Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “CASE METHOD”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,153 records · Page 64

Quantifying Interobserver Variation in Target Definition in Palliative Radiotherapy

Purpose: To describe the degree of interobserver and intraobserver variability in target and field definition when using three-dimensional (3D) volume- vs. two-dimensional (2D) field-based planning. Methods and Materials: Standardized case scenario and diagnostic imaging for 9 palliative cases (3 bone metastases, 3 palliative lung cancer, and 3 abdominal pelvis soft-tissue disease) were presented to 5 study radiation oncologists. After a decision on what the intended anatomic target should be, observers created two sets of treatment fields, first using a 2D field-based and then a 3D volume-based planning approach. Percent overlap, under-coverage, and over-coverage were used to describe interobserver and intraobserver variations in target definition. Results: The degree of interobserver variation for 2D and 3D planning was similar with a degree of overlap of 76% (range, 56%-85%) and 74% (range, 55%-88%), respectively. When comparing the treatment fields defined by the same observer using the two different planning methods, the mean degree of overlap was 78%; over-coverage, 22%; and under-coverage, 41%. There was statistically significantly more under-coverage when field-based planning was used for bone metastases (33%) vs. other anatomic sites (16%) (p = 0.02). In other words, 2D planning is more likely to result in geographic misses in bone metastases compared with other areas. Conclusions: In palliative radiotherapy clinically significant interobserver and intraobserver variation existed when using both field- and volume-based planning approaches. Strategies that would reduce this variability deserve further investigation.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

A TRACER METHOD FOR COMPUTING TYPE IA SUPERNOVA YIELDS: BURNING MODEL CALIBRATION, RECONSTRUCTION OF THICKENED FLAMES, AND VERIFICATION FOR PLANAR DETONATIONS

We refine our previously introduced parameterized model for explosive carbon–oxygen fusion during thermonuclear Type Ia supernovae (SNe Ia) by adding corrections to post-processing of recorded Lagrangian fluid-element histories to obtain more accurate isotopic yields. Deflagration and detonation products are verified for propagation in a medium of uniform density. A new method is introduced for reconstructing the temperature–density history within the artificially thick model deflagration front. We obtain better than 5% consistency between the electron capture computed by the burning model and yields from post-processing. For detonations, we compare to a benchmark calculation of the structure of driven steady-state planar detonations performed with a large nuclear reaction network and error-controlled integration. We verify that, for steady-state planar detonations down to a density of 5 × 10{sup 6} g cm{sup −3}, our post-processing matches the major abundances in the benchmark solution typically to better than 10% for times greater than 0.01 s after the passage of the shock front. As a test case to demonstrate the method, presented here with post-processing for the first time, we perform a two-dimensional simulation of a SN Ia in the scenario of a Chandrasekhar-mass deflagration–detonation transition (DDT). We find that reconstruction of deflagration tracks leads to slightly more complete silicon burning than without reconstruction. The resulting abundance structure of the ejecta is consistent with inferences from spectroscopic studies of observed SNe Ia. We confirm the absence of a central region of stable Fe-group material for the multi-dimensional DDT scenario. Detailed isotopic yields are tabulated and change only modestly when using deflagration reconstruction.

79 ASTRONOMY AND ASTROPHYSICS↗

Determination of the asymptotic normalization coefficients for 14 C + n <--> 15 C, the 14 C(n, gamma) 15 C reaction rate, and evaluation of a new method to determine spectroscopic factors

The 14 C + n <--> 15 C system has been used as a test case in the evaluation of a new method to determine spectroscopic factors that uses the asymptotic normalization coefficient (ANC). The method proved to be unsuccessful for this case. As part of this experimental program, the ANCs for the 15 C ground state and first excited state were determined using a heavy-ion neutron transfer reaction as well as the inverse kinematics (d,p) reaction, measured at the Texas A&M Cyclotron Institute. The ANCs were used to evaluate the astrophysical direct neutron capture rate on 14 C, which was then compared with the most recent direct measurement and found to be in good agreement. A study of the 15 C SF via its mirror nucleus 15 F and a new insight into deuteron stripping theory are also presented.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Toward Prostate Cancer Contouring Guidelines on Magnetic Resonance Imaging: Dominant Lesion Gross and Clinical Target Volume Coverage Via Accurate Histology Fusion

