Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “synchrotrons”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,135 records · Page 63

Study of perovskite CsPbBr 3 detector polarization and its mitigation with ultrahigh x-ray flux

High-flux capable semiconductor x-ray detectors are essential in various applications, but the detrimental effects of detector polarization limit their use in many cases. Here, for this work, we studied the polarization of perovskite CsPbBr 3 semiconductor detectors using ultrahigh flux synchrotron x rays (10 6 –10 12 photons s –1 mm –2 at 58.61 keV). The CsPbBr 3 detectors did not show immediate polarization prominently until a flux higher than 10 10 photons s –1 mm –2 . Using the pump-and-probe technique, we visualized the spatial and temporal effects of polarization. The polarized region, represented by reduced photocurrent, extended beyond the area under direct irradiation, and the reduced photocurrent persisted after potential de-polarization treatments. We found that stronger applied electric fields and fewer carrier traps can mitigate polarization, represented by less photocurrent deficit. By examining the detectors’ current response under controlled ambient light, low, and high-flux x rays, we studied the trap filling and release behavior of CsPbBr 3 . We discovered that the polarization is caused by partial detector damage due to deep defects generated by ultrahigh flux x-ray irradiation. Our work provides insight into CsPbBr 3 polarization under extremely intense x-ray radiation and shows that reducing crystal defects and increasing detector bias voltage are effective solutions.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Compact, portable, automatic sample changer stick for cryostats and closed-cycle refrigerators

Beamlines are facilities that produce and deliver highly focused and intense beams of radiation, typically x rays, synchrotron radiation, or neutrons, for scientific research purposes. Millions of dollars are spent annually to maintain and operate these scientific beamlines, oftentimes running continuously between cycles. To reduce human intervention and improve productivity, mechanical sample changers are often commissioned for use. Designing sample changers is difficult because mechanical parts can be bulky, expensive, and challenging to design for instruments with low volume access, high radiation, and cryogenic environments. We present a portable and inexpensive sample changer stick that can hold and manipulate up to four samples, specifically designed for use with cryogenic closed-cycle refrigerators. The sample changer stick enables rapid and efficient exchange of samples without manual intervention, and is compatible with standard sample mounts such as vanadium cans. The sample changer stick includes a motorized rotation and lancing mechanism, which enables the precise positioning of each sample in the neutron beam, while ensuring compatibility with the operating temperatures and vacuum conditions required for closed-cycle refrigerators. The design has been successfully tested at the VISION beamline at the Spallation Neutron Source. The mechanical action and software controls are detailed. Furthermore, the sample changer stick is a valuable tool for scientists working with cryogenic closed-cycle refrigerators.

36 MATERIALS SCIENCE↗

In situ spin coater for multimodal grazing incidence x-ray scattering studies

We present herein a custom-made, in situ, multimodal spin coater system with an integrated heating stage that can be programmed with spinning and heating recipes and that is coupled with synchrotron-based, grazing-incidence wide- and small-angle x-ray scattering. The spin coating system features an adaptable experimental chamber, with the ability to house multiple ancillary probes such as photoluminescence and visible optical cameras, to allow for true multimodal characterization and correlated data analysis. This system enables monitoring of structural evolutions such as perovskite crystallization and polymer self-assembly across a broad length scale (2 Å–150 nm) with millisecond temporal resolution throughout a complete thin film fabrication process. The use of this spin coating system allows scientists to gain a deeper understanding of temporal processes of a material system, to develop ideal conditions for thin film manufacturing.

