Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Decoder”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,153 records · Page 64

Deep learning multiphysics network for imaging CO 2 saturation and estimating uncertainty in geological carbon storage

Multiphysics inversion exploits different types of geophysical data that often complement each other and aims to improve overall imaging resolution and reduce uncertainties in geophysical interpretation. Despite the advantages, traditional multiphysics inversion is challenging because it requires a large amount of computational time and intensive human interactions for preprocessing data and finding trade-off parameters. These issues make it nearly impossible for traditional multiphysics inversion to be applied as a real-time monitoring tool for geological carbon storage. In this paper, we present a deep learning (DL) multiphysics network for imaging CO 2 saturation in real time. The multiphysics network consists of three encoders for analysing seismic, electromagnetic and gravity data and shares one decoder for combining imaging capabilities of the different geophysical data for better predicting CO 2 saturation. The network is trained on pairs of CO 2 label models and multiphysics data so that it can directly image CO 2 saturation. Here we use the bootstrap aggregating method to enhance the imaging accuracy and estimate uncertainties associated with CO 2 saturation images. Using realistic CO 2 label models and multiphysics data derived from the Kimberlina CO 2 storage model, we evaluate the performance of the deep learning multiphysics network and compare its imaging results to those from the deep learning single-physics networks. Our modelling experiments show that the deep learning multiphysics network for seismic, electromagnetic, and gravity data not only improves the imaging accuracy but also reduces uncertainties associated with CO 2 saturation images. Our results also suggest that the deep learning multiphysics network for the non-seismic data (i.e., electromagnetic and gravity) can be used as an effective low-cost monitoring tool in between regular seismic monitoring.

58 GEOSCIENCES↗

Time will tell: A longitudinal investigation of brain-behavior relationships during reading development

ERPs are a powerful tool for the study of reading, as they are both temporally precise and functionally specific. These are essential characteristics for studying a process that unfolds rapidly and consists of multiple, interactive subprocesses. In work with adults, clear, specific models exist linking components of the ERP with individual subprocesses of reading including orthographic decoding, phonological processing, and semantic access (e.g., Grainger & Holcomb, 2009). The relationships between ERP components and reading subprocesses are less clear in development; here, we address two questions regarding these relationships. First, we ask whether there are ERP markers that predict future reading behaviors across a longitudinal year. Second, we ask whether any relationships observed between ERP components and reading behavior across time map onto the better-established relationships between ERPs and reading subprocesses in adults. To address these questions, we acquired ERPs from children engaging in a silent reading task and then, a year later, collected behavioral assessments of their reading ability. Finally, we find that ERPs collected in Year 1 do predict reading behaviors a year later. Further, we find that these relationships do conform, at least to some extent, to relationships between ERP components and reading subprocesses observed in adults, with, for example, N250 amplitude in Year 1 predicting phonological awareness in Year 2, and N400 amplitude in Year 1 predicting vocabulary in Year 2.

60 APPLIED LIFE SCIENCES↗

An automated workflow that generates atom mappings for large‐scale metabolic models and its application to Arabidopsis thaliana

SUMMARY Quantification of reaction fluxes of metabolic networks can help us understand how the integration of different metabolic pathways determines cellular functions. Yet, intracellular fluxes cannot be measured directly but are estimated with metabolic flux analysis (MFA), which relies on the patterns of isotope labeling of metabolites in the network. The application of MFA also requires a stoichiometric model with atom mappings that are currently not available for the majority of large‐scale metabolic network models, particularly of plants. While automated approaches such as the Reaction Decoder Toolkit (RDT) can produce atom mappings for individual reactions, tracing the flow of individual atoms of the entire reactions across a metabolic model remains challenging. Here we establish an automated workflow to obtain reliable atom mappings for large‐scale metabolic models by refining the outcome of RDT, and apply the workflow to metabolic models of Arabidopsis thaliana . We demonstrate the accuracy of RDT through a comparative analysis with atom mappings from a large database of biochemical reactions, MetaCyc. We further show the utility of our automated workflow by simulating 15 N isotope enrichment and identifying nitrogen (N)‐containing metabolites which show enrichment patterns that are informative for flux estimation in future 15 N‐MFA studies of A. thaliana . The automated workflow established in this study can be readily expanded to other species for which metabolic models have been established and the resulting atom mappings will facilitate MFA and graph‐theoretic structural analyses with large‐scale metabolic networks.

