Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “CABLES”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,153 records · Page 64

ISS Fiber Optic Failure Investigation Root Cause Report

In August of 1999, Boeing Corporation (Boeing) engineers began investigating failures of optical fiber being used on International Space Station flight hardware. Catastrophic failures of the fiber were linked to a defect in the glass fiber. Following several meetings of Boeing and NASA engineers and managers, Boeing created and led an investigation team, which examined the reliability of the cable installed in the U.S. Lab. NASA Goddard Space Flight Center's Components Technologies and Radiation Effects Branch (GSFC) led a team investigating the root cause of the failures. Information was gathered from: regular telecons and other communications with the investigation team, investigative trips to the cable distributor's plant, the cable manufacturing plant and the fiber manufacturing plant (including a review of build records), destructive and non-destructive testing, and expertise supplied by scientists from Dupont, and Lucent-Bell Laboratories. Several theories were established early on which were not able to completely address the destructive physical analysis and experiential evidence. Lucent suggested hydrofluoric acid (HF) etching of the glass and successfully duplicated the "rocket engine" defect. Strength testing coupled with examination of the low strength break sites linked features in the polyimide coating with latent defect sites. The information provided below explains what was learned about the susceptibility of the pre-cabled fiber to failure when cabled as it was for Space Station and the nature of the latent defects.

Leidecker, Henning↗

Electrifying Development

With technical assistance from Marshall Space Flight Center and Kennedy Space Center, Protective Cable and Wire developed Lightning Retardant Cable (LRC). LRC improves lightning protection over standard coaxial cable by 100 percent. The LRC design keeps lightning from traveling through the cable, preventing damage to satellites, antennas, and cable systems. LRC is now being used in homes as well as airports.

Source record↗

Tangleproof Coupling

Along with Marshall Space Flight Center, Phase 2 Automation developed a unique rotary coupling capable of connecting a large number of electrical cables to a turntable without stressing the cables or tangling them. Device accommodates 246 cables and allows the turntable to rotate through an arc of 320 degrees. At extremes of rotation the cables remain loose enough so that they are not pulled taut and overstressed; a halfway rotation, the cables are not so loose that they tangle. The rotary connector was developed to carry electrical signals to and from a telescope platform on the satellite without employing a complex set of slip rings which are electrically noisy and could have caused signal interference.

Source record↗

Efficient and Robust Data Collection Using Compact Micro Hardware, Distributed Bus Architectures and Optimizing Software

Future In-Space propulsion systems for exploration programs will invariably require data collection from a large number of sensors. Consider the sensors needed for monitoring several vehicle systems states of health, including the collection of structural health data, over a large area. This would include the fuel tanks, habitat structure, and science containment of systems required for Lunar, Mars, or deep space exploration. Such a system would consist of several hundred or even thousands of sensors. Conventional avionics system design will require these sensors to be connected to a few Remote Health Units (RHU), which are connected to robust, micro flight computers through a serial bus. This results in a large mass of cabling and unacceptable weight. This paper first gives a survey of several techniques that may reduce the cabling mass for sensors. These techniques can be categorized into four classes: power line communication, serial sensor buses, compound serial buses, and wireless network. The power line communication approach uses the power line to carry both power and data, so that the conventional data lines can be eliminated. The serial sensor bus approach reduces most of the cabling by connecting all the sensors with a single (or redundant) serial bus. Many standard buses for industrial control and sensor buses can support several hundreds of nodes, however, have not been space qualified. Conventional avionics serial buses such as the Mil-Std-1553B bus and IEEE 1394a are space qualified but can support only a limited number of nodes. The third approach is to combine avionics buses to increase their addressability. The reliability, EMI/EMC, and flight qualification issues of wireless networks have to be addressed. Several wireless networks such as the IEEE 802.11 and Ultra Wide Band are surveyed in this paper. The placement of sensors can also affect cable mass. Excessive sensors increase the number of cables unnecessarily. Insufficient number of sensors may not provide adequate coverage of the system. This paper also discusses an optimal technique to place and validate sensors.

