At least 1,135 records · Page 63

Sound absorption of low-temperature reusable surface insulation candidate materials

Sound absorption data from tests of four candidate low-temperature reusable surface insulation materials are presented. Limitations on the use of the data are discussed, conclusions concerning the effective absorption of the materials are drawn, and the relative significance to Vibration and Acoustic Test Facility test planning of the absorption of each material is assessed.

Johnston, J. D.↗

Fitting Leak Test Report

Many Human Landing System flight elements are anticipated to implement mechanically connected joints in cryogenic fluid lines to simplify system assembly. These joints will need to survive launch vibration, while cold, and remain as leak‐free as possible to minimize commodity loss. Threaded fluid fittings should be qualified for use in their expected environments to reduce risk and ensure mission success. A new ground‐based test apparatus was developed and validated to obtain quantifiable low leak rate test data for a small component, such as a pressurized threaded fluid fitting, while in the temperature range of liquid hydrogen. A cryocooler is used to attain the cold test temperature and helium leakage from a pressurized fitting mounted within a vacuum test chamber is measured using a mass spectrometer leak detector. Two different sizes of Swagelok VCR fittings with three different types of seal rings were selected as the test articles for the initial proof of concept testing. Each fitting configuration was subjected to two consecutive cryogenic thermal cycles and cold leak measurement tests, followed by exposure to a high vibration test profile at ambient temperature on a shaker table, and then two additional cold leak measurement tests. Very low leak rates, below the acceptable leak rate threshold, were measured at the pressures tested. Several enhancements to the test hardware are discussed that would facilitate a comprehensive fitting qualification test campaign by enabling a higher test throughput rate and ensuring a repeatable test profile.

Cryogenic Fluid Management↗

Experimental Analysis of Mast Lifting and Bending Forces on Vibration Patterns Before and After Pinion Reinstallation in an OH-58 Transmission Test Rig

As part of a collaborative research program between NASA Ames Research Center (ARC), NASA Glenn Research Center (GRC), and the US Army Laboratory, a series of experiments is being performed in GRC's 500 HP OH-58 Transmission Test Rig facility and ARC's AH-I Cobra and OH-58c helicopters. The findings reported in this paper were drawn from Phase-I of a two-phase test-rig experiment, and are focused on the vibration response of an undamaged pinion gear operating in the transmission test rig. To simulate actual flight conditions, the transmission system was run at three torque levels, as well as two mast lifting and two mast bending levels. The test rig was also subjected to disassembly and reassembly of the main pinion housing to simulate the effect of maintenance operations. An analysis of variance based on the total power of the spectral distribution indicates the relative effect of each experimental factor, including Wong interactions with torque. Reinstallation of the main pinion assembly is shown to introduce changes in the vibration signature, suggesting the possibility of a strong effect of maintenance on HUMS design and use. Based on these results, further research will be conducted to compare these vibration responses with actual OH58c helicopter transmission vibration patterns.

Huff, Edward M.↗

Facility for interferometric testing of 1.25-m mirrors at liquid helium temperatures

A concept is presented for a national cryogenic optics test facility capable of optical characterization of 1.25 m diameter optics having focal lengths up to 6.2 m at temperatures from 300 K to near 4 K. The facility will be comprised of a large Dewar with a phase shift interferometer, a two stage vacuum system employing a turbomolecular pump, and an integral vibration isolation system. The entire facility will be housed in a concrete site with a massive floor to assist in reducing vibration during optical tests. By providing interchangeable sections, the overall height of the Dewar can be adjusted to provide for testing of shorter focal length optics. The background for the facility is discussed along with the facility location, and the requirements and the performance considerations which drive the Dewar design with respect to the vibration isolation system, vacuum system, and optical interferometry.

Salerno, Louis J.↗

Facility for interferometric testing of 1.25-m mirrors at liquid helium temperatures

A concept is presented for a national cryogenic optics test facility capable of optical characterization of 1.25 m diameter optics having focal lengths up to 6.2 m at temperatures from 300 K to near 4 K. The facility will be comprised of a large Dewar with a phase shift interferometer, a two-stage vacuum system employing a turbomolecular pump, and an integral vibration isolation system. The entire facility will be housed in a concrete site with a massive floor to assist in reducing vibration during optical tests. By providing interchangeable sections, the overall height of the Dewar can be adjusted to provide for testing of shorter focal length optics. The background for the facility is discussed along with the facility location, and the requirements and the performance considerations which drive the Dewar design with respect to the vibration isolation system, vacuum system, and optical interferometry.