59 BASIC BIOLOGICAL SCIENCES↗

A New Evaluation Metric for Demand Response-Driven Real-Time Price Prediction Towards Sustainable Manufacturing

Abstract The increasing industry energy demand highlights the urgency of demand response management, while the emerging smart manufacturing technologies pave the way for the implementation of real-time price (RTP)-based demand response management towards sustainable manufacturing. The demand response management requires scheduling of manufacturing systems based on RTP predictions, and thus the prediction quality can directly alter the effectiveness of demand response. However, since the general price prediction algorithms and prediction evaluation metrics are not specifically designed for RTP in demand response problems, a good RTP prediction obtained and evaluated by these algorithms and metrics may not be suitable for demand response scheduling. Therefore, in this study, the relationships between the effectiveness of demand response for manufacturing systems and evaluation results from six commonly used metrics are investigated. Meanwhile, a new metric called k-peak distance (KPD), considering the characteristics of the demand response problem, is proposed and compared with the other six metrics. Furthermore, an encoder-decoder long short-term memory recurrent neural network with KPD is proposed to provide better RTP prediction for manufacturing demand response problems. The case studies indicate that the proposed KPD metric shows a 1.8–3.6 times higher correlation with the demand response effectiveness compared to the other metrics. In addition, the production schedule based on the RTP prediction obtained from the proposed algorithm can improve the effectiveness of demand response by 23.4% on average.

Engineering↗

A Variational Autoencoder Model Toward Molecular Structure Representation Learning of Fuels

Here, in this work, a Variational Autoencoder (VAE)-based data-driven modeling framework is developed with the overarching goal of enabling fuel design. The VAE model is trained on a large dataset with several chemical species to learn a compressed latent space molecular representation. Chemical structure in the form of Simplified Molecular Input Line Entry System (SMILES) string is fed as input, encoded into the VAE latent space, and decoded back to the SMILES string using Long Short-Term Memory (LSTM) networks. Complexities of the VAE training loss function are thoroughly examined by varying the weightage (beta (𝜷) parameter) of the latent space regularization term, thereby assessing the balance between reconstruction accuracy and validity, and focusing on both accurate molecular structure reconstruction and latent space consistency. Two different strategies for 𝜷 variation are evaluated: linear annealing and cyclic annealing. In addition, the impact of total correlation adjustment and hierarchical priors is also studied with regard to the balance between reconstruction fidelity and latent space regularization, and potential issues such as posterior collapse, over-regularization, and poor disentanglement of latent variables. Overall, the best performance of the model is achieved with hierarchical priors and incrementally increasing 𝜷 from 0 to a threshold value of 0.25 over 75 epochs. The generative VAE model can be readily coupled with Quantitative Structure–Property Relationship (QSPR) analysis to develop an integrated end-to-end framework for fuel-property prediction and molecular design of novel promising fuels.

fuel design↗

Serial Pixel Analog-to-Digital Converter

This method reduces the data path from the counter to the pixel register of the analog-to-digital converter (ADC) from as many as 10 bits to a single bit. The reduction in data path width is accomplished by using a coded serial data stream similar to a pseudo random number (PRN) generator. The resulting encoded pixel data is then decoded into a standard hexadecimal format before storage. The high-speed serial pixel ADC concept is based on the single-slope integrating pixel ADC architecture. Previous work has described a massively parallel pixel readout of a similar architecture. The serial ADC connection is similar to the state-of-the art method with the exception that the pixel ADC register is a shift register and the data path is a single bit. A state-of-the-art individual-pixel ADC uses a single-slope charge integration converter architecture with integral registers and “one-hot” counters. This implies that parallel data bits are routed among the counter and the individual on-chip pixel ADC registers. The data path bit-width to the pixel is therefore equivalent to the pixel ADC bit resolution.