micro hardware↗

Multiaxis, Lightweight, Computer-Controlled Exercise System

The multipurpose, multiaxial, isokinetic dynamometer (MMID) is a computer-controlled system of exercise machinery that can serve as a means for quantitatively assessing a subject s muscle coordination, range of motion, strength, and overall physical condition with respect to a wide variety of forces, motions, and exercise regimens. The MMID is easily reconfigurable and compactly stowable and, in comparison with prior computer-controlled exercise systems, it weighs less, costs less, and offers more capabilities. Whereas a typical prior isokinetic exercise machine is limited to operation in only one plane, the MMID can operate along any path. In addition, the MMID is not limited to the isokinetic (constant-speed) mode of operation. The MMID provides for control and/or measurement of position, force, and/or speed of exertion in as many as six degrees of freedom simultaneously; hence, it can accommodate more complex, more nearly natural combinations of motions and, in so doing, offers greater capabilities for physical conditioning and evaluation. The MMID (see figure) includes as many as eight active modules, each of which can be anchored to a floor, wall, ceiling, or other fixed object. A cable is payed out from a reel in each module to a bar or other suitable object that is gripped and manipulated by the subject. The reel is driven by a DC brushless motor or other suitable electric motor via a gear reduction unit. The motor can be made to function as either a driver or an electromagnetic brake, depending on the required nature of the interaction with the subject. The module includes a force and a displacement sensor for real-time monitoring of the tension in and displacement of the cable, respectively. In response to commands from a control computer, the motor can be operated to generate a required tension in the cable, to displace the cable a required distance, or to reel the cable in or out at a required speed. The computer can be programmed, either locally or via a remote terminal, to support exercises in one or more of the usual exercise modes (isometric, isokinetic, or isotonic) along complex, multiaxis trajectories. The motions of, and forces applied by, the subject can be monitored in real time and recorded for subsequent evaluation. Through suitable programming, the exercise can be adjusted in real time according to the physical condition of the subject. The remote- programming capability makes it possible to connect multiple exercise machines into a network for supervised exercise by multiple subjects or even for competition by geographically dispersed subjects.

Haynes, Leonard↗

Magnetically Attached Multifunction Maintenance Rover

A versatile mobile telerobot, denoted the magnetically attached multifunction maintenance rover (MAGMER), has been proposed for use in the inspection and maintenance of the surfaces of ships, tanks containing petrochemicals, and other large ferromagnetic structures. As its name suggests, this robot would utilize magnetic attraction to adhere to a structure. As it moved along the surface of the structure, the MAGMER would perform tasks that could include close-up visual inspection by use of video cameras, various sensors, and/or removal of paint by water-jet blasting, laser heating, or induction heating. The water-jet nozzles would be mounted coaxially within compressed-air-powered venturi nozzles that would collect the paint debris dislodged by the jets. The MAGMER would be deployed, powered, and controlled from a truck, to which it would be connected by hoses for water, compressed air, and collection of debris and by cables for electric power and communication (see Figure 1). The operation of the MAGMER on a typical large structure would necessitate the use of long cables and hoses, which can be heavy. To reduce the load of the hoses and cables on the MAGMER and thereby ensure its ability to adhere to vertical and overhanging surfaces, the hoses and cables would be paid out through telescopic booms that would be parts of a MAGMER support system. The MAGMER would move by use of four motorized, steerable wheels, each of which would be mounted in an assembly that would include permanent magnets and four pole pieces (see Figure 2). The wheels would protrude from between the pole pieces by only about 3 mm, so that the gap between the pole pieces and the ferromagnetic surface would be just large enough to permit motion along the surface but not so large as to reduce the magnetic attraction excessively. In addition to the wheel assemblies, the MAGMER would include magnetic adherence enhancement fixtures, which would comprise arrays of permanent magnets and pole pieces that could be adjusted to maximize or minimize the overall attractive magnetic force. Even with a paint thickness of 2 mm, a preliminary design provides a safety factor of 5 in the magnetic force in the upside- down, water-jets-operating condition, in which the total load (including the weight of the MAGMER and cables and the water-jet force) would be about 260 lb (the weight of 118 kg). Optionally, the MAGMER could carry magnetic shielding and/or could be equipped with a demagnetizing module to remove residual magnetism from the structure. The MAGMER would carry four charge-coupled-device cameras for visual inspection, monitoring of operation, navigation, and avoidance of collisions with obstacles. The control system of the MAGMER would include navigation and collision-avoidance subsystems that would utilize surface features as landmarks, in addition to direct images of obstacles.

