Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “BEAM PROFILES”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,153 records · Page 64

SIMULATIONS OF THE MG ii K AND CA ii 8542 LINES FROM AN ALFVÉN WAVE-HEATED FLARE CHROMOSPHERE

We use radiation hydrodynamic simulations to examine two models of solar flare chromospheric heating: Alfvén wave dissipation and electron beam collisional losses. Both mechanisms are capable of strong chromospheric heating, and we show that the distinctive atmospheric evolution in the mid-to-upper chromosphere results in Mg ii k-line emission that should be observably different between wave-heated and beam-heated simulations. We also present Ca ii 8542 Å profiles that are formed slightly deeper in the chromosphere. The Mg ii k-line profiles from our wave-heated simulation are quite different from those from a beam-heated model and are more consistent with Interface Region Imaging Spectrograph observations. The predicted differences between the Ca ii 8542 Å in the two models are small. We conclude that careful observational and theoretical study of lines formed in the mid-to-upper chromosphere holds genuine promise for distinguishing between competing models for chromospheric heating in flares.

79 ASTRONOMY AND ASTROPHYSICS↗

Simple dynamic electromagnetic radiation detector

Detector monitors gamma dose rate at particular position in a radiation facility where a mixed neutron-gamma environment exists, thus determining reactor power level changes. Device also maps gamma intensity profile across a neutron-gamma beam.

Been, J. F.↗

Measurements of the sampling volume of an infrared laser doppler velocimeter for the study of feasibility of simultaneous three-dimensional velocity profile mapping

High resolution incoherent mapping of the sampling volume was performed to determine the three dimensional profile of the volume of the beam from which information can be obtained by scattering. The incoherent sampling volume of the infrared laser Doppler velocimeter was found to be heavily dependent upon the configuration of the outgoing laser beam. In general when only half the beam is allowed to focus at the focal plane, the x, y traverses indicate a broader beam with nominal side lobes. However, if the total beam is permitted to impinge on the focal plane there is substantial narrowing of the beam with increased maximum intensity and an increase in side lobes. The double maximum indicated by the coherent sampling volume appears to be an artifact of the scanning process not a fundamental entity of the sampling volume.

Bond, R. L.↗

Description and evaluation of the Acoustic Profiling of Ocean Currents (APOC) system used on R. V. Oceanus cruise 96 on 11-22 May 1981

The underway current profiling system which consists of a microprocessor controlled data logger that collects and formats data from a four beam Ametek-Straza 300 kHz acoustic Doppler current profiler, heading from the ship's gyrocompass, and navigation information from a Loran-C receiver and a satellite navigation unit is discussed. Data are recorded on magnetic tape and real time is calculated. Time averaging is required to remove effects of ship motion. An intercomparison is made with a moored vector measuring current meter (VMCM). The mean difference in hourly averaged APOC and VMCM currents over the four hour intercomparison is a few mm s minus including: two Gulf Stream crossings, a warm core ring survey, and shallow water in a frontal zone to the east of Nantucket Shoals.

Joyce, T. M.↗

Wind profile estimation from point to point laser distortion data

The author's results on the problem of using laser distortion data to estimate the wind profile along the path of the beam are presented. A new model for the dynamics of the index of refraction in a non-constant wind is developed. The model agrees qualitatively with theoretical predictions for the index of refraction statistics in linear wind shear, and is approximated by the predictions of Taylor's hypothesis in constant wind. A framework for a potential in-flight experiment is presented, and the estimation problem is discussed in a maximum likelihood context.

Leland, Robert↗

Millimeter-wave/infrared rectenna development at Georgia Tech

The key design issues of the Millimeter Wave/Infrared (MMW/IR) monolithic rectenna have been resolved. The work at Georgia Tech in the last year has focused on increasing the power received by the physically small MMW rectennas in order to increase the rectification efficiency. The solution to this problem is to place a focusing element on the back side of the substrate. The size of the focusing element can be adjusted to help maintain the optimum input power density not only for different power densities called for in various mission scenarios, but also for the nonuniform power density profile of a narrow EM-beam.

