Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “testing”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,135 records · Page 63

Long-Term Carbon Injection Field Test for 90% Mercury Removal for a PRB Unit a Spray Dryer and Fabric Filter

The power industry in the U.S. is faced with meeting regulations to reduce the emissions of mercury compounds from coal-fired plants. Injecting a sorbent such as powdered activated carbon (PAC) into the flue gas represents one of the simplest and most mature approaches to controlling mercury emissions from coal-fired boilers. The purpose of this test program was to evaluate the long-term mercury removal capability, long-term mercury emissions variability, and operating and maintenance (O&M) costs associated with sorbent injection on a configuration being considered for many new plants. Testing was conducted by ADA Environmental Solutions (ADA) at Rocky Mountain Power’s (RMP) Hardin Station through funding provided by DOE/NETL, RMP, and other industry partners. The Hardin Station is a new plant rated at 121 MW gross that was first brought online in April of 2006. Hardin fires a Powder River Basin (PRB) coal and is configured with selective catalytic reduction (SCR) for NOx control, a spray dryer absorber (SDA) for SO2 control, and a fabric filter (FF) for particulate control. Based upon previous testing at PRB sites with SCRs, very little additional mercury oxidation from the SCR was expected at Hardin. In addition, based upon results from DOE/NETL Phase II Round I testing at Holcomb Station and results from similarly configured sites, low native mercury removal was expected across the SDA and FF. The main goal of this project was met—sorbent injection was used to economically and effectively achieve 90% mercury control as measured from the air heater (AH) outlet to the stack for a period of ten months. This goal was achieved with DARCO® Hg-LH, Calgon FLUEPAC®-MC PLUS and ADA Power PAC PREMIUM brominated activated carbons at nominal loadings of 1.5–2.5 lb/MMacf. An economic analysis determined the twenty-year levelized cost to be 0.87 mills/kW-hr, or $15,000/lb Hg removed. No detrimental effects on other equipment or plant operations were observed. The results of this project also filled a data gap for plants firing PRB coal and configured with an SCR, SDA, and FF, as many new plants are being designed today. Another goal of the project was to evaluate, on a short-term basis, the mercury removal associated with coal additives and coal blending with western bituminous coal. The additive test showed that, at this site, the coal additive known as KNX was affective at increasing mercury removal while decreasing sorbent usage. Coal blending was conducted with two different western bituminous coals, and West Elk coal increased native capture from nominally 10% to 50%. Two additional co-benefits were discovered at this site. First, it was found that native capture increased from nominally 10% at full load to 50% at low load. The effect is believed to be due to an increase in mercury oxidation across the SCR caused by a corresponding decrease in ammonia injection when the plant reduces load. Less ammonia means more active oxidation sites in the SCR for the mercury. The second co-benefit was the finding that high ammonia concentrations can have a negative impact on mercury removal by powdered activated carbon. For a period of time, the plant operated with a high excess of ammonia injection necessitated by the plugging of one-third of the SCR. Under these conditions and at high load, the mercury control system could not maintain 90% removal even at the maximum feed rate of 3.5 lb/MMacf (pounds of mercury per million actual cubic feet). The plant was able to demonstrate that mercury removal was directly related to the ammonia injection rate in a series of tests where the ammonia rate was decreased, causing a corresponding increase in mercury removal. Also, after the SCR was refurbished and ammonia injection levels returned to normal, the mercury removal performance also returned to normal. Another goal of the project was to install a commercial-grade activated carbon injection (ACI) system and integrate it with new-generation continuous emissions monitors for mercury (Hg-CEMs) to allow automatic feedback control on outlet mercury emissions. This was accomplished and the plant can now be operated to control carbon injection based on either the overall mercury removal or an outlet mercury emission rate. By integrating these systems, it was determined that the plant could reduce powdered activated carbon consumption, especially at low load, because, at Hardin, native mercury capture increases from less than 20% to about 50% at low load and the carbon injection rate can be decreased accordingly. Currently, the plant is operating to automatically control emissions to below 0.9 lb/TBtu (pounds of mercury per million British thermal units) at carbon loadings of 0.5 to 1.5 lb/MMacf. During the final phase of the Long-Term test, the ACI system was operated by plant personnel. The estimated O&M cost for a single Hg-CEM system is $15,500/yr. The Hg-CEMs performed well throughout the project. This project began shortly after Thermo Fisher first offered the Mercury Freedom System™ on a commercial basis and progressed though several iterations, improvements, and upgrades to the hardware and software. Indeed, there was a ten-fold increase in the precision and accuracy of the units during the course of the project due to several successful upgrades. In their present condition, the Hg-CEMs measure mercury to a precision of about ± 0.05 μg/wscm (micrograms of mercury per wet standard cubic meter of gas), and only require occasional fine-tuning of the calibration coefficients. The quality assurance/quality control (QA/QC) protocol required to keep the units operating at their optimal performance was also developed and perfected during the course of the project. ADA Environmental Solutions (ADA) developed a daily calibration procedure that surpasses the requirements specified in the Clean Air Mercury Rule (CAMR), and a weekly diagnostic program that ensures that the systems are operating properly and receive the necessary maintenance. For the most part, the systems passed the daily, weekly, and quarterly QA/QC requirements as well as four performance verification tests using the Ontario Hydro (O-H) and Sorbent Trap Methods (STM) for the first test and the EPA Method 30A (M30A) procedure for the remaining three. However, some improvements are still necessary before the system can meet all of the requirements. These involve tests that challenge the system with oxidized mercury (Hg+2). These tests could not be passed at Hardin in spite of trying several improvements suggested by ADA or Thermo Fisher.