Bar-Cohen, Yoseph↗

Accuracy of Center of Pressure Determination via Motion Capture

BACKGROUND: This study was conducted to support the stability assessment for tasks in lunar gravity and exercises on a Vibration Isolation and Stabilization (VIS) system in microgravity based on the dynamic feasibility criterion of whether the calculated position of the center of pressure (COP) falls within the base of support (BOS) which outlines the subject’s feet. Motion capture data combined with biomechanical modeling and simulation allows the forces and moments between the human and the VIS platform to be computed and the position of the COP as well as the location and shape of the BOS to be determined. The goal of this study was to assess the accuracy of the COP trajectory calculated using motion capture-based data. METHODS AND RESULTS: To obtain the dynamic quantities from which COP is calculated, motion capture data is first collected in the 1g lab environment by recording the trajectories of passive retroreflective markers placed on a subject during exercise or performance of a given task. The OpenSim [1] inverse kinematics (IK) tool is used to fit a scaled subject model to recorded marker trajectories while minimizing marker error to obtain joint angles. Then, a custom OpenSim plugin [2] is used to determine the subject’s time-varying moment of inertia and its time derivative, center of mass (CM) position, velocity, and acceleration, as well as the angular momentum and its time derivative relative to the subject’s CM. Some of these quantities are not needed for modeling tasks performed on a stationary lunar surface but, due to the moving exercise platform, are needed to model VIS response to the subject’s motion. Hand positions, used in calculating a cable force if present, are recorded as well. These quantities are used to calculate the total force (F ⃗^((plate) )) and moment (M ⃗^((plate) )) exerted by the lunar surface or the VIS plate on the subject’s shoe soles. COP is then calculated from the following equations: r_x^((cop) )= M_z^((plate) )/F_y^((plate) ) and r_z^((cop) )= 〖-M〗_x^((plate) )/F_y^((plate) ), where the y axis is normal to the surface. COP accuracy for feasibility assessments is then determined by whether it falls within the BOS, which is also computed by the plugin. To study the accuracy of COP calculated from motion capture, we first investigated whether COP remained within the BOS, as it must, for exercises performed in the 1g lab environment. Standard exercises such as back squat and deadlift were analyzed, as well as more explosive exercises including hang clean and press. Cases in which the COP exited the BOS indicated that COP accuracy required further investigation. In this study, an exercise device with cables was used, so cable force modeling accuracy should also be considered. In a separate study, we collected motion capture and force plate data for twenty-seven motions not involving an exercise device. About a third were genuine countermeasures exercises (e.g., hang clean and press), some were relevant for lunar tasks (e.g., object pick up), and the rest were of a “unit test” nature (e.g., swaying back and forth or side to side). Motion capture-based COP positions were compared with force plate measured COP. We found that while force plate measured COP remained within the BOS, motion capture-based COP was observed to briefly exit the BOS on occasion. Techniques to mitigate IK artifacts and filtering of calculated data could be used to improve the agreement of calculated and measured results, resolving excursions from the BOS within this dataset. The mean error between calculated and measured COP was found to be less than 6 mm. Additionally, we derived and investigated equations for the COP in terms of the cable force, cable location, as well as the human CM position, acceleration, and angular momentum with respect to the CM, and analyzed them for sensitivity to errors in individual quantities. Several were found, but the most significant one was that when the vertical force on the feet approaches zero, indicating a near-detachment or ‘jump off’ condition, errors are amplified. This is consistent with the observation that in the absence of pressure, the concept of the center of pressure would become meaningless.

C A Bell↗

Termination unit

This invention relates to a termination unit comprising an end-section of a cable. The end section of the cable defines a central longitudinal axis and comprising end-parts of N electrical phases, an end-part of a neutral conductor and a surrounding thermally insulation envelope adapted to comprising a cooling fluid. The end-parts of the N electrical phases and the end-part of the neutral conductor each comprising at least one electrical conductor and being arranged in the cable concentrically around a core former with a phase 1 located relatively innermost, and phase N relatively outermost in the cable, phase N being surrounded by the neutral conductor, electrical insulation being arrange between neighboring electrical phases and between phase N and the neutral conductor, and wherein the end-parts of the neutral conductor and the electrical phases each comprise a contacting surface electrically connected to at least one branch current lead to provide an electrical connection: The contacting surfaces each having a longitudinal extension, and being located sequentially along the longitudinal extension of the end-section of the cable. The branch current leads being individually insulated from said thermally insulation envelope by individual electrical insulators.