47 OTHER INSTRUMENTATION↗

Response of ZrC to swift heavy ion irradiation

Zirconium carbide (ZrC) is commonly used for energy sector research, as well as a surrogate for the proposed advanced nuclear fuel candidate uranium carbide. Here this study investigates structural modifications to nanocrystalline and microcrystalline ZrC resulting from dense electronic excitations induced by swift heavy ion exposure. Samples were irradiated with 946 MeV Au ions to various fluences up to 6 × 10 13 ions cm –2 and characterized using synchrotron-based x-ray diffraction. The evolution of the unit-cell parameter and heterogeneous microstrain were evaluated as a function of fluence and compared with those of nanocrystalline and microcrystalline CeO 2 (a surrogate for UO 2 fuel) irradiated under identical conditions. Distinct differences were observed in the radiation responses of the carbide and oxide across both grain sizes. Most notably, microcrystalline ZrC exhibits swelling characterized by two distinct regimes, which does not result in saturation at the ion fluences achieved. This contrasts with CeO 2 , which exhibits the well-documented direct-impact defect accumulation mechanism, reaching a steady-state saturation of swelling at higher fluences. Nanocrystalline CeO 2 undergoes more pronounced swelling compared with microcrystalline CeO 2 , in contrast to nanocrystalline ZrC, which exhibits only minimal unit-cell changes. These results demonstrate that swift heavy ion-induced structural changes can be quite different in carbides and oxides, which must be considered when extrapolating fission-fragment type damage in current fuels to advanced fuels.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Simultaneous measurements of volume, pressure, optical images, and crystal structure with a dynamic diamond anvil cell: A real-time event monitoring system

The dynamic diamond anvil cell (dDAC) technique has attracted great interest because it possibly provides a bridge between static and dynamic compression studies with fast, repeatable, and controllable compression rates. The dDAC can be a particularly useful tool to study the pathways and kinetics of phase transitions under dynamic pressurization if simultaneous measurements of physical quantities are possible as a function of time. We report the development of a real-time event monitoring (RTEM) system with dDAC, which can simultaneously record the volume, pressure, optical image, and structure of materials during dynamic compression runs. In particular, the volume measurement using both Fabry–Pérot interferogram and optical images facilitates the construction of an equation of state (EoS) using the dDAC in a home-laboratory. We also developed an in-line ruby pressure measurement (IRPM) system to be deployed at a synchrotron x-ray facility. This system provides simultaneous measurements of pressure and x-ray diffraction in low and narrow pressure ranges. The EoSs of ice VI obtained from the RTEM and the x-ray diffraction data with the IRPM are consistent with each other. The complementarity of both RTEM and IRPM systems will provide a great opportunity to scrutinize the detailed kinetic pathways of phase transitions using dDAC.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

New dynamic diamond anvil cell for time-resolved radial x-ray diffraction

The dynamic diamond anvil cell (dDAC) is a recently developed experimental platform that has shown promise for studying the behavior of materials at strain rates ranging from intermediate to quasi-static and shock compression regimes. Combining dDAC with time-resolved x-ray diffraction (XRD) in the radial geometry (i.e., with incident x-rays perpendicular to the axis of compression) enables the study of material properties such as strength, texture evolution, and deformation mechanisms. This work describes a radial XRD dDAC setup at beamline P02.2 (Extreme Conditions Beamline) at DESY’s PETRA III synchrotron. Time-resolved radial XRD data are collected for titanium, zirconium, and zircon samples, demonstrating the ability to study the strength and texture of materials at compression rates above 300 GPa/s. In addition, the simultaneous optical imaging of the DAC sample chamber is demonstrated. The ability to conduct simultaneous radial XRD and optical imaging provides the opportunity to characterize plastic strain and deviatoric strain rates in the DAC at intermediate rates, exploring the strength and deformation mechanisms of materials in this regime.

