Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “transmissive”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,135 records · Page 63

In situ transmission electron microscopy observations of CaCO 3 crystallization onto polysaccharide-coated nanoparticles

Polysaccharides and proteoglycans are widely associated with the organic matrix at sites of CaCO 3 biomineralization, and previous studies indicate that these macromolecules may confer greater roles in mineral nucleation than previously recognized. This investigation uses in situ liquid-phase transmission electron microscopy (LP-TEM) to observe CaCO 3 nucleation onto aminated silica (SiO 2 –NH 3 + ) nanoparticles treated with a layer of chitosan (near-neutral derivative of chitin) or heparin (a carboxylated and highly sulfated glycosaminoglycan). In the absence of polysaccharides, few CaCO 3 particles formed and exhibited mobility. However, the SiO 2 –NH 3 + nanoparticles were enveloped in a region of higher mass density relative to the bulk solution, suggesting the development of a local solute-rich environment that surrounds the charged NH 3 + groups. The heparin- or chitosan-coated silica particles also exhibited regions of higher mass density around the nanoparticles. In the presence of these polysaccharide coatings, we observed the nucleation of abundant CaCO 3 particles whereby the polyanionic heparin promoted more nucleation than the weakly cationic chitosan. Many crystallites appeared to form at the polysaccharide–TEM cell membrane–solution interface, further indicating interfacial and macromolecule-specific control on crystallization. The combined results demonstrate that chitosan and heparin have an appreciable effect on the timing, size, and location of CaCO 3 nucleation compared to the polysaccharide-free nanoparticles.

15 GEOTHERMAL ENERGY↗

ITER ECH Transmission Line System Design and Status

The electron cyclotron (EC) heating & current drive (H&CD) system on ITER provides plasma heating by generating, transmitting, and launching high-intensity, high-frequency (170 GHz) electromagnetic wave energy steerable across the plasma cross-section. The transmission line (TL) subsystem connects the Matching Optics Unit (MOU) on each of the 24 gyrotrons to the 32 feed points in the four upper launchers and the 24 feed points in the equatorial launcher. Each TL must be able to operate at up to 1.2 MW of input power for up to 1 hour pulse lengths. The TL system contains 50 mm water-cooled corrugated waveguide, 90o miter bends, 140o miter bends, polarizer miter bend pairs, switches, expansion units, pumpouts, DC breaks, MOU-TL adapters, Radio Frequency (RF) loads, and isolation shutter valves. A detailed finite element analysis has been used to verify the thermo-mechanical performance of each component. The microwave performance has been analyzed using a 2-D electromagnetic code combined with a Monte Carlo code. This approach allows the impact of manufacturing and installation tolerances to be assessed and optimized to provide a high probability of achieving the system performance requirements. Prototypes of the waveguide and TL components have been fabricated and tested at high-power. Production contracts are now being issued for fabrication and delivery of the waveguide and components to ITER.

Hanson, Gregory↗

Feasibility study of a compact neutron resonance transmission analysis instrument

Neutron Resonance Transmission Analysis (NRTA) uses resonant absorption of neutrons to infer the absolute isotopic composition of a target object, enabling applications in a broad range of fields such as archaeology, enrichment analysis of nuclear fuel, and arms control treaty verification. In the past, NRTA involved large user facilities and complex detector systems. However, recent advances in the intensity of compact neutron sources have made compact neutron imaging designs increasingly feasible. This work describes the Monte Carlo (MC) based design of a compact epithermal NRTA radiographic instrument which uses a moderated, compact deuterium-tritium (DT) neutron source and an epithermal neutron detector. Such an instrument would have a wide range of applications, and would be especially impactful for such scenarios as nuclear inspection and arms control verification exercises, where system complexity and mobility may be of critical importance. The MC simulations presented in this work demonstrate accurate time-of-flight (TOF) reconstructions for transmitted neutron energies, capable of differentiating isotopic compositions of nuclear material with high levels of accuracy. A new generation of miniaturized and increasingly more intense neutron sources will allow this technique to achieve measurements with greater precision and speed, with significant impact on a variety of engineering and societal problems.

