Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “standardized data”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,135 records · Page 63

Observation of $\gamma\gamma\to\tau\tau$ in proton-proton collisions and limits on the anomalous electromagnetic moments of the $\tau$ lepton

The production of a pair of τ leptons via photon–photon fusion, ${{\unicode{x03B3}\unicode{x03B3}\to\unicode{x03C4}\unicode{x03C4}}}$, is observed for the first time in proton–proton collisions, with a significance of 5.3 standard deviations. This observation is based on a data set recorded with the CMS detector at the LHC at a center-of-mass energy of 13 TeV and corresponding to an integrated luminosity of 138 fb$^{−1}$. Events with a pair of τ leptons produced via photon–photon fusion are selected by requiring them to be back-to-back in the azimuthal direction and to have a minimum number of charged hadrons associated with their production vertex. The τ leptons are reconstructed in their leptonic and hadronic decay modes. The measured fiducial cross section of ${{\unicode{x03B3}\unicode{x03B3}\to\unicode{x03C4}\unicode{x03C4}}}$ is $\sigma^\text{fid}_\text{obs} = 12.4 ^{+3.8}_{-3.1}\,\textrm{fb}$. Constraints are set on the contributions to the anomalous magnetic moment (${a_{\unicode{x03C4}}}$) and electric dipole moments (${d_{\unicode{x03C4}}}$) of the τ lepton originating from potential effects of new physics on the $\unicode{x03B3}\unicode{x03C4}\unicode{x03C4}$ vertex: ${a_{\unicode{x03C4}}} = 0.0009_{-0.0031}^{+0.0032}$ and $|{d_{\unicode{x03C4}}}| \lt 2.9\times 10^{-17}\,{e}\,\textrm{cm}$ (95% confidence level), consistent with the standard model.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Cambium 2024 Scenario Descriptions and Documentation

The National Renewable Energy Laboratory's (NREL's) Cambium data sets are annually released sets of simulated hourly data for a range of modeled futures of the U.S. electric sector with metrics designed to be useful for long-term decision- making. The 2024 Cambium data set is the fifth annual release. The data sets are a companion product to NREL's Standard Scenarios, which are likewise released annually and are a set of projections of how the U.S. electric sector could evolve across a suite of different potential futures, but covering more scenarios with less temporal granularity. Information about Cambium and related publications can be found at https://www.nrel.gov/analysis/cambium.html, and the Cambium data sets can be viewed and downloaded at https://scenarioviewer.nrel.gov/. In this documentation, we describe Cambium 2024's scenarios, define the metrics, and document the Cambium-specific methods for calculating those metrics.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Physics‐based iterative reconstruction for dual‐source and flying focal spot computed tomography

Purpose For single‐source helical Computed Tomography (CT), both Filtered‐Back Projection (FBP) and statistical iterative reconstruction have been investigated. However, for dual‐source CT with flying focal spot (DS‐FFS CT), a statistical iterative reconstruction that accurately models the scanner geometry and acquisition physics remains unknown to researchers. Therefore, our purpose is to present a novel physics‐based iterative reconstruction method for DS‐FFS CT and assess its image quality. Methods Our algorithm uses precise physics models to reconstruct from the native cone‐beam geometry and interleaved dual‐source helical trajectory of a DS‐FFS CT. To do so, we construct a noise physics model to represent data acquisition noise and a prior image model to represent image noise and texture. In addition, we design forward system models to compute the locations of deflected focal spots, the dimension, and sensitivity of voxels and detector units, as well as the length of intersection between x‐rays and voxels. The forward system models further represent the coordinated movement between the dual sources by computing their x‐ray coverage gaps and overlaps at an arbitrary helical pitch. With the above models, we reconstruct images by an advanced Consensus Equilibrium (CE) numerical method to compute the maximum a posteriori estimate to a joint optimization problem that simultaneously fits all models. Results We compared our reconstruction with Siemens ADMIRE, which is the clinical standard hybrid iterative reconstruction (IR) method for DS‐FFS CT, in terms of spatial resolution, noise profile, and image artifacts through both phantoms and clinical scan datasets. Experiments show that our reconstruction has a higher spatial resolution, with a Task‐Based Modulation Transfer Function (MTF task ) consistently higher than the clinical standard hybrid IR. In addition, our reconstruction shows a reduced magnitude of image undersampling artifacts than the clinical standard. Conclusions By modeling a precise geometry and avoiding data rebinning or interpolation, our physics‐based reconstruction achieves a higher spatial resolution and fewer image artifacts with smaller magnitude than the clinical standard hybrid IR.

