Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “CHART”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,153 records · Page 64

Nuclear Integrated Hydrogen Production Analysis Tool

This is an Excel-based time-independent discount cash flow calculator for LWR-HTSE systems. The tool incorporates (1) discounted cash flow and levelized cost of hydrogen (LCOH) analysis, (2) sensitivity analysis with respect to select financial performance metrics with output ‘tornado’ charts, (3) profitability analysis represented by heat maps using the two most sensitive parameters, (4) electricity versus hydrogen production preference analysis by comparing change in net present value (?NPV) between NPP-HTSE and business-as-usual electricity production for the grid, and (5) competitiveness analysis by comparing the calculated LCOH for NPP-HTSE with that of steam methane reforming, which is the conventional process to produce hydrogen.

Cheng, WenChi [Idaho National Laboratory (INL), Id↗

MCP-eGridGPT (MCP-Enabled Chatbot with Electrical Power System Analysis and Interactive Visualization Tool) [SWR-25-126]

This software is an advanced chatbot system that integrates the Model Context Protocol (MCP) to provide intelligent electrical power system analysis and automated visualization generation. The system enables users to interact with complex electrical engineering tools through natural language, automatically analyzes power system data for voltage violations and grid health assessment, and generates professional interactive HTML dashboards and reports. Key features include dynamic tool discovery from MCP servers, multi-LLM provider support, intelligent data interpretation using large language models, automated chart generation, and a web-based interface for real-time analysis. The software bridges sophisticated electrical engineering analysis with user-friendly interfaces, making power system diagnostics accessible through conversational AI.

Choi, Seong [National Laboratory of the Rockies (N↗

AIF for Vis (Active Inference for simulating human interpretation of data visualization) [SWR-26-084]

AIF for Vis contains the Active Inference models and analysis scripts used to study a simple visualization-interpretation task: estimating the average value of two bars in a bar chart. The work is a proof of concept for translating hypothesized cognitive strategies into executable, inspectable process models. We implement two idealized strategies inspired by dual-process accounts of visualization-aided decision making: *Fast model: a compressed, heuristic strategy that estimates the visual midpoint of the two bars and maintains a single belief over their average. *Slow model: a sequential, analytic strategy that estimates the two bar heights separately and maintains them in working memory before computing an average. Both models use a common Active-Inference-inspired framework for sequential perception, belief updating, action selection, and reporting. Their different internal representations produce distinct predicted vulnerabilities: *the Fast model is more susceptible to tick-salience bias; *the Slow model is more susceptible to working-memory decay. The repository includes the model implementations, scripts used for the experiments reported in the paper, precomputed trial-level results, and plotting scripts.

Goldwyn, Harrison [National Laboratory of the Rock↗

CO2 Handling & Electrolyzer Efficiency Scaling Evaluator

CHEESE is an interactive dashboard tool for estimating the performance and material requirements of carbon dioxide electrolysis systems. It helps users evaluate how electrode area, current density, product selectivity, gas flow, cell voltage, and the number of cells in a stack affect system operation. The dashboard provides simple and advanced modes so it can be used for both quick estimates and more detailed engineering analysis. Users can estimate product output, carbon dioxide use, electrical power, electrode area, gas and liquid flow rates, energy efficiency, material cost per test, and the effect of scaling from a single cell to a multi cell stack. It also includes tools for examining carbon balance, equipment durability, component replacement, and changes in performance over time. This is intended to help both academia and industry researchers who are either getting into CO2 electrolysis on lab-scale or are trying to establish a larger footprint. CHEESE presents results through tables, charts, and simplified cell and stack diagrams. It is intended to support research planning, experimental design, comparison of operating conditions, and early stage scale up studies.