42 ENGINEERING↗

SU-E-T-144: Effective Analysis of VMAT QA Generated Trajectory Log Files for Medical Accelerator Predictive Maintenance

Purpose: To determine the effectiveness of SPC analysis for a model predictive maintenance process that uses accelerator generated parameter and performance data contained in trajectory log files. Methods: Each trajectory file is decoded and a total of 131 axes positions are recorded (collimator jaw position, gantry angle, each MLC, etc.). This raw data is processed and either axis positions are extracted at critical points during the delivery or positional change over time is used to determine axis velocity. The focus of our analysis is the accuracy, reproducibility and fidelity of each axis. A reference positional trace of the gantry and each MLC is used as a motion baseline for cross correlation (CC) analysis. A total of 494 parameters (482 MLC related) were analyzed using Individual and Moving Range (I/MR) charts. The chart limits were calculated using a hybrid technique that included the use of the standard 3σ limits and parameter/system specifications. Synthetic errors/changes were introduced to determine the initial effectiveness of I/MR charts in detecting relevant changes in operating parameters. The magnitude of the synthetic errors/changes was based on: TG-142 and published analysis of VMAT delivery accuracy. Results: All errors introduced were detected. Synthetic positional errors of 2mm for collimator jaw and MLC carriage exceeded the chart limits. Gantry speed and each MLC speed are analyzed at two different points in the delivery. Simulated Gantry speed error (0.2 deg/sec) and MLC speed error (0.1 cm/sec) exceeded the speed chart limits. Gantry position error of 0.2 deg was detected by the CC maximum value charts. The MLC position error of 0.1 cm was detected by the CC maximum value location charts for every MLC. Conclusion: SPC I/MR evaluation of trajectory log file parameters may be effective in providing an early warning of performance degradation or component failure for medical accelerator systems.

61 RADIATION PROTECTION AND DOSIMETRY↗

SU-C-BRD-03: Analysis of Accelerator Generated Text Logs for Preemptive Maintenance

Purpose: To develop a model to analyze medical accelerator generated parameter and performance data that will provide an early warning of performance degradation and impending component failure. Methods: A robust 6 MV VMAT quality assurance treatment delivery was used to test the constancy of accelerator performance. The generated text log files were decoded and analyzed using statistical process control (SPC) methodology. The text file data is a single snapshot of energy specific and overall systems parameters. A total of 36 system parameters were monitored which include RF generation, electron gun control, energy control, beam uniformity control, DC voltage generation, and cooling systems. The parameters were analyzed using Individual and Moving Range (I/MR) charts. The chart limits were calculated using a hybrid technique that included the use of the standard 3σ limits and the parameter/system specification. Synthetic errors/changes were introduced to determine the initial effectiveness of I/MR charts in detecting relevant changes in operating parameters. The magnitude of the synthetic errors/changes was based on: the value of 1 standard deviation from the mean operating parameter of 483 TB systems, a small fraction (≤ 5%) of the operating range, or a fraction of the minor fault deviation. Results: There were 34 parameters in which synthetic errors were introduced. There were 2 parameters (radial position steering coil, and positive 24V DC) in which the errors did not exceed the limit of the I/MR chart. The I chart limit was exceeded for all of the remaining parameters (94.2%). The MR chart limit was exceeded in 29 of the 32 parameters (85.3%) in which the I chart limit was exceeded. Conclusion: Statistical process control I/MR evaluation of text log file parameters may be effective in providing an early warning of performance degradation or component failure for digital medical accelerator systems. Research is Supported by Varian Medical Systems, Inc.

07 ISOTOPE AND RADIATION SOURCES↗

SU-E-I-90: Characterizing Small Animal Lung Properties Using Speckle Observed with An In-Line X-Ray Phase Contrast Benchtop System

