSTAND IN HARVESTED EPR INSULATIONS FOR NUCLEAR POWER PLANTS

While the operating voltages for some instrument and control (I&C) cables can be greater than 4 kV to operate pumps, controls, and provide auxiliary power, the operating voltage for most I&C cables is near 600 V. Although the electrical stress is not nearly as high in the insulation of these cables, an ac withstand two and one-half times greater than the operating voltage after a simulated design basis exposure (DBE) has been used in environmental qualification (EQ) to determine the ability of an insulation to meet a 40-year lifetime at an operating voltage. While multiple cable lengths greater than 10 feet are needed to replicate this EQ, systematic measurement of the electrical insulation strength in harvested cable insulations can be beneficial to better understand the remaining useful life of the insulation. This understanding can only be realized through systematic comparison to some level of DBE, and electrical insulation strength measurement can provide a baseline for comparison with other mechanical, chemical, and electrical characterizations that have been utilized. Accelerated aging of two types of ethylene propylene rubber (EPR) insulations from harvested cables was carried out, and the electrical breakdown strength and indenter modulus for both insulations were determined. Results showed that degradation of electrical breakdown strength occurred in only one type of BIW insulation and that this degradation did track with that measured by indenter modulus. The methodology for using Weibull statistics for electrical breakdown strength relative to time to failure is discussed.

Duckworth, Robert↗

The Modeling of Synfuel Production Process: ASPEN Model of FT production with electricity demand provided at LWR scale

Synfuels, or electro-fuels (e-fuels) have the unique potential to significantly reduce greenhouse gas (GHG) emissions across the transportation sector. This is especially true for applications with substantial payloads and daily miles traveled, such as long-haul heavy-duty vehicles, rail locomotives, marine vessels and aviation aircrafts that are challenging to directly electrify via battery or fuel cell powertrain technologies. Synfuels, or electro-diesel/electro-jet fuels, have similar properties with the incumbent petroleum fuels, compatible with current infrastructure but have much lower GHG emissions relative to the petroleum counterpart, because they utilize waste carbon dioxide (CO2) streams and green hydrogen (H2) sourced from electrolysis. To achieve substantial reductions in GHG emissions, electricity sources must be zero carbon or near-zero carbon, which is the case with solar, wind, hydro and nuclear power. Compared to the intermittency of solar, wind and hydro, nuclear energy provides a steady energy source. In addition, it’s advantageous for nuclear power to produce synfuels because it provides not only near-zero carbon electricity to displace grid electricity, but also near-zero carbon steam to displace carbon-intensive natural gas combustion for steam generation. The availability of electricity and steam also enables more efficient green hydrogen production by using high-temperature electrolysis. In this work, Argonne National Laboratory (ANL) models a synfuel production process via the Fischer- Tropsch (FT) reaction by using nuclear power to provide electricity and steam. In 2021, using ASPEN Plus software, ANL established a detailed process model of a stand-alone FT production facility, assuming feedstocks of pure CO2 and H2. This stand-alone model can be expanded to integrate H2 production from nuclear power via low-temperature and high-temperature electrolysis at light-water reactor (LWR) scale. This report summarizes the stand-alone ASPEN Plus model results with a detailed mass and energy analysis. Our modeled facility produces 351 MT/day (130,000 gal/day) of FT fuel (a mixture of naphtha, jet fuel, and diesel) by converting 223 MT/day of H2 and 2,387 MT/day of CO2. The FT fuel production energy efficiency is 58% and the carbon conversion efficiency (from CO2 to FT fuel) is 46%. The production of green hydrogen requires 390–470 MWe of electricity, which is compared with the capacity of an LWR plant. For the stand-alone FT process, the detailed energy demand (electricity and heat) is summarized in the table below. Based on the energy supply source and the required temperature, potential insertion points of nuclear energy are identified. Based on the potential nuclear energy utilization, this report discusses potential modification options for expanding the system boundary to integrate nuclear power use, for example on-site hydrogen production via water electrolysis. Modeling of the integrated system is conducted by closely working with ANL and Idaho National Laboratory (INL) collaborators to harmonize design parameters of nuclear plants and the FT production process.

