Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “ARTERIES”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,153 records · Page 64

Mid-Term Vascular Safety of Renal Denervation Assessed by Follow-up MR Imaging

Background/AimsRenal denervation (RDN) emerged as a treatment option for reducing blood pressure (BP) in patients with treatment-resistant hypertension (TRH). However, concerns have been raised regarding the incidence of late renal artery stenosis or thromboembolism after RDN. The goal of the current study was, therefore, to conduct a prospective clinical trial on the mid-term vascular integrity of the renal arteries and the perfusion of the renal parenchyma assessed by magnetic resonance imaging (MRI) in the follow-up after catheter-based RDN.MethodsIn our single-centre investigator initiated study, 51 patients with true TRH underwent catheter-based RDN using the Symplicity Flex{sup TM} catheter (Medtronic Inc., Palo Alto, CA). Follow-up MRI was performed at a median of 11 months (interquartile range 6–18 months) after RDN on a 1.5T MR unit. High-resolution MR angiography (MRA) and MRI results were compared to the baseline digital angiography of renal arteries obtained at time of RDN. In case of uncertainties (N = 2) catheter angiography was repeated.ResultsBoth office and 24-h ambulatory BP were significantly reduced 6 and 12 months after RDN. Renal function remained unchanged 6 and 12 months after RDN. In all patients, MRA excluded new or progression of pre-existing low grade renal artery stenosis as well as focal aneurysms at the sites of radiofrequency ablation. In none of the patients new segmental perfusion deficits in either kidney were detected on MRI.ConclusionsNo vascular or parenchymal complications after radiofrequency-based RDN were detected in 51 patients followed up by MRI.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Early- and Mid-term Results of the Chimney Technique in the Repair of Aortic Arch Pathologies

PurposeTo examine the safety, feasibility, and mid-term efficacy of the chimney technique for aortic arch pathologies.MethodsFrom February 2011 to December 2014, a total of 35 patients (30 men; mean age 54.3 ± 14.1 years) with aortic arch pathologies underwent thoracic endovascular aortic repair combined with chimney stents. The indication was a proximal landing zone <1.5 cm. Follow-up was performed at 3, 6, and 12 months and then yearly thereafter.ResultsA total of 36 chimney stents were deployed (innominate artery, n = 1; left common carotid artery, n = 9; right subclavian artery, n = 1; left subclavian artery, n = 25). The technical success rate was 94.3 % (33/35). Immediate type Ia endoleaks (ELIa) were observed in two patients (8.6 %, 2/35). Twenty-five patients were successfully followed-up for a median period of 29.3 months (range, 6–48 months). One patient died due to aortic dissection aneurysm rupture at 36 months (mortality rate of 4 %, 1/25). Three late ELIa were observed and no reinterventions were performed. The overall incidence of ELIa was 20 % (5/25). During follow-up, the patency rate for chimney stents was 92 % (23/25).ConclusionOur limited experience demonstrates that the chimney technique is a viable and relatively safe treatment for patients with challenging thoracic aortic pathologies at least in the mid-term follow-up period.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Proximal Occlusion of Medium-Sized Vessels with the Penumbra Occlusion Device: A Study of Safety and Efficacy

PurposeTo retrospectively investigate the safety and efficacy of hybrid proximal coiling of various medium-sized vessels (4 to 8 mm) using the Penumbra Occlusion Device (POD).Materials and MethodsFrom October 2014 to February 2016, 37 proximal embolizations were performed with PODs in 36 patients (mean age: 50.8, range: 10–86; 29 male, 7 female). Vessel occlusions were achieved under fluoroscopic guidance using a 2.7 French microcatheter. Among the 36 vessels targeted, 16 were splenic arteries, 11 renal arteries, 4 mesenteric arteries, 3 arteriovenous fistulae, 1 iliac artery, and 1 gonadal vein. Intermittent follow-up angiography was performed to assess the flow for final occlusion. Outcomes and complications were assessed by clinical and/or imaging follow-up.ResultsTo produce proximal occlusion of the intended vessels, the POD was used alone in 19 embolizations (51.4 %). In 12 procedures (32.4 %), POD was used as a coil constrainer to secure the coil construct. In 6 procedures (16.2 %), additional embolic devices were used to achieve vessel occlusion after initial POD deployment. After a mean follow-up of 3.2 months, no POD migration was observed but two complications occurred (5.4 %): one post embolic syndrome and one extensive infarction with splenic abscess.ConclusionThe POD system allows safe and effective proximal embolization of medium-sized vessels in a variety of clinical settings.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

