Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “transformations”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,135 records · Page 63

HERCULES: A Pattern Driven Code Transformation System

New parallel computers are emerging, but developing efficient scientific code for them remains difficult. A scientist must manage not only the science-domain complexity but also the performance-optimization complexity. HERCULES is a code transformation system designed to help the scientist to separate the two concerns, which improves code maintenance, and facilitates performance optimization. The system combines three technologies, code patterns, transformation scripts and compiler plugins, to provide the scientist with an environment to quickly implement code transformations that suit his needs. Unlike existing code optimization tools, HERCULES is unique in its focus on user-level accessibility. In this paper we discuss the design, implementation and an initial evaluation of HERCULES.

99 GENERAL AND MISCELLANEOUS↗

Trace Driven Data Structure Transformations

As the complexity of scientific codes and computational hardware increases it is increasingly important to study the effects of data-structure layouts on program memory behavior. Program structure layouts affect the memory performance differently, therefore we need the capability to effectively study such transformations without the need to rewrite application codes. Trace-driven simulations are an effective and convenient mechanism to simulate program behavior at various granularities. During an application s execution, a tool known as a tracer or profiler, collects program flow data and records program instructions. The trace-file consists of tuples that associate each program instruction with program internal variables. In this paper we outline a proof-of-concept mechanism to apply data-structure transformations during trace simulation and observe effects on memory without the need to manually transform an application s code.

cache locality↗

Dynamic-Phasor Model of Transformer Inrush Simulation for Unbalanced Distribution System

Abstract— Power system stability is a critical concern, with respect to the increasing distributed energy resources, microgrids, and emphasis on enhancing resiliency. For stability analysis and evaluation, modeling and simulation capabilities are important. In this paper, the authors’ previous work on modeling transformer inrush dynamics is improved with a new formulation of the key equation that converts the dynamic-phasor into real-time value. Simulation results in an electromechanical time-scale are compared with PSCAD results in an electromagnetic time-scale to demonstrate the improvement. The impact of simulation step size is discussed. A bug in PSCAD transformer setting that leads to incorrect magnetizing flux and current under Delta winding type is identified and reported. In addition, explanations and analysis are provided on two modeling techniques utilized since the previous work. This work is being incorporated into the next release of GridLAB-D. The improved transformer inrush calculation enables more accurate predictions of current amplitudes for analyzing the dynamics of distribution operation and control.

power transformers, power system simulation, satur↗

Understanding Line Losses and Transformer Losses in Rural Isolated Distribution Systems: Preprint

Rural, isolated power systems in the mainland U.S. and in states like Alaska and Hawaii are powered by assets like diesel generators. These rural, isolated power systems also cannot operate at the higher band of medium voltage (like 69kV). They are primarily in the 12 to 14 kV range to keep the cost of the distribution investments lower. Because of this mid-band medium voltage range, the line losses and distribution transformers losses consume significant diesel consumption (almost 10 percent of the peak load). This work considers one such power system powering an isolated system and presents key findings online losses, and transformer losses. Understanding and documenting the impacts is critical for these communities operating their power systems and take actions to reduce expensive diesel consumption. In this paper, we will present one such typical grid and model it in electromagnetic transients (EMT) domain. We used the tower structure, under ground cabling installation to develop high fidelity models of lines. We also used high fidelity models of distribution transformers to present the no-load losses and full load loses. We will also present technical solutions available commercially off-the-shelf to reduce these losses and reduce diesel consumption. This work will be a primer for communities to understand the technical challenges and to understand the possible solution available to solve such challenges for rural, isolated power system operators.

blackstart↗

New Transformer Testing Approach Reduces Reactor Down Time

The ATR-774 transformer yard has been in operation for 57 years. It's old, outdated, and reaching end of life. Plant health has decided to construct a new transformer yard, which will require testing. I've explored the standards library and compiled a list of tests that need to be performed on the transformer yard. This effort led to a significant speed-up in the testing process.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Seismic Resilience of Large Power Transformer Bushings & Non-SF6 Industrial Base Scan Review