Zang, Guiyan↗

Synchronized electric meter having an atomic clock

Smart electric meters configured to perform fast, time-synchronized electrical energy measurements at the consumer-level are disclosed herein. In some embodiments, a smart electric meter includes circuitry configured to measure an electrical value at a location of an end user in a power system. The smart electric meter can further include an atomic clock configured to output a timing signal, and a controller configured to receive (a) the measured electrical value from the circuitry and (b) the timing signal from the atomic clock. The controller can further (a) process the electrical value to generate meter data and (b) generate a time tag based on the timing signal. Then, the controller can associate the time tag with the meter data to generate time-tagged meter data.

Min, Liang↗

Electrical and Thermal Load Impacts of Three District Heating and Cooling Designs for an Existing Community in Washington, DC

District energy systems that provide building heating and cooling are a promising option to provide low-cost, energy efficient heating and cooling solutions for communities. As some buildings move to electrified heating designs, there may be significant increases in electric grid demand, particularly in the winter. District energy systems may be able to help reduce these high electrical demands on the electric grid, while also providing decreased overall energy consumption with an increased flexibility in electrical energy usage. To evaluate and compare district options for district-based heating and cooling, an existing neighborhood of Washington, DC consisting of 35 existing buildings was selected as a case study. This study models and compares a fourth generation (4G) district heating and cooling systems that provide hot and chilled water from a central plant directly to each prosumer and a fifth generation (5G) district heating and cooling systems that provide near-ambient water via geothermal boreholes to interface with an energy transfer station with a heat pump at each prosumer. These district systems are compared against a baseline of the non-connected buildings with their self-contained and current HVAC systems. The neighborhood was selected as a good candidate for a district system for its diversity of loads (mix of different commercial and property types) and the availability of building characteristics. URBANopt District Energy Systems (DES) was used to model the buildings and create initial Modelica models for the district systems. Finally, the DES models were tuned and simulated in Dymola, and the outputs were post-processed for verification and to calculate the electrical and thermal grid impact metrics. This is the first documentation of this workflow and its complete analysis. The three designed systems are compared via their grid metrics including: total energy consumption, electrical demand peak loads, daily peak-to-valley ratios, and system ramping. A detailed discussion is provided about how each system impacts and interacts with the electric grid.

15 GEOTHERMAL ENERGY↗

An Advanced Decision Support Tool for Electricity Infrastructure Operations

Electricity infrastructure, as one of the most critical infrastructures in the U.S., plays an important role in modern societies. Its failure would lead to significant disruption of people’s lives, industry and commercial activities, and result in massive economic losses. Reliable operation of electricity infrastructure is an extremely challenging task because human operators need to consider thousands of possible configurations in near real-time to choose the best option and operate the network effectively. In today’s practice, electricity infrastructure operation is largely based on operators’ experience with very limited real-time decision support, resulting in inadequate management of complex predictions and the inability to anticipate, recognize, and respond to situations caused by human errors, natural disasters, or cyber attacks. Therefore, a systematic approach is needed to manage the complex operational paradigms and choose the best option in a near-real-time manner. This paper proposes an advanced decision support tool for electricity infrastructure operations. The tool has the functions of turning large amount of data into actionable information to help operators monitor power grid status in real time; performing trend analysis to indentify system trend at the regional level or system level to help the operator to foresee and discern emergencies, studying clustering analysis to assist operators to identify the relationships between system configurations and affected assets, and interactively evaluating the alternative remedial actions to aid operators to make effective and timely decisions. This tool can provide significant decision support on electricity infrastructure operations and lead to better reliability in power grids. This paper presents examples with actual electricity infrastructure data to demonstrate the capability of this tool.

54 ENVIRONMENTAL SCIENCES↗

Electric Field Characteristics of an Arc-Induction-Type DC Circuit Breaker Combined with a Magnet for Stability in the DC Power Grid

For stability in the direct current (DC) power grid, it is very important to limit the current of the fault section and to protect the system in the fault condition. That is the core technology of the DC power grid. This paper suggests characteristics and a limited range of the fault current for the new model as the significant protecting technology in the DC power grid. Such new model is the arc-induction-type DC circuit breaker (CB) combined with a magnet. The magnetic arc-induction-type direct-current circuit breaker (DCCB) consists of a neodymium magnet, an induction needle, and electrical contacts. During fault operation, the arc occurring between the contacts is induced to the induction needle. To increase the induction effect, Lorentz force is applied to blow the arc. A magnet was applied to reduce the initial fault current and to induce magnetic flux. The simulation data were analyzed using the Maxwell 3D software program. The electric field included the electric force and the electric charge. Therefore, it could analyze the arc as the electric field. The simulation was performed based on the preceding study on induction needle. As a result of the simulation, it was confirmed that the electric field value of the induction needle increased when the DCCB was combined with a magnet.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Simulation of radio emission from air showers in atmospheric electric fields

