Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “BLOOD VESSELS”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,153 records · Page 64

SU-F-I-80: Correction for Bias in a Channelized Hotelling Model Observer Caused by Temporally Variable Non-Stationary Noise

Purpose: Application of a channelized Hotelling model observer (CHO) over a wide range of x-ray angiography detector target dose (DTD) levels demonstrated substantial bias for conditions yielding low detectability indices (d’), including low DTD and small test objects. The purpose of this work was to develop theory and methods to correct this bias. Methods: A hypothesis was developed wherein the measured detectability index (d’b) for a known test object is positively biased by temporally variable non-stationary noise in the images. Hotelling’s T2 test statistic provided the foundation for a mathematical theory which accounts for independent contributions to the measured d’b value from both the test object (d’o) and non-stationary noise (d’ns). Experimental methods were developed to directly estimate d’o by determining d’ns and subtracting it from d’b, in accordance with the theory. Specifically, d’ns was determined from two sets of images from which the traditional test object was withheld. This method was applied to angiography images with DTD levels in the range 0 to 240 nGy and for disk-shaped iodine-based contrast targets with diameters 0.5 to 4.0 mm. Results: Bias in d’ was evidenced by d’b values which exceeded values expected from a quantum limited imaging system and decreasing object size and DTD. d’ns increased with decreasing DTD, reaching a maximum of 2.6 for DTD = 0. Bias-corrected d’o estimates demonstrated sub-quantum limited performance of the x-ray angiography for low DTD. Findings demonstrated that the source of non-stationary noise was detector electronic readout noise. Conclusion: Theory and methods to estimate and correct bias in CHO measurements from temporally variable non-stationary noise were presented. The temporal non-stationary noise was shown to be due to electronic readout noise. This method facilitates accurate estimates of d’ values over a large range of object size and detector target dose.

60 APPLIED LIFE SCIENCES↗

SU-F-T-630: Energy Spectral Study On Lipiodol After Trans-Arterial Chemoembolization Using the Flattened and Unflattened Photon Beams

Purpose: SBRT combining transarterial chemoembolization with Lipiodol is expected to improve local control. Our showed that the dose enhancement effect in the Lipiodol with 10X flattening filter free (FFF) was inserted. This study was to investigate the energy fluence variations of electron in the Lipiodol using flattened (FF) and FFF beams. Methods: FF and FFF for 6X and 10X beams by TrueBeam were used in this study. The Lipiodol (3 X 3 X 3 cm{sup 3}) was located at the depth of 5 cm in water, the dose enhancement factor (DEF) and energy fluence were calculated by Monte Carlo (MC) calculations (PHITS). Results: DEFs with FF and FFF of 6X were 17.1% and 24.3% at rebuild-up region in the Lipiodol (5.3cm depth), 7.0% and 17.0% at the center of Lipiodol (6.5cm depth), and −13.2% and −8.2% at behind Lipiodol (8.3cm depth). DEFs with FF and FFF of 10X were 21.7% and 15.3% at rebuild-up region, 8.2% and 10.5% at the center of Lipiodol, and −14.0% and −8.6% at behind Lipiodol. Spectral results showed that the FFF beam contained more low-energy (0–0.3MeV) component of electrons than FF beam, and FF beam contained more high-energy (over 0.3MeV) electrons than FFF beam in Lipiodol. Behind the Lipiodol, build-down effect with FF beam was larger than FFF beam because FF beam contained more high energy electrons. The difference of DEFs between FFF and FF beams for 6X were larger than for 10X. This is because 10X beam contained more high-energy electrons. Conclusion: It was found that the 6XFFF beam gives the largest change of energy fluence and the largest DEF in this study. These phenomena are mainly caused by component of low-energy electrons, and this energy is almost correspond to the boundary of photo electronic dominant and Compton scattering dominant region for photon beams.