Large (high voltage) power transformers (LPT), and more specifically, their bushings, are known to be susceptible to seismic failure. With bushing failure, a transformer will have to be replaced, which has a considerable lead time, adding to the power outage duration. Cost-efficient, proven solutions are not currently available to mitigate this risk, which can persist for the more than 30-year life of a particular transformer. This work will focus on developing and demonstrating a hardware solution to address seismic vulnerabilities and reduce outage risks from LPT failure. Sulfur Hexafluoride (SF6) is a specialty gas with excellent electrical insulation properties which has been used extensively in the power industry. This gas is unfortunately also one of the most potent greenhouse gases known to humanity. A 2014 report by the Intergovernmental Panel on Climate Change found that SF6 has a global warming potential (GWP) 23,000 times higher than Carbon Dioxide, and has the highest GWP of all gases assessed (Myhre 2013). SF6 is almost exclusively man-made and is produced for use as an insulator in high voltage electrical equipment. This makes the production and use of SF6 one of the leading sources of anthropogenic climate change. To fully eliminate the environmental impacts of SF6, alternative technology is needed. The ideal replacement would be a technology that can fulfil the same role as SF6, at the same cost or cheaper, but without adverse environmental effects. Currently, no technology fits this description, however several promising technologies have begun to enter the market. An industry scan was performed to assess the state of industry adoption and manufacturing capability for SF6-free alternative technologies for use at the high-voltage level, and the primary barriers to broader adoption.

10 SYNTHETIC FUELS↗

In-situ Phase Transformation and Deformation of Iron at High Pressure andTemperature

With a membrane based mechanism to allow for pressure change of a sample in aradial diffraction diamond anvil cell (rDAC) and simultaneous infra-red laser heating, itis now possible to investigate texture changes during deformation and phasetransformations over a wide range of temperature-pressure conditions. The device isused to study bcc (alpha), fcc (gamma) and hcp (epislon) iron. In bcc iron, room temperature compression generates a texture characterized by (100) and (111) poles parallel to the compression direction. During the deformation induced phase transformation to hcp iron, a subset of orientations are favored to transform to the hcp structure first and generate a texture of (01-10) at high angles to the compression direction. Upon further deformation, the remaining grains transform, resulting in a texture that obeys the Burgers relationship of (110)bcc // (0001)hcp. This is in contrast to high temperature results that indicate that texture is developed through dominant pyramidal<a+c> {2-1-12}<2-1-13> and basal (0001)-{2-1-10} slip based on polycrystal plasticity modeling. We also observe that the high temperature fcc phase develops a 110 texture typical for fcc metals deformed in compression.

36 MATERIALS SCIENCE↗

In-Situ Raman Indentation of ??-Eucryptite: Characterization of the Pressure Induced Phase Transformation

A pressure-induced phase transformation in the lithium aluminum silicate -eucryptite was studied with in-situ Raman spectroscopy. Dense -eucryptite composites were made via powder synthesis followed by sintering. The specimens were then subjected to diamond indentation up to applied contact stresses of about 8 GPa, while collecting Raman spectra. The appearance of a Raman peak (~520 cm-1) at a contact stress of about 3 GPa likely corresponds to the reversible phase transformation of -eucryptite to the orthorhombic phase -eucryptite. Loading and unloading in-situ Raman indentation experiments are discussed with regards to this transformation.

36 MATERIALS SCIENCE↗

Fourier-transform spectroscopy and coupled-channels deperturbation treatment of the A {sup 1{Sigma}+}-b {sup 3{Pi}} complex of KCs