20 FOSSIL-FUELED POWER PLANTS↗

Scale-up Testing—Foam as A Remedial Amendment Carrier - 11029

This paper describes results from intermediate-scale, two-dimensional testing of foam injection into sedimentary materials collected from the U.S. Department of Energy (DOE) Hanford Site area. The testing was performed to evaluate the transport of new, more robust, foam generation formulas developed by PNNL on field applicability. The mechanisms of transport , foam stability, delivery pressure, foam migration and the ability of foam to deliver remedial amendments for stabilization of uranium contamination were evaluated. Testing was accomplished in a test bed that is designed to focus on two-dimensional flow, in the form of two, thin rectangular boxes. Each of the boxes holds approximately 135 liters (255 kilograms) of sediment. A total of six sets of tests have been conducted, the last two of which will be described here. During the fifth and sixth tests, foam, generated by means of mechanical blending, was injected into the central screened segment of the left side of each box while air was extracted from multiple screened segments along the right side of each box. During these two tests both of the boxes were loaded to contain a rectangular zones of fine material and a rectangular zone of coarse material . Portions of the sediment were augmented with uranium-rich calcite to produce known concentrations of uranium. The foam generating formulas used in both tests contained sodium phosphate and sodium tripolyphosphate as a remedial amendment. Subsequent to each of the two tests, the test beds were disassembled, and samples of the sediments were taken and analyzed for a number of parameters, depending on the specific test. The data indicated that uranium contamination may be successfully immobilized and that that directional movement of the injected foam can be controlled.

Foam↗

ADAPTATION OF CRACK GROWTH DETECTION TECHNIQUES TO US MATERIAL TEST REACTORS

A key component in evaluating the ability of Light Water Reactors to operate beyond 60 years is characterizing the degradation of materials exposed to radiation and various water chemistries. Of particular concern is the response of reactor materials to Irradiation Assisted Stress Corrosion Cracking (IASCC). Some test reactors outside the United States, such as the Halden Boiling Water Reactor (HBWR), have developed techniques to measure crack growth propagation during irradiation. The basic approach is to use a custom-designed compact loading mechanism to stress the specimen during irradiation, while the crack in the specimen is monitored in-situ using the Direct Current Potential Drop (DCPD) method. In 2012 the US Department of Energy commissioned the Idaho National Laboratory and the MIT Nuclear Reactor Laboratory (MIT NRL) to take the basic concepts developed at the HBWR and adapt them to a test rig capable of conducting in-pile IASCC tests in US Material Test Reactors. The first two and half years of the project consisted of designing and testing the loader mechanism, testing individual components of the in-pile rig and electronic support equipment, and autoclave testing of the rig design prior to insertion in the MIT Reactor. The load was applied to the specimen by means of a scissor like mechanism, actuated by a miniature metal bellows driven by pneumatic pressure and sized to fit within the small in-core irradiation volume. In addition to the loader design, technical challenges included developing robust connections to the specimen for the applied current and voltage measurements, appropriate ceramic insulating materials that can endure the LWR environment, dealing with the high electromagnetic noise environment of a reactor core at full power, and accommodating material property changes in the specimen, due primarily to fast neutron damage, which change the specimen resistance without additional crack growth. The project culminated with an in-pile demonstration at the MIT Reactor. The test rig and associated support equipment were used to apply loads to a representative Compact Tensile specimen during one MITR operating cycle, while measuring crack growth using the DCPD method. Although the test period was short (approximately 70 days), and the accumulated neutron dose relatively small, successful operation of the test rig was demonstrated. The specimen was cycled more than 8000 times (more than would be typical for a long term IASCC test), which was sufficient to propagate a crack of over 2 mm.