Purpose: Defining prostate cancer (PCa) lesion clinical target volumes (CTVs) for multiparametric magnetic resonance imaging (mpMRI) could support focal boosting or treatment to improve outcomes or lower morbidity, necessitating appropriate CTV margins for mpMRI-defined gross tumor volumes (GTVs). This study aimed to identify CTV margins yielding 95% coverage of PCa tumors for prospective cases with high likelihood. Methods and Materials: Twenty-five men with biopsy-confirmed clinical stage T1 or T2 PCa underwent pre-prostatectomy mpMRI, yielding T2-weighted, dynamic contrast-enhanced, and apparent diffusion coefficient images. Digitized whole-mount histology was contoured and registered to mpMRI scans (error ≤2 mm). Four observers contoured lesion GTVs on each mpMRI scan. CTVs were defined by isotropic and anisotropic expansion from these GTVs and from multiparametric (unioned) GTVs from 2 to 3 scans. Histologic coverage (proportions of tumor area on co-registered histology inside the CTV, measured for Gleason scores [GSs] ≥6 and ≥7) and prostate sparing (proportions of prostate volume outside the CTV) were measured. Nonparametric histologic-coverage prediction intervals defined minimal margins yielding 95% coverage for prospective cases with 78% to 92% likelihood. Results: On analysis of 72 true-positive tumor detections, 95% coverage margins were 9 to 11 mm (GS ≥ 6) and 8 to 10 mm (GS ≥ 7) for single-sequence GTVs and were 8 mm (GS ≥ 6) and 6 mm (GS ≥ 7) for 3-sequence GTVs, yielding CTVs that spared 47% to 81% of prostate tissue for the majority of tumors. Inclusion of T2-weighted contours increased sparing for multiparametric CTVs with 95% coverage margins for GS ≥6, and inclusion of dynamic contrast-enhanced contours increased sparing for GS ≥7. Anisotropic 95% coverage margins increased the sparing proportions to 71% to 86%. Conclusions: Multiparametric magnetic resonance imaging–defined GTVs expanded by appropriate margins may support focal boosting or treatment of PCa; however, these margins, accounting for interobserver and intertumoral variability, may preclude highly conformal CTVs. Multiparametric GTVs and anisotropic margins may reduce the required margins and improve prostate sparing.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

A BLIND METHOD TO DETREND INSTRUMENTAL SYSTEMATICS IN EXOPLANETARY LIGHT CURVES

The study of the atmospheres of transiting exoplanets requires a photometric precision, and repeatability, of one part in ∼10{sup 4}. This is beyond the original calibration plans of current observatories, hence the necessity to disentangle the instrumental systematics from the astrophysical signals in raw data sets. Most methods used in the literature are based on an approximate instrument model. The choice of parameters of the model and their functional forms can sometimes be subjective, causing controversies in the literature. Recently, Morello et al. (2014, 2015) have developed a non-parametric detrending method that gave coherent and repeatable results when applied to Spitzer/IRAC data sets that were debated in the literature. Said method is based on independent component analysis (ICA) of individual pixel time-series, hereafter “pixel-ICA”. The main purpose of this paper is to investigate the limits and advantages of pixel-ICA on a series of simulated data sets with different instrument properties, and a range of jitter timescales and shapes, non-stationarity, sudden change points, etc. The performances of pixel-ICA are compared against the ones of other methods, in particular polynomial centroid division, and pixel-level decorrelation method. We find that in simulated cases pixel-ICA performs as well or better than other methods, and it also guarantees a higher degree of objectivity, because of its purely statistical foundation with no prior information on the instrument systematics. The results of this paper, together with previous analyses of Spitzer/IRAC data sets, suggest that photometric precision and repeatability of one part in 10{sup 4} can be achieved with current infrared space instruments.

79 ASTRONOMY AND ASTROPHYSICS↗

Validating and Comparing Energy Estimation Methods at Water Resource Recovery Facilities