60 APPLIED LIFE SCIENCES↗

TU-H-CAMPUS-IeP1-04: Combined Organ Dose for Digital Subtraction Angiography and Computed Tomography Using Monte Carlo Simulation

Purpose: The purpose of this study was to evaluate the combined organ dose of digital subtraction angiography (DSA) and computed tomography (CT) using a Monte Carlo (MC) simulation on the abdominal intervention. Methods: The organ doses for DSA and CT were obtained with MC simulation and actual measurements using fluorescent-glass dosimeters at 7 abdominal portions in an Alderson-Rando phantom. DSA was performed from three directions: posterior anterior (PA), right anterior oblique (RAO), and left anterior oblique (LAO). The organ dose with MC simulation was compared with actual radiation dose measurements. Calculations for the MC simulation were carried out with the GMctdospp (IMPS, Germany) software based on the EGSnrc MC code. Finally, the combined organ dose for DSA and CT was calculated from the MC simulation using the X-ray conditions of a patient with a diagnosis of hepatocellular carcinoma. Results: For DSA from the PA direction, the organ doses for the actual measurements and MC simulation were 2.2 and 2.4 mGy/100 mAs at the liver, respectively, and 3.0 and 3.1 mGy/100 mAs at the spinal cord, while for CT, the organ doses were 15.2 and 15.1 mGy/100 mAs at the liver, and 14.6 and 13.5 mGy/100 mAs at the spinal cord. The maximum difference in organ dose between the actual measurements and the MC simulation was 11.0% of the spleen at PA, 8.2% of the spinal cord at RAO, and 6.1% of left kidney at LAO with DSA and 9.3% of the stomach with CT. The combined organ dose (4 DSAs and 6 CT scans) with the use of actual patient conditions was found to be 197.4 mGy for the liver and 205.1 mGy for the spinal cord. Conclusion: Our method makes it possible to accurately assess the organ dose to patients for abdominal intervention with combined DSA and CT.

60 APPLIED LIFE SCIENCES↗

WE-FG-202-02: Exploration of High-Resolution Quantitative Ultrasonic Micro-Vascular Imaging for Early Assessment of Radiotherapy Tumor Response

Purpose: Currently, we cannot predict an individual patient’s response to a given radiotherapy which normally is not detected for weeks to months post-treatment. As a result, precious time is wasted for patients with unresponsive tumors who could have switched to an alternative treatment much earlier. Presently, no early treatment response detection method exists that is effective, low-cost, non-invasive, and safe. We hypothesize that changes in tumor microvasculature predict tumor response to radiotherapy earlier than tumor volume changes. Recent radiobiology research suggests tumors undergo vascular remodeling in response to radiation well before manifesting changes in tumor volume. We propose monitoring tumor microvasculature post-radiation using Acoustic Angiography (AA), a novel ultrasound imaging modality developed and patented in-house. In this study, we investigate whether changes in tumor microvasculature, measured using AA, can be an early indicator of high-dose radiotherapy success, compared to changes in tumor volume. Methods: Fibrosarcoma xenograft tumor tissue was subcutaneously implanted into rodent flanks (N=10). Animal tumors (N=8) were irradiated with a single treatment of 15Gy using a clinical LINAC at 100SSD and 2×2cm field size. Two untreated rats were left as tumor controls. AA imaging was performed immediately posttreatment and every third day thereafter for 30 days, or until tumors disappeared. Tumor volumes and vascular densities were measured from anatomical b-mode ultrasound and AA images, respectively. Results: Statistical differences in vascular density between treatment responders and non-responders were observed on Day 10 (p=0.005), whereas statistical differences in tumor volume were not observed until Day 19 (p=0.02). Conclusions: Tumor vascularity differences may be observed substantially earlier than differences in tumor size. In addition, significant early increases in vascular density were observed in non-responding tumors. This data is consistent with a similar study we completed using the same tumor and animal models (N=10) at 20Gy. The project described was supported by the National Center for Advancing Translational Sciences (NCATS), National Institutes of Health, through Grant Award Number UL1TR001111. The content is solely the responsibility of the authors and does not necessarily represent the official views of the NIH.