Crack Growth↗

AGR-5/6/7 Irradiation Experiment Test Plan

This document presents the test plan for the AGR-5/6/7 irradiation experiment, the combined fifth, sixth, and seventh irradiations of the United States Department of Energy Advanced Gas Reactor (AGR) Fuel Development and Qualification Program. The combined irradiation tests will consist of fuel qualification tests (AGR-5/6) and a margin test (AGR-7) for the industrially produced uranium oxycarbide (UCO) tristructural isotropic (TRISO) coated particle fuel developed by the AGR Program. The objective of the AGR-5/6/7 irradiation experiment is to establish the performance of UCO TRISO fuel fabricated using engineering-scale equipment in a production environment under and beyond normal operating conditions. Specifically, the goals of the AGR 5/6/7 irradiation experiment are: 1. Irradiate reference design fuel containing low-enriched UCO TRISO fuel particles to support fuel qualification. 2. Establish the operating margins for the fuel beyond normal operating conditions. 3. Provide irradiated fuel performance data and irradiated fuel samples for post-irradiation examination and safety testing. 4. Support the refinement of fuel performance and fission product transport models with online, post-irradiation examination and safety test data. In order to achieve the test objectives, the AGR-5/6/7 experiment will be irradiated in the northeast flux trap position of the Advanced Test Reactor at Idaho National Laboratory. The larger diameter of the northeast flux trap provides greater flexibility for test train design, significantly enhancing the capability for the combined irradiations. The test train contains five separate and independently controlled and monitored capsules. The middle capsule contains the AGR 7 margin test fuel. The two bottom and two top capsules contain the AGR 5/6 fuel. Each capsule contains a variable number of fuel compacts filled with UCO TRISO particles.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Destructive Examination of a FeCrAl-UO 2 Irradiation Test

Several destructive postirradiation examinations were performed on an irradiation specimen that coupled an early iron-chromium-aluminum (FeCrAl) candidate alloy cladding with UO2 pellets. This irradiation test was designed to investigate the early life performance and compatibility of the FeCrAl-UO 2 cladding-fuel system under prototypic light water reactor neutronic conditions. Additionally, these tests were expected to provide neutron irradiated samples for severe accident testing of this fuel system. The irradiation studied in this work was part of the ATF-1 series of drop-in style irradiations performed in the Idaho National Laboratory Advanced Test Reactor. The rodlet studied in this work is one of three similar rodlets irradiated in ATF-1 that had approximately 7.6 cm of cladding machined from a wrought FeCrAl alloy and fueled with a 6.1 cm stack of UO 2 pellets. The outer diameter of the cladding was ~0.94 cm and the inner diameter was ~0.83 cm. After irradiation and non-destructive examination in Idaho this rodlet was shipped to the Oak Ridge National Laboratory hot-cells for further examination. The irradiated rodlet was sectioned into several samples for microstructural, micromechanical, and severe accident testing. During sectioning, it was noted that the fuel was not firmly bonded to the cladding and could be readily removed from small cladding slices. Microstructural characterization of fuel cross sections also revealed no significant interaction between the fuel and the cladding. Samples were also prepared for microhardness testing. To prepare for high temperature oxidation testing, the fuel was dissolved from segments of the cladding. High temperature oxidation testing of cladding segments was performed at 1200°C and 1300°C in a steam environment. Comparisons between the oxidation of this FeCrAl alloy in its neutron irradiated state, as-fabricated state, and the oxidation of Zircaloy-2 are made. The oxidation testing will be followed by ring compression testing to evaluate ductility. The microstructure of the samples after oxidation and ring compression testing will also be analyzed.