Wang, Xiao↗

Weatherization Assistant NEAT/MHEA

The software provides a measure selection technique indicating cost effective retrofit activities that can be applied to a home using a standard Savings to Investment Ratio (SIR). Users must provide an input file describing the characteristics of the home to be evaluated. The software takes the input data provided and calculates energy savings and cost savings predicted for a standard set of measures given the input parameters. The Weatherization Assistant computes estimates of pre-retrofit whole building space heating and cooling energy consumptions based on the house description data supplied by the user. The consumptions are computed using a monthly heating and cooling variable base degree-day method by algorithms similar to those developed for the CIRA program [LBL, 1982]. The building consumptions are needed in computing the energy savings from measures affecting the efficiencies of the heating and cooling equipment. Weatherization Assistant then computes the energy savings and costs for each individual measure applicable to the building described as if it were the only measure installed in the house. From these energy savings, a discounted dollar savings over the life of each measure is computed. The ratio of this dollar savings to the cost of installing the measure, the "savings-to-investment ratio" (SIR), is used in an initial ranking of the measures' effectiveness. The "interacted" savings and SIR of measures are then determined assuming the measures are added to the house collectively, in order of their ranking, e.g., the second ranked measure is installed in the house initially described by the user after having been modified by the first ranked measure. If this second-ranked measure's updated SIR is greater than a user-defined limit, the measure is left implemented, else it is removed so that the next measure's effectiveness is not dependent on it. The choice between two mutually exclusive measures (such as different levels of insulation) is made on the basis of their "net present value" (NPV), the difference of life-time savings and installation cost, rather than their SIR. This has been shown to be the more correct criterion on which to base the selection between two measures, both of which cannot be installed. The audit computes and reports to the user the energy savings, discounted dollar savings, installation cost, and SIR for each measure considered cost-effective. For those with SIR greater than the user-designated cutoff, a materials list gives the material name, type, and quantity required for installation of the measure. Weatherization Assistant permits entry of pre-retrofit billing data for gas or electrically heated homes or homes with electric air-conditioning. The user may then make the decision to have the savings of the measures adjusted to reflect the difference in billed consumption and that predicted by the program.

Gettings, Michael↗

Full event interpretation with machine-learning-based particle-flow reconstruction in the CMS detector

The particle-flow (PF) algorithm constructs a global description of each particle collision by producing a comprehensive list of final-state particles, and is central to event reconstruction in the CMS experiment at the CERN LHC. The existing PF implementation relies on physics-motivated heuristics and assumptions that can be replaced by machine-learning (ML) models trained directly on simulated data and naturally suited to modern graphics processing units (GPUs). A state-of-the-art ML-based PF (MLPF) reconstruction algorithm, implemented within the CMS software framework, is presented. The MLPF algorithm performs a learnable full-event reconstruction on GPUs, generalizes across detector conditions and collision energies, and replaces multiple modular reconstruction steps with a single unified model. Physics performance comparable to standard PF reconstruction is achieved in both simulation and data, with improved jet energy resolution and inference time. In simulated top quark-antiquark events under LHC Run-3 (2023-2024) conditions, the jet energy resolution improves by 10-20% for jets with transverse momentum between 30-100 GeV. Inference time is evaluated using simulated multijet events, with a median of $20\,\hbox {ms}$ per event on an Nvidia L4 GPU, compared to approximately $110\,\hbox {ms}$ for the standard CMS PF reconstruction.