42 ENGINEERING↗

Device for remote operation of electrical disconnect

Provided is a device for remote operation of an electrical disconnect. The device can include a handle clamp configured to be secured to an extending member of the electrical disconnect. The device can further include a case clamp configured to be secured to a rigid portion of the electrical disconnect. The device can further include a cable having an exterior sheath coaxially surrounding an inner cable. The inner cable can be coaxially slidable with respect to the exterior sheath. The inner cable can extend through an opening of the case clamp and be secured to the handle clamp. The device can further include an actuator configured to coaxially slide the inner cable such that the handle clamp is actuated towards the case clamp.

42 ENGINEERING↗

Secure passive RFID tag with seal

A secure passive RFID tag system comprises at least one base station and at least one passive RFID tag. The tag includes a fiber optic cable with the cable ends sealed within the tag and the middle portion forming an external loop. The loop may be secured to at least portions of an object. The tag transmits and receives an optical signal through the fiber optic cable, and the cable is configured to be damaged or broken in response to removal or tampering attempts, wherein the optical signal is significantly altered if the cable is damaged or broken. The tag transmits the optical signal in response to receiving a radio signal from the base station and compares the transmitted optical signal to the received optical signal. If the transmitted optical signal and the received optical signal are identical, the tag transmits an affirmative radio signal to the base station.

36 MATERIALS SCIENCE↗

Long-pulse-width variable-wavelength chirped pulse generator and method

A device for creating an optic pulse with different wavelengths separated by time. A pump laser is configured to output energy to a dye cell which, responsive to the energy, outputs an optic pulse. Mirrors direct the optic pulse away from the dye cell towards a spectrograph. The spectrograph has an input and two or more outputs. The spectrograph receives and converts the optic pulse to a wavelength separated optic signal presented on the two or more outputs. A first optic cable has an input end and an output end. The input end receives a first output from the spectrograph. A second optic cable has an input end and an output end. The input end receives a second output from the spectrograph. The second optic cable is a different length than the first optic cable to establish a time shift between the signals exiting the first and second cable.

42 ENGINEERING↗

Microstructure dependence of the c-axis critical current density in second generation YBCO tapes

C-axis current flow in high temperature superconductor (HTS) tape-shaped wires arises in configurations where the local wire axis is not perpendicular to the local magnetic field, such as in power cables with helically wound HTS tapes. The c-axis critical current density J{sub c}{sup c} has been recently found to be orders of magnitude lower than the ab-plane critical current density J{sub c}{sup ab}. Here we report on J{sub c}{sup c} (77 K, sf) values of various YBa{sub 2}Cu{sub 3}O{sub 7}-based (YBCO) tapes with different microstructures. Our results show that the value of J{sub c}{sup c} (77 K, sf) decreases significantly with increasing concentration of ab-plane stacking faults in YBCO thin films and that the critical current anisotropy {gamma} = J{sub c}{sup ab}/J{sub c}{sup c} can reach values as high as 2070, implying that in the highest-anisotropy tape, {approx}20% of the tape width carries c-axis current in a helically wound power cable.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Advanced Diagnosis and Accelerated Testing of Balance of System Components for Utility Scale PV Installations: October 1, 2022-September 30, 2024

A study of the durability of PV Balance of System components was performed. Specifically, wire cable jackets and cable connectors were examined within the direct current (DC) PV Power Transmission Chain (PTC). Degraded and failed samples have been obtained from utility PV installations to provide feedback on the degradation modes and the related damage-enabling considerations in today's PV systems. An industry interface group (including system owners, system inspectors, component manufacturers, and test labs) was used to help identify and obtain field-failed samples, for feedback (including samples and experimental design), and to facilitate the subsequent dissemination of the results of this study. Samples were empirically studied using accelerated stress testing with steady-state conditions (cable jackets) in addition to combined-accelerated stress testing (cable jackets, connectors and uncapped connectors). Steady-state accelerated testing has been performed using at least one applied stressor (e.g. UV light) to aid understanding of jacket durability relative to its application. Component- and material-focused failure analysis was conducted to develop an understanding and advise the PV industry. In-depth characterization will be applied selectively to field- and artificially aged-samples, to gain scientific understanding of the structural, chemical, electrical, mechanical, and thermal properties enabling degradation.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Calculating the Starting Currents of Electric Motors in 0.4 kV Auxiliary Networks of Nuclear Power Plants