47 OTHER INSTRUMENTATION↗

Deformation of Néel-type skyrmions revealed by Lorentz transmission electron microscopy

Néel-type magnetic skyrmions in multilayers are promising candidates for ultra-low power spintronic devices. To image the Néel-type skyrmions using Lorentz transmission electron microscopy (L-TEM), the samples must be tilted. Thus, the external magnetic field consists of both in-plane and out-of-plane components. To date, it is still not well known on the effect of the in-plane magnetic field on the L-TEM images, leading to ambiguities in retrieving the structure of Néel-type skyrmions. Here, Néel-type skyrmions in three [Pt/Co/Ta]$_{20}$ multilayer samples, with the easy magnetization axis being tuned from the out-of-plane to the in-plane direction by increasing the Co thickness from 1.8 to 2.2 nm, are imaged. When using a smaller defocus value (-2 mm) and a higher magnification (×9100) of L-TEM, a surprising dark-bright-dark-bright double contrasted pattern, instead of the previously reported dark-bright contrasted pattern, is observed. The additional dark-bright contrasted pattern becomes more evident for thicker Co layer samples in which the magnetization axis tilts more toward the in-plane direction. Further analysis, via a combination of magnetic force microscopy experiments, micromagnetic simulations, and micromagnetic analysis to Lorentz TEM simulation, shows that the additional dark-bright features originate from the deformation of the Néel-type skyrmions within an in-plane magnetic field.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

A graphene-based magnetoplasmonic metasurface for actively tunable transmission and polarization rotation at terahertz frequencies

The rise of terahertz (THz)-based technologies has prompted intense interest in methods for manipulating the properties of THz radiation. In this Letter, we experimentally demonstrate a graphene micro-ribbon-based metasurface that allows us to tailor and dynamically tune the transmission and polarization rotation spectra of impinging THz pulses. This is achieved by controlling the geometry of the ribbon pattern and the applied DC magnetic field, both of which strongly influence the magnetoplasmonic response of the metasurface. The properties of the metasurface can be accurately modeled using an effective medium approach that considers the capacitive interaction of the ribbons resulting from the THz electric field. Furthermore, our results highlight the promise of graphene-based THz devices that leverage the strongly enhanced light–matter interactions resulting from patterning.

36 MATERIALS SCIENCE↗

Reconstruction of the interatomic forces from dynamic scanning transmission electron microscopy data

We explore the possibility for reconstruction of the generative physical models describing interactions between atomic units in solids from observational electron microscopy data. In this work, scanning transmission electron microscopy (STEM) is used to observe the dynamic motion of Si atoms at the edge of monolayer graphene under continuous electron beam illumination. The resulting time-lapsed STEM images represent the snapshots of observed chemical states of the system. We use two approaches: potential of mean force calculation using a radial distribution function and a direct fitting of the graphene–Si interatomic pairwise potentials with force matching, to reconstruct the force fields in the materials. These studies lay the foundation for quantitative analysis of materials energetics from STEM data through the sampling of the metastable states in the chemical space of the system.

42 ENGINEERING↗

Measurement of L-shell emission from mid-Z targets under non-LTE conditions using Transmission Grating Spectrometer and DANTE power diagnostics

In this work, we present the measurement of L-band emission from buried Sc/V targets in experiments performed at the OMEGA laser facility. The goal of these experiments was to study non-local thermodynamic equilibrium plasmas and benchmark atomic physics codes. The L-band emission was measured simultaneously by the time resolved DANTE power diagnostic and the recently fielded time integrated Soreq-Transmission Grating Spectrometer (TGS) diagnostic. The TGS measurement was used to support the spectral reconstruction process needed for the unfolding of the DANTE data. The Soreq-TGS diagnostic allows for broadband spectral measurement in the 120 eV–2000 eV spectral band, covering L- and M-shell emission of mid- and high-Z elements, with spectral resolution λ/Δλ = 8–30 and accuracy better than 25%. The Soreq-TGS diagnostic is compatible with ten-inch-manipulator platforms and can be used for a wide variety of high energy density physics, laboratory astrophysics, and inertial confinement fusion experiments.

