Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “system analysis”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,135 records · Page 63

Assessment of Nuclear Energy to Support Negative Emission Technologies

The feasibility and performance of nuclear energy coupled with Negative Emission Technology (NET) processes were investigated in this report. Three overarching questions from nuclear NET systems guided this research: which NET would be able to use heat and/or electricity from nuclear power plants (NPPs); what is the performance and cost of a nuclear NET system; and what would be the market outlook for this system? Among the various NETs that are actively being developed, several were found to potentially benefit from coupling with an NPP via (1) large amounts of decarbonized and constant-output electricity; (2) free waste heat or cheap low-temperature heat; or (3) high-temperature heat. NPPs were found to be compatible with Direct Air Capture (DAC) systems, and a detailed techno-economic analysis of coupled NPP&DAC systems was performed. Preliminary analysis also indicated that biomass and water-based NETs are potentially compatible with NPPs, but further work is needed to quantify the performance of these nuclear NET systems. Design and performance analyses were completed for both liquid solvent DAC (L-DAC) and solid sorbent DAC (S-DAC) technologies. A 1.0-GWth NPP coupled with L-DAC and S-DAC was found to be able to capture 12–15 Mt CO 2 /yr and 1.0–1.5 Mt CO 2 /yr, respectively. While the L-DAC process enables much greater CO 2 capture than the S-DAC process when both are sized with a 1 GWth NPP, the NPP&L-DAC system considered also requires >2 GWth natural gas oxy-combustion to reach adequate temperature in the calciner. CO 2 generated from natural gas combustion is also captured as part of the calcination process, in addition to the CO 2 captured from air, resulting in overall CO 2 sequestration of close to 30% more than what is captured from air. The cost of carbon capture calculated with the levelized cost of DAC (LCOD) had a range of $\$170–260$/tCO 2 for NPP&L-DAC systems and a range of $\$650–680$/tCO 2 for NPP&S-DAC systems. For both DAC systems, the NPP provides economic benefit when compared to previous National Energy Technology Laboratory (NETL) studies of non-nuclear DAC systems, leading to reduction of LCOD by 5–7% for L-DAC, and 8–13% for S-DAC. For the NPP&DAC systems, a preliminary market analysis reviewed potential CO 2 market prices and eligibility for incentives. The estimated potential revenues for CO 2 capture (coming from federal incentive, CO 2 commodity markets, or offset market) is in the range of $\$170–979$ tCO 2 , and the results show that because of lower LCOD, the NPP&L-DAC process would be more attractive to a market than the NPP&S-DAC process. The large investment needed for NPP&DAC processes would require long-term certainty of sufficient market size, CO 2 prices, and incentives. Enabling NPPs to ramp DAC operation up or down based on electricity market price is not expected to significantly increase revenues of the NPP&DAC system. This is because the revenues from CO 2 sequestration are required to be very high to justify the deployment and continuous operation of the very expensive DAC technologies. In this analysis, several new research questions were uncovered, and follow-up analyses are recommended for further investigation, including a detailed feasibility study of NPP coupled with other NET systems such as biomass pyrolysis and gasification with carbon capture and storage, and seawater carbon capture.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Mooring System Cost Estimates for Wave Energy Farms in Shared Mooring Arrays

As wave energy converters (WECs) become more advanced and cost-efficient, so too must their mooring systems. A key question in the development plans for WECs is the cost of the mooring system, particularly for large wave farms. WEC devices deployed in a WEC farm array, where each device can be connected by shared mooring lines in various array layouts, have potential to reduce mooring system costs significantly. This paper presents the modeling and designing of mooring systems for large WEC arrays and the calculation of the cost of each mooring system to determine the change in cost as the number of WECs in a farm increases. A baseline mooring system for a single floating oscillating water column (OWC) WEC was developed for this analysis. The mooring system utilizes four anchored mooring lines connected to a square assembly of wire rope mooring lines, supported by four floating buoys, and attached to the floating WEC by four polyester rope mooring lines. This assembly, referred to as a floating cell, can be tiled to form various rectangular WEC arrays. The objective of this analysis is to determine how the mooring system cost changes as more WECs are added to an array layout, each with their own interconnected floating cell. To do this, complete mooring systems need to be designed for each WEC array layout. To narrow down the design space of a WEC array mooring system, a couple assumptions were made. It was assumed that the floating cell parameters of the baseline design were to stay constant across all floating cells in the WEC array. It was also assumed that the anchored mooring lines would be of the baseline configuration, a predominantly chain mooring line with a short section of polyester rope near the fairlead, and a drag-embedment anchor. These anchored lines were assumed to extend from the outer edges of the WEC array, inline with the headings of the wire rope mooring lines of the floating cells, or diagonal if extending from a corner of the WEC array. Full mooring systems were designed for 2xN and NxN WEC array layouts and efficiently simulated in the mooring dynamics simulation tool, MoorDyn, to ensure all dynamic constraints were met. The system costs were calculated and then refined by shortening unnecessary chain line lengths and reducing the chain diameters of the downstream anchored mooring lines. It was found that, in general, mooring system costs per WEC decrease when WECs are installed in an array. Compared to the baseline mooring system for a single WEC, the 2x3 mooring system array had the lowest mooring system cost per WEC, reducing the cost per WEC by 59%. The 3x3 and 4x4 array mooring systems also saw significant reductions in cost per WEC but had negligible cost savings between the two designs, primarily because the larger 4x4 mooring system requires larger chain diameters, which increases cost. These results provide an interesting glimpse into modeling, designing, and calculating the cost of mooring systems for large WEC arrays.