Consideration is given to the effect of the resistance of the cable supplying power to the electric motor in the 0.4 kV auxiliary network of a nuclear (thermal) power plant on the starting current and, hence, on the current setpoint for the circuit breaker, on its sensitivity to short-circuit current, and on the cable size. It is shown that accounting for the resistance of the power cable of the motor that is commensurable with the starting resistance of the latter allows using a cable of smaller size compared with that determined regardless of its resistance.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Solution and sensitivity analysis of nonlinear equations using a hypercomplex-variable Newton-Raphson method

Here, the classical Newton-Raphson (NR) method for solving nonlinear equations is enhanced in two ways through the use of hypercomplex variables and algebra. In particular, i) the Jacobian is computed in a highly accurate and automated way, and ii) the derivative of the solution to the nonlinear equations is computed with respect to any parameter contained within the system of equations. These advances provide two significant enhancements in that it is straightforward to provide an accurate Jacobian and to construct a reduced order model (ROM) of arbitrary order with respect to any parameter of the system. The ROM can then be used to approximate the solution for other parameter values without requiring additional solutions of the nonlinear equations. Several case studies are presented including 1D and 2D academic examples with fully functioning Python code provided. Additionally, a case of study of the catenary of an elastic cable subject to its own weight and a vertical point load. Derivatives up to 10th order were computed with respect to material, loading, and geometrical parameters. The derivatives were used to generate reduced order models of the cable deformation and reaction forces at its ends with respect to multiple input parameters. Results show that from a single hypercomplex evaluation of the cable under a single vertical point load, it is possible to generate an accurate reduced order model capable of predicting the cable deformation with 1.5 times the load in the opposite direction and with 3.5 times the load in the same direction without resolving the system of equations.

97 MATHEMATICS AND COMPUTING↗

Quench Tests of $Nb_3A1$ Small Racetrack Magnets

Two Cu stabilized Nb_3Al strands, Fl (Nb matrix) and F3 (Ta matrix), fabricated at NIMS were wound into Rutherford cables at Fermilab in collaboration with NIMS. A small race-track magnet using Fl Rutherford cable, the first Nb_3Al dipole magnet in the world, was constructed and tested to full current at Fermilab. This magnet was tested extensively to full short sample data and its quench characteristics were studied and reported. The 3-D magnetic field calculation was done with ANSYS to find the peak field. The quench characteristics of the magnet are explained with the characteristics of the Nb_3Al strand and Rutherford cable. The small racetrack magnet built using Ta matrix F3 strand was constructed and will be tested in the near future. The advantages and disadvantages of these Nb_3Al cables are briefly discussed.

43 PARTICLE ACCELERATORS↗

Test Results of the First US ITER TF Conductor in SULTAN

The US Domestic Agency is one of six parties supplying TF cable-in-conduit conductors (CICCs) for ITER. Previous tests have shown that measured performance of the TF CICCs can be much lower than expected from the strand properties at the projected uniaxial strain and that the cabling pattern may also be an important factor. Worst of all, voltage signals well below the expected critical surface could not be reliably interpreted or canceled, making test results very suspect. The TFUS1 sample was prepared to achieve multiple goals: (1) to ensure uniform current distribution and to eliminate parasitic voltage signals by improving joints, (2) to explore the potential benefits of a different cabling pattern for better support of strain-sensitive strands, and (3) to explore the source of voltage development in the cable through the use of innovative penetrating diagnostics. Test results of the first US-made samples are presented and discussed.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Minimum Quench Energy of Nb 3 Sn Wires With High Specific Heat Tape

A major problem of state-of-the-art Nb3Snaccelerator magnets is their long training due to thermo-mechanical perturbations. Increasing the specific heat, Cp, of the Rutherford cable would reduce and/or eliminate training by limiting the coils temperature rise. This paper studies feasibility of increasing the Cp of Rutherford-type cables by using thin composite Cu/Gd 2 O 3 and Cu/Gd 2 O 2 S tapes produced by HyperTech Research, Inc. The tape can be either wrapped around the cable, placed on the cable wide faces under the insulation, and/or inserted as a core. Wire samples outfitted with these high-Cp ribbons, or tapes, were prepared and tested at FNAL for their Minimum Quench Energy (MQE). At 90%Ic and 15 T, the average gain of MQE of the Nb 3 Sn wire soldered to the Cu/Gd 2 O 2 S 55 μm thick ribbon was 2.5, and further increased at larger transport currents.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