The laser-induced fluorescence (LIF) A {sup 1{Sigma}+}-b {sup 3{Pi}{yields}}X {sup 1{Sigma}+} spectra of the KCs molecule were recorded in a near infrared region by a Fourier-transform spectrometer with a resolution of 0.03 cm{sup -1}. Overall more than 200 collisionally enhanced LIF spectra were rotationally assigned to {sup 39}K{sup 133}Cs and {sup 41}K{sup 133}Cs isotopomers yielding more than 3400 rovibronic term values of the strongly mixed singlet A {sup 1{Sigma}+} and triplet b {sup 3{Pi}} states with the uncertainty of 0.003-0.01 cm{sup -1}. Experimental data massive starts from the lowest vibrational level v{sub A}=0 of the singlet and nonuniformly covers the energy range E is an element of [10 040,13 250] cm{sup -1} with rotational quantum numbers J{sup '} is an element of [7,225]. Besides the dominating regular A {sup 1{Sigma}+}-b {sup 3{Pi}}{sub {Omega}=0} interactions, the weak local heterogeneous A {sup 1{Sigma}+}-b {sup 3{Pi}}{sub {Omega}=1} perturbations have been discovered and analyzed. Coupled-channels deperturbation analysis of the experimental {sup 39}K{sup 133}Cs e-parity term values of the A {sup 1{Sigma}+}-b {sup 3{Pi}}{sub {Omega}=0,1,2} complex was accomplished in the framework of the phenomenological 4x4 Hamiltonian accounting implicitly for regular interactions with the remote {sup 1{Pi}} and {sup 3{Sigma}+} states. The diabatic potential energy curves of the A {sup 1{Sigma}+} and b {sup 3{Pi}} states, as well as relevant spin-orbit coupling matrix elements, were defined analytically with the expanded Morse oscillators model. The obtained parameters reproduce 95% of experimental data field of the {sup 39}K{sup 133}Cs isotopomer with a standard deviation of 0.004 cm{sup -1}, which is consistent with the uncertainty of the experiment. Reliability of the derived parameters was confirmed by a good agreement between the predicted and experimental term values of the {sup 41}K{sup 133}Cs isotopomer. The calculated relative intensity distributions in A-b{yields}X LIF progressions are also consistent with their experimental counterparts. The deperturbation model was applied for simulation of a pump-dump optical cycle a {sup 3{Sigma}+{yields}}A {sup 1{Sigma}+}-b {sup 3{Pi}{yields}}X {sup 1{Sigma}+} proposed for transformation of ultracold KCs molecules to their absolute ground state v{sub X}=0;J{sub X}=0.

74 ATOMIC AND MOLECULAR PHYSICS↗

Foldy-Wouthuysen transformation for a Dirac-Pauli dyon and the Thomas-Bargmann-Michel-Telegdi equation

The classical dynamics for a charged point particle with intrinsic spin is governed by a relativistic Hamiltonian for the orbital motion and by the Thomas-Bargmann-Michel-Telegdi equation for the precession of the spin. It is natural to ask whether the classical Hamiltonian (with both the orbital and spin parts) is consistent with that in the relativistic quantum theory for a spin-1/2 charged particle, which is described by the Dirac equation. In the low-energy limit, up to terms of the seventh order in 1/E{sub g} (E{sub g}=2mc{sup 2} and m is the particle mass), we investigate the Foldy-Wouthuysen (FW) transformation of the Dirac Hamiltonian in the presence of homogeneous and static electromagnetic fields and show that it is indeed in agreement with the classical Hamiltonian with the gyromagnetic ratio being equal to 2. Through electromagnetic duality, this result can be generalized for a spin-1/2 dyon, which has both electric and magnetic charges and thus possesses both intrinsic electric and magnetic dipole moments. Furthermore, the relativistic quantum theory for a spin-1/2 dyon with arbitrary values of the gyromagnetic and gyroelectric ratios can be described by the Dirac-Pauli equation, which is the Dirac equation with augmentation for the anomalous electric and anomalous magnetic dipole moments. The FW transformation of the Dirac-Pauli Hamiltonian is shown, up to the seventh-order again, to be in accord with the classical Hamiltonian as well.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Fractional Fourier transform in temporal ghost imaging with classical light

We investigate temporal, second-order classical ghost imaging with long, incoherent, scalar plane-wave pulses. We prove that in rather general conditions, the intensity correlation function at the output of the setup is given by the fractional Fourier transform of the temporal object. In special cases, the correlation function is shown to reduce to the ordinary Fourier transform and the temporal image of the object. Effects influencing the visibility and the resolution are considered. This work extends certain known results on spatial ghost imaging into the time domain and could find applications in temporal tomography of pulses.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Insulation Coordination Design for Grid-Connected Solid-State Transformers

The deployment of solid-state transformers (SSTs) in medium-voltage (MV) distribution systems is facing various challenges, especially the challenge of insulation coordination design against grid-originated lightning impulses. In this article, two challenges in existing insulation coordination designs for grid-connected SSTs are identified. One challenge is the mismatch between metal-oxide varistor (MOV) protective levels and SST insulation strength, the other challenge is the incompatibility of standard impulse test on SST protective structures. To address the MOV selection challenge, a novel lightning protection scheme is designed to protect a single-stage SST where the semiconductor modules are directly exposed to external lightning impulses. Here, the in-lab lightning impulse tests are performed to verify the overvoltage attenuation performance of the prototyped lightning protection scheme. To address the impulse test challenge, the surge withstand capability of the protected SST is comprehensively evaluated with a complete set of insulation coordination design procedures beyond the basic insulation level (BIL) test. After these two challenges are addressed, a discussion is presented on substituting conventional transformers with the protected SSTs into insulation-coordinated distribution systems to facilitate the field deployment of SSTs.