We study the effect of atmospheric electric fields on the radio pulse emitted by cos- mic ray air showers. Under fair weather conditions the dominant part of the radio emission is driven by the geomagnetic field. When the shower charges are accelerated and deflected in an electric field additional radiation is emitted. We simulate this effect with the Monte Carlo code REAS2, using CORSIKA-simulated showers as input. In both codes a routine has been implemented that treats the effect of the electric field on the shower particles. We find that the radio pulse is significantly altered in background fields of the order of ~100 V/cm and higher. Practically, this means that air showers passing through thunderstorms emit radio pulses that are not a reliable measure for the shower energy. Under other weather circumstances significant electric field effects are expected to occur rarely, but nimbostratus clouds can harbor fields that are large enough. In general, the contribution of the electric field to the radio pulse has polarization properties that are different from the geomagnetic pulse. In order to filter out radio pulses that have been affected by electric field effects, radio air shower experiments should keep weatherinformation and perform full polarization measurements of the radio signal.

79 ASTRONOMY AND ASTROPHYSICS↗

Deployment of CCS Technologies across the Load Curve for a Competitive Electricity Market as a Function of CO2 Emissions Permit Prices

Consistent with other published studies, the modelling presented here reveals that baseload power plants are the first aspects of the electricity sector to decarbonize and are essentially decarbonized once CO2 permit prices exceed a certain threshold ($90/ton CO2 in this study). The decarbonization of baseload electricity is met by significant expansions of nuclear power and renewable energy generation technologies as well as the application of carbon dioxide capture and storage (CCS) technologies applied to both coal and natural gas fired power plants. Relatively little attention has been paid thus far to whether intermediate and peaking units would respond the same way to a climate policy given the very different operational and economic context that these kinds of electricity generation units operate under. In this paper, the authors discuss key aspects of the load segmentation methodology used to imbed a varying electricity demand within the GCAM (a state-of-the-art Integrated Assessment Model) energy and economic modelling framework and present key results on the role CCS technologies could play in decarbonizng subpeak and peak generation (encompassing only the top 10% of the load) and under what conditions. To do this, the authors have modelled two hypothetical climate policies that require 50% and 80% reductions in US emissions from business as usual by the middle of this century. Intermediate electricity generation is virtually decarbonized once carbon prices exceed approximately $150/tonCO2. When CO2 permit prices exceed $160/tonCO2, natural gas power plants with CCS have roughly the same marketshare as conventional gas plants in serving subpeak loads. The penetration of CCS into peak load (upper 6% here) is minimal under the scenarios modeled here suggesting that CO2 emissions from this aspect of the U.S. electricity sector would persist well into the future even with stringent CO2 emission control policies in place.

01 COAL, LIGNITE, AND PEAT↗

Comparing total cost of ownership of battery electric vehicles and internal combustion engine vehicles

The technological advance of electrochemical energy storage and the electric powertrain has led to rapid growth in the deployment of electric vehicles. The high cost and the added weight of the batteries have limited the size (energy storage capacity) and, therefore, the driving range of these vehicles. However, consumers are steadily purchasing these vehicles because of the fast acceleration, quiet ride, and high energy efficiency. The higher pack-to-wheel efficiency and the lower energy cost per mile, as well as the lower expense for maintenance and repair, translate to operating savings over conventional vehicles. Here we compare battery electric vehicles with internal combustion engine vehicles based on the total cost of ownership. It is seen that the higher initial cost of electric vehicles can be recovered in as little as 5 years. This is especially true for electric vehicles with shorter driving ranges. Specifically, a vehicle with an electric driving range under 200 miles may achieve cost parity with an equivalent internal combustion engine vehicle in 8 years or less.