Hayrapetyan, Aram [Yerevan Phys. Inst.]↗

The United States COVID-19 Forecast Hub dataset

Academic researchers, government agencies, industry groups, and individuals have produced forecasts at an unprecedented scale during the COVID-19 pandemic. To leverage these forecasts, the United States Centers for Disease Control and Prevention (CDC) partnered with an academic research lab at the University of Massachusetts Amherst to create the US COVID-19 Forecast Hub. Launched in April 2020, the Forecast Hub is a dataset with point and probabilistic forecasts of incident cases, incident hospitalizations, incident deaths, and cumulative deaths due to COVID-19 at county, state, and national, levels in the United States. Included forecasts represent a variety of modeling approaches, data sources, and assumptions regarding the spread of COVID-19. The goal of this dataset is to establish a standardized and comparable set of short-term forecasts from modeling teams. These data can be used to develop ensemble models, communicate forecasts to the public, create visualizations, compare models, and inform policies regarding COVID-19 mitigation. These open-source data are available via download from GitHub, through an online API, and through R packages.

60 APPLIED LIFE SCIENCES↗

Cambium 2023 Scenario Descriptions and Documentation

The National Renewable Energy Laboratory's (NREL's) Cambium data sets are annually released sets of simulated hourly emission, cost, and operational data for a range of modeled futures of the U.S. electric sector with metrics designed to be useful for long-term decision- making. The 2023 Cambium data set is the fourth annual release. The data sets are a companion product to NREL's Standard Scenarios, which are likewise released annually and are a set of projections of how the U.S. electric sector could evolve across a suite of different potential futures, but covering more scenarios with less temporal granularity (Gagnon et al. 2024). Information about Cambium and related publications can be found at https://www.nrel.gov/analysis/cambium.html, and the Cambium data sets can be viewed and downloaded at https://scenarioviewer.nrel.gov/. In this documentation, we describe Cambium 2023's scenarios, define the metrics, and document the Cambium-specific methods for calculating those metrics.

24 POWER TRANSMISSION AND DISTRIBUTION↗

The future low-temperature geochemical data-scape as envisioned by the U.S. geochemical community

Data sharing benefits the researcher, the scientific community, and the public by allowing the impact of data to be generalized beyond one project and by making science more transparent. However, many scientific communities have not developed protocols or standards for publishing, citing, and versioning datasets. One community that lags in data management is that of low-temperature geochemistry (LTG). This paper resulted from an initiative from 2018 through 2020 to convene LTG and data scientists in the U.S. to strategize future management of LTG data. Through webinars, a workshop, a preprint, a townhall, and a community survey, the group of U.S. scientists discussed the landscape of data management for LTG – the data-scape. Currently this data-scape includes a “street bazaar” of data repositories. This was deemed appropriate in the same way that LTG scientists publish articles in many journals. The variety of data repositories and journals reflect that LTG scientists target many different scientific questions, produce data with extremely different structures and volumes, and utilize copious and complex metadata. Nonetheless, the group agreed that publication of LTG science must be accompanied by sharing of data in publicly accessible repositories, and, for sample-based data, registration of samples with globally unique persistent identifiers. LTG scientists should use certified data repositories that are either highly structured databases designed for specialized types of data, or unstructured generalized data systems. Recognizing the need for tools to enable search and cross-referencing across the proliferating data repositories, the group proposed that the overall data informatics paradigm in LTG should shift from “build data repository, data will come” to “publish data online, cybertools will find”. Funding agencies could also provide portals for LTG scientists to register funded projects and datasets, and forge approaches that cross national boundaries. Finally, the needed transformation of the LTG data culture requires emphasis in student education on science and management of data.