solid-state transformer (SST)↗

Stacked Low-Inertia Converter or Solid-State Transformer: Modeling and Model Predictive Priority-Shifting Control for Voltage Balance

This paper presents control challenges of stacked low-inertia converter (SLIC) or cascaded reduced dc-link solid-state transformer (SST) and proposes a novel model predictive priority-shifting (MPPS) control with implicit modulator and a discrete-time large-signal model for voltage balancing and dc-link regulation. Low-inertia converters, featuring small electrolytic capacitor-less dc links, dramatically reduce cost, size, and weight compared to conventional solutions. However, without a large dc-link buffer, the input and output are tightly coupled, leading to significant control challenges. The control becomes even more challenging with these converters stacked input-series output-parallel (ISOP) for medium-voltage (MV) grid, which causes coupling between the modules besides the coupling within each module. This paper analyzes the multi-objective, multi-degree of freedom control problem, using the modular soft-switching solid-state transformer (M-S4T) as an example of the SLIC. First, distribution of control efforts under controller saturation is critical because multiple control objectives can be conflicting, especially when the module voltages are unbalanced and are being restored. The MPPS can shift the priorities to address this issue. Second, due to the low inertia and high dc-link ripple, classic space vector pulse-width modulation (SVPWM), average model with small-ripple assumption, and control design based on small-signal model cannot accurately modulate, model, and control the nonlinear reduced dc link. Therefore, a discrete-time large-signal model of the M-S4T is established to derive the predictive control in the MPPS. The MPPS and the PI control are compared in MV simulations to show the issue of applying the PI to the SLIC and the effectiveness of the MPPS for voltage balancing and dc-link regulation in a deadbeat manner. Finally, the proposed control is tested on a 5 kV ISOP SiC SST prototype to verify priority shifting to address controller saturation issue and fast and robust voltage balancing.

14 SOLAR ENERGY↗

DC-Link Current Minimization Control for Current Source Converter-Based Solid-State Transformer

This article proposes a fast predictive control method and a small DC-link inductor to minimize the DC-link current in current-source converter (CSC)-based solid-state transformer. The DC-link current minimization can significantly reduce power loss and improve efficiency. The challenge of this problem is on improving both steady-state and dynamic performance. PI control methods and large DC-link inductors are conventionally used in the CSC but have limited dynamic performance. A model predictive control (MPC) method is proposed to achieve switching-cycle-level settling time, and the DC-link inductor is sized for 40% ripple to enable fast current change. Importantly, this article also proposes to minimize the DC-link current by varying the current even within a line cycle under single-phase load to improve the steady-state performance, in contrast with the reduction to a constant value in the literature. The proposed MPC features a constant switching frequency without weighting factors. The MPC does not have a high computational burden and is implemented in a regular digital controller for a prototype of soft-switching solid-state transformer (S4T) with reduced conduction loss. The effectiveness of the proposed method has been experimentally verified on the SiC S4T prototype during steady-state and dynamics under different multiport power flow conditions up to 2 kV peak. Here, the DC-link current in the experiments is close to the minimum current with a short zero-vector duration, which further verifies the performance of the proposed method.

