Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “vapor”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,135 records · Page 63

New explicit equations for the accurate calculation of the growth and evaporation of hydrometeors by the diffusion of water vapor

The traditional explicit growth equation has been widely used to calculate the growth and evaporation of hydrometeors by the diffusion of water vapor. This paper reexamines the assumptions underlying the traditional equation and shows that large errors (10-30 percent in some cases) result if it is used carelessly. More accurate explicit equations are derived by approximating the saturation vapor-density difference as a quadratic rather than a linear function of the temperature difference between the particle and ambient air. These new equations, which reduce the error to less than a few percent, merit inclusion in a broad range of atmospheric models.

Srivastava, R. C.↗

Asymmetric gravity jitter excited slosh waves at a liquid-vapor-solid interface in microgravity

The dynamical behavior of fluids affected by the asymmetric gravity jitter oscillations is investigated focusing on the surface tension effect on partially filled rotating fluids in a sub-scale gravity probe-B spacecraft propellant dewar tank. Data obtained revealed that the lower frequency gravity jitter imposed on the time-dependent variations of the background gravity direction induced a greater amplitude of oscillations and a stronger degree of asymmetry in liquid-vapor interface geometry than that caused by the higher frequency gravity jitter. It is also found that the greater the components of background gravity in radial and circumferential directions the greater the contribution to driving more toward increasing amplitude and degrees of asymmetry of the liquid-vapor interface profiles, which in turn modify the disturbance of moment of inertia and angular momentum of spacecraft.

Hung, R. J.↗

Applied Magnetic Field Enhances Arc Vapor Deposition

Applied magnetic field enhances performance of vaporization part of arc vapor deposition apparatus. When no magnetic field applied by external means, arc wonders semirandomly over cathode, with net motion toward electrical feedthrough. When magnetic field applied arc moves circumferentially around cathode, and downward motion suppressed.

Miller, T. A.↗

MMIC Receiver For Water-Vapor Radiometer

MMIC receiver puts out signal, frequency of which proportioned to brightness temperature of sky at input frequency of 31 GHz. Miniaturization enhances thermal stability and stability of calibration of water-vapor radiometer. Potential for mass production at relatively low cost. Facilitating widespread use of MMIC water vapor radiometers in meteorology and aviation, deployed at several global sites to improve capability of general circulation models and at airports to monitor icing conditions by measuring supercooled liquid water in clouds.

Sukamto, Lin M.↗

Vapor-Generator Wand Helps To Reveal Airflow Patterns

In vapor-generator wand, liquid propylene glycol flows into electrically heated stainless-steel tube. Liquid boils in heated tube, and emerging vapor forms dense, smoke-like fog used to make airflow patterns visible. Built in variety of sizes, suitable for uses ranging from tabletop demonstrations to research in wind tunnels. For best viewing, plume illuminated by bright, focused incandescent spotlight at right angle to viewing direction. Viewing further enhanced by coating walls of test chamber with flat, dark color to minimize reflections and increase contrast.

Robelen, David B.↗

A membrane-based subsystem for water-vapor recovery from plant-growth chambers

Bioregenerative systems--life-support systems to regenerate oxygen, food, and water--are the key to establishing man's permanent presence in space. NASA is investigating the use of plant-growth chambers (PGC's) for space missions and for bases on the moon and Mars. PGC's serve several important purposes, including the following: (1) oxygen and food production; (2) carbon-dioxide removal; and (3) water purification and reuse. The key to the successful development of PGC's is a system to recover and reuse the water vapor that is transpired by the leaves of the growing plants. In this program we propose to develop a simple, reliable, membrane-based system that allows the recovery, purification, and reuse of the transpired water vapor through control of temperature and humidity levels in the PGC. This system has characteristics that make it ideally suited to use in space: (1) minimal power requirements; (2) small volume and mass; (3) simplicity; (4) reliability; and (5) versatility. In Phase 1 we will do the following: (1) develop an accurate, predictive model of our temperature- and humidity-control system, based on parametric tests of membrane modules; and (2) use this model to design systems for selected PGC's. In Phase 2, we will seek to design, fabricate, test, and deliver a breadboard unit to NASA for testing on a PGC.

Ray, R. J.↗

Active Hydrazine Vapor Sampler (AHVS)

The Active Hydrazine Vapor Sampler (AHVS) was developed to detect vapors of hydrazine (HZ) and monomethylhydrazine (MMH) in air at parts-per-billion (ppb) concentration levels. The sampler consists of a commercial personal pump that draws ambient air through paper tape treated with vanillin (4-hydroxy-3-methoxybenzaldehyde). The paper tape is sandwiched in a thin cardboard housing inserted in one of the two specially designed holders to facilitate sampling. Contaminated air reacts with vanillin to develop a yellow color. The density of the color is proportional to the concentration of HZ or MMH. The AHVS can detect 10 ppb in less than 5 minutes. The sampler is easy to use, low cost, and intrinsically safe and contains no toxic material. It is most beneficial for use in locations with no laboratory capabilities for instrumentation calibration. This paper reviews the development, laboratory test, and field test of the device.