MVP™ Micro Vascular Plug Systems for the Treatment of Pulmonary Arteriovenous Malformations

Purpose: To describe our institutional experience with MVP™ micro vascular plug systems for the treatment of pulmonary arteriovenous malformations (PAVMs). Materials and Methods: We performed a retrospective medical record review of 52 patients with 119 PAVMs treated exclusively with MVP™ systems (69 procedures/153 MVP™ systems) between July 2014 and July 2018. All patients had PAVMs with feeding artery diameters ≥ 2 mm. MVP™ systems were deployed according to physician preference. We collected patient demographic information; procedural data (including size of feeding artery, size and number of embolics used per PAVM, fluoroscopy time, contrast administration), technical success rates, complications, and persistence. Persistence was assessed using computed tomography angiography (CTA) performed 1–3 months and 3–5 years after embolization per clinical protocol. Results: All procedures were technically successful without major complications. Mean feeding artery diameter was 3.3 ± 1.2 mm. Mean fluoroscopy time per procedure and contrast volume administered per procedure were 35 ± 16 min and 217 ± 101 mL, respectively. A mean of 1.3 ± 0.8 MVP™ systems was used per PAVM. There were no instances of persistence during a mean follow-up time of 328 ± 258 days (range 26 to 914 days). Conclusions: For PAVMs with feeding artery diameters of 2 to 7.9 mm (mean 3.3 ± 1.2 mm), MVP™ systems are safe and effective given their high technical success rates and lack of persistence. Further prospective work will be required to elucidate the advantages and disadvantages of these MVP™ systems for PAVM embolization. Level of Evidence: Level III.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Endovascular Embolization of Post-tonsillectomy Pseudoaneurysm: A Single-Center Case Series

Objective: The aim of this study was to evaluate the efficacy and safety of endovascular embolization of post-tonsillectomy pseudoaneurysm with the usage of monomeric n-butyl-2-cyanoacrylate (NBCA) glue as a first intention. Methods: We retrospectively analyzed the technical details and clinical outcome of ten consecutive children presented with delayed post-tonsillectomy bleeding, caused by lingual or facial artery pseudoaneurysm, which was treated by endovascular embolization. Results: Seven patients had lingual artery pseudoaneurysm, and three patients had injury of a common linguo-facial trunk. Eight patients were treated by endovascular embolization using NBCA glue, and two patients had to be embolized using microcoils. All patients were successfully embolized with no clinical complications. One patient suffered from bleeding during the interventional procedure that was controlled by NBCA which infiltrated normal branches with no clinical sequelae. Conclusion: NBCA glue can be used as an effective appropriate embolizing material in endovascular embolization of post-tonsillectomy pseudoaneurysm. However, certain precautions are mandatory to avoid distal infiltration of normal arteries or proximal reflux that may endanger the internal carotid artery. Level of Evidence: Level 4, case series.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Image Fusion Guidance for In Situ Laser Fenestration of Aortic Stent graft for Endovascular Repair of Complex Aortic Aneurysm: Feasibility, Efficacy and Overall Functional Success