Harp, Jason↗

Recent Radioactive Material Package Testing Experiences at Oak Ridge National Laboratory

Oak Ridge National Laboratory (ORNL) was a pioneer in the testing of radioactive material shipping packages and has been performing such tests for over 50 years. Currently, except for Type B thermal tests, testing is performed at the purpose-built Packaging Research Facility that is located at the National Transportation Research Center - a U.S. Department of Energy User Facility. Packages used for the transportation of Type B quantities of radioactive materials must be capable of meeting normal conditions of transportation (NCT) requirements and hypothetical accident conditions (HAC) requirements as defined in Title 10 Code of Federal Regulations (CFR) Part 71. Evaluation of package designs to these criteria typically involves a combination of analysis and physical testing. Required physical tests include free drop, crush, puncture, penetration, compression, vibration, water spray, water immersion, and thermal. The Oak Ridge National Laboratory (ORNL) Packaging Evaluation Facility (PEF) at the National Transportation Research Center (NTRC) provides an inclusive testing capability for a wide variety of packages needed for shipment of radioactive materials. Since PATRAM 2019, ORNL has performed several sets of tests including testing of two designs of the Defense Program Package (DPP-3 and DPP-1) and several Special Form Capsules. This paper provides an overview of the testing performed as well as a summary of advancements made to the ORNL package testing program during that time.

Martinez, Oscar↗

Analyses of SPERT-CDC test 859 by FEMAXI-7 and RANNS codes

In the current Japanese regulation concerning fuel safety of water-cooled reactors, the criterion of fuel failure due to pellet-cladding mechanical interaction (PCMI) in a burnup range of 25-40 GWd/t is determined substantially based on the result of SPERT-CDC test 859 (SPERT859). However, there is room for discussion if the result of SPERT859 test rod with a burnup of 31.8 GWd/t represents the failure behavior of the fuel rod for commercial light water reactor because it was reported in some literatures that the cladding of SPERT859 test rod corroded excessively during pre-irradiation. On the other hand, the oxide thickness on the cladding of SPERT859 test rod was not reported in the data of its post-irradiation examinations (PIEs) after pre-irradiation, and the probability of the excessive corrosion on the cladding of the test rod and the effect of such excessive corrosion on the fuel enthalpy at failure of the test rod has not yet been clarified. In this study, the oxide thickness of the cladding formed on the cladding outer surface of SPERT859 test rod and its fuel enthalpy at failure due to PCMI under this corrosion condition were analyzed by using fuel performance codes FEMAXI-7 and RANNS. From the analysis results of FEMAXI-7, it was found that the excessive corrosion of the cladding of the test rod should be assumed to reproduce the fuel outer diameter measured in PIEs after pre-irradiation. The fuel enthalpy at failure of the test rod was calculated by using RANNS, and the calculated fuel enthalpy at failure was relatively close to the value of SPERT859 test rod. These results suggested that the fuel enthalpy at failure of SPERT859 was affected by the excessive corrosion on the cladding of the test rod and was likely lower than that of the typical fuel for light water reactors. (authors)

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Evaluating the Feasibility of Using Strain Measured During Sinusoidal Rate Pumping Tests to Characterize an Aquifer

Pumping tests with sinusoidal variation in pumping rate have been proposed as a method for improving aquifer characterization. These tests can interrogate a larger aquifer volume than slug tests and they can be more sensitive to small variations in drawdown. Current methods of using sinusoidal variations of rate are based on measuring pressure signals from the reservoir or aquifer, which requires access to monitoring wells. An alternative approach has been developed that measures the strain in the vadose zone instead of pressure in the reservoir. An instrument has been developed at Clemson University that can measure small strains using optical fiber sensors, and we propose that it can be used to measure strain during sinusoidal pumping tests. The objective of this project is to evaluate the feasibility of measuring and interpreting the vertical strain in the vadose zone generated during a sinusoidal rate pumping tests to estimate aquifer and/or overburden properties. Pumping tests were performed at a site with a water table at 9 m and saturated saprolite from 9 to 30m depth. Sinusoidal pumping tests in the saprolite used different pumping amplitudes and periods while pressure was measured at three piezometers and vertical strain was measured in the vadose zone from 1 to 7 m depth. The delay time of the pressure increased linearly with distance, and it increased with the square root of the period, while the amplitude of the pressure decreased with distance and increased with amplitude. Vertical strain in the vadose zone varied with the same period as the pumping rate and the delay times were similar to those for pressures measured at similar radial distances. Delay times for the strain increased with an increasing propagation of the strain field. The hydraulic diffusivity was estimated using delay times for pressure and strain, and the results were compared with the values estimated from a constant-rate pumping test. The hydraulic diffusivity from the constant rate test was 0.039 m2/sec, whereas it was 0.053 (±0.05) m2/sec and 0.035 (±0.03) m2/sec from the pressure data and 0.08 (±0.022) m2/sec and 0.035 (±0.001) m2/sec from the strain data from sinusoidal tests of various periods and amplitudes. There is no statistical difference among these values. This study indicates that strain measurements in the vadose zone can be used to estimate aquifer properties during sinusoidal pumping tests.