47 OTHER INSTRUMENTATION↗

Static and shock compression studies of eutectic high-entropy alloy AlCoCrFeNi 2.1 to ultrahigh pressures

The high-entropy alloy with composition AlCoCrFeNi 2.1 , additively manufactured with the laser powder-bed fusion technique, has a far-from-equilibrium BCC/FCC eutectic nanolamellar structure. We studied the high-pressure response of this alloy under both static compression and high-strain rate shock compression. The response to static compression using a diamond anvil cell was studied at pressures up to 302 GPa with synchrotron x-ray diffraction at the advanced photon source. The high-pressure FCC-only phase of the EHEA previously observed by Pope et al. [AIP Adv. 13, 035124 (2023)] is found to be stable up to the highest pressure achieved in this study with a volume compression of V/V 0 = 0.587 at ambient temperature. The shock experiments were performed by using GEKKO XII lasers at the Institute of Laser Engineering, Osaka University. The principal Hugoniot equation-of-state of the EHEA was measured up to a pressure of 515 GPa and a compression of V/V 0 = 0.613. Additionally, the thermal equation of state of the EHEA was measured up to 6.2 GPa and 1623 K using a large-volume Paris–Edinburgh cell to obtain the temperature dependence of bulk modulus and thermal expansion coefficients. The melting temperature for EHEA AlCoCrFeNi 2.1 at a pressure of 5.6 GPa was measured to be 1648 ± 25 K. These results can be used to refine stochastic (or special) quasi-random structure (SQS) models for high-pressure high-temperature behavior of high-entropy alloys.

36 MATERIALS SCIENCE↗

In situ x-ray imaging to understand subsurface behavior during continuous wave laser drilling

A limited understanding regarding the underlying dynamics and mechanisms of material removal during continuous wave laser drilling has presented significant challenges in achieving precision and process control. Here, to address this, we employed high-fidelity, in situ synchrotron x-ray imaging to reveal previously unknown material behaviors during continuous wave laser drilling with power modulation. Our findings highlight that high-aspect ratio drill holes are achieved when the laser modulation frequency falls within the range of 8–12 kHz, provided that the laser average power and modulation amplitude levels meet the specified limits. Under these conditions, we identified a material removal mechanism driven by incremental accumulation of recoil pressure that gradually pushes material upward from deep within the substrate to the surface. This mechanism manifested as a low-frequency fluctuation in the vapor depression depth, resulting in periodic instances of material ejection. Furthermore, our study underscores that rapid expansion of the melt pool and the widening of the drill hole opening can impede effective material removal by redirecting energy from material ejection to increasing the melt pool size. This investigation contributes essential insights into the subsurface dynamics involved in the drilling of high-aspect ratio holes, furthering our fundamental understanding of this intricate process.

47 OTHER INSTRUMENTATION↗

Improvements to the characterization of Agfa x-ray film for use on opacity spectroscopy diagnostics

The National Ignition Facility uses a soft x-ray opacity spectrometer for x-ray spectral imaging in high-energy-density experiments. The increased demand for a better spectral resolution prompted the investigation into the Agfa D4 film. Characterization is already under way for the film. A Manson x-ray source using six different anodes was used to expose film to the linear optical density (OD) region. This is a continuation of the previous work, and the updated analysis process is communicated here. The identified uncertainties have been reduced with the updated steps that improve the results of the characterization process. In conclusion, when the Stanford Synchrotron Radiation Lightsource Beamline 16-2 was operational, the film was characterized at that source. Its beam offered a higher fluency with a lower exposure time needed to reach saturation. Results for both sources are compared in this paper.

47 OTHER INSTRUMENTATION↗

Interface instabilities in hafnium hydride entrained iron metal matrix composites