Purpose: We demonstrate a novel X-ray phase-contrast (XPC) method for lung imaging representing a paradigm shift in the way small animal functional imaging is performed. In our method, information regarding airway microstructure that is encoded within speckle texture of a single XPC radiograph is decoded to produce 2D parametric images that will spatially resolve changes in lung properties such as microstructure sizes and air volumes. Such information cannot be derived from conventional lung radiography or any other 2D imaging modality. By computing these images at different points within a breathing cycle, dynamic functional imaging will be readily achieved without the need for tomography. Methods: XPC mouse lung radiographs acquired in situ with an in-line X-ray phase contrast benchtop system. The lung air volume is varied and controlled with a small animal ventilator. XPC radiographs will be acquired for various lung air volume levels representing different phases of the respiratory cycle. Similar data will be acquired of microsphere-based lung phantoms containing hollow glass spheres with known distributions of diameters. Image texture analysis is applied to the data to investigate relationships between texture characteristics and airspace/microsphere physical properties. Results: Correlations between Fourier-based texture descriptors (FBTDs) and regional lung air volume indicate that the texture features in 2D radiographs reveal information on 3D properties of the lungs. For example, we find for a 350 × 350 πm2 lung ROI a linear relationship between injected air volume and FBTD value with slope and intercept of 8.9×10{sup 5} and 7.5, respectively. Conclusion: We demonstrate specific image texture measures related to lung speckle features are correlated with physical characteristics of refracting elements (i.e. lung air spaces). Furthermore, we present results indicating the feasibility of implementing the technique with a simple imaging system design, short exposures, and low dose which provides potential for widespread use in laboratory settings for in vivo studies. This research was supported in part by NSF Award CBET1263988.

60 APPLIED LIFE SCIENCES↗

MO-F-CAMPUS-J-03: Development of a Human Brain PET for On-Line Proton Beam-Range Verification

Purpose: To develop a prototype PET for verifying proton beam-range before each fractionated therapy that will enable on-line re-planning proton therapy. Methods: Latest “edge-less” silicon photomultiplier arrays and customized ASIC readout electronics were used to develop PET detectors with depth-of-interaction (DOI) measurement capability. Each detector consists of one LYSO array with each end coupled to a SiPM array. Multiple detectors can be seamlessly tiled together to form a large detector panel. Detectors with 1.5×1.5 and 2.0×2.0 mm crystals at 20 or 30 mm lengths were studied. Readout of individual SiPM or signal multiplexing was used to transfer 3D interaction position-coded analog signals through flexible-print-circuit cables or PCB board to dedicated ASIC front-end electronics to output digital timing pulses that encode interaction information. These digital pulses can be transferred to, through standard LVDS cables, and decoded by a FPGA-based data acquisition of coincidence events and data transfer. The modular detector and scalable electronics/data acquisition will enable flexible PET system configuration for different imaging geometry. Results: Initial detector performance measurement shows excellent crystal identification even with 30 mm long crystals, ∼18% and 2.8 ns energy and timing resolutions, and around 2–3 mm DOI resolution. A small prototype PET scanner with one detector ring has been built and evaluated, validating the technology and design. A large size detector panel has been fabricated by scaling up from modular detectors. Different designs of resistor and capacitor based signal multiplexing boards were tested and selected based on optimal crystal identification and timing performance. Stackable readout electronics boards and FPGA-based data acquisition boards were developed and tested. A brain PET is under construction. Conclusion: Technology of large-size DOI detector based on SiPM array and advanced readout has been developed. PET imaging performance and initial phantom studies of on-line proton beam-range measurement will be conducted and reported. NIH grant R21CA187717; Cancer Prevention and Research Institute of Texas grant RP120326.