60 APPLIED LIFE SCIENCES↗

TH-AB-207A-03: Skin Dose to Patients Receiving Multiple CTA and CT Exams of the Head

Purpose: To measure patient skin dose from CT angiography (CTA) and CT exams of the head, and determine if patients having multiple exams could receive cumulative doses that approach or exceed deterministic thresholds. Methods: This study was HIPAA compliant and conducted with IRB approval. Patient skin doses were measured over a 4 month period using nanoDot OSL dosimeters placed on the head of 52 patients for two CT scanners. On each scanner, 26 patients received CT exams (scanner 1: 10 females, 16 males, mean age 64.2 years; scanner 2: 18 females, 8 males, mean age 61.2 years). CT exam dose metrics, CTDIvol and dose-length product (DLP) were recorded for each exam. Additionally, skin dose was measured on an acrylic skull phantom in each scanner and on a neuro-interventional imaging system using clinical protocols. Measured dose data was used to estimate peak skin dose (PSD) for 4 patients receiving multiple exams including CTA, head CT, and cerebral angiography. Results: For scanner 1, the mean PSD for CTA exams (98.9 ± 5.3 mGy) and for routine head CT exams (39.2 ± 3.7 mGy) agreed reasonably well with the PSD measured on the phantom, 105.4 mGy and 40.0 mGy, respectively. Similarly for scanner 2, the mean PSD for CTA exams (98.8 ± 7.4 mGy) and for routine head CT exams (42.9 ± 9.4 mGy) compared well with phantom measurements, 95.2 mGy and 37.6 mGy, respectively. In addition, the mean PSD was comparable between scanners for corresponding patient exams, CTA and routine head CT respectively. PSD estimates ranged from 1.9 – 4.5 Gy among 4 patients receiving multiple exams. Conclusion: Patients having several exams including both CTA and routine head CT may receive cumulative doses approaching or exceeding the threshold for single dose deterministic effects.

60 APPLIED LIFE SCIENCES↗

TH-F-209-00: Pitfalls: Reliability and Performance of Diagnostic X-Ray Sources

Purpose: Performance and reliability of medical X-ray tubes for imaging are crucial from an ethical, clinical and economic perspective. This lecture will deliver insight into the aspects to consider during the decision making process to invest in X-ray imaging equipment. Outdated metric still hampers realistic product comparison. It is time to change this and to comply with latest standards, which consider current technology. Failure modes and ways to avoid down-time of the equipment shall be discussed. In view of the increasing number of interventional procedures and the hazards associated with ionizing radiation, toxic contrast agents, and the combination thereof, the aspect of system reliability is of paramount importance. Methods: A comprehensive picture of trends for different modalities (CT, angiography, general radiology) has been drawn and led to the development of novel X-ray tube technology. Results: Recent X-ray tubes feature enhanced reliability and unprecedented performance. Relevant metrics for product comparison still have to be implemented in practice. Conclusion: The speed of scientific and industrial development of new diagnostic and therapeutic X-ray sources remains tremendous. Still, users suffer from gaps between desire and reality in day-to-day diagnostic routine. X-ray sources are still limiting cutting-edge medical procedures. Side-effects of wear and tear, limitations of the clinical work flow, costs, the characteristics of the X-ray spectrum and others topics need to be further addressed. New applications and modalities, like detection-based color-resolved X-ray and phase-contrast / dark-field imaging will impact the course of new developments of X-ray sources. Learning Objectives: Understand the basic requirements on medical diagnostic X-ray sources per modality Learn to select the optimal equipment employing state-of-the-art metric Know causes of failures, depending on the way X-ray sources are operated Understand methods to remediate critical situations Understand the meaning of different warranty models I am employee of Royal Philips; R. Behling, No external funding. I am employee of Royal Philips.