Gouker, Mark A.↗

Computational Nonlinear of Vertical-Cavity Surface-Emitting Lasers

Vertical-Cavity Surface-Emitting Lasers (VCSELs) have become increasingly important for many applications, such as optical interconnects and optical data storages. In many applications, critical requirements are very often high beam quality and/or high output powers. To help the design and optimization of VCSELs for such applications, it is essential to have a simulation model that includes the time evolution of the transverse space dependence of the beam. Such models allow arbitrary transverse profiles of laser intensity or carrier density to develop in time without any a priori assumption about the number and types of transverse modes. In addition, extensive research in the past has shown that many-body effects are important in influencing the optical gain and the refractive index of semiconductor quantum wells. It is thus important to include the key many-body effects in simulation models for semiconductor lasers. A computational model, called the Maxwell-Effective Bloch Equations (MEBE) was developed recently that simulates the above features and effects. This model combines the space-time resolution with microscopic many-body effects in a way that is both accurate enough and computationally manageable. This model has been used to simulate edge-emitting high power lasers recently. A new finite-difference algorithm has been developed for solving these equations and will be shown in the presentation. That algorithm will be used to calculate the detailed time evolution of the transverse mode profiles of VCSELs. The VCSELs are based on InGaAs/GaAs quantum well structures. Effects of pumping current and refractive index profiles will be investigated in detail. The simulation results will be compared with other results the use the rate-equation model.

Goorjian, Peter M.↗

Ground Radar Polarimetric Observations of High-Frequency Earth-Space Communication Links

Strategic roadmaps for NASA's Human Exploration and Development of Space (REDS) enterprise support near-term high-frequency communication systems that provide moderate to high data rates with dependable service. Near-earth and human planetary exploration will baseline Ka-Band, but may ultimately require the use of even higher frequencies. Increased commercial demand on low-frequency earth-space bands has also led to increased interest in the use of higher frequencies in regions like K u - and K,- band. Data is taken from the Tropical Rainfall Measuring Mission (TRMM) Precipitation Radar (PR), which operates at 13.8 GHz, and the true radar reflectivity profile is determined along the PR beam via low-frequency ground based polarimetric observations. The specific differential phase (Kdp) is measured along the beam and a theoretical model is used to determine the expected specific attenuation (k). This technique, called the k-Kdp method, uses a Fuzzy-Logic model to determine the hydrometeor type along the PR beam from which the appropriate k-Kdp relationship is used to determine k and, ultimately, the total path-integrated attenuation (PIA) on PR measurements. Measurements from PR and the NCAR S-POL radar were made during the TEFLUN-B experiment that took place near Melbourne, FL in 1998, and the TRMM-LBA campaign near Ji-Parana, Brazil in 1999.

Bolen, Steve↗

Simulations of the Mg II K and Ca II 8542 Lines From an Alfvén Wave-Heated Flare Chromosphere

We use radiation hydrodynamic simulations to examine two models of solar flare chromospheric heating: Alfven wave dissipation and electron beam collisional losses. Both mechanisms are capable of strong chromospheric heating, and we show that the distinctive atmospheric evolution in the mid-to-upper chromosphere results in Mg II k-line emission that should be observably different between wave-heated and beam-heated simulations. We also present Ca II 8542 A profiles that are formed slightly deeper in the chromosphere. The Mg II k-line profiles from our wave-heated simulation are quite different from those from a beam-heated model and are more consistent with Interface Region Imaging Spectrograph observations. The predicted differences between the Ca II 8542 A in the two models are small. We conclude that careful observational and theoretical study of lines formed in the mid-to-upper chromosphere holds genuine promise for distinguishing between competing models for chromospheric heating inflares.

Kerr, Graham S.↗

A LASER INTERFERENCE-BASED SURFACE TREATMENT OF AL AND CARBON FIBER POLYMER COMPOSITES FOR ENHANCED BONDING

Due to its increased use in the automotive and aerospace industries, joining of Carbon Fiber-reinforced Polymer matrix Composites (CFPC) to metals demands enhanced surface preparation and control of surface morphology prior to joining. In this study, surfaces of both composite and aluminum were prepared for joining using a new laser based technique, in which the laser interference power profile was created by splitting the beam and guiding those beams to the sample surface by overlapping each other with defined angles to each other. Results were presented for the overlap shear testing of single-lap joints made with Al 5182 and CFPC specimens whose surfaces prepared by (a) surface abrasion and solvent cleaning; and (b) laser-interference structured surfaces by rastering with a 4 mm laser beam at approximately 3.5 W power. CFPC specimens of T700S carbon fiber, Prepreg T70 epoxy, 4 or 5 ply thick, 0/90o plaques were used. Adhesive DP810 was used to bond Al and CFPC. The bondline was 0.25mm and the bond length was consistent among all joints produced. First, the effect of the laser speed on the joint performance was evaluated by laser-interference structure Al and CFPC surfaces with a beam angle of 3o and laser beam speeds of 3, 5, and 10 mm/s. For this sensitivity study, 3 joint specimens were used per each joint type. Based on the results for minimum, maximum, and mean values for the shear lap strength and maximum load for all the 9 joint types, two joint types were selected for further evaluations. Six additional joint specimens were prepared for these two joint types in order to obtain better statistics and the shear test data was presented for the range, mean, and standard deviation. The results for the single-lap shear tests obtained for six joint specimens, indicate that the shear lap strength, maximum load, and displacement at maximum load for those joints made with laser-interference structured surfaces were increased by approximately 14.8%, 16%, and 100%, respectively over those measured for the baseline joints.