Objective: To evaluate feasibility, efficacy and overall functional success of image fusion guidance during laser-assisted in situ fenestration of aortic stent graft (LISFAS) for endovascular repair of complex aortic aneurysm (complex-EVAR) in a prospective study. Methods: Between September 2016 and July 2018, 20 patients were included and treated with LISFAS for complex-EVAR. Aortic aneurysms were either para-renal (n = 15) or thoraco-abdominal (n = 5) with 57 mm [first quartile: 54; third quartile: 68] median aneurysm diameter in 69 years [68;78] patients. All interventions were performed using the same angiographic system and 3D image fusion software for overlying pre-intervention CTA on per-intervention 2D fluoroscopy with cone-beam CT images to display target vessels ostia. Results: LISFAS for complex-EVAR with image fusion was performed in all patients, and no endovascular intervention required conversion to an open aortic repair. LISFAS of all target vessels was feasible in 18 patients (90%); 48 fenestrations out of 50 were performed successfully. Two fenestrations failed for renal arteries in two patients. Median ischemic times were as follows: 34 min [25;43] for superior mesenteric artery; 69 min [56;83] for left renal artery; 73 min [36;102] for right renal artery; and 93 min [89;96] for the celiac trunk. Median intervention and fluoroscopy times, iodinated contrast volume and X-ray exposure were 180 min [150;180], 74 min [64;87], 80 mL [59;113] and 338 Gy.cm{sup 2} [259;495], respectively. Efficacy was found in 17 patients (85%) on one-week follow-up CTA: Two patients had type 1 and 3 endoleaks, respectively, that were successfully embolized. Overall functional success was 90%. Median hospitalization stay was 9 days [8, 17]. The 30-day safety analysis was 90% (n = 2 deaths) owing to an undetermined cause and to bowel ischemia after low flow in intensive care unit. Conclusions: LISFAS using image fusion was feasible, efficient and overall functionally successful for complex-EVAR in this preliminary study.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Toward Transpulmonary Chemoembolization with Degradable Starch Microspheres: Systematic Analysis of Local and Systemic Effects in a Porcine Model

Purpose: To investigate local and systemic effects of transpulmonary chemoembolization (TPCE) with degradable starch microspheres (DSM) and doxorubicin. The long-term goal is to establish DSM-TPCE as a treatment option for pulmonary malignancies. Materials and Methods: Nine pigs underwent TPCE of either the right or left lower lobe pulmonary artery (LLPA) and bland embolization (TPE) of the contralateral LLPA. Before the procedures, macroaggregated albumin (MAA) particles were injected into both LLPAs, to exclude systemic shunting. Pulmonary arterial pressure, heart rate and oxygenation were recorded immediately before and at 1, 3, 5 and 10 min after treatment. To investigate possible nontarget embolization, animals underwent cerebral MRI (cMRI). We killed the animals after a contrast-enhanced chest computed tomography (CT) and performed a pathologic examination at 12 h (3), 24 h (3) and 72 h (3) after treatment. Results: All experiments were technically successful. Mean injected DSM dose until stasis was similar in TPCE and TPE (4.3 ± 1.4 vs. 4.0 ± 1.4 mL). Pulmonary arterial pressure increased significantly 3 min after treatment (TPE: 17 ± 5 vs. 27 ± 7 mmHg; TPCE: 22 ± 6 vs. 36 ± 8 mmHg). No significant changes in heart rate or peripheral oxygenation levels occurred. We observed no evidence of structural lung damage or permanent perfusion disruption on CT. MAA test injection and cMRI revealed no shunting or nontarget embolization. The pathologic assessment revealed nonspecific local inflammation of the lung parenchyma. Conclusion: In this large-animal model, TPCE and TPE appear feasible and safe. We observed a mild increase in pulmonary arterial pressure. Nontarget embolization did not occur. TPCE, as well as TPE, did not cause structural damage to the normal lung parenchyma.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Disruption of TGF-β signaling in smooth muscle cell prevents flow-induced vascular remodeling

Highlights: • TGF-β signaling in SMC contributes to the flow-induced vascular remodeling. • Disruption of TGF-β signaling in SMC can prevent this process. • Targeting SM-specific Tgfbr2 could be a novel therapeutic strategy for vascular remodeling. - Abstract: Transforming growth factor-β (TGF-β) signaling has been prominently implicated in the pathogenesis of vascular remodeling, especially the initiation and progression of flow-induced vascular remodeling. Smooth muscle cells (SMCs) are the principal resident cells in arterial wall and are critical for arterial remodeling. However, the role of TGF-β signaling in SMC for flow-induced vascular remodeling remains unknown. Therefore, the goal of our study was to determine the effect of TGF-β pathway in SMC for vascular remodeling, by using a genetical smooth muscle-specific (SM-specific) TGF-β type II receptor (Tgfbr2) deletion mice model. Mice deficient in the expression of Tgfbr2 (MyhCre.Tgfbr2{sup f/f}) and their corresponding wild-type background mice (MyhCre.Tgfbr2{sup WT/WT}) underwent partial ligation of left common carotid artery for 1, 2, or 4 weeks. Then the carotid arteries were harvested and indicated that the disruption of Tgfbr2 in SMC provided prominent inhibition of vascular remodeling. And the thickening of carotid media, proliferation of SMC, infiltration of macrophage, and expression of matrix metalloproteinase (MMP) were all significantly attenuated in Tgfbr2 disruption mice. Our study demonstrated, for the first time, that the TGF-β signaling in SMC plays an essential role in flow-induced vascular remodeling and disruption can prevent this process.