Salerno, Louis J.↗

The Structural Heat Intercept-Insulation-Vibration Evaluation Rig (SHIVER)

NASA is currently investigating methods to reduce the boil-off rate on large cryogenic upper stages. Two such methods to reduce the total heat load on existing upper stages are vapor cooling of the cryogenic tank support structure and integration of thick multilayer insulation systems to the upper stage of a launch vehicle. Previous efforts have flown a 2-layer MLI blanket and shown an improved thermal performance, and other efforts have ground-tested blankets up to 70 layers thick on tanks with diameters between 2 3 meters. However, thick multilayer insulation installation and testing in both thermal and structural modes has not been completed on a large scale tank. Similarly, multiple vapor cooled shields are common place on science payload helium dewars; however, minimal effort has gone into intercepting heat on large structural surfaces associated with rocket stages. A majority of the vapor cooling effort focuses on metallic cylinders called skirts, which are the most common structural components for launch vehicles. In order to provide test data for comparison with analytical models, a representative test tank is currently being designed to include skirt structural systems with integral vapor cooling. The tank is 4 m in diameter and 6.8 m tall to contain 5000 kg of liquid hydrogen. A multilayer insulation system will be designed to insulate the tank and structure while being installed in a representative manner that can be extended to tanks up to 10 meters in diameter. In order to prove that the insulation system and vapor cooling attachment methods are structurally sound, acoustic testing will also be performed on the system. The test tank with insulation and vapor cooled shield installed will be tested thermally in the B2 test facility at NASAs Plumbrook Station both before and after being vibration tested at Plumbrooks Space Power Facility.

Cryogenic Fluid Management↗

Thematic mapper flight model preshipment review data package. Volume 3, part B: System data

Procedures and results are presented for performance and systems integration tests of flight model-1 thematic mapper. Aspects considered cover electronic module integration, radiometric calibration, spectral matching, spatial coverage, radiometric calibration of the calibrator, coherent noise, dynamic square wave response, band to band registration, geometric accuracy, and self induced vibration. Thermal vacuum tests, EMI/EMS, and mass properties are included. Liens are summarized.

Source record↗

A Multifunctional Bistable Ultrathin Composite Boom for In-Space Monitoring of Deployment Dynamics

A novel concept of a multifunctional deployable ultrathin composite boom with flexible electronics and circuits integrated in a highly compact configuration, which can monitor its deployment dynamics in space, is presented in this paper. This concept is particularly suitable for CubeSats with extremely limited payload volume. The multifunctional deployable boom will be flight hardware installed in a 3U CubeSat that is scheduled to be launched to the International Space Station (ISS) in 2023 as an in-space technology demonstration. The multifunctional boom consists of a bistable self-deployable ultrathin composite boom, flexible electronics and circuitry for dynamics monitoring, and embedded flexible thin wires for power delivery and data transmission. The design, materials, and fabrication methods for the multifunctional boom are presented. Tests in simulated space environments showed the survivability and stability of the flexible electronics within a temperature range of 7 °C to 50 °C and under a high vacuum level of approximately 1 × 10−6 Torr. Ground-based vibration and deployment tests demonstrated the overall design of the multifunctional boom, data acquisition system, and deployment mechanism. Analyses of the data obtained from the integrated flexible electronics successfully captured the deployment dynamics and identified the natural frequencies of the boom in the range of 0–100 Hz. These results demonstrate that the concept is a promising approach to future multifunctional ultrathin deployable space structures.

Yao Yao↗

A Multifunctional Bistable Ultrathin Composite Boom for In-Space Monitoring of Deployment Dynamics

