Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “transient analysis”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,135 records · Page 63

Displaying Data From Duct/Fluid Calculations

DUCT6D is FORTRAN program for enhancing postprocessing of data computed by programs based on line-element mathematical models, especially dynamical models of ducts and fluids contained in them. Based partly on assumption that coupled duct/fluid-dynamic system analyzed by use of line elements representing beam properties of duct and one-dimensional acoustical properties of fluid. Inputs include geometric data from model and static, modal, or transient-displacement data from solution. Output represents geometry of coupled duct/fluid system and results of analysis by use of three-dimensional shell elements. Written in FORTRAN.

Saxon, Joe B.↗

Gamma-Ray Burst Arrival Time Localizations: Simultaneous Observations by Mars Observer, Compton Gamma Ray Observatory and Ulysses

Between 1992 October 4 and 1993 August 1, concurrent coverage by the Compton Gamma Ray Observatory (CGRO), Mars Observer (MO), and Ulysses spacecraft was obtained for 78 gamma-ray bursts (GRBs). Although most of these were below the MO and Ulysses thresholds, nine were positively detected by all three spacecraft, with data quality adequate for quantitative localization analysis. All were localized independently to approximately 2 deg accuracy by the CGRO Burst and Transient Source Experiment (BATSE). We computed arrival-time error boxes with larger dimensions ranging from a few arcminutes to the diameters of the BATSE-only boxes and with smaller dimensions in the arcminute range. Three events are of particular interest: GB 930704 (BATSE 2428) has been described as a possible repeater. The arrival-time information is consistent with that hypothesis, but only just so. The GB 930706 (2431) box, at approximately 1 min x 4 min, is the only one this small obtained since Pioneer Venus Orbiter (PVO) entered the Venusian atmosphere in 1992 October. Sensitive radio and optical observations of this location were made within 8 and 9 days of the burst, but no counterpart candidates were identified. GB 930801 (2477) is the first GRB that had its localization improved by taking into account BATSE Earth occultation.

Laros, J. G.↗

Serendipitous Detections of XTE J1906+09 with the Rossi X-ray Timing Explorer

In 1996 during Rossi X-ray Timing Explorer (RXTE) observations of SCR 1900+14, the 89-second X-ray pulsar XTE J1906+09 was discovered. As a result of monitoring campaigns of SGR 1900+14, XTE J1906+09 was also monitored regularly in 1996 September, 1998 May-June, 1998 August-1999 July, and 2000 March-2001 January. A frequency grid search of these observations resulted in detections of only the two previously reported outbursts in 1996 September and 1998 August-September. The non-detection of XTE J1906+09 in most observations indicates that it is a transient X-ray pulsar and therefore likely has a Be star companion, Pulse timing analysis of the second outburst revealed a sinusoidal signature in the pulse frequencies that is likely produced by periastron passage in a long period, eccentric, orbit. During the second outburst, the pulse shape changed with increasing intensity, Low intensity pulse profiles from the second outburst are consistent with profiles from the fainter first outburst. Energy dependent pulse shape variations were seen in both outbursts. Pulse phase spectroscopy was used to quantify these variations. The phase averaged spectrum, using the pulse minimum spectrum as the background spectrum to eliminate effects from SGR 1900+14 and the galactic ridge, was well fitted by an absorbed power law with a high energy cutoff with column density N(sub H) = (6 +/- 1) x 10(exp 22) cm(sup -2), photon index = 1.01 +/- 0.08, cutoff energy E(sub cut) = 11 +/- 1 keV, and folding energy E(sub fold) = 19 +/- 4 keV.

Wilson, Colleen A.↗

Design Strategy for a Formally Verified Reliable Computing Platform

This paper presents a high-level design for a reliable computing platform for real-time control applications. The design tradeoffs and analyses related to the development of a formally verified reliable computing platform are discussed. The design strategy advocated in this paper requires the use of techniques that can be completely characterized mathematically as opposed to more powerful or more flexible algorithms whose performance properties can only be analyzed by simulation and testing. The need for accurate reliability models that can be related to the behavior models is also stressed. Tradeoffs between reliability and voting complexity are explored. In particular, the transient recovery properties of the system are found to be fundamental to both the reliability analysis as well as the "correctness" models.

