Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “timing detector”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,135 records · Page 63

Detector Performance on Surface Passivation and its Long-Term Stability

Surface passivation is an ideal technique to prepare the surfaces of fabrication Cadmium Zinc Telluride (CZT) and related semiconductor devices such as Cadmium Zinc Tellurium Selenide (CZTS). Surface passivation techniques reduce the effects of aging in the detector [1]. Surface performance effects on material performance can result in fluctuations in energy resolution over time (such as periods of a year or more). The long-term stability of surface passivation with Potassium Hydroxide (KOH) was observed with measurement of 1) current (nano Amp) vs voltage (V) and 2) spectral response and energy resolution throughout the years. Three CZTS detector samples of M2, M3, and M4 were examined using a photomultiplier tube and voltage amplifier. The Bridgman technique is used to grow the CZTS used in this study.

Johnson, Kirsten [Morgan State Univ., Baltimore, M↗

J/ψ production at midrapidity in p-Pb collisions at $ \sqrt{s_{\textrm{NN}}}$ = 8.16 TeV

The production of inclusive, prompt and non-prompt J/ψ was studied for the first time at midrapidity (–1.37 < y cms < 0.43) in p-Pb collisions at $\sqrt{s_{NN}}$ = 8.16 TeV with the ALICE detector at the LHC. The inclusive J/ψ mesons were reconstructed in the dielectron decay channel in the transverse momentum (p T ) interval 0 < p T < 14 GeV/c and the prompt and non-prompt contributions were separated on a statistical basis for p T > 2 GeV/c. The study of the J/ψ mesons in the dielectron channel used for the first time in ALICE online single-electron triggers from the Transition Radiation Detector, providing a data sample corresponding to an integrated luminosity of 689 ± 13 μb –1 . The proton-proton reference cross section for inclusive J/ψ was obtained based on interpolations of measured data at different centre-of-mass energies and a universal function describing the p T -differential J/ψ production cross sections. The p T -differential nuclear modification factors R pPb of inclusive, prompt, and non-prompt J/ψ are consistent with unity and described by theoretical models implementing only nuclear shadowing.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Dark Matter Search Results from 4.2 Tonne−Years of Exposure of the LUX-ZEPLIN (LZ) Experiment

We report results of a search for nuclear recoils induced by weakly interacting massive particle (WIMP) dark matter using the LUX-ZEPLIN (LZ) two-phase xenon time projection chamber. This analysis uses a total exposure of 4.2 ±0.1 tonne-years from 280 live days of LZ operation, of which 3.3 ± 0.1 tonne-years and 220 live days are new. A technique to actively tag background electronic recoils from 214 Pb 𝛽 decays is featured for the first time. Enhanced electron-ion recombination is observed in two-neutrino double electron capture decays of 124 Xe, representing a noteworthy new background. After removal of artificial signal-like events injected into the dataset to mitigate analyzer bias, we find no evidence for an excess over expected backgrounds. World-leading constraints are placed on spin-independent (SI) and spin-dependent WIMP-nucleon cross sections for masses ≥9 GeV/𝑐 2 . The strongest SI exclusion set is 2.2×10 −48 cm 2 at the 90% confidence level and the best SI median sensitivity achieved is 5.1 ×10 −48 cm 2 , both for a mass of 40 GeV/𝑐 2 .

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Flow-dependent tagging of 214 Pb decays in the LZ dark matter detector

The LUX-ZEPLIN (LZ) experiment is searching for dark matter interactions in a liquid xenon time projection chamber (LXe-TPC). This article demonstrates how control of the flow state in the LXe-TPC enables the identification of pairs of sequential alpha-decays, which are used to map fluid flow and ion drift in the liquid target. The resulting transport model is used to tag 214 Pb~ beta-decays, a leading background to dark matter signals in LZ. Temporally evolving volume selections, at a cost of 9.0% of exposure, target the decay of each 214 Pb~ atom up to 81 minutes after production, resulting in (63±6 (s⁢t⁢a⁢t) ±7 (s⁢y⁢s) )% identification of 214 Pb~decays to ground state. We also demonstrate how flow-based tagging techniques enable a novel calibration side band that is concurrent with science data. Lastly we report updated estimates of radon-chain charge branching fractions in liquid xenon, finding branching to 218 Po + at 0.49±0.01, 214 Pb + at 0.48±0.12, and 214 Bi + at 0.74±0.05, with a mean charged ion lifetime in the LZ TPC of 49±4 min.