A novel concept of a multifunctional deployable ultrathin composite boom with flexible electronics and circuits integrated in a highly compact configuration, which can monitor its deployment dynamics in space, is presented in this paper. This concept is particularly suitable for CubeSats with extremely limited payload volume. The multifunctional deployable boom will be flight hardware installed in a 3U CubeSat that is scheduled to be launched to the International Space Station (ISS) in 2023 as an in-space technology demonstration. The multifunctional boom consists of a bistable self-deployable ultrathin composite boom, flexible electronics and circuitry for dynamics monitoring, and embedded flexible thin wires for power delivery and data transmission. The design, materials, and fabrication methods for the multifunctional boom are presented. Tests in simulated space environments showed the survivability and stability of the flexible electronics within a temperature range of 7 °C to 50 °C and under a high vacuum level of approximately 1 × 10−6 Torr. Ground-based vibration and deployment tests demonstrated the overall design of the multifunctional boom, data acquisition system, and deployment mechanism. Analyses of the data obtained from the integrated flexible electronics successfully captured the deployment dynamics and identified the natural frequencies of the boom in the range of 0–100 Hz. These results demonstrate that the concept is a promising approach to future multifunctional ultrathin deployable space structures.

Yao Yao↗

Experiments In Characterizing Vibrations Of A Structure

Report discusses experiments conducted to test methods of identification of vibrational and coupled rotational/vibrational modes of flexible structure. Report one in series that chronicle development of integrated system of methods, sensors, actuators, analog and digital signal-processing equipment, and algorithms to suppress vibrations in large, flexible structure even when dynamics of structure partly unknown and/or changing. Two prior articles describing aspects of research, "Autonomous Frequency-Domain Indentification" (NPO-18099), and "Automated Characterization Of Vibrations Of A Structure" (NPO-18141).

Yam, Yeung↗

Test Rack Development for Extended Operation of Advanced Stirling Convertors at NASA Glenn Research Center

The U.S. Department of Energy (DOE), Lockheed Martin Space Company (LMSC), Sun power Inc., and NASA Glenn Research Center (GRC) have been developing an Advanced Stirling Radioisotope Generator (ASRG) for use as a power system on space science missions. This generator will make use of free-piston Stirling convertors to achieve higher conversion efficiency than currently available alternatives. NASA GRC's support of ASRG development includes extended operation testing of Advanced Stirling Convertors (ASCs) developed by Sunpower Inc. In the past year, NASA GRC has been building a test facility to support extended operation of a pair of engineering level ASCs. Operation of the convertors in the test facility provides convertor performance data over an extended period of time. Mechanical support hardware, data acquisition software, and an instrumentation rack were developed to prepare the pair of convertors for continuous extended operation. Short-term tests were performed to gather baseline performance data before extended operation was initiated. These tests included workmanship vibration, insulation thermal loss characterization, low-temperature checkout, and fUll-power operation. Hardware and software features are implemented to ensure reliability of support systems. This paper discusses the mechanical support hardware, instrumentation rack, data acquisition software, short-term tests, and safety features designed to support continuous unattended operation of a pair of ASCs.

Dugala, Gina M.↗

In-process, layer-by-layer non-destructive testing of additive manufactured components using linear and nonlinear vibrational resonance

Provided is an additive manufacturing system capable of performing in-process, layer-by-layer non-destructive testing, the additive manufacturing system including: a plate for producing a part thereon; a transducer attached to the plate and configured to induce vibrations in the part; and a laser vibrometer configured to detect a vibrational response of the part to determine whether defect and/or anisotropy exists within the part.

Remillieux, Marcel↗

Test and theory for piezoelectric actuator-active vibration control of rotating machinery

The application of piezoelectric actuators for active vibration control (AVC) of rotating machinery is examined. Theory is derived and the resulting predictions are shown to agree closely with results of tests performed on an air turbine driven-overhung rotor. The test results show significant reduction in unbalance, transient and sub-synchronous responses. Results from a 30-hour endurance test support the AVD system reliability. Various aspects of the electro-mechanical stability of the control system are also discussed and illustrated. Finally, application of the AVC system to an actual jet engine is discussed.

Palazzolo, A. B.↗

Acoustic sensor engineering evaluation test report

Two types of one-inch diameter sound pressure level sensors, which are candidates for monitoring ambient noise in the shuttle orbiter crew compartment during rest periods, were exposed to temperature, passive humidity, and vibration. One unexposed sensor of each type served as a reference unit. Except for the humidity exposures, each of the three capacitive microphones was individually tested in sequence with the essential voltage power supply and preamplifier. One unit exibited anomalous characteristics after the humidity exposure but returned to normal after being dried in an oven at 115 deg for two hours. Except for the humidity exposures, each of the three piezoelectric microphones was individually tested with a laboratory type amplifier. Two apparent failures occurred during these tests. The diaphragm on one was found ruptured after the fourth cycle of the humidity test. A second sensor showed an anomaly after the random vibration tests at which time its sensitivity was consistent at about one-half its former value.