Butler, Ricky W.↗

Design and Assembly of an Integrated Metabolic Heat Regenerated Temperature Swing Adsorption (MTSA) Subassembly Engineering Development Unit

Metabolic heat regenerated Temperature Swing Adsorption (MTSA) technology is being developed for thermal and carbon dioxide (CO2) control for a Portable Life Support System (PLSS), as well as water recycling. The core of the MTSA technology is a sorbent bed that removes CO2 from the PLSS ventilation loop gas via a temperature swing. A Condensing Ice Heat eXchanger (CIHX) is used to warm the sorbent while also removing water from the ventilation loop gas. A Sublimation Heat eXchanger (SHX) is used to cool the sorbent. Research was performed to explore an MTSA designed for both lunar and Martian operations. Previously each the sorbent bed, CIHX, and SHX had been built and tested individually on a scale relevant to PLSS operations, but they had not been done so as an integrated subassembly. Design and analysis of an integrated subassembly was performed based on this prior experience and an updated transient system model. Focus was on optimizing the design for Martian operations, but the design can also be used in lunar operations. An Engineering Development Unit (EDU) of an integrated MTSA subassembly was assembled based on the design. Its fabrication is discussed. Some details on the differences between the as-assembled EDU to the future flight unit are considered.

Padilla, Sebastian A.↗

Design and Assembly of an Integrated Metabolic Heat Regenerated Temperature Swing Adsorption (MTSA) Subassembly Engineering Development Unit

Metabolic heat regenerated Temperature Swing Adsorption (MTSA) technology is being developed for thermal and carbon dioxide (CO2) control for a Portable Life Support System (PLSS), as well as water recycling. The core of the MTSA technology is a sorbent bed that removes CO2 from the PLSS ventilation loop gas via a temperature swing. A Condensing Icing Heat eXchanger (CIHX) is used to warm the sorbent while also removing water from the ventilation loop gas. A Sublimation Heat eXchanger (SHX) is used to cool the sorbent. Research was performed to explore an MTSA designed for both lunar and Martian operations. Previously the sorbent bed, CIHX, and SHX had been built and tested individually on a scale relevant to PLSS operations, but they had not been done so as an integrated subassembly. Design and analysis of an integrated subassembly was performed based on this prior experience and an updated transient system model. Focus was on optimizing the design for Martian operations, but the design can also be used in lunar operations. An Engineering Development Unit (EDU) of an integrated MTSA subassembly was assembled based on the design. Its fabrication is discussed. Some details on the differences between the as-assembled EDU and the future flight unit are considered.

Padilla, Sebastian A.↗

Influence of exit impedance on finite difference solutions of transient acoustic mode propagation in ducts

The time-dependent governing acoustic-difference equations and boundary conditions are developed and solved for sound propagation in an axisymmetric (cylindrical) hard-wall duct without flow and with spinning acoustic modes. The analysis begins with a harmonic sound source radiating into a quiescent duct. This explicit iteration method then calculates stepwise in real time to obtain the steady solutions of the acoustic field. The transient method did not converge to the steady-state solution for cutoff acoustic duct modes. This has implications as to its use in a variable-area duct, where modes may become cutoff in the smal-area portion of the duct. For single cutoff mode propagation the steady-state impedance boundary condition produced acoustic reflections during the initial transient that caused finite instabilities in the numerical calculations. The stability problem is resolved by reformulating the exit boundary condition. Example calculations show good agreement with exact analytical and numerical results for forcing frequencies above, below, and nearly at the cutoff frequency.

Baumeister, K. J.↗

Portable Life Support Subsystem Thermal Hydraulic Performance Analysis

This paper presents the current state of the thermal hydraulic modeling efforts being conducted for the Constellation Space Suit Element (CSSE) Portable Life Support Subsystem (PLSS). The goal of these efforts is to provide realistic simulations of the PLSS under various modes of operation. The PLSS thermal hydraulic model simulates the thermal, pressure, flow characteristics, and human thermal comfort related to the PLSS performance. This paper presents modeling approaches and assumptions as well as component model descriptions. Results from the models are presented that show PLSS operations at steady-state and transient conditions. Finally, conclusions and recommendations are offered that summarize results, identify PLSS design weaknesses uncovered during review of the analysis results, and propose areas for improvement to increase model fidelity and accuracy.