cost↗

An Online Tool for Preliminary Design and Techno-Economic Analysis of District Geothermal Heating and Cooling Systems

District geothermal heating and cooling systems (DGHCS) have significant benefits for reducing energy consumption as well as building- and grid-level peak electric demand. Currently, no publicly available tools are available to effectively design and conduct techno-economic analysis of DGHCS. GeoWISE was originally developed for preliminary design and techno-economic analysis of geothermal heating and cooling systems in an individual commercial or residential building. This paper introduces recent upgrades of GeoWISE that allow users to design and conduct techno-economic analysis of DGHCS. Several new features are implemented in GeoWISE to allow selection and specification of multiple new or existing buildings. A database of information for over 125 million existing U.S. buildings was used in GeoWISE that allows users easily locate existing buildings of interest based on street addresses, and optionally edit information of the buildings (e.g., footprint, vintage, principal functions, number of floors, window-to-wall ratio). Unique energy simulation models of the selected buildings are then automatically created using the Automatic Building Energy Modeling (AutoBEM) and EnergyPlus simulations are performed to predict thermal loads of the buildings. A simplified DGHCS is then designed and simulated to predict its energy use. A central borehole heat exchanger (BHE) of the DGHCS is sized using the RowWise algorithm of GHEDesigner to meet the thermal loads within user-specified land areas for installing BHE. The upgraded GeoWISE reports the needed capacity of heating and cooling equipment in each building, design of the central BHE, energy consumption reduction, and energy cost saving resulting from using DGHCS compared with conventional HVAC systems. A case study is showcased using the upgraded GeoWISE to design and conduct techno-economic analysis of a simplified DGHCS.

Prem Anand Jayaprabha, Jyothis Anand [ORNL] (ORCID↗

Ultra-Long Distance BOTDA Sensor System Employing Hybrid Amplification and Advanced Noise Reduction Techniques

Brillouin Optical Time Domain Analysis (BOTDA) sensor system play a pivotal role in distributed sensing, which enables precise measurements of strain and temperature across extensive fiber lengths. Nonetheless, challenges emerge as distances grow due to signal attenuation and noise interference resulting in measurement errors. This research offers a comprehensive strategy to extend the sensing range of BOTDA systems beyond 10’s of kilometers while maintaining high spatial resolutions. Such enhanced sensing is realized through the integration of distributed Raman amplification, inline amplification using erbium-doped fiber amplifiers (EDFA), and advanced noise reduction techniques. Leveraging inherent redundancy in measured data as a function of frequency and fiber distance, the non-local means (NLM) filter removes noise while preserving essential physical information. This approach proves particularly advantageous in BOTDA systems, where accurate measurement of Brillouin scattering signals is paramount for long-range sensing, while concurrently safeguarding high spatial resolutions. In summary, this research has shown a holistic exploration of extending BOTDA's distance sensing capabilities up to 150 km with spatial resolutions of 8 meters.