Young, Rebecca C.↗

Integration and use of Microgravity Research Facility: Lessons learned by the crystals by vapor transport experiment and Space Experiments Facility programs

The Crystals by Vapor Transport Experiment (CVTE) and Space Experiments Facility (SEF) are materials processing facilities designed and built for use on the Space Shuttle mid deck. The CVTE was built as a commercial facility owned by the Boeing Company. The SEF was built under contract to the UAH Center for Commercial Development of Space (CCDS). Both facilities include up to three furnaces capable of reaching 850 C minimum, stand-alone electronics and software, and independent cooling control. In addition, the CVTE includes a dedicated stowage locker for cameras, a laptop computer, and other ancillary equipment. Both systems are designed to fly in a Middeck Accommodations Rack (MAR), though the SEF is currently being integrated into a Spacehab rack. The CVTE hardware includes two transparent furnaces capable of achieving temperatures in the 850 to 870 C range. The transparent feature allows scientists/astronauts to directly observe and affect crystal growth both on the ground and in space. Cameras mounted to the rack provide photodocumentation of the crystal growth. The basic design of the furnace allows for modification to accommodate techniques other than vapor crystal growth. Early in the CVTE program, the decision was made to assign a principal scientist to develop the experiment plan, affect the hardware/software design, run the ground and flight research effort, and interface with the scientific community. The principal scientist is responsible to the program manager and is a critical member of the engineering development team. As a result of this decision, the hardware/experiment requirements were established in such a way as to balance the engineering and science demands on the equipment. Program schedules for hardware development, experiment definition and material selection, flight operations development and crew training, both ground support and astronauts, were all planned and carried out with the understanding that the success of the program science was as important as the hardware functionality. How the CVTE payload was designed and what it is capable of, the philosophy of including the scientists in design and operations decisions, and the lessons learned during the integration process are descussed.

Heizer, Barbara L.↗

A comparison between protein crystals grown with vapor diffusion methods in microgravity and protein crystals using a gel liquid-liquid diffusion ground-based method

Crystals of human serum albumin have been successfully grown in a variety of gels using crystallization conditions otherwise equivalent to those utilized in the popular hanging-drop vapor-equilibrium method. Preliminary comparisons of gel grown crystals with crystals grown by the vapor diffusion method via both ground-based and microgravity methods indicate that crystals superior in size and quality may be grown by limiting solutal convection. Preliminary X-ray diffraction statistics are presented.

Miller, Teresa Y.↗

A semi-empirical model for the complete orientation dependence of the growth rate for vapor phase epitaxy - Chloride VPE of GaAs

A semi-empirical model has been developed to determine the complete crystallographic orientation dependence of the growth rate for vapor phase epitaxy (VPE). Previous researchers have been able to determine this dependence for a limited range of orientations; however, our model yields relative growth rate information for any orientation. This model for diamond and zincblende structure materials is based on experimental growth rate data, gas phase diffusion, and surface reactions. Data for GaAs chloride VPE is used to illustrate the model. The resulting growth rate polar diagrams are used in conjunction with Wulff constructions to simulate epitaxial layer shapes as grown on patterned substrates. In general, this model can be applied to a variety of materials and vapor phase epitaxy systems.

Seidel-Salinas, L. K.↗

Fiber optic-based laser vapor screen flow visualization systems for aerodynamic research in larger-scale subsonic and transonic wind tunnels

The design, installation, and application of the NASA laser vapor screen (LVS) flow visualization systems developed by 10-foot high speed tunnel and 8-foot transonic pressure tunnel are discussed. Sufficient quantity of water is injected into the wind tunnel diffuser section to increase the relative humidity and promote condensation of the water vapor in the flow field about the model. Vortex-dominated flows are illuminated with an intense sheet of laser light. Fiber optics are used to deliver the laser beam through the plenum shell that surrounds the test section of each facility and to the light sheet-generating optics positioned in the ceiling window of the test section. Operational experience indicates that fiber optic-based systems are safe, reliable, and capable of proving high-quality off-surface flow visualization in larger scale subsonic and transonic wind tunnels.