Blais, Riley↗

A Graphical User Interface for the Deep Underground Neutrino Experiment Robotic Test Stand

In preparation for DUNE, Fermilab along with six other institutions are testing cold electronics for quality control before components placed in the far detector. We test them by using a robotic arm that places these chips into sockets on a computer board that will test their functionality. Up until now, the chips have been tested using a command line script that drives a state machine to conduct tests step-by-step. In order to lower the skill barrier to conduct tests and to speed up the quality control process, I was tasked to create a graphical user interface that would allow users to use buttons, text boxes, and drop-down menus to input information and tell the testing state machine how to operate. I had to learn about the Python package Tkinter to start the process of widget placement. I further developed a pause feature unused in the previous command line script that would allow the user to shut down testing gracefully, bring the robotic arm to go back to ground state, and go forward or backward a step in the testing process. After completing the basic functionality of the GUI, I started testing production chips with the GUI to debug. Some issues were found, which required me to further develop parts of the inherited state machine code. The code for the GUI has now been pushed into the copy the DUNE/FD_CE git repository and will soon be merged with the official DUNE/FD_CE repository so that the other institutions testing DUNE cold electronics can use and expand upon it.

Gutierrez Villanueva, Jaziel [Fermilab]↗

DEVELOPMENT OF BURN TEST SPECIFICATIONS FOR FIRE PROTECTION MATERIALS IN RAM PACKAGES

The regulations in 10 CFR 71 require that the radioactive material (RAM) packages must be able to withstand specific fire conditions given in 10 CFR 71.73 during Hypothetical Accident Conditions (HAC). This requirement is normally satisfied by extensive testing of full scale test specimens under required test conditions. Since fire test planning and execution is expensive and only provides a single snapshot into a package performance, every effort is made to minimize testing and supplement tests with results from computational thermal models. However, the accuracy of such thermal models depends heavily on the thermal properties of the fire insulating materials that are rarely available at the regulatory fire temperatures. To the best of authors knowledge no test standards exist that could be used to test the insulating materials and derive their thermal properties for the RAM package design. This paper presents a review of the existing industry fire testing standards and proposes testing methods that could serve as a standardized specification for testing fire insulating materials for use in RAM packages.

42 ENGINEERING↗

ORNL Interim Progress Report on Hydride Reorientation CIRFT Tests

A systematic study of H. B. Robinson (HBR) high burnup spent nuclear fuel (SNF) vibration integrity was performed in Phase I project under simulated transportation environments, using the Cyclic Integrated Reversible-Bending Fatigue Tester (CIRFT) hot cell testing technology developed at Oak Ridge National Laboratory in 2013–14. The data analysis on the as-irradiated HBR SNF rods demonstrated that the load amplitude is the dominant factor that controls the fatigue life of bending rods. However, previous studies have shown that the hydrogen content and hydride morphology has an important effect on zirconium alloy mechanical properties. To address the effect of radial hydrides in SNF rods, in Phase II a test procedure was developed to simulate the effects of elevated temperatures, pressures, and stresses during transfer-drying operations. Pressurized and sealed fuel segments were heated to the target temperature for a preset hold time and slow-cooled at a controlled rate. The procedure was applied to both non-irradiated/prehydrided and high-burnup Zircaloy-4 fueled cladding segments using the Nuclear Regulatory Commission-recommended 400°C maximum temperature limit at various cooling rates. Before testing high-burnup cladding, four out-of-cell tests were conducted to optimize the hydride reorientation (R) test condition with pre-hydride Zircaloy-4 cladding, which has the same geometry as the high burnup fuel samples. Test HR-HBR#1 was conducted at the maximum hoop stress of 145 MPa, at a 400°C maximum temperature and a 5°C/h cooling rate. On the other hand, thermal cycling was performed for tests HR-HBR#2, HR-HBR#3, and HR-HBR#4 to generate more radial hydrides. It is clear that thermal cycling increases the ratio of the radial hydride to circumferential hydrides. The internal pressure also has a significant effect on the radial hydride morphology. This report describes a procedure and experimental results of the four out-of-cell hydride reorientation tests of hydrided Zircaloy-4 cladding, which served as a guideline to prepare in-cell hydride reorientation samples with high burnup HBR fuel segments. This report also provides the Phase II CIRFT test data for the hydride reorientation irradiated samples. The variations in fatigue life are provided in terms of moment, equivalent stress, curvature, and equivalent strain for the tested SNFs. The CIRFT results appear to indicate that hydride reoriented treatment (HRT) have a negative effect on fatigue life, in addition to hydride reorientation effect. For HR4 specimen that had no pressurization procedure applied, the thermal annealing treatment alone showed a negative impact on the fatigue life compared to the HBR rod.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