The chemical interactions in Fe–HfH 2 metal matrix composites (MMCs) are studied across multiple length scales to elucidate the decomposition of the parent phases and corresponding reaction zone physics during direct current sintering. Fe–HfH 2 composites were synthesized with increasing as-mixed hydride contents of Fe–25% HfH 2 , Fe–40% HfH 2 , Fe–55% HfH 2 , and Fe–70% HfH 2 (all in vol. %) to demonstrate the ability to achieve sintered MMCs with target hydride contents. Samples were probed across multiple length scales through a multi-modal workflow employing x-ray diffraction, scanning electron microscopy and segmentation analysis, and synchrotron techniques including hard x-ray fluorescence mapping and nanoprobe x-ray absorption near-edge structure measurements. Under the selected sintering temperature and pressure conditions, hydrogen evolution is seen to evolve through parallel paths: thermal decomposition from during the transformation of HfH 2 to HfH x<2 and through subsequent reaction with the Fe matrix leading to intermetallic phase formation. Specifically, HfFe and HfFe 2 intermetallic formation accelerates the release of hydrogen with a subsequent HfO 2 phase forming at grain boundaries. For this MMC, the consumption or loss of hydrogen can be considerable in compacts with initial hydride loading of 25%–40% HfH 2 approaching 83% hydrogen loss for the lower volume fraction composites. Increasing the volume fraction of HfH 2 to 70% enhanced the retained hydrogen content to 53% and attributed to the reduced interfacial area intrinsic to the increased HfH 2 loading in this MMC.

36 MATERIALS SCIENCE↗

Optical design and efficiency measurement of an extreme ultraviolet high-resolution spectrometer for unresolved transition array research

Understanding the structures of the unresolved transition array (UTA) observed in extreme ultraviolet (EUV) spectra from many-electron atoms is crucial for various applications, including fusion science and nanolithography. Here, to measure the fine structure of the UTA from tungsten and tin at around 5 and 13.5 nm at the Tokyo electron beam ion trap, we developed a high-resolution EUV spectrometer. The designed spectrometer achieves a resolving power of λ/dλ > 5000 at 5 and 13.5 nm. The fabricated large-area grating was experimentally examined at beamline BL5B of the UVSOR synchrotron facility to evaluate the diffraction efficiencies and their variation across the ruled area. The measured diffraction efficiencies are 0.65% ± 0.07% at 5 nm (second order) and 7.9% ± 0.2% at 13.5 nm (first order). The variation in the diffraction efficiency across the ruled area is 2.2%, 13.6%, and 10.0% in zeroth, first, and second order diffractions, respectively. The discrepancies in diffraction efficiencies between the experiments and the calculations were 5.2%, 29%, and 35% for the zeroth, first, and second diffraction orders, respectively.

47 OTHER INSTRUMENTATION↗

Analytical model for balling defects in laser melting using rivulet theory and solidification

In laser welding and additive manufacturing communities, the balling (humping) defect is primarily attributed to the Plateau–Rayleigh fluid instability (PRI) with a few authors suggesting fluid jetting and volume conservation as alternative mechanisms. As analytical descriptions of these mechanisms are unavailable, combining them into a single formalism is unfeasible. We present a new model of PRI with higher accuracy, accounting for competition with solidification, to compare the expected behavior with known experimental trends when fluid jetting is neglected. We adapt a rivulet instability model from fluid physics to account for the stabilizing effects of the substrate, which the traditional cylindrical-jet geometry does not account for and estimate the instability growth rate. Our model yields a continuous transition from non-balling to balling hitherto lacking in current literature and predicts instability growth at higher wavelengths with strong sensitivity to the solidification front curvature. While the fluid surface is most unstable for shallow melt pools, the absolute magnitude of balling relevant to printing defects scales with melt pool depth and has a maximum for a given melt pool geometry. Synchrotron-based x-ray radiography of thin samples indicates that PRI growth rates and solidification can be comparable in magnitude and thus compete, as we find in this work. We predict that deviations between model predictions and our experimental results demonstrate the importance of fluid flows and heat transport in the balling process. Our experiments further demonstrate at least one mechanism by which the melt pool length and the balling wavelength are not equivalent, as commonly claimed.