58 GEOSCIENCES↗

Metadata Standards for the NSE: Core Fields

This standard presents a core set of metadata fields required for each managed digital object within the Nuclear Security Enterprise (NSE). Metadata standardization is a critical enabler for two primary objectives: 1) effectively sharing data, documents, and other digital objects between NSE sites; and 2) supporting digital engineering through the digital thread at the object level. Standardization is necessary for both schemas and vocabularies, meaning that both field standards and value standards must be specified. This document serves as a foundational field standard, recommending a core set of fields that should be uniformly required for all managed digital objects within the NSE.

99 GENERAL AND MISCELLANEOUS↗

Enabling Interoperable SCADA Communications for PV Inverters through Embedded Controllers

The percentage integration of photovoltaic (PV) inverters in the field has increased significantly in the past 5 years. Regardless of the size of the PV plants and the inverters (residential vs. commercial), it is becoming crucial that these devices have the capability to communicate with peers (other smart devices) and with components that are at a hierarchy above the inverters (e.g., supervisory control and data acquisition (SCADA) systems, distributed controllers, and data managers). This project aims to develop a standard SCADA software code for inverters’ embedded controllers that will enable interoperability with other components in the system. To achieve this, the code will be developed using two different protocols: Distributed Network Protocol 3 and International Electrotechnical Commission 61850. The developed code is aimed to be deployed in simple embedded controllers. It will be tested in the National Renewable Energy Laboratory’s (NREL’s) Energy Systems Integration Facility. The tested code will then be made available through Triangle MicroWorks’s (TMW’s) software platform. The primary objectives of this project include training the NREL team with TMW’s embedded controller libraries, developing an interoperable communication code for embedded controllers, successfully testing and deploying the code, and demonstrating the newly developed code in a conference.

14 SOLAR ENERGY↗

Combination of searches for singly produced vectorlike top quarks in 𝑝⁢𝑝 collisions at $\sqrt{𝑠}$ =13 TeV with the ATLAS detector

A combination of searches for the single production of vectorlike top quarks (𝑇) is presented. These analyses are based on proton-proton collisions at $\sqrt{𝑠}$ = 13 TeV recorded in 2015–2018 with the ATLAS detector at the Large Hadron Collider, corresponding to an integrated luminosity of 139 fb −1 . The 𝑇 decay modes considered in this combination are into a top quark and either a Standard Model Higgs boson or a 𝑍 boson (𝑇 → 𝐻⁡𝑡 and 𝑇 → 𝑍⁢𝑡). The individual searches used in the combination are differentiated by the number of leptons (𝑒, 𝜇) in the final state. The observed data are found to be in good agreement with the Standard Model background prediction. Interpretations are provided for a range of masses and couplings of the vectorlike top quark for benchmark models and generalized representations in terms of 95% confidence level limits. For a benchmark signal prediction of a vectorlike top quark SU(2) singlet with electroweak coupling, 𝜅, of 0.5, masses below 2.1 TeV are excluded, resulting in the most restrictive limits to date.

Composite models↗

Building ControlScore: General Service Administration Office Building Deployment

Improvements to building control systems can lead to energy savings and increased occupant comfort. In an optimized system, process variables such as air temperature will closely follow their desired setpoints and avoid excess energy use. Typically, experts must manually inspect individual control loops to identify poor performance and opportunities for improvement. However, this approach is difficult in modern buildings that have a prohibitively large number of controllers. To address this issue, Pacific Northwest National Laboratory (PNNL) created the ControlScore concept, which takes operating data from the many controllers within a building and generates standardized scores for each loop on a scale of 0 to 10 (a score of 0 indicates poor control, a score of 10 indicates good control). PNNL applied the Building ControlScore application to all available data from a General Services Administration office building within the period of January 1, 2023, to March 9, 2023. The building scored a 4.7 overall, with all 74 of the building’s loops fitting a roughly normal distribution centered around 5. These results indicate that the analyzed systems have below-average performance with room for improvement, especially in the poorly scored systems. Airflow loops tended to have much lower scores than zone temperature loops. The lowest and highest performing systems in the building section were identified, as were all loops with a score less than 1. While the ControlScore identifies loops and systems that aren’t meeting their designated setpoints, it does not indicate the cause of those issues. For example, consider a supply air terminal unit’s airflow loop that received a low score due to it delivering less air than specified by the setpoint. The lower-than-desired airflow could be due to equipment limitations (e.g., the terminal unit or duct serving is too small to accommodate that airflow), malfunctioning equipment (e.g., a stuck damper or bad sensor), or something else entirely. The ControlScore does not diagnose problems it simply identifies the symptoms that can be explored and addressed by building operators.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

