Integration of High Dose Boron Implants--Modification of Device Parametrics through Implant Temperature Control
In the present study, we have extended a previously reported 250 nm logic p-S/D implant (7 keV B 4.5x10{sup 15} cm{sup -2}) process matching exercise [5] to include wafer temperature, and demonstrate that matching can be obtained by increasing the temperature of the wafer during implant. We found that the high dose rate delivered by the single wafer implanter caused the formation of a clear amorphous layer, which upon subsequent annealing altered the diffusion, activation, and clustering properties of the boron. Furthermore, increasing the temperature of the wafer during the implant was sufficient to suppress amorphization, allowing profiles and device parameters to become matched. Figure 5 shows a representative set of curves indicating the cluster phenomena observed for the lower temperature, high flux single wafer implanter, and the influence of wafer temperature on the profiles. The results indicate the strong primary effect of dose rate in determining final electrical properties of devices, and successful implementation of damage engineering using wafer temperature control.