Lorenzon, Wolfgang [University of Michigan, Ann Ar↗

Short-Lived Intermediate in the N2O Generation by P450 NO Reductase Captured by Time-Resolved IR Spectroscopy and XFEL Crystallography

Diffraction images were collected using an MX300-HS CCD detector. For each cryoloop, 2D raster scan with 50 μm step in each direction was performed twice. In the second pass, the raster-scan grid was shifted 25 μm in each direction. In cheetah directory, - {puck_name}/{pin_id}_hits.h5 correspond to the first scan, and - {puck_name}/{pin_id}-2_hits.h5 correspond to the second scan.

BL3↗

Flow-dependent tagging of $^{214}$Pb decays in the LZ dark matter detector

The LUX-ZEPLIN (LZ) experiment is searching for dark matter interactions in a liquid xenon time projection chamber (LXe-TPC). This article demonstrates how control of the flow state in the LXe-TPC enables the identification of pairs of sequential alpha-decays, which are used to map fluid flow and ion drift in the liquid target. The resulting transport model is used to tag $^{214}$Pb beta-decays, a leading background to dark matter signals in LZ. Temporally evolving volume selections, at a cost of 9.0% of exposure, target the decay of each $^{214}$Pb atom up to 81 minutes after production, resulting in (63 $\pm$ 6$_{\mathrm{stat}}$ $\pm$ 7$_{\mathrm{sys}}$)% identification of $^{214}$Pb decays to ground state. We also demonstrate how flow-based tagging techniques enable a novel calibration side band that is concurrent with science data.

Aalbers, J. [SLAC; Stanford U., Phys. Dept.; KIPAC↗

Electronics for the far-forward CMS muon detector upgrade, ME0

Abstract With the High Luminosity upgrade of the Large Hadron Collider (LHC) we expect increased instantaneous luminosities up to 7.5 × 10 34 cm −2 s −1 , or five times more than the original values. In order to maintain performance of the Compact Muon Solenoid (CMS) experiment under these conditions, ME0 is one of three new muon sub-detectors being added, along with GE1/1 and GE2/1, which use the triple Gas Electron Multiplier (GEM) technology. ME0 is designed to cover the forward region of 2.0 < | η | < 2.8, thus improving muon reconstruction at high background rates by supplementing other overlapping muon subsystems up to | η | = 2.4, while also extending the acceptance for the first time to | η | = 2.8. The readout electronics for ME0 must be designed to accommodate high data rates and be sufficiently radiation hard to operate close to the beamline. The Optohybrid (OH) board for ME0, which reads out data from the front-end VFAT3b ASICs, has therefore been designed to operate without an FPGA (unlike GE1/1 and GE2/1) to ensure radiation hardness. The ME0 OH uses the radiation-hard CERN-designed lpGBT ASIC and VTRx+ optical transceiver module for high bandwidth optical links up to 10.24 Gb/s. The backend system is based on the ATCA standard. The design and development status of the readout electronics for ME0 is presented, along with recent results from integration tests performed using the first prototypes.

Instruments & Instrumentation↗

Design and validation of a gamma-ray scanning system for measuring irradiated nuclear fuel

We report a prototype gamma-ray scanning system was designed to perform post-irradiation measurements of nuclear fuel at Idaho National Laboratory (INL). The system is composed of a coaxial high-purity germanium (HPGe) detector, a collimator, and mechanical positioning stages that translate the fuel sample across the front of the collimator. This paper documents the design process, modeling and the laboratory characterization performed to validate the system. The modeling of the system was done using the Monte Carlo N-Particle code with vendor-supplied design specifications, dimensional measurements, and x-ray radiographs of the HPGe detector. The characterization included measurements of calibrated radiation sources in different geometries, and calculations for absolute efficiency and dead time. Benchmark measurements were performed scanning an irradiated fuel rodlet containing ten pellets of 4.9% enriched UO2 in zirconium alloy. These results were compared to simulated spectra to further help characterize the detector model. One goal of the system is to determine the number of fissions per gram of UO2 in the fuel; comparison of the results from this prototype system's assay of the irradiated fuel rodlet are in agreement with previously estimated results.