Fraenkel, M. (ORCID:0000000291939544)↗

The inductively driven transmission line: A passively coupled device for diagnostic applications on the Z pulsed power facility

The inductively driven transmission line (IDTL) is a miniature current-carrying device that passively couples to fringe magnetic fields in the final power feed on the Z Pulsed Power Facility. The IDTL redirects a small amount of Z’s magnetic energy along a secondary path to ground, thereby enabling pulsed power diagnostics to be driven in parallel with the primary load for the first time. IDTL experiments and modeling presented here indicate that IDTLs operate non-perturbatively on Z and that they can draw in excess of 150 kA of secondary current, which is enough to drive an X-pinch backlighter. Further experiments show that IDTLs are also capable of making cleaner, higher-fidelity measurements of the current flowing in the final feed.

47 OTHER INSTRUMENTATION↗

Additively manufactured electrodes for plasma and power-flow studies in high-power transmission lines on the 1-MA MAIZE facility

Power-flow studies on the 30-MA, 100-ns Z facility at Sandia National Laboratories have shown that plasmas in the facility’s magnetically insulated transmission lines (MITLs) and double post-hole convolute can result in a loss of current delivered to the load. To study power-flow physics on the 1-MA, 100-ns MAIZE facility at the University of Michigan, planar MITL loads and planar post-hole convolute loads have been developed that extend into the lines of sight for various imaging diagnostics on MAIZE. These loads use 3D-printed dielectric support structures lined with thin foils of either aluminum or stainless steel. Here, the metal foils serve as the current-carrying power-flow surfaces, which generate plasma during the current pulse. The foil thickness (50 µm) and widths (11.5–16 mm) are selected to ensure a sufficient linear current density (0.5–0.7 MA/cm) for plasma formation. Laser backlighting (532 nm) and visible-light self-emission imaging capture the overall plasma evolution in the anode–cathode gaps, including the gap closure velocities (1–4 cm/μs).

47 OTHER INSTRUMENTATION↗

High kinetic inductance NbTiN superconducting transmission line resonators in the very thin film limit

Here, we examine the DC and radio frequency (RF) response of superconducting transmission line resonators comprised of very thin NbTiN films, <12 nm in thickness, in the high-temperature limit, where the photon energy is less than the thermal energy. The resonant frequencies of these superconducting resonators show a significant nonlinear response as a function of RF input power, which can approach a frequency shift of Δf=-0.15% in a -20 dB span in the thinnest film. The strong nonlinear response allows these very thin film resonators to serve as high kinetic inductance parametric amplifiers.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

A fiber-coupled dispersion interferometer for density measurements of pulsed power transmission line electron sheaths on Sandia’s Z machine

A fiber-coupled Dispersion Interferometer (DI) is being developed to measure the electron density of plasmas formed in power flow regions, such as magnetically insulated transmission lines, on Sandia National Laboratories (SNL’s) Z machine [D. B. Sinars et al., Phys. Plasmas 27, 070501 (2020)]. The diagnostic operates using a fiber-coupled 1550 nm CW laser with frequency-doubling to 775 nm. The DI is expected to be capable of line-average density measurements between ∼1013 and 1019 cm−2. Initial testing has been performed on a well-characterized RF lab plasma [A. G. Lynn et al., Rev. Sci. Instrum. 80, 103501 (2009)] at the University of New Mexico to quantify the density resolution lower limits of the DI. Initial testing of the DI has demonstrated line-average electron density measurements within 9% of results acquired via a 94 GHz mm wave interferometer for line densities of ∼1 × 1014 cm−2, despite significant differences in probe beam geometries. The instrument will next be utilized for measurements on a ∼1 MA-scale pulsed power driver {MYKONOS [N. Bennett et al., Phys. Rev. Accel. Beams 22, 120401 (2019)] at SNL} before finally being deployed on SNL’s Z machine. The close electrode spacing (mm scale) on Z requires probe beam sizes of ∼1 mm, which can only be obtained with visible or near infrared optical systems, as opposed to longer wavelength mm wave systems that would normally be chosen for this range of density.