60 APPLIED LIFE SCIENCES↗

Lesion insertion in the projection domain: Methods and initial results

Purpose: To perform task-based image quality assessment in CT, it is desirable to have a large number of realistic patient images with known diagnostic truth. One effective way of achieving this objective is to create hybrid images that combine patient images with inserted lesions. Because conventional hybrid images generated in the image domain fails to reflect the impact of scan and reconstruction parameters on lesion appearance, this study explored a projection-domain approach. Methods: Lesions were segmented from patient images and forward projected to acquire lesion projections. The forward-projection geometry was designed according to a commercial CT scanner and accommodated both axial and helical modes with various focal spot movement patterns. The energy employed by the commercial CT scanner for beam hardening correction was measured and used for the forward projection. The lesion projections were inserted into patient projections decoded from commercial CT projection data. The combined projections were formatted to match those of commercial CT raw data, loaded onto a commercial CT scanner, and reconstructed to create the hybrid images. Two validations were performed. First, to validate the accuracy of the forward-projection geometry, images were reconstructed from the forward projections of a virtual ACR phantom and compared to physically acquired ACR phantom images in terms of CT number accuracy and high-contrast resolution. Second, to validate the realism of the lesion in hybrid images, liver lesions were segmented from patient images and inserted back into the same patients, each at a new location specified by a radiologist. The inserted lesions were compared to the original lesions and visually assessed for realism by two experienced radiologists in a blinded fashion. Results: For the validation of the forward-projection geometry, the images reconstructed from the forward projections of the virtual ACR phantom were consistent with the images physically acquired for the ACR phantom in terms of Hounsfield unit and high-contrast resolution. For the validation of the lesion realism, lesions of various types were successfully inserted, including well circumscribed and invasive lesions, homogeneous and heterogeneous lesions, high-contrast and low-contrast lesions, isolated and vessel-attached lesions, and small and large lesions. The two experienced radiologists who reviewed the original and inserted lesions could not identify the lesions that were inserted. The same lesion, when inserted into the projection domain and reconstructed with different parameters, demonstrated a parameter-dependent appearance. Conclusions: A framework has been developed for projection-domain insertion of lesions into commercial CT images, which can be potentially expanded to all geometries of CT scanners. Compared to conventional image-domain methods, the authors’ method reflected the impact of scan and reconstruction parameters on lesion appearance. Compared to prior projection-domain methods, the authors’ method has the potential to achieve higher anatomical complexity by employing clinical patient projections and real patient lesions.

60 APPLIED LIFE SCIENCES↗

TU-FG-201-09: Predicting Accelerator Dysfunction

Purpose: To develop an integrated statistical process control (SPC) framework using digital performance and component data accumulated within the accelerator system that can detect dysfunction prior to unscheduled downtime. Methods: Seven digital accelerators were monitored for twelve to 18 months. The accelerators were operated in a ‘run to failure mode’ with the individual institutions determining when service would be initiated. Institutions were required to submit detailed service reports. Trajectory and text log files resulting from a robust daily VMAT QA delivery were decoded and evaluated using Individual and Moving Range (I/MR) control charts. The SPC evaluation was presented in a customized dashboard interface that allows the user to review 525 monitored parameters (480 MLC parameters). Chart limits were calculated using a hybrid technique that includes the standard SPC 3σ limits and an empirical factor based on the parameter/system specification. The individual (I) grand mean values and control limit ranges of the I/MR charts of all accelerators were compared using statistical (ranked analysis of variance (ANOVA)) and graphical analyses to determine consistency of operating parameters. Results: When an alarm or warning was directly connected to field service, process control charts predicted dysfunction consistently on beam generation related parameters (BGP)– RF Driver Voltage, Gun Grid Voltage, and Forward Power (W); beam uniformity parameters – angle and position steering coil currents; and Gantry position accuracy parameter: cross correlation max-value. Control charts for individual MLC – cross correlation max-value/position detected 50% to 60% of MLCs serviced prior to dysfunction or failure. In general, non-random changes were detected 5 to 80 days prior to a service intervention. The ANOVA comparison of BGP determined that each accelerator parameter operated at a distinct value. Conclusion: The SPC framework shows promise. Long term monitoring coordinated with service will be required to definitively determine the effectiveness of the model. Varian Medical System, Inc. provided funding in support of the research presented.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Regulation of translation by ribosomal RNA pseudouridylation

Pseudouridine is enriched in ribosomal, spliceosomal, transfer, and messenger RNA and thus integral to the central dogma. The chemical basis for how pseudouridine affects the molecular apparatus such as ribosome, however, remains elusive owing to the lack of structures without this natural modification. Here, we studied the translation of a hypopseudouridylated ribosome initiated by the internal ribosome entry site (IRES) elements. We analyzed eight cryo–electron microscopy structures of the ribosome bound with the Taura syndrome virus IRES in multiple functional states. We found widespread loss of pseudouridine-mediated interactions through water and long-range base pairings. In the presence of the translocase, eukaryotic elongation factor 2, and guanosine 5'-triphosphate hydrolysis, the hypopseudouridylated ribosome favors a rare unconducive conformation for decoding that is partially recouped in the ribosome population that remains modified at the P-site uridine. The structural principles learned establish the link between functional defects and modification loss and are likely applicable to other pseudouridine-associated processes.