98 NUCLEAR DISARMAMENT, SAFEGUARDS, AND PHYSICAL P↗

Superconducting nanowires as high-rate photon detectors in strong magnetic fields

Superconducting nanowire single photon detectors are capable of single-photon detection across a large spectral range, with near unity detection efficiency, picosecond timing jitter, and sub-10 µm position resolution at rates as high as 10 9 counts/s. In an effort to bring this technology into nuclear physics experiments, we fabricate Niobium Nitride nanowire detectors using novel material preparation methods and test their performance in strong magnetic fields. Furthermore, we demonstrate that these devices are capable of detection of 400 nm wavelength photons with saturated internal quantum efficiency at liquid helium temperatures and in magnetic fields potentially up to 8 T at high rates and with nearly zero dark counts.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Predicted performance of a tangential viewing hard x-ray camera for the DIII-D high field side lower hybrid current drive experiment

High field side launch of lower hybrid current drive (LHCD) has improved accessibility and penetration over low field side launch on DIII-D. Simulations predict single pass absorption under a wide range of plasma conditions. Hard x-ray (HXR) measurement of LHCD generated fast electron bremsstrahlung (50–250 keV) will validate wave propagation and absorption. Emissivity profiles are recovered from one-dimensional inversion of HXR brightness to determine LH damping location, fast electron slowing down time, and some indication of the fast electron energy. The camera will be implemented by populating 32 tangential sightlines of the existing Gamma Ray Imager with Kromek SPEARTM Cadmium Zinc Telluride (CZT) detectors sensitive to 10–1000 keV photons with 10 keV energy resolution. Expected count rates allow for <0.5 ms time resolution. Pulses are processed using 50 ns shaping time Cremat CR-200 Gaussian shaping modules and are digitized by 25 MHz D-TACQ ACQ216 digitizers. The performance of the HXR camera is evaluated by comparing predicted fast electron density profiles and inverted synthetic brightnesses obtained from the ray-tracing/Fokker–Planck codes GENRAY/CQL3D. Inversions closely matched predicted fast electron profiles for a range of experimental parameters.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Measurements of Intermediate Species in Fuel-Rich Oxidation of Ethylene, Toluene, and n -Decane

Polycyclic aromatic hydrocarbons (PAHs) are important precursors to the formation of soot and are also pollutant emissions from combustion devices, including internal combustion engines. To understand the formation of PAHs, the low-molecular-weight hydrocarbon chemistry leading to their formation needs to be understood. Toward this goal, fuel-rich oxidation of three different hydrocarbons, i.e., ethylene, toluene, and n-decane, has been investigated in an atmospheric pressure flow reactor at varying temperatures (1000–1350 K), equivalence ratios (φ = 3.0–12.0), and residence times of 0.25–1.5 s. The major C 1 to C 7 intermediates, such as methane, acetylene, ethylene, allene, propyne, propylene, vinylacetylene, 1,3-butadiene, cyclopentadiene, benzene, and toluene, were quantified using a gas chromatograph equipped with a flame ionization detector. The experimental tendency of intermediate species formation, e.g., the dependence of temperature, equivalence ratio, and residence time, was similar in ethylene oxidation and n-decane oxidation. The concentrations of intermediate species up to C 4 were higher in ethylene/n-decane oxidation than toluene oxidation, while a nearly equal or larger amount of C5–C7 species was produced in toluene oxidation. The experimental data were compared with modeling results using a detailed chemical kinetic mechanism. The calculated data using the kinetic model were in agreement with the experimental results. Additionally, a comprehensive kinetic analysis on the reaction pathways of each species was conducted to assess the differences in the oxidation chemistry with the change in the structure of hydrocarbons. In particular, in-depth analysis of benzene formation was performed, elucidating that two benzene formation pathways were important in ethylene and n-decane oxidation: (1) H elimination of the 2,4-cyclohexadienyl radical produced from the isomerization of the 2,4-cyclopentadienylmethyl radical, and (2) dehydrogenation of cyclohexadiene produced from reactions of vinyl radical with 1,3-butadiene. In toluene oxidation, it was found that benzene was primarily produced from toluene through the replacement of the methyl group with hydrogen.