Sabau, Adrian S↗

CORROSION RESISTANCE OF LASER-INTERFERENCE STRUCTURED ALUMINUM ALLOY 2024 COATED WITH MIL-PRF-85582 PRIMER

The use of aluminum alloys in aerospace industry requires more effective and reliable joining techniques. The lubricant contaminants from prior rolling operations affect surface energies and the quality of coating adhe-sion and adhesive bonded joints. In this study, a new laser-based technique is investigated as a surface treatment for coating applications. The laser interference power profile was created by splitting the beam and guiding both beams towards the specimen and overlapping them on the specimen surface, creating a line-interference pattern on the specimen surface. The laser-interference structuring (LIS) was used without any chemical treatments, such as those in chemical conversion coating (CCC) and sulfuric acid anodizing (SAA), which is a much simpler process than those chemical-based. To assess the effect of LIS on corrosion re-sistance of coating, Al 2024 panels prepared by LIS, CCC and SAA were coated with MIL-PRF-85582, Type I, Class N primer and exposed to salt spray environment according to ASTM B117. The exposure is currently in progress and the corrosion attack on the coated panels will be evaluated by the degree of blister formation and rust creepage.

Sabau, Adrian↗

Machine learning for slow-extraction uniformity at the Fermilab Delivery Ring

The Muon-to-Electron Conversion Experiment (Mu2e) requires uniform slow extraction from the Fermilab Delivery Ring during each 43 ms spill. This project analyzed 13,737 spills from seven parquet files collected during March and June 2026 commissioning. Each spill contained 430 samples at 0.1 ms resolution and was summarized by the Spill Duty Factor. Null Action and active proportional-integral-derivative conditions established operational baselines. Fixed-ramp sessions were segmented to evaluate reproducibility, drift, and spill-to-spill spread, while a deliberate quadrupole-ramp step identified the beam-response peak and trough. Median profiles were reproducible within fixed conditions but drifted over multi-hour periods. The resulting baselines and response features support future physics-based and machine-learning approaches to real-time spill regulation.

Prescott, Matthew J. [Purdue U., West Lafayette; F↗

SU-F-BRD-08: A Novel Technique to Derive a Clinically-Acceptable Beam Model for Proton Pencil-Beam Scanning in a Commercial Treatment Planning System

Purpose: To evaluate the accuracy and limitations of a commercially-available treatment planning system’s (TPS’s) dose calculation algorithm for proton pencil-beam scanning (PBS) and present a novel technique to efficiently derive a clinically-acceptable beam model. Methods: In-air fluence profiles of PBS spots were modeled in the TPS alternately as single-(SG) and double-Gaussian (DG) functions, based on fits to commissioning data. Uniform-fluence, single-energy-layer square fields of various sizes and energies were calculated with both beam models and delivered to water. Dose was measured at several depths. Motivated by observed discrepancies in measured-versus-calculated dose comparisons, a third model was constructed based on double-Gaussian parameters contrived through a novel technique developed to minimize these differences (DGC). Eleven cuboid-dose-distribution-shaped fields with varying range/modulation and field size were subsequently generated in the TPS, using each of the three beam models described, and delivered to water. Dose was measured at the middle of each spread-out Bragg peak. Results: For energies <160 MeV, the DG model fit square-field measurements to <2% at all depths, while the SG model could disagree by >6%. For energies >160 MeV, both SG and DG models fit square-field measurements to <1% at <4 cm depth, but could exceed 6% deeper. By comparison, disagreement with the DGC model was always <3%. For the cuboid plans, calculation-versus-measured percent dose differences exceeded 7% for the SG model, being larger for smaller fields. The DG model showed <3% disagreement for all field sizes in shorter-range beams, although >5% differences for smaller fields persisted in longer-range beams. In contrast, the DGC model predicted measurements to <2% for all beams. Conclusion: Neither the TPS’s SG nor DG models, employed as intended, are ideally suited for routine clinical use. However, via a novel technique to be presented, its DG model can be tuned judiciously to yield acceptable results.