60 APPLIED LIFE SCIENCES↗

The inhibition of the effect and mechanism of vascular intimal hyperplasia in Tiam1 knockout mice

Highlights: • Tiam1 was highly expressed in the neointimal layer of the ligated carotid artery. • The intimal hyperplasia in Tiam1 KO mice after the ligation decreased. • PDGF-induced proliferation of HASMCs were inhibited with Tiam1 knockdown. • Rac1 involved in the migration of HASMCs that Tiam1 promoted. T-Cell Lymphoma Invasion and Metastasis 1 (Tiam1) is a specific nucleotide exchange factor (GEF) that can activate Rho-like GTPase and Rac1 and regulate various cellular processes, including cell cycle progression and cell migration. The roles of Tiam1 in vascular intimal hyperplasia, especially in vascular smooth muscle cell proliferation and migration, are not fully understood. In this study, we investigated the effect of Tiam1 on vascular intimal hyperplasia in a carotid artery ligation model and human aortic smooth muscle cells (HASMCs). We found that the expression of Tiam1 was up-regulated in the neointima of carotid artery ligation mice and that Tiam1{sup −/−} mice following carotid artery ligation had less neointimal formation compared with wild type mice. Knockdown of Tiam1 by siRNA markedly attenuated PDGF-induced migration and proliferation in HASMCs by inhibiting the activation of Rac1. Therefore, these results suggest that Tiam1 is an important regulator of intima hyperplasia. It may regulate vascular intimal hyperplasia through the activation of Rac1.

60 APPLIED LIFE SCIENCES↗

TU-F-12A-06: BEST IN PHYSICS (IMAGING) - A Novel Catheter-Based Radionuclide Imaging System to Characterize Atherosclerotic Plaque

Purpose: Atherosclerosis underlies coronary artery diseases, the leading cause of death in the United States and worldwide. In this study, we developed a novel catheter-based radionuclide imaging (CRI) system to image 18F-fluorodeoxyglucose (18F-FDG), a radionuclide, a marker of vascular inflammation, in murine carotid arteries and characterized the system for spatial resolution from multiple scintillating materials. Methods: The catheter system includes 35 mm and 8 mm fixed focal length lenses, which are subsequently connected to a CMOS camera and fiber holder. The distal ferrule of an image bundle is terminated with a wide-angle lens. The novelty of this system is a scintillating balloon with a crystal tip in the front of the wide angle lens to image light from the decay of 18F-FDG emission signal. The scintillating balloon is fabricated from 1mL of silicone RTV catalyst mixed with 1 mL base and 50 mg/mL calcium fluoride doped with Europium (CaF2:Eu). To identify the optimal scintillating materials with respect to resolution, we calculated modulation transfer function (MTF) of Yttrium Aluminum Garnet doped with Cerium (YAG:Ce), anthracene, and CaF2:Eu phosphors using a thin line optical phantom (Fig. 1a-1b). Macrophage-rich FVB murine atherosclerotic carotid plaque model (n = 4) was used in ex vivo experiments. Confirmatory imaging was also performed by an external optical imaging system (IVIS-200). Results: Analysis of the different phosphors (Fig 1b) showed that CaF2:Eu enabled the best resolution of 1.2μm. The CRI system visualized 18F-FDG in atherosclerotic plaques (Fig. 1d). The ligated left carotid (LR) artery exhibited 4× higher 18F-FDG signal intensity compared to the non-ligated right carotid (negative control) artery (1.65×10{sup 2} ±4.07×10{sup 1} vs. 4.44×10{sup 1}±2.17×10{sup 0}, A.U., p = 0.005) and confirmed with IVIS-200 (Fig. 1d). Conclusion: This CRI system enables high-resolution and sensitive detection of 18F-FDG uptake by murine atherosclerotic plaques.