30 DIRECT ENERGY CONVERSION↗

Subcritical Neutron and Gamma Noise Measurements at the Seven Percent Critical Experiment (7uPCX)

As part of a collaborative international effort organized by Lawrence Livermore National Laboratory (LLNL), with key participants from L’Institut de radioprotection et de sûreté nucléaire (IRSN), Los Alamos National Laboratory (LANL), and Sandia National Laboratories (SNL), a series of high-multiplication subcritical neutron and gamma noise measurements were planned and executed. The primary aim of this research was to advance detector technology, assess the validity of gamma noise for subcriticality measurements, and nuclear criticality safety, focusing on collecting list-mode or time-series data from various reactor configurations with multiplication values ranging from 20 to 310. This comprehensive dataset enabled a detailed comparative analysis of multiple detector systems and the results of both neutron and gamma noise measurements. In this work we focus on experimentally comparing the results from neutron and gamma noise measurements. We note good agreement between estimations of the prompt neutron decay constant and demonstrate the effects of changing reactor geometry on the efficiency of the differing methods.

Criticality↗

Experimental Investigation of Subcritical Neutron and Gamma Noise Methods at the Seven Percent Critical Experiment (7uPCX)

As part of a collaborative international effort organized by the Lawrence Livermore National Laboratory (LLNL), with key participants from the Institut de radioprotection et de sûreté nucléaire (IRSN), Los Alamos National Laboratory (LANL), and the Sandia National Laboratories (SNL), a series of high-multiplication subcritical neutron and gamma noise measurements was planned and executed. The primary aim of this article was to advance detector technology, assess the validity of gamma noise for subcriticality measurements, and nuclear criticality safety, focusing on collecting list-mode or time-series data from various reactor configurations with multiplication values ranging from 20 to 310. This comprehensive dataset enabled a detailed comparative analysis of multiple detector systems and the results of both neutron and gamma noise measurements. In this work, we focus on experimentally comparing the results from neutron and gamma noise measurements. We note good agreement between estimations of the prompt neutron decay constant and demonstrate the effects of changing reactor geometry on the efficiency of the differing methods. Our results agree well with independent experimental measurements and simulations performed by LLNL.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Simultaneous determination of CKM angle γ and charm mixing parameters

A combination of measurements sensitive to the CP violation angle γ of the Cabibbo-Kobayashi-Maskawa unitarity triangle and to the charm mixing parameters that describe oscillations between D 0 and $ \overline{D} $ 0 mesons is performed. Results from the charm and beauty sectors, based on data collected with the LHCb detector at CERN’s Large Hadron Collider, are combined for the first time. This method provides an improvement on the precision of the charm mixing parameter y by a factor of two with respect to the current world average. The charm mixing parameters are determined to be $ x=\left({0.400}_{-0.053}^{+0.052}\right)\% $ and y = $ \left({0.630}_{-0.030}^{+0.033}\right)\% $. The angle γ is found to be γ = ($ 65.4_{-4.2}^{+3.8} $)° and is the most precise determination from a single experiment.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Sub-critical assembly die-away analysis with organic scintillators

Determining the reactivity of systems containing fissile material is essential for verifying safety, and possession and enrichment levels. The goal of this experiment was to characterize a subcritical nuclear fuel assembly irradiated by a pulsed neutron generator through differential die-away analysis. Similar characterizations are commonly performed with thermal neutron detectors, but these detectors are bulky and cumbersome, the materials are not widely available, and timing can be clouded by the required thermalization time. In this work, an organic scintillator capable of detecting both neutrons and photons was used to measure the die-away profiles of both particles. These time profiles were then used to estimate the reactivity of the assembly. Here, the calculated reactivity estimates compare favorably to simulated estimates, and therefore provide a useful tool for fissile material characterization.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Simulations and analysis tools for charge-exchange (d, 2 He) reactions in inverse kinematics with the AT-TPC