Prajapati, Aditya [Lawrence Livermore National Lab↗

ENDF/B-VIII.1: Decay Reaction Sublibrary

The decay sublibrary aims to describe all known spontaneous decays and branching ratios for all nuclei across the nuclide chart. ENDF/B-VIII.1 remains unchanged from ENDF/B-VIII.0 for the decay sublibrary.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Predictors and Cumulative Frequency of Hepatocellular Carcinoma in High and Intermediate LI-RADS Lesions: A Cohort Study from a Canadian Academic Institution

Background: The frequency and predictors of hepatocellular carcinoma (HCC) within each liver imaging reporting and data system (LI-RADS) category remains unclear. We sought to estimate the cumulative frequency of HCC in LI-RADS observations of high/intermediate category and identify clinical/radiographic features associated with HCC. Methods: Our diagnostic imaging database was searched for computed tomography/magnetic resonance imaging reports of patients with evidence of cirrhosis and liver observations. LI-RADS categories were determined by imaging review, while demographic and clinical outcomes were assigned by chart review. A composite outcome of clinical/radiographic confirmation of HCC was used. We used multivariable analysis to identify features associated with HCC, and competing risks regression to estimate the cumulative frequency of HCC in each category. Results: Our search returned 95 patients with 137 observations (LR2 = 4, LR3 = 53, LR4 = 37, and LR5 = 43). On multivariable analysis, increasing age (hazard ratio [HR] 1.76 per 10 years, p = 0.049), washout (HR 5.34, p < 0.002), and increasing size (size < 10 mm reference, 10–20 mm, HR 3.93, p = 0.014; size > 20 mm, HR 21.69, p < 0.001) were associated with HCC. Median time to diagnosis was 6.13 months (interquartile range [IQR] 4.6–13.1), 4.7 months (IQR 2.5–14.5), and 3.6 months (IQR 1.9–6.6) for LR3, 4, and 5 category observations, respectively. The cumulative frequency of HCC was 59.8% in LR3, 84.62% in LR4, and 99.84% in LR5, at last follow-up. Conclusion: The frequency of HCC within each LI-RADS category reflects the intended purpose, intermediate probability for LR3, probable HCC for LR4, and definite HCC for LR5.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Neoadjuvant Chemotherapy does not Increase Complications in Oncoplastic Breast-Conserving Surgery

Background: Oncoplastic breast-conserving surgery (OBCS) broadens the indications for breast conservation. Neoadjuvant systemic chemotherapy (NAC) is used increasingly in the treatment of patients with early-stage and locally advanced breast cancer. This study aimed to evaluate the outcomes for patients who received NAC followed by OBCS. Methods: A retrospective chart review was performed for all patients who underwent OBCS involving the mastopexy/breast-reduction technique, including synchronous mastopexy/breast reduction for symmetry, at the University of Texas MD Anderson Cancer Center between January 2010 and January 2016. Patients who had received NAC were compared with those who had undergone surgery first. Demographic, treatment, and outcomes data were collected. Results: The study included 429 patients, corresponding to 713 breasts. Of these patients, 122, corresponding to 199 breasts, received NAC. The patients who received NAC were younger (p < 0.001) and had a more advanced cancer stage (p < 0.001). The overall complication rate per patient was 25.9%, with major complications occurring in 9.1% of the patients. After adjustment for risk factors, NAC was not shown to be associated with an increased risk of complications or delayed adjuvant radiation therapy (p = 0.37), irrespective of the chemotherapy regimen used or whether the interval between NAC and surgery was 4 weeks or longer. Conclusions: In a high-volume center, OBCS can be performed safely for carefully selected patients after NAC without an increased risk of complications or delayed adjuvant radiation therapy. An interval of at least 4 weeks between completion of NAC and surgery can be regarded as safe irrespective of the chemotherapy regimen used.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Neoadjuvant Chemotherapy and Nipple-Sparing Mastectomy: Timing and Postoperative Complications

Background: As the demand for nipple-sparing mastectomy (NSM) increases and surgeons expand the eligibility criteria, a subset of patients may become candidates following neoadjuvant chemotherapy (NACT). However, the impact of NACT on postoperative complications remains unclear as the current literature is discordant. Methods: A single-institution, retrospective chart review was performed on patients undergoing NSM from 1989 to 2017. Patient demographics, surgical intervention, systemic treatment, and complication rates were collected. Primary outcomes were 30-day postoperative complications, including nipple-areolar necrosis, skin flap necrosis, infection, wound dehiscence, hematoma, and seroma. Secondary outcomes included characterization of the timing between chemotherapy and surgical intervention, and the impact on complication rates. Each breast was considered independently for analysis, and breasts undergoing either NACT or primary surgery (PS) were compared. Results: Of the 832 breasts included, 88 (10.6%) received NACT and 744 (89.4%) underwent PS. Baseline complication rates were not significantly different between the NACT group and the PS group (5.7% vs. 10.6%; p = 0.119). When controlling for age, body mass index (BMI), smoking, and prior radiation, NACT was not a predictor of complications. Time from completion of NACT to PS occurred at a median of 40.5 days (interquartile range 31.3–55.3), and decreased intervals were not associated with increased complication rates. Conclusions: Postoperative complications following NSM in patients completing NACT are comparable with those receiving PS. Patients undergoing NACT do not have a significantly increased risk of necrosis, unintended reoperations, or nipple loss. NACT should not be considered a contraindication for NSM.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Physician Perspectives on Fertility Preservation Discussions with Premenopausal Breast Cancer Patients: Results from a Multihospital Health Care System