60 APPLIED LIFE SCIENCES↗

<general dynamics of physical-chemical systems in mammals< fourth quarterly progress report, may 21 - aug. 20, 1965

Work is continuing on the mathematical modelling of the hydrodynamics of the arterial system. Discussion with Dr. McDonald has raised some questions relative to the geometric model of the arterial system. This area is considered important to provide a suitable base for consideration of the actual events taking place in the arteries. Attempts are being made to develop a model which will describe the geometry in terms of diameters against length, changes in cross-sectional area with division, and number of levels of arteries according to diameter. This work will be described in some detail in a technical report which is being prepared and will be submitted during the next quarter.

ARTERY↗

Accuracy of Centerline of Flow Measurement for Sizing of the Zenith AAA Endovascular Graft and Predictive Factor for Risk of Inadequate Sizing

The purpose of this study was to evaluate the accuracy of centerline of flow (CLF) measurement for precise sizing of the Zenith AAA endovascular graft (Zenith) and to identify predictive factors of risk of inadequate endograft sizing. We analyzed 42 consecutive patients treated using the Zenith with pre- and postoperative multidetector CT between 2001 and 2007. Endograft sizing was retrospectively performed using CLF on a three-dimensional workstation. The following parameters were investigated: (a) change in distance from lowest renal artery to hypogastric artery between CLF on preoperative CT (CLFp) and CLF of graft path on postoperative CT (CLFg); (b) supposed success rate of adequate endograft length selection; and (c) predictive factors for significant alteration (>10 mm) between CLFp and CLFg. Median change in distance from lowest renal artery to hypogastric artery was 4 mm. CLFg was >10 mm shorter than CLFp in 10 of 84 limbs (12%). Multivariate analysis demonstrated tortuosity index (TI) of infrarenal abdominal aorta (p = 0.019), aneurysm diameter (p = 0.035), and ipsilateral side of the main body insertion (p = 0.042) as predictive factors of significant alteration between CLFp and CLFg. Adequate endograft length selection was achieved in 39 of 42 cases (93%). All three inadequate endograft length selections were associated with tortuous aorta (TI > 20 mm). In conclusion, distance calculations based on CLF measurement provided accurate length selection of the Zenith in the majority of cases. TI, aneurysm diameter, and ipsilateral side were predictive factors for significant alteration. The CLF and aortic measurements including the TI may allow for improved sizing for Zenith placements.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Safety and Efficacy Assessment of Flow Redistribution by Occlusion of Intrahepatic Vessels Prior to Radioembolization in the Treatment of Liver Tumors

We evaluated the feasibility, safety, and efficacy of radioembolization (administered from one or two vascular points) after the redistribution of arterial blood flow in the liver in patients with hepatic neoplasms and arterial anatomic peculiarities (AAP). Twenty-four patients with liver neoplasms and AAP (graded according to Michel's classification) were included in the study. During pretreatment angiographic planning, all extrahepatic vessels that could feed the tumor were embolized and the intrahepatic vessels occluded in order to redistribute blood flow. The distribution of microspheres was initially assessed by using technetium-99m-labeled macroaggregated albumin ({sup 99m}Tc-MAA) from one of two vascular points before the administration of yttrium-90 ({sup 90}Y)-radiolabeled resin microspheres. Perfusion of lesions situated in the redistributed segments (L-RS) and nonredistributed segments (L-NRS) were compared by assessing the distribution of {sup 99m}Tc-MAA by SPECT/CT. Perfusion was graded as normal, reduced, or absent. {sup 90}Y resin microspheres were then injected from the same arterial sites as {sup 99m}Tc-MAA and the tumor response recorded 3 months later. The tumor response in L-RS was compared with that in L-NRS and graded as better, similar, or worse. Among 11 patients with type I AAP in whom mainly vessels in segments I-III or IV were occluded, perfusion of L-RS was graded as similar (n = 7) or reduced (n = 4). Among the remaining 13 patients with AAP types III (n = 3), V (n = 4), VIII (n = 3), and others (n = 3) in which aberrant arteries were occluded, perfusion of L-RS was graded as similar (n = 9), reduced (n = 3), or absent (n = 1). Overall, {sup 99m}Tc-MAA was present in the L-RS of 95.8% patients and the distribution of {sup 99m}Tc-MAA in L-RS and L-NRS were graded as similar in 66.6% of patients. Compared with lesions in the L-NRS, tumor response in L-RS was similar in 23 cases and worse in 1 case. No complications were recorded after the administration of {sup 90}Y resin microspheres. Redistribution of flow in L-RS is feasible and enables a safe and effective delivery of {sup 90}Y resin microspheres that are able to be distributed via intrahepatic collaterals and access the microvasculature of L-RS.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