61 RADIATION PROTECTION AND DOSIMETRY↗

TH-F-209-01: Pitfalls: Reliability and Performance of Diagnostic X-Ray Sources

Purpose: Performance and reliability of medical X-ray tubes for imaging are crucial from an ethical, clinical and economic perspective. This lecture will deliver insight into the aspects to consider during the decision making process to invest in X-ray imaging equipment. Outdated metric still hampers realistic product comparison. It is time to change this and to comply with latest standards, which consider current technology. Failure modes and ways to avoid down-time of the equipment shall be discussed. In view of the increasing number of interventional procedures and the hazards associated with ionizing radiation, toxic contrast agents, and the combination thereof, the aspect of system reliability is of paramount importance. Methods: A comprehensive picture of trends for different modalities (CT, angiography, general radiology) has been drawn and led to the development of novel X-ray tube technology. Results: Recent X-ray tubes feature enhanced reliability and unprecedented performance. Relevant metrics for product comparison still have to be implemented in practice. Conclusion: The speed of scientific and industrial development of new diagnostic and therapeutic X-ray sources remains tremendous. Still, users suffer from gaps between desire and reality in day-to-day diagnostic routine. X-ray sources are still limiting cutting-edge medical procedures. Side-effects of wear and tear, limitations of the clinical work flow, costs, the characteristics of the X-ray spectrum and others topics need to be further addressed. New applications and modalities, like detection-based color-resolved X-ray and phase-contrast / dark-field imaging will impact the course of new developments of X-ray sources. Learning Objectives: Understand the basic requirements on medical diagnostic X-ray sources per modality Learn to select the optimal equipment employing state-of-the-art metric Know causes of failures, depending on the way X-ray sources are operated Understand methods to remediate critical situations Understand the meaning of different warranty models I am employee of Royal Philips; R. Behling, No external funding. I am employee of Royal Philips.

61 RADIATION PROTECTION AND DOSIMETRY↗

Visualization of plasma-induced processes by a projection system with a Cu-laser-based brightness amplifier

A novel method for visualization of the process of interaction of high-power energy fluxes with various surfaces is proposed. The possibility of the dynamic visualization of a surface covered with a {approx}3-cm-thick plasma layer with a linear density of {approx}10{sup 16} cm{sup -2} is demonstrated experimentally. A scheme of intracavity shadowgraphy of phase objects with the use of a laser projection microscope is developed. Shadow images illustrating the development of the plasma torch of an erosion capillary discharge in air are presented.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Tumor Resection Guided by Intraoperative Indocyanine Green Dye Fluorescence Angiography Results in Negative Surgical Margins and Decreased Local Recurrence in an Orthotopic Mouse Model of Osteosarcoma

Background: Surgical resection with negative margins is the foundation of extremity sarcoma management. Failure to achieve negative surgical margins can result in local recurrence (LR), a potentially devastating complication. Indocyanine green (ICG) is a US FDA-approved fluorophore previously used to guide carcinoma resections. We investigated the potential of ICG as an intraoperative guide during experimental sarcoma resection. Methods: Fifty 6-week-old immunocompetent Balb/c female mice received left proximal tibia paraphyseal injections of 5 × 10{sup 5} K7M2 murine osteosarcoma cells. Animals were separated into two groups (n = 25 each): (1) ICG-assisted surgical resection; and (2) no ICG-assisted resection. Resections were performed 4 weeks after primary tumor engraftment. All animals received 7.5 ug ICG via retro-orbital injection 12 h prior to surgery. ICG fluorescence measurements and clinical evaluations were performed 4 weeks after resection to detect LR. Results: Eleven of 25 animals from each group developed gross tumors. Four weeks after resection, group 1 had 0/11 tumor recurrences, while group 2 had recurrences in 9/11 (81.8%) experimental mice (p < 0.0002) (Fig. 2). There was a 100% NPV in group 1, and no tumor recurrence with fluorescence-free margins after the primary surgery. Group 2 had a 100% positive predictive value for the development of an LR if any fluorescent signal was present at the surgical margin after resection. Conclusion: Intraoperative ICG guidance led to reliably negative surgical margins and a diminished LR rate. Given the benign safety profile of ICG and its prior clinical success, these results could be immediately translatable to the clinical realm.