REALIZATION OF A AUTOMATED T-WAY COMBINATORIAL TESTING APPROACH FOR A SOFTWARE BASED EMBEDDED DIGITAL DEVICE

Under the Department of Energy’s Light Water Reactor Sustainability Program, within the Plant Modernization research pathway, the Digital I&C Qualification Project is identifying new methods that would be beneficial in qualifying digital I&C systems and devices for safety-related usage. One such method that would be useful in qualifying field components such as sensors and actuators is the concept of testability. The Nuclear Regulatory Commission (NRC) considers testability to be one of two design attributes sufficient to eliminate consideration of software-based or software logic-based common cause failure (the other being diversity). The NRC defines acceptable “testability” as follows: Testability – A system is sufficiently simple such that every possible combination of inputs and every possible sequence of device states are tested and all outputs are verified for every case (100% tested). [NUREG 0800, Chapter 7, Branch Technical Position (BTP) 7-19] This qualification method has never proven to be practical in view of the very large number of combinations of inputs and sequences of device states for a typical I&C device. However, many of these combinations are not unique in the sense that they represent the same state space or in that that they represent state space that would not affect the critical design basis functions of the device. Therefore, the state space of interest might possibly be reduced to a manageable dimension through such analysis. This project will focus on a representative I&C device similar in design, function, and complexity to the types of devices that would likely be deployed in nuclear power plants as digital or software based sensors and actuators (e.g. Smart Sensors). Analysis will be conducted to determine the feasibility of testing this device in a manner consistent with the NRC definition. This report describes the development of test process for Bounded Exhaustive Testing with respect to Combinatorial Test (CT) methods. The report describes the candidate Device Under Test SW – the VCU smart sensor, conceptual experimental methods for stated test objectives, description of the process, tools, resources, and computing. This information will be used to fully develop a detailed test plan (based on statistical measure needs) and test environment for conducting an I&C device testability demonstration study. The future planed experimental study of this project is to demonstrate digital qualification via Bounded Exhaustive Testability with respect to Common Cause Failure.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Future Transient Testing of Advanced Fuels

The transient in-reactor fuels testing workshop was held on May 4–5, 2009 at Idaho National Laboratory. The purpose of this meeting was to provide a forum where technical experts in transient testing of nuclear fuels could meet directly with technical instrumentation experts and nuclear fuel modeling and simulation experts to discuss needed advancements in transient testing to support a basic understanding of nuclear fuel behavior under off-normal conditions. The workshop was attended by representatives from Commissariat à l'Énergie Atomique CEA, Japanese Atomic Energy Agency (JAEA), Department of Energy (DOE), AREVA, General Electric – Global Nuclear Fuels (GE-GNF), Westinghouse, Electric Power Research Institute (EPRI), universities, and several DOE national laboratories. Transient testing of fuels and materials generates information required for advanced fuels in future nuclear power plants. Future nuclear power plants will rely heavily on advanced computer modeling and simulation that describes fuel behavior under off-normal conditions. TREAT is an ideal facility for this testing because of its flexibility, proven operation and material condition. The opportunity exists to develop advanced instrumentation and data collection that can support modeling and simulation needs much better than was possible in the past. In order to take advantage of these opportunities, test programs must be carefully designed to yield basic information to support modeling before conducting integral performance tests. An early start of TREAT and operation at low power would provide significant dividends in training, development of instrumentation, and checkout of reactor systems. Early start of TREAT (2015) is needed to support the requirements of potential users of TREAT and include the testing of full length fuel irradiated in the FFTF reactor. The capabilities provided by TREAT are needed for the development of nuclear power and the following benefits will be realized by the refurbishment and restart of TREAT. •TREAT is an absolute necessity in the suite of reactor fuel test capabilities •TREAT yields valuable information on reactivity effects, margins to failure, fuel dispersal, and failure propagation •Most importantly, interpretation of TREAT experiment results is a stringent test of the integrated understanding of fuel performance.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Development and Testing of Techniques for In-Ground Stabilization, Size Reduction and Safe Removal of Radioactive Wastes Stored in Large Containments in Burial Grounds - 13591