Taylor, Z. [Stanford Univ., CA (United States); SL↗

Symmetry progression and band vs Mott character of CdPS 3 under pressure

Complex chalcogenides are renowned for their tunable electronic, magnetic, and optical properties under external stimuli. The MPX 3 family (M = Mn, Ni, Co, V; X = S, Se) is a platform for many exciting discoveries—especially under compression—although CdPS3 is thought to be different because the Cd center possesses a filled 4d shell, which precludes Mottness. Here, we combine synchrotron-based infrared absorbance and Raman scattering spectroscopies with diamond anvil cell techniques, complementary lattice dynamics calculations, and an analysis of the energy landscape to reveal a series of structural phase transitions in CdPS 3 . We find four distinct pressure-driven transitions, with low frequency modes detectable over the full 35 GPa range of our investigation. A group–subgroup analysis along with our first-principles calculations allows us to partially unravel the space group sequence. For instance, the first critical pressure is a monoclinic C2/m to trigonal $\overline{R}$3 transition at 10 GPa. Despite the softness and overall sensitivity to pressure, we do not locate an insulator-to-metal transition in this pressure range, indicating that the energy scale for gap closure is significantly higher than expected. We discuss these findings in terms of force-induced color change and Mott vs band character in this system.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Implementation of compound refractive lenses for large field-of-view x-ray phase-contrast imaging during hypervelocity impact experiments

Synchrotron x-ray phase-contrast imaging (XPCI) offers time-resolved visualization of dynamic compression phenomena, but its intrinsically small field-of-view (FOV) limits the time that key features remain in frame. A novel approach to enlarge the FOV is achieved by positioning a two-dimensional parabolic compound refractive lens (CRL) upstream of the sample to deliberately defocus the white beam. Ray-tracing simulations and XPCI measurements show that this CRL configuration can expand the beam by ∼50% vertically and ∼15% horizontally based on the full width at half-maximum of the beam. Implementing the CRL, however, attenuates the photon flux and lowers signal-to-noise ratio (SNR). Task-based analysis using a calibration grid (30 μm dots) showed that both setups fail to consistently meet the Rose criterion (SNR ≥ 5) for features of this size in single-bunch imaging. Extrapolating the measured SNR Rose values suggests that the minimum consistently detectable feature lies closer to 30–40 μm for the standard XPCI setup and above 40 μm for CRL-XPCI. Despite this limitation, the CRL configuration nearly doubles the illuminated area, enabling simultaneous tracking of front and rear observations of boron carbide targets subjected to rod and sphere impacts at 1.0–2.6 km/s. Image tracking algorithms and photonic Doppler velocimetry were used to measure penetration and rear-surface velocity histories. Together, these measurements capture crack fronts, penetration, and material breakout, offering new benchmark data for validating high-strain-rate constitutive models of ceramic materials.

Ceramic materials↗

A simple wire-coil resistive heater for high temperature radial x-ray diffraction in a diamond anvil cell

Diamond anvil cells are commonly used at synchrotron x-ray diffraction beamlines to study structural and thermoelastic properties of materials at high pressures. In a radial geometry, where the x-ray probe is oriented perpendicular to the axis of force, the deformation and strength of materials can be measured in situ. Because the anelastic and failure properties of materials depend strongly on temperature, many applications would benefit from the ability to measure high pressure radial diffraction in elevated and accurately controlled thermal environments. Previous work to introduce high temperature to radial diamond anvil cells has been largely limited to laser heating, with relatively scant efforts to resistively heat the sample. Here, we report a relatively straightforward adaptation of a simple wire coil heater, with in situ high-temperature radial diffraction performed on tungsten carbide up to 573 K at beamline 12.2.2 of the Advanced Light Source. In conclusion, the results demonstrate that the differential stress supported by WC decreases with increasing temperature: the differential stress on the basal (001) and pyramidal (101) planes decreased 6.6% and 5.5%, respectively, while the (100) plane only saw a 2.7% decrease, in agreement with previous studies.