14 SOLAR ENERGY↗

Grid Ready, Flexible Large Power Transformer

GE Research and its partner Prolec GE have proposed a novel and breakthrough concept to improve the flexibility and interchangeability of large power transformers (LPTs). LPTs refer in this report to transformers with a power rating equal or greater than 100 MVA. The concept consists of a 3-phase autotransformer bank having one specified high voltage side (HV) voltage and three configurable low voltage side (LV) voltage taps. Moreover, the leakage impedance is adjustable offline using taps which allows to accommodate short-circuit requirements for a wide range of LPTs applications. The research performed aimed to develop and validate a cost-effective design of a flexible LPT and to demonstrate its competitiveness with the LPT fleet currently in operation in the U.S. The concept is intended for the long-term replacement of existing LPTs. In this project, the U.S based population of LPTs was analyzed to determine their commonality in power, voltage classes, and impedance range. Up to 9,700 units, currently deployed in the NERC’s Eastern and Western interconnection regions, were evaluated. This analysis yielded the specifications of two flexible LPTs to be designed to demonstrate the manufacturability and competitiveness of the concept: a 345 kV, 230 MVA and a 230 kV, 100 MVA LPTs. The two LPTs are both configurable to 161 kV, 138 kV, and 115 kV on the LV side and allow leakage impedance variation between 4% and 14%. The design output showed that the flexible LPT is manufacturable and competitive with conventional LPT. The proposed design has a power efficiency of 99.5% and a total active part weight increase ranging only between 15% and 28% relative to conventional LPTs it can be substituted with. Indeed, for the flexible LPT, the higher the LV side voltage is, the higher is its power rating. Hence, flexible LPTs are more competitive when compared with the largest conventional LPT they can replace. Power systems analyses were carried out to evaluate the performance of the flexible LPT when replacing an existing conventional LPT. These analyses showed that short-circuit and inrush currents will remain respectively within 15% and 9.4% of their original levels suggesting that no substations equipment is likely to be replaced due the installation of the flexible LPT. In addition, the analyses showed that the transient overvoltage anticipated at the impedance configuration switch will be manageable and will not pose any particular risk during lightning or switching events. This research proved that the deployment of flexible LPTs in the U.S power grid can greatly improve the grid reliability and its resiliency especially in the event of the loss of multiple LPTs. Moreover, the concept can significantly help reduce LPTs’ spare inventory by providing a high spare coverage level. The performed analysis showed that the designed 345 kV flexible LPT can serve as a spare for up to 34 units currently in operation in the U.S while the designed 230 kV flexible LPT can replace up to 101 units. Flexible LPTs offer new opportunities to U.S utilities to improve interchangeability of LPTs in the transmission system and to better strategize the upcoming renewal of about 70% of the population of LPTs anticipated to retire within the next two decades.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Phase Transformation Contributions to Heat Capacity and Impact on Thermal Diffusivity, Thermal Conductivity, and Thermoelectric Performance

Abstract The accurate characterization of thermal conductivity κ, particularly at high temperature, is of paramount importance to many materials, thermoelectrics in particular. The ease and access of thermal diffusivity D measurements allows for the calculation of κ when the volumetric heat capacity, ρc p , of the material is known. However, in the relation κ = ρc p D , there is some confusion as to what value of c p should be used in materials undergoing phase transformations. Herein, it is demonstrated that the Dulong–Petit estimate of c p at high temperature is not appropriate for materials having phase transformations with kinetic timescales relevant to thermal transport. In these materials, there is an additional capacity to store heat in the material through the enthalpy of transformation Δ H . This can be described using a generalized model for the total heat capacity for a material where φ is an order parameter that describes how much latent heat responds “instantly” to temperature changes. Here, C pφ is the intrinsic heat capacity (e.g., approximately the Dulong–Petit heat capacity at high temperature). It is shown experimentally in Zn 4 Sb 3 that the decrease in D through the phase transition at 250 K is fully accounted for by the increase in c p , while κ changes smoothly through the phase transition. Consequently, reports of κ dropping near phase transitions in widely studied materials such as PbTe and SnSe have likely overlooked the effects of excess heat capacity and overestimated the thermoelectric efficiency, zT .

Agne, Matthias T.↗

Understanding Strain‐Induced Phase Transformations in BiFeO 3 Thin Films

Experiments demonstrate that under large epitaxial strain a coexisting striped phase emerges in BiFeO 3 thin films, which comprises a tetragonal‐like ( T ′) and an intermediate S ′ polymorph. It exhibits a relatively large piezoelectric response when switching between the coexisting phase and a uniform T ′ phase. This strain‐induced phase transformation is investigated through a synergistic combination of first‐principles theory and experiments. The results show that the S ′ phase is energetically very close to the T ′ phase, but is structurally similar to the bulk rhombohedral ( R ) phase. By fully characterizing the intermediate S ′ polymorph, it is demonstrated that the flat energy landscape resulting in the absence of an energy barrier between the T ′ and S ′ phases fosters the above‐mentioned reversible phase transformation. This ability to readily transform between the S ′ and T ′ polymorphs, which have very different octahedral rotation patterns and c / a ratios, is crucial to the enhanced piezoelectricity in strained BiFeO 3 films. Additionally, a blueshift in the band gap when moving from R to S ′ to T ′ is observed. These results emphasize the importance of strain engineering for tuning electromechanical responses or, creating unique energy harvesting photonic structures, in oxide thin film architectures.

36 MATERIALS SCIENCE↗