Bhatta, Hari↗

Ultra-Long Distance BOTDA Sensor System Employing Hybrid Amplification and Advanced Noise Reduction Techniques

Brillouin Optical Time Domain Analysis (BOTDA) sensor systems play a pivotal role in distributed sensing, which enables precise measurements of strain and temperature across extensive fiber lengths. This research offers a comprehensive strategy to extend the sensing range of BOTDA systems beyond tens of kilometers while maintaining high spatial resolutions. Such enhanced sensing is realized through the integration of distributed Raman amplification, inline amplification using erbium-doped fiber amplifiers (EDFA), and advanced noise reduction techniques. Optimizing Raman pump and probe wave profiles ensures the robustness of Brillouin scattering signals, effectively countering attenuation-induced losses. Additionally, enhancing weak Brillouin signals by strategically placing EDFAs at optimal fiber locations keeps sensor sensitivity high. Leveraging inherent redundancy in measured data as a function of frequency and fiber distance, the non-local means (NLM) filter removes noise while preserving essential physical information. In summary, this research has shown a holistic exploration of extending BOTDA’s distance sensing capabilities up to 150 km with spatial resolutions of 8 meters.

Bhatta, Hari↗

System Modeling and Robust Stability Region Analysis for Multi-inverters Based on VSG

As the number of inverter-interfaced distributed generators (IIDGs) increases, the decrease in the inertia of the microgrid affects the stability of microgrid voltage and current. The virtual synchronous generator (VSG) control method simulates the output characteristics of the synchronous machine to improve the inertia and damping of the microgrid. However, low-frequency oscillations can occur in systems with multi-VSGs connected in parallel, primarily when operating in island mode. Therefore, this article develops the small-signal state-space model for multi-inverters based on VSG and analyses the robust stability region (RSR) of the control parameters. Firstly, an extensible small-signal state-space model is established and simplified in the dq axis, which is a necessary preprocessing for the subsequent stability analysis. Secondly, the guardian map method based on bialternate product operation is constructed, and the RSR is established through translation mapping and rotation mapping. Therefore, the solution of RSR is transformed into the problem of identifying the Hurwitz matrix. Finally, the simulations and experiments verify that the calculated region can ensure stable operation during startup and meet the requirement to suppress low-frequency oscillations. In conclusion, the method of solving RSR proposed in this paper provides a basis for selecting controller parameters in practical engineering.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Spent nuclear fuel receipt rate analysis within an integrated waste management system (IWMS) architecture that includes consolidated storage

A key parameter in analyzing the performance of an integrated waste management system (IWMS) architecture for the disposition of spent nuclear fuel (SNF) is the SNF receipt rate from reactor and other custodian sites. Receipt rate in this paper means how much SNF is accepted per year for transport in the IWMS from such sites. Introducing one or more federal consolidated interim storage facilities (CISFs) into the IWMS architecture can potentially accelerate the receipt rate profile over time relative to system architectures without a CISF. This raises the question of what an optimal SNF receipt rate profile for an IWMS architecture might be in view of practical constraints and desired system performance attributes and associated metrics. This paper describes a sensitivity study on SNF receipt rates and the associated results for a selected set of IWMS scenarios aimed at informing near-term planning for interim storage capabilities and transportation assets. Two different strategies for CISF operation while awaiting availability of a disposal system to receive SNF are compared: one that relatively quickly fills an initial CISF and then idles the transportation system; and another that aims for more continuous use of transportation assets and receipt capabilities at the CISF. This study examines cost considerations and other factors, such as the timing of clearing reactor sites of SNF, efficient use of capital assets, and some other metrics that might be important to a CISF host community. Based on the analysis, an initial approach is presented that targets a continuous receipt strategy while maintaining the flexibility to step up receipt capabilities to a reasonable degree when needed and beneficial, within overall system constraints.

11 - NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Data for Bistline, et al. (2025) "Policy Implications of Net-Zero Emissions: A Multi-Model Analysis of United States Emissions and Energy System Impacts"

These files contain input assumptions, results, and figures associated with the Bistline, et al. (2025) article "Policy Implications of Net-Zero Emissions: A Multi-Model Analysis of United States Emissions and Energy System Impacts" in Energy and Climate Change as part of the Energy Modeling Forum 37 study. Please refer to the original paper for details.