60 APPLIED LIFE SCIENCES↗

Focussing Protons from a Kilojoule Laser for Intense Beam Heating Using Proximal Target Structures

Proton beams driven by chirped pulse amplified lasers have multi-picosecond duration and can isochorically and volumetrically heat material samples, potentially providing an approach for creating samples of warm dense matter with conditions not present on Earth. Envisioned on a larger scale, they could heat fusion fuel to achieve ignition. We have shown in an experiment that a kilojoule-class, multi-picosecond short pulse laser is particularly effective for heating materials. The proton beam can be focussed via target design to achieve exceptionally high flux, important for the applications mentioned. The laser irradiated spherically curved diamond-like-carbon targets with intensity 4×10 18 W/cm 2 , producing proton beams with 3MeV slope temperature. A Cu witness foil was positioned behind the curved target, and the gap between was either empty or spanned with a structure. With a structured target, the total emission of Cu Kα fluorescence was increased 18 fold and the emission profile was consistent with a tightly focussed beam. Transverse proton radiography probed the target with ps order temporal and 10 μm spatial resolution, revealing the fast-acting focussing electric field. Complementary particle-in-cell simulations show how the structures funnel protons to the tight focus. The beam of protons and neutralizing electrons induce the bright Kα emission observed and heat the Cu to 100eV.

47 OTHER INSTRUMENTATION↗

Focussing Protons from a Kilojoule Laser for Intense Beam Heating using Proximal Target Structures

Proton beams driven by chirped pulse amplified lasers have multi-picosecond duration and can isochorically and volumetrically heat material samples, potentially providing an approach for creating samples of warm dense matter with conditions not present on Earth. Envisioned on a larger scale, they could heat fusion fuel to achieve ignition. We have shown in an experiment that a kilojoule-class, multi-picosecond short pulse laser is particularly effective for heating materials. The proton beam can be focussed via target design to achieve exceptionally high flux, important for the applications mentioned. The laser irradiated spherically curved diamond-like-carbon targets with intensity 4 × 10 18 W/cm 2 , producing proton beams with 3 MeV slope temperature. A Cu witness foil was positioned behind the curved target, and the gap between was either empty or spanned with a structure. With a structured target, the total emission of Cu Kα fluorescence was increased 18 fold and the emission profile was consistent with a tightly focussed beam. Transverse proton radiography probed the target with ps order temporal and 10 μm spatial resolution, revealing the fast-acting focussing electric field. Complementary particle-in-cell simulations show how the structures funnel protons to the tight focus. Here, the beam of protons and neutralizing electrons induce the bright Kα emission observed and heat the Cu to 100 eV.

47 OTHER INSTRUMENTATION↗

SU-F-T-155: Validation of a Commercial Monte Carlo Dose Calculation Algorithm for Proton Therapy

Purpose: Compare proton pencil beam scanning dose measurements to GATE/GEANT4 (GMC) and RayStation™ Monte Carlo (RMC) simulations. Methods: Proton pencil beam models of the IBA gantry at the Seattle Proton Therapy Center were developed in the GMC code system and a research build of the RMC. For RMC, a preliminary beam model that does not account for upstream halo was used. Depth dose and lateral profiles are compared for the RMC, GMC and a RayStation™ pencil beam dose (RPB) model for three spread out Bragg peaks (SOBPs) in homogenous water phantom. SOBP comparisons were also made among the three models for a phantom with a (i) 2 cm bone and a (ii) 0.5 cm titanium insert. Results: Measurements and GMC estimates of R80 range agree to within 1 mm, and the mean point-to-point dose difference is within 1.2% for all integrated depth dose (IDD) profiles. The dose differences at the peak are 1 to 2%. All of the simulated spot sigmas are within 0.15 mm of the measured values. For the three SOBPs considered, the maximum R80 deviation from measurement for GMC was −0.35 mm, RMC 0.5 mm, and RPB −0.1 mm. The minimum gamma pass using the 3%/3mm criterion for all the profiles was 94%. The dose comparison for heterogeneous inserts in low dose gradient regions showed dose differences greater than 10% at the distal edge of interface between RPB and GMC. The RMC showed improvement and agreed with GMC to within 7%. Conclusion: The RPB dosimetry show clinically significant differences (> 10%) from GMC and RMC estimates. The RMC algorithm is superior to the RPB dosimetry in heterogeneous media. We suspect modelling of the beam’s halo may be responsible for a portion of the remaining discrepancy and that RayStation will reduce this discrepancy as they finalize the release. Erik Traneus is employed as a Research Scientist at RaySearch Laboratories. The research build of the RayStation TPS used in the study was made available to the SCCA free of charge. RaySearch did not provide any monetary support other than a license to use the research build of the TPS.