59 BASIC BIOLOGICAL SCIENCES↗

Demonstration of Communication using Neutrinos

Beams of neutrinos have been proposed as a vehicle for communications under unusual circumstances, such as direct point-to-point global communication, communication with submarines, secure communications and interstellar communication. We report on the performance of a low-rate communications link established using the NuMI beam line and the MINERvA detector at Fermilab. The link achieved a decoded data rate of 0.1 bits/sec with a bit error rate of 1% over a distance of 1.035 km, including 240 m of earth.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Analysis of a Runtime Data Sharing Architecture over LTE for a Heterogeneous CAV Fleet

This paper describes a lightweight runtime architecture for telemetry, communication, and control of cars deployed with advanced driver assistance systems where a human is in the loop with the car, via an LTE connection. The system architecture supports both local control decisions based on car sensors and safety algorithms as well as high-level input from external systems that may provide insight into traffic state ahead of sensor data. Implementation of the architecture is done in ROS and depends on open-source software packages for runtime decoding of information from the vehicle’s controller area network (CAN) and integration of GPS data from accompanying sensors. The contribution of the paper is to describe the overall architecture, the data it can communicate to other systems, performance of the system at runtime, and challenges faced when deploying the architecture across a heterogeneous fleet. Preliminary results from analysis of test data will provide insights into whether the use of high-latency communication can be effective for societal-scale intelligent transportation systems when applied in future scenarios

Richardson, Alex↗

Demonstrating Cross-Facility Data Processing at Scale with Laue Microdiffraction

In February and April 2023 live, at-scale data processing demonstrations were conducted between the Advanced Photon Source (APS), a synchrotron light source, and the Argonne Leadership Computing Facility (ALCF). These tests were run as part of a novel beamline technique: coded aperture laue micro-diffraction. This technique requires a significant amount of compute to decode appeture patterns embedded in the detector stream. An autonomous system was able to send data to ALCF during an experiment, utilize 50 nodes of the Polaris supercomputer to process 6-12 hour scans, and return the data back to the APS within 12-15 minutes behind the detector. With scan points arriving every 72 seconds, the system kept up with the beamline, potentially enabling in-experiment analysis. The data processing system utilizes Globus infrastructure and an on-demand queue to dynamically acquire nodes on Polaris. The underlying reconstruction algorithms were parallelized via MPI and accelerated with custom CUDA kernels.

Prince, Michael↗

Fast 2D Bicephalous Convolutional Autoencoder for Compressing 3D Time Projection Chamber Data

High-energy large-scale particle colliders produce data at high speed in the order of 1 terabytes per second in nuclear physics and petabytes per second in high energy physics. Developing real-time data compression algorithms to reduce such data at high throughput to fit permanent storage has drawn increasing attention. Specifically, at the newly constructed sPHENIX experiment at the Relativistic Heavy Ion Collider (RHIC), a time projection chamber is used as the main tracking detector, which records particle trajectories in a volume of three-dimensional (3D) cylinder. The resulting data are usually very sparse with occupancy around 10.8%. Such sparsity presents a challenge to conventional learning-free lossy compression algorithms, such as SZ, ZFP, and MGARD. The 3D convolutional neural network (CNN)-based approach, Bicephalous Convolutional Autoencoder (BCAE), outperforms traditional methods both in compression rate and reconstruction accuracy. BCAE can also utilize the computation power of graphical processing units suitable for deployment in a modern heterogeneous highperformance computing environment. This work introduces two BCAE variants: BCAE++ and BCAE-2D. BCAE++ achieves a 15% better compression ratio and a 77% better reconstruction accuracy measured in mean absolute error compared with BCAE. BCAE-2D treats the radial direction as the channel dimension of an image, resulting in a 3× speedup in compression throughput. In addition, we demonstrate an unbalanced autoencoder with a larger decoder can improve reconstruction accuracy without significantly sacrificing throughput. Lastly, we observe both the BCAE++ and BCAE-2D can benefit more from using half-precision mode in throughput (76 - 79% increase) without loss in reconstruction accuracy. The source code and links to data and pretrained models can be found at https://github.com/BNL-DAQ-LDRD/NeuralCompression_v2

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