Barnes, Bruce↗

Improved fluid dynamics similarity, analysis and verification. Part 5: Analytical and experimental studies of thermal stratification phenomena

The stratification behavior of a contained fluid subjected to transient free convection heat transfer was studied. A rectangular vessel was employed with heat transfer from two opposite walls of the vessel to the fluid. The wall temperature was increased suddenly to initiate the process and was then maintained constant throughout the transient stratification period. Thermocouples were positioned on a post at the center of the vessel. They were adjusted so that temperatures could be measured at the fluid surface and at specific depths beneath the surface. The predicted values of the surface temperature and the stratified layer thickness were found to agree reasonably well with the experimental measurements. The experiments also provided information on the transient centerline temperature distribution and the transient flow distribution.

Winter, E. R. F.↗

Analysis of wave propagation in elastic cylindrical shells by the perturbation method.

Description of the perturbation method for solving propagation problems of transient, axisymmetric stress waves in elastic cylindrical shells. It is shown that the method provides remarkably accurate solutions for these problems and that it can be applied to a variety of related problems, such as the propagation of compressional waves in elastic rods.

Geers, T. L.↗

Solution of enforced boundary motion in direct transient and harmonic problems

The current versions of NASTRAN, i.e., NASA, MSC, and MAC support nonzero boundary displacements only in the static analysis. Forcing functions in the dynamic analysis formats allow only forces and pressures to exercise the mathematical model. A DMAP alter sequence to circumvent this limitation is described. For the direct harmonic problem, a simple change to module FRRD is incorporated to effect a more efficient use of the code.

Fox, G. L.↗

Analysis, testing, and evaluation of faulted and unfaulted Wye, Delta, and open Delta connected electromechanical actuators

Mathematical models capable of simulating the transient, steady state, and faulted performance characteristics of various brushless dc machine-PSA (power switching assembly) configurations were developed. These systems are intended for possible future use as primemovers in EMAs (electromechanical actuators) for flight control applications. These machine-PSA configurations include wye, delta, and open-delta connected systems. The research performed under this contract was initially broken down into the following six tasks: development of mathematical models for various machine-PSA configurations; experimental validation of the model for failure modes; experimental validation of the mathematical model for shorted turn-failure modes; tradeoff study; and documentation of results and methodology.

Nehl, T. W.↗

Transfinite element methodology for nonlinear/linear transient thermal modelling/analysis - Progress and recent advances

The 'transfinite element method' (TFEM) proposed by Tamma and Railkar (1987 and 1988) for the analysis of linear and nonlinear heat-transfer problems is described and demonstrated. The TFEM combines classical Galerkin and transform approaches with state-of-the-art FEMs to obtain a flexible hybrid modeling scheme. The fundamental principles of the TFEM and the derivation of the governing equations are reviewed, and numerical results for sample problems are presented in extensive graphs and briefly characterized. Problems analyzed include a square plate with a hole, a rectangular plate with natural and essential boundary conditions and varying thermal conductivity, the Space Shuttle thermal protection system, a bimaterial plate subjected to step temperature variations, and solidification in a semiinfinite liquid slab.

Tamma, Kumar K.↗

Electro-impulse de-icing testing analysis and design

Electro-Impulse De-Icing (EIDI) is a method of ice removal by sharp blows delivered by a transient electromagnetic field. Detailed results are given for studies of the electrodynamic phenomena. Structural dynamic tests and computations are described. Also reported are ten sets of tests at NASA's Icing Research Tunnel and flight tests by NASA and Cessna Aircraft Company. Fabrication of system components are described and illustrated. Fatigue and electromagnetic interference tests are reported. Here, the necessary information for the design of an EIDI system for aircraft is provided.