Background: Ten percent of new breast cancer diagnoses occur in premenopausal women, and oncologic therapies may compromise fertility. Thus, fertility preservation discussions (FPDs) and referral to fertility specialists are imperative prior to initiation of therapy. A previous retrospective chart review showed 45% FPD rates at our institution. The aim of this study is to investigate physician perspectives and limitations regarding FPD. Methods: An electronic survey was distributed to 30 surgical, medical, and radiation oncologists across ten regional hospitals. Questions addressed provider demographics, and barriers to and facilitators of FPD. Results: The survey response rate was 63.3%. Only 31.6% of physicians reported “always” documenting FPD. Respondents opined that the physician prescribing systemic therapy was the most appropriate person to provide FPD. Patient age, treatment with chemotherapy, and patient desire for FPD were more likely to increase FPD (p < 0.0001, p < 0.05, and p < 0.0001, respectively). The majority of physicians (84.2%) expressed intent to increase FPD rates. Conclusions: Fertility preservation is an integral aspect of breast cancer care, requiring thorough discussion and clear documentation. This study identified that physicians believe the medical oncologist is the most appropriate person to have FPDs with patients and that empowering patients to bring up fertility concerns may improve rates of FPDs. Education of physicians and patients about fertility preservation techniques is likely to improve FPDs.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Strain-concentration for fast, compact photonic modulation and non-volatile memory

A critical figure of merit (FoM) for electro-optic (EO) modulators is the transmission change per voltage, d T / d V . Conventional approaches in wave-guided modulators maximize d T / d V via a high EO coefficient or longer light-material interaction lengths but are ultimately limited by material losses and nonlinearities. Optical and RF resonances improve d T / d V at the cost of spectral non-uniformity, especially for high- Q optical cavity resonances. Here, we introduce an EO modulator based on piezo-strain-concentration of a photonic crystal cavity to address both trade-offs: (i) it eliminates the trade-off between d T / d V and waveguide loss—i.e., enhancement of the resonance tuning efficiency d v c / d V for the fixed EO coefficient, waveguide length, and cavity Q —and (ii) at high DC strains it exhibits a non-volatile (NV) cavity tuning Δ v c ,NV for passive memory and programming of multiple devices into resonance despite fabrication variations. The device is fabricated on a scalable silicon nitride-on-aluminum nitride platform. We measure d v c / d V =177±1MHz/V, corresponding to Δ v c =40±0.32GHz for a voltage spanning ±120V with an energy consumption of δ U /Δ v c =0.17nW/GHz. The modulation bandwidth is flat up to ω BW,3dB /2 π =3.2±0.07MHz for broadband DC-AC and 142±17MHz for resonant operation near a 2.8 GHz mechanical resonance. Optical extinction up to 25 dB is obtained via Fano-type interference. Strain-induced beam-buckling modes are programmable under a “read-write” protocol with a continuous, repeatable tuning range of 5±0.25GHz, allowing for storage and retrieval, which we quantify with mutual information of 2.4 bits and a maximum non-volatile excursion of 8 GHz. Using a full piezo-optical finite-element-model (FEM) we identify key design principles for optimizing strain-based modulators and chart a path towards achieving performance comparable to lithium niobate-based modulators and the study of high strain physics on-chip.