Radioactive waste materials, including Transuranic (TRU) wastes from laboratories have been stored below ground in large containments at a number of sites in the US DOE Complex, and at nuclear sites in Europe. These containments are generally referred to as caissons or shafts. The containments are in a range of sizes and depths below grade. The caissons at the DOE's Hanford site are cylindrical, of the order of 2,500 mm in diameter, 3,050 mm in height and are buried about 6,000 mm below grade. One type of caisson is made out of corrugated pipe, whereas others are made of concrete with standard re-bar. However, the larger shafts in the UK are of the order of 4,600 mm in diameter, 53,500 mm deep, and 12,000 below grade. This paper describes the R and D work and testing activities performed to date to evaluate the concept of in-ground size reduction and stabilization of the contents of large containments similar to those at Hanford. In practice, the height of the Test Facility provided for a test cell that was approximately 22' deep. That prevented a 'full scale mockup' test in the sense that the Hanford Caisson configuration would be an identical replication. Therefore, the project was conducted in two phases. The first phase tested a simulated Caisson with surrogate contents, and part of a Chute section, and the second phase tested a full chute section. These tests were performed at VJ Technologies Test Facility located in East Haven, CT, as part of the Proof of Design Concept program for studying the feasibility of an in-situ grout/grind/mix/stabilize technology for the remediation of four caissons at the 618-11 Burial Ground at US Department of Energy Hanford Site. The test site was constructed such that multiple testing areas were provided for the evaluation of various tools, equipment and procedures under conditions that simulated the Hanford site, with representative soils and layout dimensions. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

CHARACTERIZATION OF RADIOACTIVITY IN THE REACTOR VESSEL OF THE HEAVY WATER COMPONENT TEST REACTOR

The Heavy Water Component Test Reactor (HWCTR) facility is a pressurized heavy water reactor that was used to test candidate fuel designs for heavy water power reactors. The reactor operated at nominal power of 50 MW{sub th}. The reactor coolant loop operated at 1200 psig and 250 C. Two isolated test loop were designed into the reactor to provide special test conditions. Fig. 1 shows a cut-away view of the reactor. The two loops are contained in four inch diameter stainless steel piping. The HWCTR was operated for only a short duration, from March 1962 to December 1964 in order to test the viability of test fuel elements and other reactor components for use in a heavy water power reactor. The reactor achieved 13,882 MWd of total power while testing 36 different fuel assemblies. In the course of operation, HWCTR experienced the cladding failures of 10 separate test fuel assemblies. In each case, the cladding was breached with some release of fuel core material into the isolated test loop, causing fission product and actinide contamination in the main coolant loop and the liquid and boiling test loops. Despite the contribution of the contamination from the failed fuel, the primary source of radioactivity in the HWCTR vessel and internals is the activation products in the thermal shields, and to a lesser degree, activation products in the reactor vessel walls and liner. A detailed facility characterization report of the HWCTR facility was completed in 1996. Many of the inputs and assumptions in the 1996 characterization report were derived from the HWCTR decommissioning plan published in 1975. The current paper provides an updated assessment of the radioisotopic characteristics of the HWCTR vessel and internals to support decommissioning activities on the facility.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Feasibility study for test rig assessments of fish passage conditions in a Kaplan turbine