Diamond anvil cells↗

Nonlinear elasticity and damping govern ultrafast dynamics in click beetles

Many small animals use springs and latches to overcome the mechanical power output limitations of their muscles. Click beetles use springs and latches to bend their bodies at the thoracic hinge and then unbend extremely quickly, resulting in a clicking motion. When unconstrained, this quick clicking motion results in a jump. While the jumping motion has been studied in depth, the physical mechanisms enabling fast unbending have not. Here, we first identify and quantify the phases of the clicking motion: latching, loading, and energy release. We detail the motion kinematics and investigate the governing dynamics (forces) of the energy release. We use high-speed synchrotron X-ray imaging to observe and analyze the motion of the hinge’s internal structures of four Elater abruptus specimens. We show evidence that soft cuticle in the hinge contributes to the spring mechanism through rapid recoil. Using spectral analysis and nonlinear system identification, we determine the equation of motion and model the beetle as a nonlinear single-degree-of-freedom oscillator. Quadratic damping and snap-through buckling are identified to be the dominant damping and elastic forces, respectively, driving the angular position during the energy release phase. The methods used in this study provide experimental and analytical guidelines for the analysis of extreme motion, starting from motion observation to identifying the forces causing the movement. Here, the tools demonstrated here can be applied to other organisms to enhance our understanding of the energy storage and release strategies small animals use to achieve extreme accelerations repeatedly.

59 BASIC BIOLOGICAL SCIENCES↗

hpMCA: A Python-based Graphical Program for Energy Dispersive X-Ray Diffraction Data Collection and Analysis

Energy-dispersive X-ray diffraction (EDXD) at synchrotron beamlines is commonly used for the study of material properties under high pressure and/or high temperature. Experimenters typically rely on the availability of robust data collection and analysis at a beamline, but this has become increasingly difficult, especially with the introduction of multi-element detectors that generate complex, multi-dimensional data sets. These data sets have energy resolution, and they can also be resolved in relation to sample position, diffraction angle, or different external stimuli. We report a new Python-based graphical program, hpMCA, for EDXD data collection and analysis that streamlines the experimental process for the beamline users. The program features a user-friendly interface, capability for online viewing and analyzing data from multi-element energy-dispersive detectors, and includes features useful for working with samples under high pressure and/or high temperature, such as crystal phase identification, real-time unit cell lattice refinement, and pressure determination based on an equation of state.

data analysis software↗

High-throughput small-angle X-ray scattering reveals effective structure factor transitions linked to high-concentration antibody viscosity

High-concentration monoclonal antibody (mAb) formulations are often constrained by elevated viscosity, largely driven by protein–protein interactions, which complicates manufacturing and limits subcutaneous delivery. Early viscosity risk assessment is essential during discovery, yet traditional measurements require large sample volumes, and lack high-throughput capability. Here, we develop a high-throughput small-angle X-ray scattering (SAXS) protocol to detect mAb self-association at dilute concentrations, enabling early predictive insights into high-concentration viscosity. Synchrotron SAXS measurements were conducted for 21 mAbs formulated in a histidine buffer at pH 6.0. An initial subset of 10 mAbs analyzed across 1–150 mg/mL revealed that effective structure factor transitions in the low-q region, indicative of interparticle interactions, consistently emerged below 25 mg/mL. Subsequently, 11 additional mAbs were analyzed at 1–25 mg/mL using automated liquid handling and flow cells to enable high-throughput screening. High-viscosity mAbs exhibited detectable low-q upturns at concentrations ≤10 mg/mL, whereas low-viscosity mAbs showed downturns. A classification criterion based on effective structure factor transitions accurately classified all high- and low-viscosity mAbs at 150 mg/mL, offering a scalable, sample-efficient alternative to conventional methods. These results extend recent findings on the concentration-dependent sensitivity of SAXS to short-range attractions, demonstrating that they can emerge at lower concentrations than previously reported. This study presents the most comprehensive and diverse SAXS dataset for mAbs reported to date within a single formulation, providing a valuable resource for developing and validating coarse-grained models that can more accurately capture intermolecular interactions governing high-concentration solution behavior, thereby enabling rational antibody engineering and improved developability.

36 MATERIALS SCIENCE↗