INGENIOUS Thermal Conductivity Measurement Source Categorization

Thermal conductivity (TC) data taken for different wells at a specified drill depth. This is an abridged version of the complete SMU heat flow database, downloaded from the SMU node of the NGDS at the beginning of INGENIOUS (approximately April 2021), and filtered to the INGENIOUS study area. This National Geothermal Data System (NGDS) project aggregates geothermal data collected and curated by the SMU Geothermal Laboratory and its partner organizations. All columns in this database are the same as the SMU database, except for 2 additions associated with this project. Repeated columns are for data correlation purposes. Column descriptions and data types are the same as previous iterations of the SMU database. The new values that are the addition are two new columns developed as part of the INGENIOUS project: INGENIOUS TC Value | INGENIOUS notes INGENIOUS notes are individual notes that were written for specific data points during the analysis process. There are not always notes associated with each input value. INGENIOUS TC Value includes 4 values: 1. Assumed Measured These are values that are assumed to be measured thermal conductivity values, either within a specific well or within the same study region. Many of these have either a published reference, a reported standard deviation, or a unique thermal conductivity value. 2. Data release - assumed measured These are values in the SMU database that are from proprietary data that were added to the SMU database and are labeled as data release for their reference. These values were searched for in person at the SMU Geothermal Laboratory as well as virtual examination of data available on the NGDS. For many of these, there are reported thermal conductivity values associated with the heat flow data in the database, but no specific table or reference to measurements in the original data release files. 3. Known measured These are values that have a reported measurement, either as an original file in the SMU data files on the NGDS or a reported table in a publication. In the rare circumstances, Maria Richards or David Blackwell confirmed measurement. Confirmation of measurement would be written in the INGENIOUS notes column. 4. Unmeasured Unmeasured values are those that are known to be unmeasured, either estimated from another report or no information given. In the SMU database, there are wells that have a heat flow but no thermal conductivity. These are categorized as unmeasured. There are also heat flow values that are stated to have estimated or generalized average thermal conductivity values for the region and rock type. Because these are known to be unmeasured, they are categorized as such. 5. Blank Blank values are either A quality or X quality. These quality values are stated in the INGENIOUS notes. These values were not going to change associated with the heat flow analysis, so these were not examined.

15 GEOTHERMAL ENERGY↗

Prototype energy models for data centers

Data centers in the United States consume about two percent of the nation’s electricity. Because heat gains from IT equipment drive cooling demand, data centers offer unique opportunities for energy savings. However, no prototype energy model for data centers is available in the suite of existing U.S. Department of Energy’s Commercial Prototype Building Models. Here we present the development of two new data center prototype models and their implementation in OpenStudio and EnergyPlus. The small-size data center model represents a computer room in a building served by computer room air conditioners (CRACs); while the large-sized model represents stand-alone data centers served by computer room air handlers (CRAHs) with a central chiller plant. For each data center model, two levels of IT equipment (ITE) load density were considered, to cover the wide range of IT power density of data centers: 40 and 100 W/ft 2 (430 and 1076 W/m 2 ) for the computer room, and 100 and 500 W/ft 2 (1076 and 5382 W/m 2 ) for the stand-alone data center. All other assumptions, such as building envelope, lighting, HVAC efficiencies and schedules, were based on the minimal requirements of ASHRAE Standard 90.1 at various vintages. We introduced a novel concept of supply and return air approach temperatures to capture the essential effects of non-uniform airflow and temperature distribution in data centers. The approach temperatures were pre-computed by computational fluid dynamics (CFD) simulations for various configurations of ITE loads and airflow containment management in data centers. A new feature was developed in EnergyPlus to implement the approach temperature method. A case study was conducted to demonstrate the use of the data center models. The two data center models cover all U.S. climate zones and can be used to evaluate energy saving measures for data centers, as well as to support development of data center energy efficiency codes and standards.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Photovoltaic Analysis and Response Support (PARS) Platform for Solar Situational Awareness and Resiliency Services