Hines, N. R. (ORCID:0000000315316465)↗

Element-specific first order reversal curves measured by magnetic transmission x-ray microscopy

The first-order reversal curve (FORC) method is a macroscopic measurement technique that can be used to extract quantitative and microscopic properties of hysteretic systems. Using magnetic transmission x-ray microscopy (MTXM), local element-specific FORC measurements are performed on a 20 nm thick film of CoTb. The FORCs measured with microscopy reveal a step-by-step domain evolution under the magnetic field cycling protocol and provide a direct visualization of the mechanistic interpretation of FORC diagrams. They are compared with magnetometry FORCs and show good quantitative agreement. Furthermore, the high spatial resolution and element-specific sensitivity of MTXM provide new capabilities to measure FORCs in small regions or specific phases within multicomponent systems, including buried layers in heterostructures. The ability to perform FORCs on very small features is demonstrated with the MTXM-FORC measurement of a rectangular microstructure with vortex-like Landau structures. This work demonstrates the confluence of two uniquely powerful techniques to achieve quantitative insight into nanoscale magnetic behavior.

36 MATERIALS SCIENCE↗

Circuit-level design principles for transmission-mode microwave impedance microscopy

A recently developed technique of transmission-mode microwave impedance microscopy (T-MIM) has greatly extended the capabilities of standard reflection-mode MIM to novel applications, such as the in operando study of nanoscale electro-acoustic devices. As is common for new techniques, systematic design principles for boosting sensitivity and balancing bandwidth are lacking. Here, we show numerically and analytically that the T-MIM signal is proportional to the reflection-mode voltage enhancement factor η of the circuit, as long as the output impedance of the local voltage source is properly treated. We show that this proportionality holds in the currently achievable “weak sampling” regime and beyond, for which we demonstrate a realistic path with commercially available superconducting components and critically coupled impedance matching networks. Furthermore, we demonstrate that for these next-generation designs, the sensitivity is generally maximized at a slightly different frequency from the unloaded S 11 resonance, which can be explained by the maximum power transfer theorem.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Spin-dependent charge transmission through chiral 2T3N self-assembled monolayer on Au

In this study, a gold surface is functionalized by chemisorption of the enantiopure N,N'-bis-[2,2';5',2"]tert-thiophene-5-yl methylcyclohexane-1,2-diamine (2T3N), a chiral oligothiophene derivative, via overnight incubation in a 2T3N ethanol solution. The Au|2T3N interface is characterized by x-ray photoelectron circular dichroism and comparing x-ray photoemission spectroscopy and electro-desorption results. Charge transmission at the Au|2T3N| solution interface is characterized by recording the cyclic voltammetry of the Fe(III)/Fe(II) reversible redox couple, finding a charge transfer rate constant, k°, variation from 1 × 10 -1 to 3.3 × 10 -2 cm s -1 , when comparing the bare Au and the Au|2T3N interfaces, respectively. The “anomalous” high value of k° found for the chiral Au|2T3N interface can be rationalized on the basis of the chiral-induced spin selectivity effect, as further proved by magnetic–conductive atomic force microscopy measurements at room temperature. A spin polarization of about 30% is found.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Power flow in magnetically insulated transmission lines with ion backscatter effects