60 APPLIED LIFE SCIENCES↗

Intraoperative Fluorescent Angiography Predicts Pharyngocutaneous Fistula After Salvage Laryngectomy

Background: Technology to assess tissue perfusion is exciting with translational potential, although data supporting its clinical applications have been lagging. Patients who have undergone radiation are at particular risk of poor tissue perfusion and would benefit from this expanding technology. We designed a prospective clinical trial using intraoperative indocyanine green angiography to evaluate for wound-healing complications in patients undergoing salvage laryngectomy after radiation failure. Patients and Methods: This prospective trial included patients undergoing salvage laryngectomy at a National Cancer Institute-designated tertiary cancer center between 2016 and 2018. After tumor extirpation and prior to reconstruction, 10 mg indocyanine green dye was infused and the fluorescence (F{sub HYPO}) and ingress rate of the pharyngeal mucosa recorded. The primary outcome measure was formation of a pharyngocutaneous fistula (PCF). Results: Patients who developed a PCF had significantly lower F{sub HYPO} (87 vs 172, p < 0.001) and ingress rates (6.7 vs 15.8, p = 0.043) compared with those who did not develop a fistula. There were no fistulas in patients with F{sub HYPO} > 150 (n = 21) or ingress > 15 (n = 15). There was a 50% fistula rate in patients with F{sub HYPO} ≤ 103 (n = 10) and ingress rate ≤ 6 (n = 6). Conclusions: Intraoperative indocyanine green angiography can assess hypoperfusion in patients and predict risk of PCFs after salvage laryngectomy, and can thus intraoperatively risk-stratify patients for postoperative wound-healing complications.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Optimizing probe design for an implantable perfusion and oxygenation sensor

In an effort to develop an implantable optical perfusion and oxygenation sensor, based on multiwavelength reflectance pulse oximetry, we investigate the effect of source detector separation and other source-detector characteristics to optimize the sensor s signal to background ratio using Monte Carlo (MC) based simulations and in vitro phantom studies. Separations in the range 0.45 to 1.25 mm were found to be optimal in the case of a point source. The numerical aperture (NA) of the source had no effect on the collected signal while the widening of the source spatial profile caused a shift in the optimal source-detector separation. Specifically, for a 4.5 mm flat beam and a 2.4 mm 2.5 mm photodetector, the optimal performance was found to be when the source and detector are adjacent to each other. These modeling results were confirmed by data collected from in vitro experiments on a liver phantom perfused with dye solutions mimicking the absorption properties of hemoglobin for different oxygenation states.

59 BASIC BIOLOGICAL SCIENCES↗

Effect of Antigen Shedding on Targeted Delivery of Immunotoxins in Solid Tumors from a Mathematical Model

Most cancer-specific antigens used as targets of antibody-drug conjugates and immunotoxins are shed from the cell surface (Zhang & Pastan (2008) Clin. Cancer Res. 14: 7981-7986), although at widely varying rates and by different mechanisms (Dello Sbarba & Rovida (2002) Biol. Chem. 383: 69–83). Why many cancer-specific antigens are shed and how the shedding affects delivery efficiency of antibody-based protein drugs are poorly understood questions at present. Before a detailed numerical study, it was assumed that antigen shedding would reduce the efficacy of antibody-drug conjugates and immunotoxins. However, our previous study using a comprehensive mathematical model showed that antigen shedding can significantly improve the efficacy of the mesothelin-binding immunotoxin, SS1P (anti-mesothelin-Fv-PE38), and suggested that receptor shedding can be a general mechanism for enhancing the effect of inter-cellular signaling molecules. Here, we improved this model and applied it to both SS1P and another recombinant immunotoxin, LMB-2, which targets CD25. We show that the effect of antigen shedding is influenced by a number of factors including the number of antigen molecules on the cell surface and the endocytosis rate. The high shedding rate of mesothelin is beneficial for SS1P, for which the antigen is large in number and endocytosed rapidly. On the other hand, the slow shedding of CD25 is beneficial for LMB-2, for which the antigen is small in number and endocytosed slowly.