Erickson, Gary E.↗

Water vapor column abundance retrievals during FIFE

A variation of the modified Langley plot algorithm is reported here and applied to the retrieval of atmospheric water column abundance from a filtered sunphotometer. In this new methodology an absorption data base (LOWTRAN 7) is used to compute a water abundance versus transmittance curve of growth, rather than the square-root dependence previously assumed. Validation of the technique is provided from an uncertainty analysis, and plans to further validate using Fourier transform spectrometers are detailed. The new sunphotometer technique is used to report local column water vapor during the First ISLSCP Field Experiment (FIFE), and comparisons are made with abundances retrieved via FIFE radiosonde observations. The sunphotometer data can best be utilized, however, to in turn validate data from airborne or in-orbit measurements of water vapor. With these flight sensors, horizontal and topographic variability within the scene can be viewed. An example of the airborne data set is given using an image from the airborne visible infrared imaging spectrometer, as acquired on August 31, 1990.

Bruegge, Carol J.↗

Single liquid source plasma-enhanced metalorganic chemical vapor deposition of high-quality YBa2Cu3O(7-x) thin films

High quality YBa2Cu3O(7-x) films were grown in-situ on LaAlO3 (100) by a novel single liquid source plasma-enhanced metalorganic chemical vapor deposition process. The metalorganic complexes M(thd) (sub n), (thd = 2,2,6,6-tetramethyl-3,5-heptanedionate; M = Y, Ba, Cu) were dissolved in an organic solution and injected into a vaporizer immediately upstream of the reactor inlet. The single liquid source technique dramatically simplifies current CVD processing and can significantly improve the process reproducibility. X-ray diffraction measurements indicated that single phase, highly c-axis oriented YBa2Cu3O(7-x) was formed in-situ at substrate temperature 680 C. The as-deposited films exhibited a mirror-like surface, had transition temperature T(sub cO) approximately equal to 89 K, Delta T(sub c) less than 1 K, and Jc (77 K) = 10(exp 6) A/sq cm.

Zhang, Jiming↗

Isomerization reaction dynamics and equilibrium at the liquid-vapor interface of water. A molecular-dynamics study

The gauche-trans isomerization reaction of 1,2-dichloroethane at the liquid-vapor interface of water is studied using molecular-dynamics computer simulations. The solvent bulk and surface effects on the torsional potential of mean force and on barrier recrossing dynamics are computed. The isomerization reaction involves a large change in the electric dipole moment, and as a result the trans/gauche ratio is considerably affected by the transition from the bulk solvent to the surface. Reactive flux correlation function calculations of the reaction rate reveal that deviation from the transition-state theory due to barrier recrossing is greater at the surface than in the bulk water. This suggests that the system exhibits non-Rice-Ramsperger-Kassel-Marcus behavior due to the weak solvent-solute coupling at the water liquid-vapor interface.

Benjamin, Ilan↗

Numerical Study of the Transient Vaporization of an Oxygen Droplet at Sub- and Super-Critical Conditions

Unsteady vaporization of a droplet in a high-pressure quiescent environment has been studied. With spherical symmetry and constant pressure, the process is diffusion controlled. At low pressures droplet heating is significant for most of the droplet lifetime, and an unsteady analysis of the gas phase is required. Then, the vaporization of a liquid oxygen droplet in gaseous hydrogen at moderate and high pressures is considered. At super-critical pressures, the surface temperature reaches the computed critical mixture value where a model for super-critical combustion is needed. The details of the diffusion layer of dissolved hydrogen do not significantly affect the results. Various methods are explored to compute the gas-phase density. Under the model's assumptions, homogeneous nucleation is not likely to occur.

Delplanque, J.-P.↗

Ground-based microwave remote sensing of water vapor in the mesosphere and stratosphere

A ground-based, portable microwave radiometer that will be used to measure water vapor in the 30-80-km altitude region, and is to operate 24 hr a day, is described. The thermally excited 22.235-GHz rotational-transition line of water vapor is employed. The emission from this region produces a signal with an apparent brightness temperature of the order 0.1 to 0.5 K. A steerable reflector is used to provide optimal viewing angles, depending on the geographic location and season. Periodic tipping curve scans by this reflector permit determination of the amount of tropospheric correction that is applied to the data. All local oscillators in the receiver are crystal-controlled so that narrow-band spectral analysis of the received line shape can be performed.

Croskey, Charles L.↗

Intercomparison of stratospheric water vapor observed by satellite experiments - Stratospheric Aerosol and Gas Experiment II versus Limb Infrared Monitor of the Stratosphere and Atmospheric Trace Molecule Spectroscopy

A comparison is made of the stratospheric water vapor measurements made by the satellite sensors of the Stratospheric Aerosol and Gas Experiment II (SAGE II), the Nimbus-7 LIMS, and the Spacelab 3 Atmospheric Trace Molecule Spectroscopy (ATMOS) experiment. It was found that, despite differences in the measurement techniques, sampling bias, and observational periods, the three experiments have disclosed a generally consistent pattern of stratospheric water vapor distribution. The only significant difference occurs at high southern altitudes in May below 18 km, where LIMS measurements were 2-3 ppmv greater than those of SAGE II and ATMOS.

Chiou, E. W.↗