climate policy↗

A Gas Giant Planet in the OGLE-2006-BLG-284L Stellar Binary System

We present the analysis of microlensing event OGLE-2006-BLG-284, which has a lens system that consists of two stars and a gas giant planet with a mass ratio of q {sub p} = (1.26 ± 0.19) × 10{sup −3} to the primary. The mass ratio of the two stars is q {sub s} = 0.289 ± 0.011, and their projected separation is s {sub s} = 2.1 ± 0.7 au, while the projected separation of the planet from the primary is s {sub p} = 2.2 ± 0.8 au. For this lens system to have stable orbits, the three-dimensional separation of either the primary and secondary stars or the planet and primary star must be much larger than the projected separations. Since we do not know which is the case, the system could include either a circumbinary or a circumstellar planet. Because there is no measurement of the microlensing parallax effect or lens system brightness, we can only make a rough Bayesian estimate of the lens system masses and brightness. We find host star and planet masses of M{sub L1}=0.35{sub −0.20}{sup +0.30} M{sub ⊙}, M{sub L2}=0.10{sub −0.06}{sup +0.09} M{sub ⊙}, and m{sub p}=144{sub −82}{sup +126} M{sub ⊕}, and the K-band magnitude of the combined brightness of the host stars is K{sub L}=19.7{sub −1.0}{sup +0.7}. The separation between the lens and source system will be ∼90 mas in mid-2020, so it should be possible to detect the host system with follow-up adaptive optics or Hubble Space Telescope observations.

79 ASTRONOMY AND ASTROPHYSICS↗

Analysis of short‐ and long‐term system response during gas production from a gas hydrate deposit at the UBGH2‐6 site of the Ulleung Basin in the Korean East Sea

Abstract This study is a continuation of an investigation into the feasibility of long‐term production from a marine hydrate accumulation that has the properties and conditions of the UBGH2‐6 (UBGH2, Ulleung Basin Gas Hydrates 2; 2 is the number of the scientific expedition) site at the Ulleung Basin in the Korean East Sea. The 12.7 m‐thick system is in deep water (2157 m), but at 140 m below the seafloor. It is characterized by alternating hydrate‐free clays and muds and hydrate‐rich sand layers. The layered stratigraphy and the presence of mud layers favours the use of vertical wells rather than horizontal wells for production. The analysis indicates that production from such a hydrate accumulation is technically feasible, but the gas production rates are generally low. Water production accompanying gas production from this deposit appears manageable under all the scenarios investigated in this study, however, the water‐to‐gas ratio is high. Subsidence at the ocean floor at the end of a 14 day test is quite limited. However, there is significant uncertainty in the predictions of the geomechanical system's behaviour because they are not based on measured system properties but only on estimates/assumptions from analogues. The long‐term production potential of the reservoir at the site investigated here appears challenging because of the limited effectiveness of dissociation and large water production, in addition to substantial subsidence.

Moridis, George J.↗

Techno-Economic Analysis of Reversible and Paired Solid Oxide Cell Systems for Hydrogen Production

This is the Journal of the Electrochemical Society manuscript that details an NETL analysis on comparing the performance and cost of reversible solid oxide cell (SOC) units versus paired fuel cell (SOFC) and electrolysis cell (SOEC) units. The analysis compares tradeoffs such as capital costs versus rate of performance degradation, sensitivity to natural gas prices, sensitivity to imported power costs, and other relevant analyses. The systems include a high rate (98%) of carbon capture. The analysis shows that given a certain cost of electricity input, either approach could be viable in the market and points to the need to incorporate into a full system to understand impacts.

Noring, Alex↗

Automated Vulnerability Detection (AVUD) for Compiled Smart Grid Software

This project developed and implemented a system for conducting cybersecurity vulnerability detection of smart grid components and systems by performing static analysis of compiled software (“firmware”). The resulting system for automated vulnerability detection (AVUD) was implemented as part of Oak Ridge National Laboratory’s existing test bed for smart meters, the Sustainable Campus Initiative. The work consisted of two phases: the first phase implemented the necessary software and computational models to perform the analysis, and the second phase demonstrated the system on example firmware in partnership with smart meter manufacturer Sensus USA, Inc. The resulting system won an R&D 100 award and has been successfully commercialized, winning a National Laboratory Consortium Commercialization Award.

97 MATHEMATICS AND COMPUTING↗

Traveling Wave Energy Analysis of Faults on Power Distribution Systems

This paper explores the most important factors that define the Traveling Wave (TW) propagation on distribution systems. The factors considered in this work are: the distance to the fault location, the fault type, and the crossing of system elements (such as regulators, capacitor banks, laterals, and extra loads within the protection zones). This work uses a realistic, yet simplified, distribution system composed of two protection zones, in which, several combinations of the previously mentioned factors are considered. The simulated fault measurements undergo a signal processing stage in which, first, they are decomposed into independent modes using the Karrenbauer transform. Second, a time–frequency representation is obtained using the Stationary Wavelet Transform (SWT), dividing the signal into several frequency bands. Finally, the Parseval’s Energy (PE) theorem is applied to calculate the signal energy in each frequency band. A qualitative analysis is performed based on the previously calculated energies to outline which are the factors that most affect the TW energy during propagation. The results show that distance, the presence of regulators, either in the propagation path or upstream, and the type of fault are the main factors that affect TW propagation across the system, and therefore they should be considered for TW-based protection schemes for distribution systems.