The assessment of fish passage conditions in hydroelectric turbines consists of identifying and quantifying physical magnitudes leading to increased risks of injury of fish passing through turbines in operation. Such assessments are usually carried out either with the use of computer-based methods during design or with field testing of live fish and sensors passing through prototypes. A method in between consists of test rig experimentation, which is critical for testing fish-focused design concepts and offers the opportunity for implementing the most effective design measures for improved fish survivability. However, fish-related assessments in test rigs are not sufficiently documented for industrial applications. This work presents the main findings of an experimental campaign to quantify fish-related hydraulic magnitudes in a physical model of a Kaplan turbine in a commercial test rig. Two operating conditions were tested by releasing miniaturized autonomous sensor devices (termed Sensor Fish Mini) at the turbine intake flow, passing them through the runner in motion and recovering them at the draft tube exit. During passage, time series of acceleration, absolute pressure and rotational velocity were recorded. The recordings were then interpreted to determine the magnitude and likely location of hydraulic stressors hazardous to fish. The statistical tests on the reported measurements indicated that low pressure, collisions on the runner and rotations in the draft tube were not different between the two tested operating points. On the other hand, pressure drop and collision rates on the distributor differed considerably as a function of net head. The outcomes of this investigation showed that test rig evaluations of fish-related properties with Sensor Fish Mini can contribute to an evidence-based development of turbine geometries designed for providing safer passage conditions. Future work will investigate the scaling of test rig measurements to hydraulically equivalent magnitudes in the prototype and their biological consequences.

13 HYDRO ENERGY↗

Testing at scale during the COVID-19 pandemic

Assembly and publication of the severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2) genome in January 2020 enabled the immediate development of tests to detect the new virus. This began the largest global testing programme in history, in which hundreds of millions of individuals have been tested to date. The unprecedented scale of testing has driven innovation in the strategies, technologies and concepts that govern testing in public health. In this Review, we describe the changing role of testing during the COVID-19 pandemic, including the use of genomic surveillance to track SARS-CoV-2 transmission around the world, the use of contact tracing to contain disease outbreaks and testing for the presence of the virus circulating in the environment. Despite these efforts, widespread community transmission has become entrenched in many countries and has required the testing of populations to identify and isolate infected individuals, many of whom are asymptomatic. The diagnostic and epidemiological principles that underpin such population-scale testing are also considered, as are the high-throughput and point-of-care technologies that make testing feasible on a massive scale.

60 APPLIED LIFE SCIENCES↗

Uranium Adsorption on Ion-Exchange Resins - Batch Testing

The uranium adsorption performance of five resins (Dowex 1, Dowex 21K 16-30 [fresh], Dowex 21K 16-30 [regenerated], Purofine PFA600/4740, and ResinTech SIR-1200) were tested using unspiked, nitrate-spiked, and nitrate-spiked/pH adjusted source water from well 299-W19-36. These batch tests were conducted in support of a resin selection process in which the best resin to use for uranium treatment in the 200-West Area groundwater pump-and-treat system will be identified. The results from these tests are as follows: • The data from the high-nitrate (1331 mg/L) tests indicated that Dowex 1, Dowex 21K 16-30 (fresh), Purofine PFA600/4740, and ResinTech SIR-1200 all adsorbed uranium similarly well with Kd values ranging from ~15,000 to 95,000 ml/g. All four resins would be considered suitable for use in the treatment system based on uranium adsorption characteristics. • Lowering the pH of the high nitrate test conditions from 8.2 to 7.5 did not significantly change the uranium adsorption isotherms for the four tested resins. The Kd values for these four resins under high nitrate (1338 mg/L), lower pH (7.5) ranged from ~15,000 to 80,000 ml/g. • Higher nitrate concentrations greatly reduced the uranium adsorption on all four resins. Tests conducted with unspiked (no amendments; nitrate at 337 mg/L and pH at 8.2) source water yielded Kd values for Dowex 1, Dowex 21K 16-30 (fresh), Purofine PFA600/4740, and ResinTech SIR-1200 resins ranging from ~800,000 to >3,000,000 ml/g. These values are about two orders of magnitude higher than the Kd values noted from tests conducted using amended source water. • Compared to the fresh resin, the regenerated Dowex 21K 16-30 resin exhibited significantly lower uranium-adsorption performance under all test conditions. The calculated Kd values for the regenerated resin were typically an order of magnitude lower than the values calculated for the fresh resin. • Additional testing using laboratory columns is recommended to better resolve differences between the adsorption abilities of the resins and to develop estimates of uranium loading on the resins. By determining the quantity of uranium that each resin can adsorb and the time required to reach various levels of loading, resin lifetime in the treatment system can be estimated.

36 MATERIALS SCIENCE↗