33 ADVANCED PROPULSION SYSTEMS↗

Light-Dependent Impedance Spectra and Transient Photoconductivity in a Ruddlesden–Popper 2D Lead–Halide Perovskite Revealed by Electrical Scanned Probe Microscopy and Accompanying Theory

Electric force microscopy was used to record the light-dependent impedance spectrum and the probe transient photoconductivity of a film of butylammonium lead iodide, BA 2 PbI 4 , a 2D Ruddlesden–Popper perovskite semiconductor. The impedance spectrum of BA 2 PbI 4 showed modest changes as the illumination intensity was varied up to 1400 mW cm –2 , in contrast with the comparatively dramatic changes seen for 3D lead–halide perovskites under similar conditions. BA 2 PbI 4 ’s light-induced conductivity had a rise time and decay time of ~100 μs, 10 4 slower than expected from direct electron–hole recombination yet 10 5 faster than the conductivity-recovery times recently observed in 3D lead–halide perovskites and attributed to the relaxation of photogenerated vacancies. What sample properties are probed by electric force microscope measurements remains an open question. A Lagrangian-mechanics treatment of the electric force microscope experiment was recently introduced by Dwyer, Harrell, and Marohn which enabled the calculation of steady-state electric force microscope signals in terms of a complex sample impedance. Here this impedance treatment of the tip–sample interaction is extended, through the introduction of a time-dependent transfer function, to include time-resolved electrical scanned probe measurements. Here, it is shown that the signal in a phase-kick electric force microscope experiment, and therefore also the signal in a time-resolved electrostatic force microscope experiment, can be written explicitly in terms of the sample’s time-dependent resistance (i.e., conductivity).

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Hysteretic Responses of Skyrmion Lattices to Electric Fields in Magnetoelectric Cu 2 OSeO 3

Electric field control of topologically nontrivial magnetic textures, such as skyrmions, provides a paradigm shift for future spintronics beyond current silicon-based technology. While significant progress has been made by X-ray and neutron scattering studies, direct observation of such nanoscale spin structures and their dynamics driven by external electric fields remains a challenge to understand underlying mechanisms and harness functionalities. Here, using Lorentz transmission electron microscopy combined with in situ electric and magnetic fields at liquid helium temperatures, we report the crystallographic-orientation dependent skyrmion responses to electric fields in thin slabs of magnetoelectric Cu 2 OSeO 3 . We show electric fields not only stabilize the hexagonally packed skyrmion lattices in the entire sample in a hysteretic manner but also induce the rotation of their reciprocal vector discretely by 30°. Furthermore, the nonvolatile and energy-efficient skyrmion-lattice control by electric fields demonstrated in this work provides an important foundation for designing skyrmion-based qubits and memory devices.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Fluoride-modified electrical properties of lead borate glasses and electrochemically induced crystallization in the glassy state

Lead fluoroborate glasses were prepared by the melt-quenching technique and characterized in terms of (micro)structural and electrical properties. The study was conducted on as prepared as well as temperature- and/or electric field-treated glass samples. The results show that, in the as-prepared glassy-state materials, electrical conductivity improved with increasing the PbF{sub 2} glass content. This result involves both an increase of the fluoride charge carrier density and, especially, a decrease of the activation energy from a glass structure expansion improving charge carrier mobility. Moreover, for the electric field-treated glass samples, surface crystallization was observed even below the glass transition temperature. As previously proposed in literature, and shown here, the occurrence of this phenomenon arose from an electrochemically induced redox reaction at the electrodes, followed by crystallite nucleation. Once nucleated, growth of {beta}-PbF{sub 2} crystallites, with the indication of incorporating reduced lead ions (Pb{sup +}), was both (micro)structurally and electrically detectable and analyzed. The overall crystallization-associated features observed here adapt well with the floppy-rigid model that has been proposed to further complete the original continuous-random-network model by Zachariasen for closely addressing not only glasses' structure but also crystallization mechanism. Finally, the crystallization-modified kinetic picture of the glasses' electrical properties, through application of polarization/depolarization measurements originally combined with impedance spectroscopy, was extensively explored.

36 MATERIALS SCIENCE↗

Traveling electric field probed by a fine particle above voltage-modulated strips in a striped electrode device

It is described that the distribution of the horizontal electric field above a striped electrode can be inferred from the trajectory of a single fine particle with known mass and diameter. The striped electrode consists of 100 segmented stainless steel strips, each electrically insulated. A traveling periodic potential profile is produced above the striped electrode by modulating the voltage signals on the strips. When the voltage modulation is on, the fine particle, which is originally levitated in the sheath region above the striped electrode, experiences a periodic oscillation along both the vertical and the horizontal directions because of the periodic electric force arising from the modulation voltages. Tracking the motion of the fine particles, the electric force is obtained from the momentum equation including the gravity and the neutral gas friction. With the particle charge estimated by the vertical oscillation method, the electric field can be derived. The horizontal electric field obtained by this method is in agreement with the result predicted by a collisional particle-in-cell simulation.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Kinetic model of electric potentials in localized collisionless plasma structures under steady quasi-gyrotropic conditions