Zumwalt, G. W.↗

Systems Improved Numerical Fluids Analysis Code

Systems Improved Numerical Fluids Analysis Code, SINFAC, consists of additional routines added to April, 1983, version of SINDA. Additional routines provide for mathematical modeling of active heat-transfer loops. Simulates steady-state and pseudo-transient operations of 16 different components of heat-transfer loops, including radiators, evaporators, condensers, mechanical pumps, reservoirs, and many types of valves and fittings. Program contains property-analysis routine used to compute thermodynamic properties of 20 different refrigerants. Source code written in FORTRAN 77.

Costello, F. A.↗

1-D Transient Thermal Modeling of an Ablative Material (MCC-1) Exposed to a Simulated Convective Titan 4 Launch Environment

The purpose of the work is to demonstrate that the flat test panel substrate temperatures are consistent with analysis predictions for MCC-1 applied to a aluminum substrate. The testing was performed in an aerothermal facility on samples of three different thicknesses of MCC-1 on an aluminum substrate. The results of the test were compared with a Transient Thermal model. The key assumptions of the Transient Thermal model were: (1) a one-dimensional heat transfer; (2) a constant ablation recession rate (determined from pre and post-test measurements); (3) ablation temperature of 540 degrees F; (4) Char left behind the ablation front; and (5) temperature jump correction for incident heat transfer coefficient. Two methods were used to model the heating of bare MCC-1: (1) Directly input surface temperature as a function of time; and (2) Aerothermal heating using calibration plate data and subtracting the radiation losses to tunnel walls. The results are presented as graphs. This article is presented in Viewgraph format.

Reinarts, Thomas R.↗

Hybrid Automated Diagnosis of Discrete/Continuous Systems

A recently conceived method of automated diagnosis of a complex electromechanical system affords a complete set of capabilities for hybrid diagnosis in the case in which the state of the electromechanical system is characterized by both continuous and discrete values (as represented by analog and digital signals, respectively). The method is an integration of two complementary diagnostic systems: (1) beacon-based exception analysis for multi-missions (BEAM), which is primarily useful in the continuous domain and easily performs diagnoses in the presence of transients; and (2) Livingstone, which is primarily useful in the discrete domain and is typically restricted to quasi-steady conditions. BEAM has been described in several prior NASA Tech Briefs articles: "Software for Autonomous Diagnosis of Complex Systems" (NPO-20803), Vol. 26, No. 3 (March 2002), page 33; "Beacon-Based Exception Analysis for Multimissions" (NPO-20827), Vol. 26, No. 9 (September 2002), page 32; "Wavelet-Based Real-Time Diagnosis of Complex Systems" (NPO-20830), Vol. 27, No. 1 (January 2003), page 67; and "Integrated Formulation of Beacon-Based Exception Analysis for Multimissions" (NPO-21126), Vol. 27, No. 3 (March 2003), page 74. Briefly, BEAM is a complete data-analysis method, implemented in software, for real-time or off-line detection and characterization of faults. The basic premise of BEAM is to characterize a system from all available observations and train the characterization with respect to normal phases of operation. The observations are primarily continuous in nature. BEAM isolates anomalies by analyzing the deviations from nominal for each phase of operation. Livingstone is a model-based reasoner that uses a model of a system, controller commands, and sensor observations to track the system s state, and detect and diagnose faults. Livingstone models a system within the discrete domain. Therefore, continuous sensor readings, as well as time, must be discretized. To reason about continuous systems, Livingstone uses monitors that discretize the sensor readings using trending and thresholding techniques. In development of the a hybrid method, BEAM results were sent to Livingstone to serve as an independent source of evidence that is in addition to the evidence gathered by Livingstone standard monitors. The figure depicts the flow of data in an early version of a hybrid system dedicated to diagnosing a simulated electromechanical system. In effect, BEAM served as a "smart" monitor for Livingstone. BEAM read the simulation data, processed the data to form observations, and stored the observations in a file. A monitor stub synchronized the events recorded by BEAM with the output of the Livingstone standard monitors according to time tags. This information was fed to a real-time interface, which buffered and fed the information to Livingstone, and requested diagnoses at the appropriate times. In a test, the hybrid system was found to correctly identify a failed component in an electromechanical system for which neither BEAM nor Livingstone alone yielded the correct diagnosis.

Park, Han↗