60 APPLIED LIFE SCIENCES↗

Science & Technology Review May/June 2008

This month's issue has the following articles: (1) Biomedical Technology Has a Home at Livermore--Commentary by Cherry A. Murray; (2) Shaping the Future of Aneurysm Treatments--Livermore foam devices may offer significant advantages for treating some forms of aneurysms; (3) Ring around a Stellar Shell: A Tale of Scientific Serendipity--Using a three-dimensional model, Livermore scientists have solved a long-standing puzzle of stellar evolution; and (4) On Assignment in Washington, DC--Livermore personnel in Washington, DC, support federal sponsors and become valuable assets to Laboratory programs.

59 BASIC BIOLOGICAL SCIENCES↗

Hydroelastic effects in the aorta bifurcation zone

The mechanical behavior of the vessels and blood is mathematically analyzed at the point of aortic bifurcation using a homogeneous single layer channel as a model of the aorta. Allowance is made for the fact that the aortic intima is considerably less rigid than the other layers. For analysis of blood flow in the major arteries, the blood is treated as a viscous Newtonian fluid whose movements are described by Navier-Stokes equations and a continuity equation. Blood flow dynamics at the aortic bifurcation are discussed on the basis of the results.

Volmir, A. S.↗

The effect of interstitial air on the in vitro thrombogenicity of ePTFE vascular grafts

Gas trapped in the interstices of the biomaterials used for vascular prostheses causes thrombosis, and the process of eliminating this gas is known as denucleation. An apparatus was developed for testing in the in vitro effects of denucleation on 4 mm I.D. expanded polytetrafluoroethylene (ePTFE) Vitagraft (Johnson and Johnson). The apparatus was designed to ensure that neither the blood nor the grafts came in contact with air. Blood from a single donor was incubated with control and denucleated grafts for 5, 10, 15, 20, and 30 minutes. The thrombus volume in the graft lumen was measured with a computer assisted videometric system. Little thrombus formed by 5 or 10 minutes, but there was less thrombus in the denucleated graft than in the control graft at all times. The differences were statistically significant at 15 and 20 minutes (p < 0.05). Denucleation nearly doubled the thrombus formation time. Thrombus was more adherent to denucleated grafts than to control grafts. These results are consistent with in vivo observations in the rat where denucleation decreased thrombus formation and increased patency duration.

NASA Discipline Number 04-10↗

Losartan attenuates chronic cigarette smoke exposure-induced pulmonary arterial hypertension in rats: Possible involvement of angiotensin-converting enzyme-2

Chronic cigarette smoking induces pulmonary arterial hypertension (PAH) by largely unknown mechanisms. Renin-angiotensin system (RAS) is known to function in the development of PAH. Losartan, a specific angiotensin II receptor antagonist, is a well-known antihypertensive drug with a potential role in regulating angiotensin-converting enzyme-2 (ACE2), a recently found regulator of RAS. To determine the effect of losartan on smoke-induced PAH and its possible mechanism, rats were daily exposed to cigarette smoke for 6 months in the absence and in the presence of losartan. Elevated right ventricular systolic pressure (RVSP), thickened wall of pulmonary arteries with apparent medial hypertrophy along with increased angiotensin II (Ang II) and decreased ACE2 levels were observed in smoke-exposed-only rats. Losartan administration ameliorated pulmonary vascular remodeling, inhibited the smoke-induced RVSP and Ang II elevation and partially reversed the ACE2 decrease in rat lungs. In cultured primary pulmonary artery smooth muscle cells (PASMCs) from 3- and 6-month smoke-exposed rats, ACE2 levels were significantly lower than in those from the control rats. Moreover, PASMCs from 6-month exposed rats proliferated more rapidly than those from 3-month exposed or control rats, and cells grew even more rapidly in the presence of DX600, an ACE2 inhibitor. Consistent with the in vivo study, in vitro losartan pretreatment also inhibited cigarette smoke extract (CSE)-induced cell proliferation and ACE2 reduction in rat PASMCs. The results suggest that losartan may be therapeutically useful in the chronic smoking-induced pulmonary vascular remodeling and PAH and ACE2 may be involved as part of its mechanism. Our study might provide insight into the development of new therapeutic interventions for PAH smokers.

