Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “DESIGN”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,153 records · Page 64

Design and reactivity of pentapyridyl metal complexes for ammonia oxidation

Oxidation of NH3 to N2 by pentapyridyl metal complexes via hydrogen atom abstraction was investigated computationally. Quantum chemical analysis reveals insights on orbital symmetry requirements for efficient NH3 oxidation. The most promising complex, [(PY5)Mo(NH3)]2+, was studied experimentally. It shows conversion of NH3 to N2 upon treatment with 2,4,6-tri-tertbutylphenoxyl radical.

Johnson, Samantha JI↗

A new non-diffusional gas bubble production route in used nuclear fuel: Implications for fission gas release, cladding corrosion, and next generation fuel design

The relationship between noble metal phase particles and fission gas bubble production in used nuclear fuel is described. The majority of Te atoms within noble metal phase undergo radioactive decay to form stable Xe within a few hours after particle formation. This results in the production of clusters of Xe atoms contained within the solid metal matrix exhibiting an equivalent gas bubble pressure approaching 1 GPa. These high pressure bubbles are stabilized by the UO2 within the bulk of the fuel. However, when these bubbles form near the fuel / cladding interface, in combination with local and temporal damage caused by fission recoil, they are capable of overcoming the fracture strength of the UO2 and rupturing catastrophically. The force of the resulting bubble rupture is sufficient to eject noble metal phase particles several microns into the cladding. This proposed mechanism explains the observance of noble metal phase in cladding and is consistent with a host of morphological features found near the fuel / cladding interface.

Schwantes, Jon M.↗

New molecular design for blue BODIPYs

Dihydro analogues of BODIPYs exhibit spectral features ( Φ f ∼ 0.4–0.9) resembling aminocoumarins and suggest applications for broad-band photosensitization or where large Stokes shifts are desired.

Wu, Zhiyuan↗

Design of functional composite and all-inorganic nanostructured materials via infiltration of polymer templates with inorganic precursors

Robust and efficient approaches for the synthesis of materials with structure, porosity, and composition controlled at the nanoscale are highly important for a wide range of applications. Polymer templates are promising platforms to achieve such control. The self-assembly process of polymers provides access to diverse structures that can serve as templates for the deposition of inorganic materials. By infiltrating metal precursors from gas or liquid phases, using sequential infiltration synthesis (SIS) or swelling-based infiltration (SBI), respectively, into the polymer templates, one can create finely-tuned texturing of the surface films and bulk materials. In this review, we outline the specifics and dynamics of the polymer infiltration process and characterize the structure and properties of the synthesized materials. Finally, we highlight recent progress in implementing polymer infiltration-based nanoporous ceramics for many applications, including sensors, antireflective coatings, oil-absorbing foams, nanolithographic patterns, and catalytic materials.

Berman, Diana↗

Standard design for National Ignition Facility x-ray streak and framing cameras

The x-ray streak camera and x-ray framing camera for the National Ignition Facility were redesigned to improve electromagnetic pulse hardening, protect high voltage circuits from pressure transients, and maximize the use of common parts and operational software. Both instruments use the same PC104 based controller, interface, power supply, charge coupled device camera, protective hermetically sealed housing, and mechanical interfaces. Communication is over fiber optics with identical facility hardware for both instruments. Each has three triggers that can be either fiber optic or coax. High voltage protection consists of a vacuum sensor to enable the high voltage and pulsed microchannel plate phosphor voltage. In the streak camera, the high voltage is removed after the sweep. Both rely on the hardened aluminum box and a custom power supply to reduce electromagnetic pulse/electromagnetic interference (EMP/EMI) getting into the electronics. In addition, the streak camera has an EMP/EMI shield enclosing the front of the streak tube.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Fusion-neutron-yield, activation measurements at the Z accelerator: Design, analysis, and sensitivity

We present a general methodology to determine the diagnostic sensitivity that is directly applicable to neutron-activation diagnostics fielded on a wide variety of neutron-producing experiments, which include inertial-confinement fusion (ICF), dense plasma focus, and ion beam-driven concepts. This approach includes a combination of several effects: (1) non-isotropic neutron emission; (2) the 1/r{sup 2} decrease in neutron fluence in the activation material; (3) the spatially distributed neutron scattering, attenuation, and energy losses due to the fielding environment and activation material itself; and (4) temporally varying neutron emission. As an example, we describe the copper-activation diagnostic used to measure secondary deuterium-tritium fusion-neutron yields on ICF experiments conducted on the pulsed-power Z Accelerator at Sandia National Laboratories. Using this methodology along with results from absolute calibrations and Monte Carlo simulations, we find that for the diagnostic configuration on Z, the diagnostic sensitivity is 0.037% ± 17% counts/neutron per cm{sup 2} and is ∼ 40% less sensitive than it would be in an ideal geometry due to neutron attenuation, scattering, and energy-loss effects.

43 PARTICLE ACCELERATORS↗

A new spectrometer design for the x-ray spectroscopy of laser-produced plasmas with high (sub-ns) time resolution

This paper describes a new type of x-ray crystal spectrometer, which can be used in combination with gated x-ray detectors to obtain spectra from laser-produced plasmas with a high (sub-ns) time resolution. The spectrometer consists of a convex, spherically bent crystal, which images individual spectral lines as perfectly straight lines across multiple, sequentially gated, strip detectors. Since the Bragg-reflected rays are divergent, the distance between detector and crystal is arbitrary, so that this distance can be appropriately chosen to optimize the experimental arrangement with respect to the detector parameters. The spectrometer concept was verified in proof-of-principle experiments by imaging the Lβ{sub 1}- and Lβ{sub 2}-lines of tungsten, at 9.6735 and 9.96150 keV, from a micro-focus x-ray tube with a tungsten target onto a two-dimensional pixilated Pilatus detector, using a convex, spherically bent Si-422 crystal with a radius of curvature of 500 mm.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Device characterization for design optimization of 4 junction inverted metamorphic concentrator solar cells

Quantitative electroluminescence (EL) and luminescent coupling (LC) analysis, along with more conventional characterization techniques, are combined to completely characterize the subcell JV curves within a fourjunction (4J) inverted metamorphic solar cell (IMM). The 4J performance under arbitrary spectral conditions can be predicted from these subcell JV curves. The internal radiative efficiency (IRE) of each junction has been determined as a function of current density from the external radiative efficiency using optical modeling, but this required the accurate determination of the individual junction current densities during the EL measurement as affected by LC. These measurement and analysis techniques can be applied to any multijunction solar cell. The 4J IMM solar cell used to illustrate these techniques showed excellent junction quality as exhibited by high IRE and a one-sun AM1.5D efficiency of 36.3%. This device operates up to 1000 suns without limitations due to any of the three tunnel junctions.

14 SOLAR ENERGY↗