Phillips, E. L., Jr.↗

A Summary of the NEXT-C Flight Thruster Proto-flight Testing

Aerojet Rocketdyne (AR), under contract to NASA Glenn Research Center, built, tested and delivered the first flight version of the NEXT-C (NASA Evolutionary Xenon Thruster – Commercial) engine system. This system is comprised of a 7 kW thruster and power processing unit which are the commercial variants of the NEXT prototype thruster and power processing unit. In addition to developing the NEXT-C engine system for potential future NASA science missions, AR is dedicated to ensuring that this propulsion system is viable for commercial users and a wider variety of commercial applications. This paper will focus on the performance of the first flight model thruster, SN001, and presents an overview of the proto-flight testing environments and data obtained. For this first flight thruster, the proto-flight test sequence involved characterizing the performance of the thruster, in addition to vibration and thermal vacuum testing of the thruster. Between each of these environmental tests, the performance of the thruster was verified, ensuring that the environmental exposures, i.e. vibration and TVAC, did not affect the thruster performance. Specifically, the proto-flight data obtained included discharge chamber, optics and neutralizer performance. Faraday probe and ExB data obtained in the regions downstream of the thruster are presented and used to calculate thrust, and therefore specific impulse and total efficiency. Lastly, data are presented showing how the centroid of the ion beam, assumed to be indicative of the thrust vector location, varies throughout the entire proto-flight test campaign. The proto-flight testing of the NEXT-C PPU is documented in a previously published paper by Bontempo4. Following the proto-flight testing of the thruster, the thruster and its PPU successfully completed a System Integrated Test (SIT) tailored to the DART Mission. After the completion of the proto-flight testing, the SN001 thruster and SN002 PPU were delivered to APL for use on the DART mission.

Ion thruster↗

Demonstration of Multilayer Insulation, Vapor Cooling of Structure, and Mass Gauging for Large Scale Upper Stages: Structural Heat Intercept, Insulation, and Vibration Evaluation Rig (SHIIVER) Final Report

Testing was completed on the Structural Heat Intercept, Insulation, and Vibration Evaluation Rig (SHIIVER) between August 2019 and January 2020. SHIIVER was designed to be a test bed for the scaling of cryogenic fluid management technologies as applied to large upper stages and long duration in-space stages. The hardware consists of a 4 meter diameter stainless steel tank, structural skirts supporting the tank in the aft direction, and an aluminum forward skirt with vapor cooling channels bolted to it. The initial testing of the SHIIVER hardware was with liquid hydrogen and liquid nitrogen (as a substitute fluid for liquid oxygen and liquid methane) and sought to demonstrate the use of boil-off vapor to intercept heat on a structural skirt, multilayer insulation (MLI) on the tank domes, and the radio frequency mass gauge (RFMG). Testing was completed in four stages: a baseline thermal vacuum test prior to installation of the MLI, a thermal vacuum test after the MLI installation, a reverberant acoustic test, and a subsequent thermal vacuum test to verify that no damage occurred during the reverberant acoustic testing. Each thermal vacuum test with chamber wall at ambient temperature and vacuum level in the 10-6 torr range was conducted continuously between approximately 90% full and 25% full. Test results showed that the vapor cooling reduced the heat load to the tank by approximately 10%, but the boil-off by less than 3% at 50% full with no MLI on the domes. It reduced the heat load to the tank by approximately 10%, but the boil-off was essentially unchanged at 50% full whether or not vapor cooling was operational with MLI on the domes. The MLI reduced the heat load to the tank by approximately 40% at all fill levels, but the boil-off by approximately 25% at 90% full and 45% below 65% full. The RFMG performed well over all fill ranges, and several RF tank modes were used to gauge the mass of fluid in the tank. SHIIVER was then exposed to an acoustic environment of 147 dB OASPL (overall sound pressure level) in a reverberant chamber. The acoustic environment and profile envelopes the upper stage internal acoustic level of several different modern launch vehicles. No structural or thermal performance changes were observed as a result of acoustic testing. Final thermal vacuum testing after the acoustic testing showed no degradation to the MLI due to the acoustic environment as measured via system heat loads.

SHIIVER↗