60 APPLIED LIFE SCIENCES↗

Rationale for and Preliminary Results of Proton Beam Therapy for Mediastinal Lymphoma

Purpose: To evaluate the potential of three-dimensional proton beam therapy (3D-PBT) for reducing doses to normal structures in patients with mediastinal lymphomas compared with conventional photon radiation therapy (RT). Methods and Materials: We treated 10 consecutive patients with mediastinal masses from lymphomas with 3D-PBT between July 2007 and February 2009 to 30.6-50.4 cobalt-Gray equivalents (CGE). Of those patients, 7 had primary refractory or recurrent disease, and 8 had Hodgkin lymphoma. Dosimetric endpoints were compared with those from conventional RT plans. Results: PBT delivered lower mean doses to the lung (6.2 vs. 9.5 Gy), esophagus (9.5 vs. 22.3 Gy), and heart (8.8 vs. 17.7 Gy) but not the breasts (5.9 vs. 6.1 Gy) than did conventional RT. Percentages of lung, esophagus, heart, and coronary artery (particularly the left anterior descending artery) volumes receiving radiation were consistently lower in the 3D-PBT plans over a wide range of radiation doses. Of the 7 patients who had residual disease on positron emission tomography before PBT, 6 (86%) showed a complete metabolic response. Conclusions: In patients with mediastinal lymphomas, 3D-PBT produced significantly lower doses to the lung, esophagus, heart, and coronary arteries than did the current conventional RT. These lower doses would be expected to reduce the risk of late toxicities in these major organs.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Investigation of P(VDF-TrFE)/ZrO{sub 2}-MMA polymer composites applied to radiation shielding

Exposure to high radiation dose in medical diagnostic imaging procedures can lead patients to suffer tissue damaging. However, there are several studies that identify significant dose reduction with the use of radiation protective attenuators, minimizing the delivered dose in the region that covers the main beam, while preserving the diagnostic quality of the generated image. Most radiation attenuator materials are produced from shielding metal containing composites, whose efficiency is the goal of investigations around the world. In this context, polymeric materials were chosen for this investigation in order to provide light-weighted and flexible protective composites, a must in personal protective shielding. Therefore, this work is concerned to the investigation of poly(vinylidene fluoride - try-fluor-ethylene) [P(VDF-TrFE)] copolymers mixed with zirconia nanoparticles. The resulting polymer composites, prepared with 1, 2, 3, 5 and 10 at.% of ZrO{sub 2} nanoparticles, were investigated for application as protective shielding in some interventional radiology procedures. Two variety of composites were produced, one using pure ZrO{sub 2} nanoparticles and the other using sol-gel route with zirconium butoxide as the precursor for zirconium oxide nano-clusters. The P(VDFTrFE)/ ZrO2-MMA polymer composites produced by sol-gel route have provided a much better dispersion of the pure ZrO{sub 2} material into the P(VDF-TrFE) host matrix. UV-Vis and FTIR spectrometry and differential scanning calorimetry (DSC) were used to characterize the composite samples. FTIR data reveal a possible link between the MMA monomers with the P(VDF-TrFE) chain through shared C=O bonds. The radiation shielding characterization was conducted by using a 70 kV x-rays beam which is applicable, for instances, in catheter angiography. The results demonstrate that composites with 10% of ZrO{sub 2}, and only 1.0 mm thick, can attenuate 60% of the x-rays beam. The composite density was evaluated to be 2.20 g/cm{sup 3}. The results indicate that P(VDF-TrFE)/ZrO{sub 2}-MMA polymer composites have potential to be investigated as light-weighted and flexible protective shielding for application in some radiological procedures that uses low kilovoltage x-ray beams. (authors)

36 MATERIALS SCIENCE↗