The Preclose Technique in Percutaneous Endovascular Aortic Repair: A Systematic Literature Review and Meta-analysis

Purpose. To establish the efficacy and safety of the preclose technique in total percutaneous endovascular aortic repair (PEVAR).MethodsA systematic literature search of Medline database was conducted for series on PEVAR published between January 1999 and January 2012.ResultsThirty-six articles comprising 2,257 patients and 3,606 arterial accesses were included. Anatomical criteria used to exclude patients from undergoing PEVAR were not uniform across all series. The technical success rate was 94 % per arterial access. Failure was unilateral in the majority (93 %) of the 133 failed PEVAR cases. The groin complication rate in PEVAR was 3.6 %; a minority (1.6 %) of these groin complications required open surgery. The groin complication rate in failed PEVAR cases converted to groin cutdown was 6.1 %. A significantly higher technical success rate was achieved when arterial access was performed via ultrasound guidance. Technical failure rate was significantly higher with larger sheath size ({>=}20F). Conclusion. The preclose technique in PEVAR has a high technical success rate and a low groin complication rate. Technical success tends to increase with ultrasound-guided arterial access and decrease with larger access. When failure occurs, it is unilateral in the majority of cases, and conversion to surgical cutdown does not appear to increase the operative risk.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Post-Treatment Hemodynamics of a Basilar Aneurysm and Bifurcation

Aneurysm re-growth and rupture can sometimes unexpectedly occur following treatment procedures that were initially considered to be successful at the time of treatment and post-operative angiography. In some cases, this can be attributed to surgical clip slippage or endovascular coil compaction. However, there are other cases in which the treatment devices function properly. In these instances, the subsequent complications are due to other factors, perhaps one of which is the post-treatment hemodynamic stress. To investigate whether or not a treatment procedure can subject the parent artery to harmful hemodynamic stresses, computational fluid dynamics simulations are performed on a patient-specific basilar aneurysm and bifurcation before and after a virtual endovascular treatment. The simulations demonstrate that the treatment procedure produces a substantial increase in the wall shear stress. Analysis of the post-treatment flow field indicates that the increase in wall shear stress is due to the impingement of the basilar artery flow upon the aneurysm filling material and to the close proximity of a vortex tube to the artery wall. Calculation of the time-averaged wall shear stress shows that there is a region of the artery exposed to a level of wall shear stress that can cause severe damage to endothelial cells. The results of this study demonstrate that it is possible for a treatment procedure, which successfully excludes the aneurysm from the vascular system and leaves no aneurysm neck remnant, to elevate the hemodynamic stresses to levels that are injurious to the immediately adjacent vessel wall.

42 ENGINEERING↗

Targeted activation of endothelin-1 exacerbates hypoxia-induced pulmonary hypertension