The project's primary objective is to develop a digital-twin based Photovoltaic (PV) Analysis and Response Support (PARS) platform, which aims to provide real-time situational awareness and optimal response plans. This platform is designed to enhance the performance of hybrid PV systems, making them competitive with or even superior to conventional generation resources. The PARS platform enabled the project team to develop and evaluate an extensive suite of grid support functionalities for the hybrid PV systems to enhance grid performance, across key areas including visibility, dispatchability, security, resilience, and reliability. Given the global push toward achieving 100% clean energy by 2035, there is a significant increase in the integration of inverter-based resources (IBRs) throughout the energy grid. Effectively managing the inherent variability and uncertainty associated with IBRs is crucial for ensuring cost-effectiveness, reliability, and security in both the main grid and islanded microgrids. Constrained to a limited array of IEEE test systems or standard feeder models, traditional IBR modeling struggles to assimilate new field data, accurately reflect system dynamics, and adapt to the evolving energy landscape. In our project, we embraced a Digital Twin (DT) strategy for crafting the PARS platform. A digital twin acts as a precise virtual counterpart of a physical system, built on historical data and continuously honed with real-time insights. This enables the high-fidelity DT to accurately mirror current system operations and forecast future scenarios. Consequently, the PARS platform becomes an ideal environment for testing and refining monitoring, control, power, and energy management algorithms designed to boost hybrid PV system performance. The defining feature of the PARS platform, distinguishing it from other advanced simulation tools, is its exceptional adaptability. This is achieved by employing actual network topologies and utilizing real-time field data for fine-tuning and calibration, ensuring a close emulation of real-world conditions. The project deliverables include: 1) High-fidelity IBR models and tools for real-time parameterization, utilizing real-time field measurements to refine IBR models for enhanced accuracy and performance; 2) Grid-forming and Grid-following capabilities to deliver resilience services, including blackstart, voltage and frequency support, cold-load pick-up, power reserves, and three-phase load balancing across grid-connected and microgrid settings; 3) Machine learning-based forecasting tools and methods for generating synthetic data and topologies, creating diverse and realistic simulation environments for evaluating varied operational scenarios; 4) Advanced microgrid power and energy management algorithms for optimizing the integration and operation of PV, storage, and demand response resources within both feeder and community scales. The power grid data sets are provided by four utility companies in North Carolina and the New York Power Administration. Acting as industry advisors, our industry partners communicated stakeholder needs and regulatory standards to the research teams, aiding technology transfer by incorporating the developed methodologies into their daily operations. This collaboration ensures that the PARS platform, functioning as a power system digital twin, enhances our understanding of IBR dynamic behaviors and enables the development and evaluation of IBR control functions that match or exceed the capabilities of conventional synchronous generators.

14 SOLAR ENERGY↗

Gene expression of functionally-related genes coevolves across fungal species: detecting coevolution of gene expression using phylogenetic comparative methods