Water resource recovery facilities play a crucial role in the water-energy nexus, consuming a substantial amount of energy in the United States. Growing treatment volumes and more stringent water quality standards are expected to increase the amount of energy needed to treat wastewater, but accurately estimating energy consumption and potential remains challenging due to variability in scale, treatment methods, and effluent treatment standards. In this study, we used publicly available data to evaluate the accuracy of methods for estimating energy consumption and generation, then quantified uncertainty based on key factors like flow rate, treatment level, and geographic location. To validate methods, we estimated energy consumption and generation at the facility-level, then compared estimates to self-reported data from utilities in major U.S. cities. We found that process models of treatment trains under best practice configurations were accurate relative to other methods for estimating electricity use, total energy use, and electricity generation from biogas utilization, and less complex methods based on effluent treatment level and prime movers also performed well for estimating electricity consumption and generation, respectively. Applying the evaluated methods to a national inventory of treatment facilities, we estimate that annual energy consumption ranged from 56.3 x 10^3 to 82.5 x 10^3 TJ in 2012 and 83.6 x 10^3 to 127 x 10^3 TJ in 2042. Our results indicate that not all estimation methods are suited for every use case, so we recommend that researchers and practitioners select an estimation method based on data availability and desired computational intensity.

Hodson, Abigayle↗

Linear entropy in quantum phase space

We calculate the quantum Renyi entropy in a phase-space representation for either fermions or bosons. This can also be used to calculate purity and fidelity, or the entanglement between two systems. We show that it is possible to calculate the entropy from sampled phase-space distributions in normally ordered representations, although this is not possible for all quantum states. We give an example of the use of this method in an exactly soluble thermal case. The quantum entropy cannot be calculated at all using sampling methods in classical symmetric (Wigner) or antinormally ordered (Husimi) phase spaces, due to inner-product divergences. The preferred method is to use generalized Gaussian phase-space methods, which utilize a distribution over stochastic Green's functions. We illustrate this approach by calculating the reduced entropy and entanglement of bosonic or fermionic modes coupled to a time-evolving, non-Markovian reservoir.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Validation of an in-vivo proton beam range check method in an anthropomorphic pelvic phantom using dose measurements

Purpose: In-vivo dosimetry and beam range verification in proton therapy could play significant role in proton treatment validation and improvements. In-vivo beam range verification, in particular, could enable new treatment techniques one of which could be the use of anterior fields for prostate treatment instead of opposed lateral fields as in current practice. This paper reports validation study of an in-vivo range verification method which can reduce the range uncertainty to submillimeter levels and potentially allow for in-vivo dosimetry. Methods: An anthropomorphic pelvic phantom is used to validate the clinical potential of the time-resolved dose method for range verification in the case of prostrate treatment using range modulated anterior proton beams. The method uses a 3 × 4 matrix of 1 mm diodes mounted in water balloon which are read by an ADC system at 100 kHz. The method is first validated against beam range measurements by dose extinction measurements. The validation is first completed in water phantom and then in pelvic phantom for both open field and treatment field configurations. Later, the beam range results are compared with the water equivalent path length (WEPL) values computed from the treatment planning system XIO. Results: Beam range measurements from both time-resolved dose method and the dose extinction method agree with submillimeter precision in water phantom. For the pelvic phantom, when discarding two of the diodes that show sign of significant range mixing, the two methods agree with ±1 mm. Only a dose of 7 mGy is sufficient to achieve this result. The comparison to the computed WEPL by the treatment planning system (XIO) shows that XIO underestimates the protons beam range. Quantifying the exact XIO range underestimation depends on the strategy used to evaluate the WEPL results. To our best evaluation, XIO underestimates the treatment beam range between a minimum of 1.7% and maximum of 4.1%. Conclusions: Time-resolved dose measurement method satisfies the two basic requirements, WEPL accuracy and minimum dose, necessary for clinical use, thus, its potential for in-vivo protons range verification. Further development is needed, namely, devising a workflow that takes into account the limits imposed by proton range mixing and the susceptibility of the comparison of measured and expected WEPLs to errors on the detector positions. The methods may also be used for in-vivo dosimetry and could benefit various proton therapy treatments.

60 APPLIED LIFE SCIENCES↗

Application of radial-equilibrium condition to axial-flow compressor and turbine design

Basic general equations governing the three-dimensional compressible flow of gas through a compressor or turbine are given in terms of total enthalpy, entropy, and velocity components of the gas. Two methods of solution are obtained for the simplified, steady axially symmetric flow; one involves the use of a number of successive planes normal to the axis of the machine and short distances apart, and the other involves only three stations for a stage in which an appropriate radial-flow path is used. Methods of calculation for the limiting cases of zero and infinite blade aspect ratios and an approximate method of calculation for finite blade aspect ratio are also given. In these methods, the blade loading and the shape of the annular passage wall may be arbitrarily specified.