Jiménez-Aparicio, Miguel (ORCID:000000016864461X)↗

Gastight rotating cylinder electrode: Toward decoupling mass transport and intrinsic kinetics in electrocatalysis

Abstract Decoupling and understanding the various mass, charge, and heat transport phenomena involved in the electrocatalytic transformation of small molecules (i.e., CO 2 , CO, H 2 , N 2 , NH 3 , O 2 , and CH 4 ) is challenging but it can be readily achieved using dimensionless quantities (i.e., Reynolds, Sherwood, Schmidt, Damköhler, Nusselt, Prandtl, and Peclet Numbers) to simplify the characterization of systems with multiple interacting physical phenomena. Herein we report the development of a gastight rotating cylinder electrode cell with well‐defined mass transport characteristics that can be applied to experimentally decouple mass transfer effects from intrinsic kinetics in electrocatalytic systems. The gastight rotating cylinder electrode cell enables the dimensionless analysis of electrocatalytic systems and should enable the rigorous research and development of electrocatalytic technologies.

Jang, Joonbaek↗

Approaches for handling high-dimensional cluster expansions of ionic systems

Disordered multicomponent systems attract great interest due to their engineering design flexibility and subsequent rich space of properties. However, detailed characterization of the structure and atomic correlations remains challenging and hinders full navigation of these complex spaces. A lattice cluster expansion is one tool to obtain configurational and energetic resolution. While in theory a cluster expansion can be applied to any system of any dimensionality, the method has primarily been used in binary systems or ternary alloys. Here we apply cluster expansions in high-component ionic systems, setting up the largest cluster expansion ever attempted to our knowledge. In doing so, we address and discuss challenges specific to high-component ionic systems, namely charge state assignments, structural relaxations, and rank-deficient systems. We introduce practical procedures to make the fitting and analysis of complex systems tractable, providing guidance for future computational studies of disordered ionic systems.

25 ENERGY STORAGE↗

Comparison of Dead-Time Effects in a WPT System Inverter for Different Fixed-Frequency Modulation Techniques

In this paper, a comparative study of the dead-time effects in a wireless power transfer (WPT) system inverter is performed for different fixed-frequency control techniques. The dead-time is provided between the complementary switching instances of the inverter phase-legs to ensure safe operation of the input power source. Under certain operating conditions, the dead-time results in waveform distortions or voltage-polarity reversal (VPR) at the inverter output. The VPR affects the switching characteristics, harmonic spectrum, switching losses, and output voltage/power of the system. A detailed analysis of the dead-time effect on the WPT system parameters such as output voltage and output power is conducted for the different fixed-frequency control strategies (i.e., traditional phase-shift control, asymmetrical clamped-mode, and asymmetrical duty-cycle control). Furthermore, the impact of dead-time on the inverter switching losses is compared for the different control strategies.

Kavimandan, Utkarsh↗

Analysis and Mitigation of Cascading Failures Using a Stochastic Interaction Graph with Eigen-analysis

In studies on complex network systems using graph theory, eigen-analysis is typically performed on an undirected graph model of the network. However, when analyzing cascading failures in a power system, the interactions among failures suggest the need for a directed graph beyond the topology of the power system to model directions of failure propagation. To accurately quantify failure interactions for effective mitigation strategies, this paper proposes a stochastic interaction graph model and associated eigen-analysis. Different types of modes on failure propagations are defined and characterized by the eigenvalues of a stochastic interaction matrix, whose absolute values are unity, zero, or in between. Finding and interpreting these modes helps identify the probable patterns of failure propagation, either local or widespread, and the participating components based on eigenvectors. Then, by lowering the failure probabilities of critical components highly participating in a mode of widespread failures, cascading can be mitigated. Here, the validity of the proposed stochastic interaction graph model, eigen-analysis and the resulting mitigation strategies is demonstrated using simulated cascading failure data on an NPCC 140-bus system.

24 POWER TRANSMISSION AND DISTRIBUTION↗