Ion backscattering off of surfaces in magnetically insulated transmission lines (MITLs) is often ignored in kinetic simulations of MITL power flow. Backscattering reduces ion current losses and the surface impact heating, which dictates the rate at which surface-adsorbed contaminants are liberated into the anode–cathode gap. Backscatter probabilities are difficult to implement in a kinetic code because there are limited data for incident ion energies less than a few keV. This paper presents an analytic model based on the Rutherford scattering formula that reproduces the measured backscatter probabilities at high incident energies and transitions to the highly reflective behavior expected at low incident energies. The backscatter model is implemented in power flow simulations, which are validated with current loss experiments conducted on the 0.4 TW Mykonos accelerator at Sandia National Laboratories. This simulation setup is then used in a high-current Z-machine shot. In conclusion, backscatter effects are found to be unimportant in the low-current Mykonos regime but significantly reduce current losses at the Z-machine scale.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Bayesian inferences of electrical current delivered to shocked transmission lines

Small radius Bdot measurements of electrical current delivered by pulsed power devices are routinely compromised by electrode/convolute plasmas endemic to multiterawatt transmission lines. Inferences of delivered current unaffected by these issues have recently been obtained by numerically optimizing consistency between model predictions and local experimental velocimetry data, but these are only unique for shockless velocity profiles. In the paper we describe a more general Bayesian method capable of inferring current despite the presence of shocks. Additionally, we describe uncertainty estimates and use of the technique on experimental data. This technique is the first to provide uncertainty estimates on the full current trace delivered to an inertial confinement fusion target.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Simulation-trained machine learning models for Lorentz transmission electron microscopy

Understanding the collective behavior of complex spin textures, such as lattices of magnetic skyrmions, is of fundamental importance for exploring and controlling the emergent ordering of these spin textures and inducing phase transitions. It is also critical to understand the skyrmion–skyrmion interactions for applications such as magnetic skyrmion-enabled reservoir or neuromorphic computing. Magnetic skyrmion lattices can be studied using in situ Lorentz transmission electron microscopy (LTEM), but quantitative and statistically robust analysis of the skyrmion lattices from LTEM images can be difficult. In this work, we show that a convolutional neural network, trained on simulated data, can be applied to perform segmentation of spin textures and to extract quantitative data, such as spin texture size and location, from experimental LTEM images, which cannot be obtained manually. This includes quantitative information about skyrmion size, position, and shape, which can, in turn, be used to calculate skyrmion–skyrmion interactions and lattice ordering. We apply this approach to segmenting images of Néel skyrmion lattices so that we can accurately identify skyrmion size and deformation in both dense and sparse lattices. The model is trained using a large set of micromagnetic simulations as well as simulated LTEM images. This entirely open-source training pipeline can be applied to a wide variety of magnetic features and materials, enabling large-scale statistical studies of spin textures using LTEM.

McCray, Arthur R. C. (ORCID:0000000160774698)↗

Transmission interference fringe ( TIF ) technique for the dynamic visualization of evaporating droplet

Here, the transmission interference fringe (TIF) technique was developed to visualize the dynamics of evaporating droplets based on the Reflection Interference Fringe (RIF) technique for micro-sized droplets. The geometric formulation was conducted to determine the contact angle (CA) and height of macro-sized droplets without the need for the prism used in RIF. The TIF characteristics were analyzed through experiments and simulations to demonstrate a wider range of contact angles from 0 to 90°, in contrast to RIF's limited range of 0–30°. TIF was utilized to visualize the dynamic evaporation of droplets in the constant contact radius (CCR) mode, observing the droplet profile change from convex-only to convex-concave at the end of dry-out from the interference fringe formation. The TIF also observed the contact angle increase from the fringe radius increase. This observation is uniquely reported as the interference fringe (IF) technique can detect the formation of interference fringe between the reflection from the center convex profile and the reflection from the edge concave profile on the far-field screen. Unlike general microscopy techniques, TIF can detect far-field interference fringes as it focuses beyond the droplet-substrate interface. The formation of the convex-concave profile during CCR evaporation is believed to be influenced by the non-uniform evaporative flux along the droplet surface.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