Wu, Chung-Hua↗

Launch Vehicle Design and Optimization Methods and Priority for the Advanced Engineering Environment

NASA's Advanced Engineering Environment (AEE) is a research and development program that will improve collaboration among design engineers for launch vehicle conceptual design and provide the infrastructure (methods and framework) necessary to enable that environment. In this paper, three major technical challenges facing the AEE program are identified, and three specific design problems are selected to demonstrate how advanced methods can improve current design activities. References are made to studies that demonstrate these design problems and methods, and these studies will provide the detailed information and check cases to support incorporation of these methods into the AEE. This paper provides background and terminology for discussing the launch vehicle conceptual design problem so that the diverse AEE user community can participate in prioritizing the AEE development effort.

Rowell, Lawrence F.↗

General image method in a plane-layered elastostatic medium

The general-image method presently used to obtain the elastostatic fields in plane-layered media relies on the use of potentials in order to represent elastic fields. For the case of a single interface, this method yields the displacement field in closed form, and is applicable to antiplane, plane, and three-dimensional problems. In the case of multiplane interfaces, the image method generates the displacement fields in terms of infinite series whose convergences can be accelerated to improve method efficiency.

Fares, N.↗

One-parameter families of supersymmetric isospectral potentials from Riccati solutions in function composition form

In the context of supersymmetric quantum mechanics, we define a potential through a particular Riccati solution of the composition form (F∘f)(x)=F(f(x)) and obtain a generalized Mielnik construction of one-parameter isospectral potentials when we use the general Riccati solution. Some examples for special cases of F and f are given to illustrate the method. An interesting result is obtained in the case of a parametric double well potential generated by this method, for which it is shown that the parameter of the potential controls the heights of the localization probability in the two wells, and for certain values of the parameter the height of the localization probability can be higher in the smaller well. -- Highlights: •Function-composition generalization of parametric isospectral potentials is presented. •Mielnik one-parameter family of harmonic potentials is obtained as a particular case. •Graphical discussion of regular and singular regions in the parameter space is given.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Uncluttered single-image visualization of the abdominal aortic vessel tree: Method and evaluation

Purpose: The authors develop a method to visualize the abdominal aorta and its branches, obtained by CT or MR angiography, in a single 2D stylistic image without overlap among branches. Methods: The abdominal aortic vasculature is modeled as an articulated object whose underlying topology is a rooted tree. The inputs to the algorithm are the 3D centerlines of the abdominal aorta, its branches, and their associated diameter information. The visualization problem is formulated as an optimization problem that finds a spatial configuration of the bounding boxes of the centerlines most similar to the projection of the input into a given viewing direction (e.g., anteroposterior), while not introducing intersections among the boxes. The optimization algorithm minimizes a score function regarding the overlap of the bounding boxes and the deviation from the input. The output of the algorithm is used to produce a stylistic visualization, made of the 2D centerlines modulated by the associated diameter information, on a plane. The authors performed a preliminary evaluation by asking three radiologists to label 366 arterial branches from the 30 visualizations of five cases produced by the method. Each of the five patients was presented in six different variant images, selected from ten variants with the three lowest and three highest scores. For each label, they assigned confidence and distortion ratings (low/medium/high). They studied the association between the quantitative metrics measured from the visualization and the subjective ratings by the radiologists. Results: All resulting visualizations were free from branch overlaps. Labeling accuracies of the three readers were 93.4%, 94.5%, and 95.4%, respectively. For the total of 1098 samples, the distortion ratings were low: 77.39%, medium: 10.48%, and high: 12.12%. The confidence ratings were low: 5.56%, medium: 16.50%, and high: 77.94%. The association study shows that the proposed quantitative metrics can predict a reader's subjective ratings and suggests that the visualization with the lowest score should be selected for readers. Conclusions: The method for eliminating misleading false intersections in 2D projections of the abdominal aortic tree conserves the overall shape and does not diminish accurate identifiability of the branches.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

The Stabilizing Effectiveness of Conical Flares on Bodies with Conical Noses

An analysis is presented of published results of force tests on 80 cone-cylinder-flare configurations at Mach numbers of 2.18, 2.81, and 4.04. The contributions, excluding interference effects, of the cone-cylinder bodies to the over-all normal force derivatives have been removed by means of the second-order shock-expansion method, and the normal force derivatives at zero angle of attack due to the flares alone are shown. The results from a wide variety of configurations are correlated by plotting ratios of the normal force derivatives of the flares to the normal force derivatives of cones having the same included angle. Comparisons are made of the experimental normal force results with the normal force derivatives obtained by assuming conical flow over the flares and with those obtained by use of the second-order shock-expansion method. The comparisons show that use of the second-order shock-expansion method is generally the superior of the two, and in most cases gives values of the normal force derivatives of the flares which agree very well with the experimental results. Centers of pressure of the flares are presented and comparisons are made with results obtained from the theories mentioned. In general, the comparisons show that the assumption of conical flow over the flares is comparable to use of the second-order shock-expansion method in determining the centers of pressure, and in many cases both methods give values which agree closely with the experimental results.