60 APPLIED LIFE SCIENCES↗

Proton minibeam radiation therapy: Experimental dosimetry evaluation

Purpose: Proton minibeam radiation therapy (pMBRT) is a new radiotherapy (RT) approach that allies the inherent physical advantages of protons with the normal tissue preservation observed when irradiated with submillimetric spatially fractionated beams. This dosimetry work aims at demonstrating the feasibility of the technical implementation of pMBRT. This has been performed at the Institut Curie - Proton Therapy Center in Orsay. Methods: Proton minibeams (400 and 700 μm-width) were generated by means of a brass multislit collimator. Center-to-center distances between consecutive beams of 3200 and 3500 μm, respectively, were employed. The (passive scattered) beam energy was 100 MeV corresponding to a range of 7.7 cm water equivalent. Absolute dosimetry was performed with a thimble ionization chamber (IBA CC13) in a water tank. Relative dosimetry was carried out irradiating radiochromic films interspersed in a IBA RW3 slab phantom. Depth dose curves and lateral profiles at different depths were evaluated. Peak-to-valley dose ratios (PVDR), beam widths, and output factors were also assessed as a function of depth. Results: A pattern of peaks and valleys was maintained in the transverse direction with PVDR values decreasing as a function of depth until 6.7 cm. From that depth, the transverse dose profiles became homogeneous due to multiple Coulomb scattering. Peak-to-valley dose ratio values extended from 8.2 ± 0.5 at the phantom surface to 1.08 ± 0.06 at the Bragg peak. This was the first time that dosimetry in such small proton field sizes was performed. Despite the challenge, a complete set of dosimetric data needed to guide the first biological experiments was achieved. Conclusions: pMBRT is a novel strategy in order to reduce the side effects of RT. This works provides the experimental proof of concept of this new RT method: clinical proton beams might allow depositing a (high) uniform dose in a brain tumor located in the center of the brain (7.5 cm depth, the worst scenario), while a spatial fractionation of the dose is retained in the normal tissues in the beam path, potentially leading to a gain in tissue sparing. This is the first complete experimental implementation of this promising technique. Biological experiments are needed in order to confirm the clinical potential of pMBRT.

60 APPLIED LIFE SCIENCES↗

TH-C-18A-05: Characteristics and Accuracy of CT Radiation Profile Width Measurements Using Radiochromic Films

Purpose: To investigate the impact of several acquisition and image analysis factors on the accuracy of CT beam width measurement using Gafchromic XR-QA2 film and an off the shelf document scanner. Methods: The film was carefully placed at the iso-center and exposed at various x-ray beam energies (80–140 kVp), exposure levels (50–400 mAs), and nominal beam widths (1.25, 5, and 10 mm). Films were scanned on a RICOH MP3501 flat-bed document scanner using reflection mode and various spatial resolutions (100 to 600 dpi) and locations within the scanner bed. Radiation dose profiles were derived by converting the net reflection measurements to dose values (in mGy) through film calibration (which is also described here). The beam widths were characterized by the FWHM and FWTM of the dose profiles and the deviations from the hybrid reference standards were quantified. The impact of x-ray beam energy, exposure intensity, film calibration, and the uniformity and spatial resolution of the document scanner were investigated. Results: The uncertainties in both FWHM and FWTM caused by varying beam energy, exposure level, and scanner uniformity were all within approximately 5%. Increasing scanner spatial resolution increased the uncertainty in both FWHM and FWTM (R2 = 0.35–0.71), with the FWTM affected by more than five times than the FWHM (28% vs. 4.9%). When uncalibrated dose profiles were used, the FWHM and FWTM were over-estimated by as much as 11.6% and 7.6%, respectively. Narrower beam width was more sensitive to the film calibration than the wider one (R2 = 0.68 and 0.85 for the FWHM and FWTM, respectively). Conclusion: Measurement of CT beam width using Gafchromic XR-QA2 films is robust against x-ray energy, exposure level, and scanner uniformity. It can provide adequate accuracy for all practical purposes with appropriate film calibration and scanner spatial resolution (100 dpi or less)

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