Using Calorimetry Techniques to Investigate the Effects of Dwell Time and Thermal Aging on Polymer Crystallization During Laser-Based Powder Bed Fusion
Explore the source record for details and available documents.
SEARCH · Engineering Papers
Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.
Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.
Explore the source record for details and available documents.
Explore the source record for details and available documents.
Explore the source record for details and available documents.
Explore the source record for details and available documents.
Dielectric heating was explored as a means of calcining gypsum to produce stucco, the wallboard precursor, with lower water demand and therefore lower drying energy.
Presentation at PPPS 2025, Berlin, Germany
Explore the source record for details and available documents.
Explore the source record for details and available documents.
Simulation of cable system response to frequency domain reflectometry (FDR) tests can be instrumental to understanding these tests and the nature and influence of various cable anomalies on test signatures. Reflectometry simulations are based upon a finite element representation of cable conductors and insulation to produce an S-parameter at each evaluated frequency. The aggregate collection of cable model S-parameters can simulate the influence on a test signal injected into a physical cable. Such an approach was undertaken in this work to produce a digital twin simulation of a low-voltage electrical cable. The electrical cable digital twin examined the influence of test simulation parameters and the relative influence of cable anomalies, including thermal aging, water or moisture exposure, water or moisture ingress, and other anomalies. The digital twin in this work included modeling of the conductors, insulation, jacket, and surrounding environment (air, water, etc.). The digital twin could be expanded to include cable bends, junctions and splices, branch or T systems, and termination impedances of motors or instruments. Observations and conclusions of this work include: 1. Fully 3D digital twin simulation of an electrical cable using an FDR approach is possible. However, there are tradeoffs between simulation fidelity and solution time, which must be balanced to ensure the simulation solves in an adequate amount of time (e.g., less than 20 minutes). Simulation parameters to balance include frequency bandwidth, number of frequencies, mesh density, connection impedance, and permittivity tolerance. 2. The digital twin simulation can explain FDR sensitivity to various cable anomalies, including entry and exit from an oven or water bath. 3. The digital twin simulation FDR response attenuates with distance along the cable and is further affected by the frequency bandwidth, which is similar to that observed with physical measurements. 4. The resolution of the digital twin FDR peaks increased with increasing bandwidth and with increasing number of frequencies, again similar to physical measurements. 5. The presence of multiple anomalies in the digital twin does not substantially attenuate the FDR response to anomalies located beyond the first encountered anomaly and impedance mismatch. 6. Spectral variation of the permittivity did not have a significant effect on the FDR response compared to a fixed nominal value. 7. Extension of the digital twin to 1000 ft still allowed for detection of distal anomalies near the far end of the electrical cable from the instrument connection point. 8. The ARENA test bed facilitates efficient NDE evaluations of well understood cable anomalies with various NDE methods without risking actual plant damage.
Explore the source record for details and available documents.
Explore the source record for details and available documents.
Explore the source record for details and available documents.
Explore the source record for details and available documents.
Explore the source record for details and available documents.
Geothermal energy development requires downhole tools that operate reliably at temperatures up to 320 °C. While MWD tools work without thermal protection and logging tools use vacuum flasks for limited high-temperature use, Sandia National Laboratories is developing durable electronics on ceramic PCBs with protective coatings to enable long-term operation of geothermal instruments at sustained temperatures up to 300 °C.
Rare earth elements (REEs), as critical minerals, have important uses in modern energy and technologies, yet are vulnerable to potential supply chain disruptions. To establish domestic REE supply chain, efficient REE detection methods for resource characterization and mineral processing will be needed to accelerate innovations for domestic REE recovery. This study developed a rapid, novel, and cost-effective for REE detection method using ion chromatography (IC) for aqueous samples. Various REE-targeted eluent gradients and post-column agent compositions were tested on the chelation ion chromatography (CIC) with UV-vis detector for optimal separation and quantification of REEs within approximately 20 min. The single-channel pump to deliver the post-column solution to UV-vis detector was replaced with a 4-channel gradient pump, to increase operation and maintenance efficiencies. After method optimization, resulting calibration curves for more than ten REEs achieved high coefficients of determination (R2>0.999) and low relatively standard deviations (below 3.24%), demonstrating sub-ppm level detection limits (0.0897 to 0.1149 mg/L). The reliability of the CIC method was validated through comparison with inductively coupled plasma mass spectrometry (ICP-MS), showing strong agreement in REE recovery from certified standards. The impact of metal ions and salts on REE recovery using CIC was also systematically investigated. CIC consistently exhibited reliable performance in the presence of salt solutions such as NaCl and Na₂SO₄ (up to 10,000 mg/L). Our study also found the presence of high concentrations of Al ions (at 10,000 mg/L) significantly influenced REE determination, and elevated concentrations of Ca ions affected the recovery of specific REEs, including La, Ce, and Pr. The CIC method was further tested on REE-containing eluents from solvent extraction tests out of fly ash leachates. REE detection from these real processing fluids were reported to achieve 90% to 100% recovery rate from our IC method, compared to ICP-MS results. This study underscores the potential of CIC as a reliable and efficient alternative for REE determination in complex matrices. It also highlights the importance of minimizing select interfering metal ions in solutions to ensure accurate results. The REE CIC method presents a promising, low-maintenance, salt-tolerant, and cost-effective alternative to traditional analytical methods for REE analysis.
Explore the source record for details and available documents.
Explore the source record for details and available documents.