Charge-exchange (d, 2 He) reactions in inverse kinematics at intermediate energies are a very promising method to investigate the Gamow–Teller transition strength in unstable nuclei. A simulation and analysis software based on the attpcroot package was developed to study this type of reactions with the active-target time projection chamber (AT-TPC). The simulation routines provide a realistic detector response that can be used to understand and benchmark experimental data. Analysis tools and correction routines can be developed and tested from simulations in ATTPCROOT , because they are processed in the same way as the real data. In particular, we study the feasibility of using coincidences with beam-like particles to unambiguously identify the (d, 2 He) reaction channel, and to develop a kinematic fitting routine for future applications. More technically, the impact of space-charge effects in the track reconstruction, and a possible correction method are investigated in detail. Finally, this analysis and simulation package constitutes an essential part of the software development for the fast-beams program with the AT-TPC.

(d,2He)↗

Energy resolution and gain measurements in Argon-based gas mixtures: Exploring Ar:CF 4 for low energy measurements with TPCs

Time Projection Chambers (TPCs) are among the most advanced charged-particle detectors. Gas-filled TPCs have tracking capabilities that provide 3D-imaging of charged particles with a good energy resolution for spectroscopy. Different gas mixtures have different properties that determine the energy resolution as well as the spatial resolution. Therefore, optimization of operating conditions is required to simultaneously obtain adequate gain, energy resolution, spatial/track resolution, as well as higher drift velocities for high counting rates applications. Ar:CF 4 gas mixture has higher electron drift velocities and lower electron diffusion, which makes it an attractive candidate for TPC filling gas for low energy nuclear physics applications as compared to commonly used Ar:CH 4 and Ar:CO 2 gas mixtures, namely when tracking information is needed. However, other properties, including energy resolution and gain, remain largely unexplored in Ar:CF 4 especially at pressures and other operating conditions relevant for low-energy nuclear physics applications. Here, in this paper we report on gain and energy resolution measurements, using Gas Electron Multipliers (GEMs), in the less explored Ar:CF 4 mixture (Alfonsi et al., 2006), as well as in the more commonly used gas mixtures Ar:CH 4 and Ar:CO 2 . In addition to obtaining energy resolution and gain, we provide results from Garfield++ simulations for gain fluctuations, and their impact on energy resolution is discussed.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Why matter effects matter for JUNO

In this paper we focus on the Earth matter effects for the solar parameter determination by a medium baseline reactor experiment such as JUNO. We derive perturbative expansions for the mixing angles θ 12 and θ 13 as well as the Δm$^{2}_{21}$ and Δm$^{2}_{31}$ in terms of the matter potential relevant for JUNO. These expansions, up to second order in the matter potential, while simple, allow one to calculate the electron antineutrino survival probability to a precision much better than needed for the JUNO experiment. We use these perturbative expansions to semi-analytically explain and confirm the shift caused by the matter effects on the solar neutrino mixing parameters θ 12 and Δm$^{2}_{21}$ which were previously obtained by a purely numerical χ 2 analysis. Since these shifts do not satisfy the naive expectations and are significant given the precision that can be achieved by the JUNO experiment, a totally independent cross check using a completely different method is of particular importance. We find that these matter effect shifts do not depend on any of the details of the detector characteristics apart from the baseline and earth mass density between reactor(s) and detector, but do depend on the normalized product of reactor neutrino spectrum times the inverse-beta decay cross-section. The results of this manuscript suggests an alternative analysis method for measuring sin 2 θ 12 and Δm$^{2}_{21}$ in JUNO which would be a useful cross check of the standard analysis and for the understanding of the Wolfenstein matter effect. The explanation of these shifts together with a quantitative understanding, using a semi-analytical method, is the principal purpose of this paper.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