Localized plasma structures, such as thin current sheets, generally are associated with localized magnetic and electric fields. In space plasmas localized electric fields not only play an important role for particle dynamics and acceleration but may also have significant consequences on larger scales, e.g., through magnetic reconnection. Also, it has been suggested that localized electric fields generated in the magnetosphere are directly connected with quasi-steady auroral arcs. In this context, we present a two-dimensional model based on Vlasov theory that provides the electric potential for a large class of given magnetic field profiles. The model uses an expansion for small deviation from gyrotropy and besides quasineutrality it assumes that electrons and ions have the same number of particles with their generalized gyrocenter on any given magnetic field line. Specializing to one dimension, a detailed discussion concentrates on the electric potential shapes (such as 'U' or 'S' shapes) associated with magnetic dips, bumps, and steps. Then, it is investigated how the model responds to quasi-steady evolution of the plasma. Finally, the model proves useful in the interpretation of the electric potentials taken from two existing particle simulations.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Structures, electrical properties, and leakage current behaviors of un-doped and Mn-doped lead-free ferroelectric K{sub 0.5}Na{sub 0.5}NbO{sub 3} films

Lead-free ferroelectric un-doped and doped K{sub 0.5}Na{sub 0.5}NbO{sub 3} (KNN) films with different amounts of manganese (Mn) were prepared by a chemical solution deposition method. The thicknesses of all films are about 1.6 μm. Their phase, microstructure, leakage current behavior, and electrical properties were investigated. With increasing the amounts of Mn, the crystallinity became worse. Fortunately, the electrical properties were improved due to the decreased leakage current density after Mn-doping. The study on leakage behaviors shows that the dominant conduction mechanism at low electric field in the un-doped KNN film is ohmic mode and that at high electric field is space-charge-limited and Pool-Frenkel emission. After Mn doping, the dominant conduction mechanism at high electric field of KNN films changed single space-charge-limited. However, the introduction of higher amount of Mn into the KNN film would lead to a changed conduction mechanism from space-charge-limited to ohmic mode. Consequently, there exists an optimal amount of Mn doping of 2.0 mol. %. The 2.0 mol. % Mn doped KNN film shows the lowest leakage current density and the best electrical properties. With the secondary ion mass spectroscopies and x-ray photoelectron spectroscopy analyses, the homogeneous distribution in the KNN films and entrance of Mn element in the lattice of KNN perovskite structure were also confirmed.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Multiwalled carbon nanotube/polydimethylsiloxane composite films as high performance flexible electric heating elements

High performance elastomeric electric heating elements were prepared by incorporating various contents of pristine multiwalled carbon nanotube (MWCNT) in polydimethylsiloxane (PDMS) matrix by using an efficient solution-casting and curing technique. The pristine MWCNTs were identified to be uniformly dispersed in the PDMS matrix and the electrical percolation of MWCNTs was evaluated to be at ∼0.27 wt. %, where the electrical resistivity of the MWCNT/PDMS composite films dropped remarkably. Accordingly, the composite films with higher MWCNT contents above 0.3 wt. % exhibit excellent electric heating performance in terms of temperature response rapidity and electric energy efficiency at constant applied voltages. In addition, the composite films, which were thermally stable up to 250 °C, showed excellent heating-cooling cyclic performance, which was associated with operational stability in actual electric heating applications.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Synthesis of zirconium oxynitride in air under DC electric fields

We synthesized zirconium oxynitride from yttria-stabilized zirconia (YSZ) in air by applying DC electric fields that produced a controlled electric current in the specimen. When YSZ was heated under an applied DC electric field, the electric current of the specimen steeply increased at a critical temperature, called a flash event, during flash sintering. By keeping the electric current of the specimen constant during the flash event and then holding the specimen at the critical temperature, YSZ was transformed into zirconium oxynitride under the optimal conditions of 50 V/cm, 500 mA, and 1000 °C. We confirmed that zirconium oxynitride formed using high-resolution transmission electron microscopy, electron energy-loss spectroscopy, and energy-dispersive spectrometry. To convert oxides to nitrides, reducing conditions are necessary to form excess oxygen vacancies. Our technique produced the strong reducing conditions necessary to form nitrides from the oxides by delivering a controlled electric current to the specimen.

36 MATERIALS SCIENCE↗