Kirk, Donn B.↗

A BAYESIAN METHOD FOR THE ANALYSIS OF THE DUST EMISSION IN THE FAR-INFRARED AND SUBMILLIMETER

We present a method, based on Bayesian statistics, to fit the dust emission parameters in the far-infrared and submillimeter wavelengths. The method estimates the dust temperature and spectral emissivity index, plus their relationship, properly taking into account the statistical and systematic uncertainties. We test it on three sets of simulated sources detectable by the Herschel Space Observatory in the PACS and SPIRE spectral bands (70-500 {mu}m), spanning over a wide range of dust temperatures. The simulated observations are a one-component interstellar medium and two two-component sources, both warm (H II regions) and cold (cold clumps (CCs)). We first define a procedure to identify the better model, then we recover the parameters of the model and measure their physical correlations by means of a Markov Chain Monte Carlo algorithm adopting multi-variate Gaussian priors. In this process, we assess the reliability of the model recovery and of parameter estimation. We conclude that the model and parameters are properly recovered only under certain circumstances and that false models may be derived in some cases. We applied the method to a set of 91 starless CCs in an interarm region of the Galactic plane with low star formation activity, observed by Herschel in the Hi-GAL survey. Our results are consistent with a temperature-independent spectral index.

79 ASTRONOMY AND ASTROPHYSICS↗

Application of Dorodnitsyn's Integral Method to Nonequilibrium Flows over Pointed Bodies

Dorodnitsyn's integral method is used to obtain an approximate solution to the supersonic nonequilibrium flow over pointed bodies with attached shock waves. The partial differential equations governing the flow are converted to an approximate set of ordinary equations, which are solved by numerical integration starting at the body tip. Detailed analytical and numerical results for the first approximation are presented, considering the vibrational relaxation of a diatomic gas over a wedge or cone. It is shown that the first approximation yields: (1) The exact flow-variable gradients at the wedge tip (2) Expressions for the flow-variable gradients at the cone tip which are in agreement with extrapolations of characteristics calculations (3) A good approximate algebraic solution for frozen or equilibrium conical flow (4) An approximate expression for the nonequilibrium-flow stream function which affords a means of obtaining variations across the shock layer of the temperature and vibrational energy. Numerical results for both the wedge and cone compare favorably with identical cases computed by the method of characteristics.

NONEQUILIBRIUM FLOW↗

Dynamic Mode Decomposition for Compressive System Identification

Dynamic mode decomposition has emerged as a leading technique to identify spatiotemporal coherent structures from high-dimensional data, benefiting from a strong connection to nonlinear dynamical systems via the Koopman operator. In this work, we integrate and unify two recent innovations that extend DMD to systems with actuation [Proctor et al., 2016] and systems with heavily subsampled measurements [Brunton et al., 2015]. When combined, these methods yield a novel framework for compressive system identification [code is publicly available at: https://github.com/zhbai/cDMDc]. It is possible to identify a low-order model from limited input-output data and reconstruct the associated full-state dynamic modes with compressed sensing, adding interpretability to the state of the reduced-order model. Moreover, when full-state data is available, it is possible to dramatically accelerate downstream computations by first compressing the data. We demonstrate this unified framework on two model systems, investigating the effects of sensor noise, different types of measurements (e.g., point sensors, Gaussian random projections, etc.), compression ratios, and different choices of actuation (e.g., localized, broadband, etc.). In the first example, we explore this architecture on a test system with known low-rank dynamics and an artificially inflated state dimension. The second example consists of a real-world engineering application given by the fluid flow past a pitching airfoil at low Reynolds number. This example provides a challenging and realistic test-case for the proposed method, and results demonstrate that the dominant coherent structures are well characterized despite actuation and heavily subsampled data.

97 MATHEMATICS AND COMPUTING↗