Pulmonary arterial hypertension (PAH) is a fatal disease that eventually results in right heart failure and death. Current pharmacologic therapies for PAH are limited, and there are no drugs that could completely cure PAH. Enhanced activity of endothelin system has been implicated in PAH severity and endothelin receptor antagonists have been used clinically to treat PAH. However, there is limited experimental evidence on the direct role of enhanced endothelin system activity in PAH. Here, we investigated the correlation between endothelin-1 (ET-1) and PAH using ET-1 transgenic (ETTG) mice. Exposure to chronic hypoxia increased right ventricular pressure and pulmonary arterial wall thickness in ETTG mice compared to those in wild type mice. Of note, ETTG mice exhibited modest but significant increase in right ventricular pressure and vessel wall thickness relative to wild type mice even under normoxic conditions. To induce severe PAH, we administered SU5416, a vascular endothelial growth factor receptor inhibitor, combined with exposure to chronic hypoxia. Treatment with SU5416 modestly aggravated hypoxia-induced pulmonary hypertension, right ventricular hypertrophy, and pulmonary arterial vessel wall thickening in ETTG mice in association with increased interleukin-6 expression in blood vessels. However, there was no sign of obliterative endothelial cell proliferation and plexiform lesion formation in the lungs. These results demonstrated that enhanced endothelin system activity could be a causative factor in the development of PAH and provided rationale for the inhibition of endothelin system to treat PAH. - Highlights: • Role of endothelin-1 in pulmonary arterial hypertension (PAH) was investigated. • The endothelin-1 transgenic (ETTG) and wild type (WT) mice were analyzed. • ETTG mice spontaneously developed PAH under normoxia conditions. • SU5416 further aggravated PAH in ETTG mice. • Enhanced endothelin system activity could be a causative factor in PAH development.

60 APPLIED LIFE SCIENCES↗

Estimating Cardiac Exposure From Breast Cancer Radiotherapy in Clinical Practice

Purpose: To assess the value of maximum heart distance (MHD) in predicting the dose and biologically effective dose (BED) to the heart and the left anterior descending (LAD) coronary artery for left-tangential breast or chest wall irradiation. Methods and Materials: A total of 50 consecutive breast cancer patients given adjuvant left-tangential irradiation at a large U.K. radiotherapy center during 2006 were selected. For each patient, the following were derived using three-dimensional computed tomography (CT) planning: (1) mean dose and BED to the heart, (2) mean dose and BED to the LAD coronary artery, (3) MHD, (4) position of the CT slice showing the maximum area of the irradiated heart relative to the mid-plane slice, and (5) sternal and contralateral breast thickness (measures of body fat). Results: A strong linear correlation was found between the MHD and the mean heart dose. For every 1-cm increase in MHD, the mean heart dose increased by 2.9% on average (95% confidence interval 2.5-3.3). A strong linear-quadratic relationship was seen between the MHD and the mean heart BED. The mean LAD coronary artery dose and BED were also correlated with the MHD but the associations were weaker. These relationships were not affected by body fat. The mid-plane CT slice did not give a reliable assessment of cardiac irradiation. Conclusion: The MHD is a reliable predictor of the mean heart dose and BED and gives an approximate estimate of the mean LAD coronary artery dose and BED. Doses predicted by the MHD could help assess the risk of radiation-induced cardiac toxicity where individual CT-based cardiac dosimetry is not possible.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Impact of Intrafractional Bowel Gas Movement on Carbon Ion Beam Dose Distribution in Pancreatic Radiotherapy

Purpose: To assess carbon ion beam dose variation due to bowel gas movement in pancreatic radiotherapy. Methods and Materials: Ten pancreatic cancer inpatients were subject to diagnostic contrast-enhanced dynamic helical CT examination under breath-holding conditions, which included multiple-phase dynamic CT with arterial, venous, and delayed phases. The arterial-venous phase and arterial-delayed phase intervals were 35 and 145 s, respectively. A compensating bolus was designed to cover the target obtained at the arterial phase. Carbon ion dose distribution was calculated by applying the bolus to the CT data sets at the other two phases. Results: Dose conformation to the clinical target volume was degraded by beam overshoot/undershoot due to bowel gas movement. The D95 for clinical target volume was degraded from 98.2% (range, 98.0-99.1%) of the prescribed dose to 94.7% (range, 88.0-99.0%) at 145 s. Excessive dosing to normal tissues varied among tissues and was, for example, 12.2 GyE/13.1 GyE (0 s/145 s) for the cord and 38.8 GyE/39.8 GyE (0 s/145 s) for the duodenum. The magnitude of beam overshoot/undershoot was particularly exacerbated from the anterior and left directions. Conclusions: Bowel gas movement causes dosimetric variation to the target during treatment for radiotherapy. The effect of bowel gas movement varies with beam angle, with greatest influence on the anterior-posterior and left-right beams.

62 RADIOLOGY AND NUCLEAR MEDICINE↗