Wen, Y. Henry (ORCID:0009000685423628)↗

Enabling AI in synthetic biology through Construction File specification

The Construction File (CF) specification establishes a standardized interface for molecular biology operations, laying a foundation for automation and enhanced efficiency in experiment design. It is implemented across three distinct software projects: PyDNA_CF_Simulator, a Python project featuring a ChatGPT plugin for interactive parsing and simulating experiments; ConstructionFileSimulator, a field-tested Java project that showcases 'Experiment' objects expressed as flat files; and C6-Tools, a JavaScript project integrated with Google Sheets via Apps Script, providing a user-friendly interface for authoring and simulation of CF. The CF specification not only standardizes and modularizes molecular biology operations but also promotes collaboration, automation, and reuse, significantly reducing potential errors. The potential integration of CF with artificial intelligence, particularly GPT-4, suggests innovative automation strategies for synthetic biology. While challenges such as token limits, data storage, and biosecurity remain, proposed solutions promise a way forward in harnessing AI for experiment design. This shift from human-driven design to AI-assisted workflows, steered by high-level objectives, charts a potential future path in synthetic biology, envisioning an environment where complexities are managed more effectively.

59 BASIC BIOLOGICAL SCIENCES↗

Brine stability study

This is a study of the brine formulations that we were using in our testing were stable over time. The data includes charts, as well as, all of the original data from the ICP-MS runs to complete this study.

15 GEOTHERMAL ENERGY↗

Utah FORGE: Deep Wells Temperature Surveys as of September 2022

This Excel spreadsheet contains temperature survey results for Utah FORGE wells 58-32, 78-32, 56-32, 16A(78)-32 and 78B-32. It also contains charts and comparisons, along with a "Data Summary" which provides links to previous GDR submissions with temperature data for each well.

15 GEOTHERMAL ENERGY↗

Baseline vs. DER Scenario

Projections and associated uncertainty estimates are generated for a variety of user-selectable EV charging sessions, electricity tariffs, subsidy levels, revenue schemes, charging station configurations, and on-site solar and/or storage options. The outputs are presented in CHIP's web portal browser in the form of easily interpretable graphics (interactive graphs and bar charts) that facilitate convenient comparison among different scenarios to aid decision-making. The user should bring assumptions for modeling on simulation planning horizon, number of EV charging sessions per year, electricity costs (energy and demand charge rates; flat versus time-of-use rate), site capital costs (equipment for EV chargers and transformer), solar PV, and battery energy storage (kW).

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Baseline vs. DER Scenario

Projections and associated uncertainty estimates are generated for a variety of user-selectable EV charging sessions, electricity tariffs, subsidy levels, revenue schemes, charging station configurations, and on-site solar and/or storage options. The outputs are presented in CHIP's web portal browser in the form of easily interpretable graphics (interactive graphs and bar charts) that facilitate convenient comparison among different scenarios to aid decision-making. The user should bring assumptions for modeling on simulation planning horizon, number of EV charging sessions per year, electricity costs (energy and demand charge rates; flat versus time-of-use rate), site capital costs (equipment for EV chargers and transformer), solar PV, and battery energy storage (kW).

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Baseline vs. DER Scenario

Projections and associated uncertainty estimates are generated for a variety of user-selectable EV charging sessions, electricity tariffs, subsidy levels, revenue schemes, charging station configurations, and on-site solar and/or storage options. The outputs are presented in CHIP's web portal browser in the form of easily interpretable graphics (interactive graphs and bar charts) that facilitate convenient comparison among different scenarios to aid decision-making. The user should bring assumptions for modeling on simulation planning horizon, number of EV charging sessions per year, electricity costs (energy and demand charge rates; flat versus time-of-use rate), site capital costs (equipment for EV chargers and transformer), solar PV, and battery energy storage (kW).

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Baseline vs. DER Scenario

Projections and associated uncertainty estimates are generated for a variety of user-selectable EV charging sessions, electricity tariffs, subsidy levels, revenue schemes, charging station configurations, and on-site solar and/or storage options. The outputs are presented in CHIP's web portal browser in the form of easily interpretable graphics (interactive graphs and bar charts) that facilitate convenient comparison among different scenarios to aid decision-making. The user should bring assumptions for modeling on simulation planning horizon, number of EV charging sessions per year, electricity costs (energy and demand charge rates; flat versus time-of-use rate), site capital costs (equipment for EV chargers and transformer), solar PV, and battery energy storage (kW).

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