Researchers often measure changes in gene expression across conditions to better understand the shared functional roles and regulatory mechanisms of different genes. Analogous to this is comparing gene expression across species, which can improve our understanding of the evolutionary processes shaping the evolution of both individual genes and functional pathways. One area of interest is determining genes showing signals of coevolution, which can also indicate potential functional similarity, analogous to co-expression analysis often performed across conditions for a single species. However, as with any trait, comparing gene expression across species can be confounded by the non-independence of species due to shared ancestry, making standard hypothesis testing inappropriate. We compared RNA-Seq data across 18 fungal species using a multivariate Brownian Motion phylogenetic comparative method (PCM), which allowed us to quantify coevolution between protein pairs while directly accounting for the shared ancestry of the species. Our work indicates proteins which physically-interact show stronger signals of coevolution than randomly-generated pairs. Interactions with stronger empirical and computational evidence also showing stronger signals of coevolution. We examined the effects of number of protein interactions and gene expression levels on coevolution, finding both factors are overall poor predictors of the strength of coevolution between a protein pair. Simulations further demonstrate the potential issues of analyzing gene expression coevolution without accounting for shared ancestry in a standard hypothesis testing framework. Furthermore, our simulations indicate the use of a randomly-generated null distribution as a means of determining statistical significance for detecting coevolving genes with phylogenetically-uncorrected correlations, as has previously been done, is less accurate than PCMs, although is a significant improvement over standard hypothesis testing. These methods are further improved by using a phylogenetically-corrected correlation metric. Our work highlights potential benefits of using PCMs to detect gene expression coevolution from high-throughput omics scale data. This framework can be built upon to investigate other evolutionary hypotheses, such as changes in transcription regulatory mechanisms across species.

59 BASIC BIOLOGICAL SCIENCES↗

Neutron powder diffraction, Mossbauer Spectroscopy and Optical Spectroscopy to study magnetic and nuclear lattices in Fe-based oxychlorides Ca2FeO3Cl, Sr2FeO3Cl and Sr3Fe2O5Cl2

Data for Neutron Diffraction, Mossbauer Spectoscopy and Optical Spectroscopy are contained on all three samples (Ca2FeO3Cl, Sr2FeO3Cl, and Sr3Fe2O5Cl2). Mossbauer data are in the folder "MossbauerSpectroscopy". This contains details of files and examples to read the data. The Optical Spectroscopy are in the folder "AbsorptionData", this contains one file with explanatory headers. The neutron diffraction data are in the "NeutronDiffractionData" folder. The data was collected on the HB-2A powder diffractometer at HFIR. The autoreduced files are corrected using a vanadium standard and are in arbitrary intensity units. The RawData folder contains the uncorrected data with metadata for motor positions and temperature. All measurements were collected with a constant neuton wavelength of 2.41 Angstrom. An excel spreadsheet "NeutronDiffractionData_IPTS-29118_summary" contains details for each scan. Sr3Fe2O5Cl2 data were collected at only room temperature. Ca2FeO3Cl and Sr2FeO3Cl data were collected at 4K and room temperature. The autoreduced .dat fileformat is three columns corresponding to: Two-theta, Intensity and Intensity_error.

fe-based oxychlorides↗

Data and Scripts associated with: “Laboratory evaluation of open source and commercial electrical conductivity sensor precision and accuracy”

This data package is associated with the publication “Laboratory evaluation of open source and commercial electrical conductivity sensor precision and accuracy: How do they compare?” submitted to PLOS ONE and accepted for publication (Fulton, S.G. et al. 2023; doi not yet available).Variation in electrical conductivity (EC) of water is important to reveal environmental disturbance and natural dynamics, including factors such as anthropogenic salinization. This data package supports a study addressing the need for a robust performance assessment of open source (OS) EC sensors. We evaluated the accuracy (mean error, %) and precision (sample standard deviation) of OS EC sensors in the laboratory via comparison to EC calibration standards using three different OS and OS/commercial-hybrid (OS/C) EC sensors and data logger configurations and two commercial (C) EC sensors and data logger configurations. We also evaluated the effect of cable length (7.5 m and 30 m) and sensor calibration on OS sensor accuracy and precision. This data package presents the results from the different testing laboratory configurations. It also includes an R script for statistical analysis of the data and an Arduino IDE file used to calibrate and collect data with the OS Atlas EC sensor. File types are .csv, .pdf, .R, and .ino.

54 ENVIRONMENTAL SCIENCES↗