Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “spacecraft”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,135 records · Page 63

SAS-A spacecraft magnetic tests

Magnetic tests were conducted on the spacecraft for: (1) alignment, compensation, calibration, and bias determination for the spacecraft three-axis vector magnetometer; (2) determination of permanent, induced, and stray magnetic moments of the spacecraft and compensation of permanent magnetic moments by permanent magnets; and (3) evaluation of the spin and attitude control system.

Boyle, J. C.↗

Predicting spacecraft self-contamination in space and in a test chamber

The self-contamination of a spacecraft, defined as the return and deposition of outgassed molecules on its critical surfaces, was investigaed. Theoretical relations for the flux, density, and pressure of the emitted gas as a function of altitude, radius, and distance from the spacecraft surface were developed. The flux of these outgassed molecules which return to the emitting surface was also obtained and shown to be dependent on altitude, dimensions, and on the magnitude of outgassing. The rate of condensation and the time for the formation of a monolayer of the returning molecules can be calculated. The self-contamination of a spacecraft undergoing vacuum chamber test was also analyzed and compared to the equivalent parameters for the orbital conditions.

Scialdone, J. J.↗

SSA-A spacecraft magnetic tests

In the initial magnetic tests the spacecraft perm moment as received was 43 milliampere-meter squared (pole-cm), which was reduced by deperm treatment to milliampere-meter squared. Facility fluxgate probe bias results indicated Z axis bias at the SSS-A fluxgate magnetometer position to be about one half nanotesla (gamma) after Z axis deperm. The ASCS magnetometers, 01 and 02, were successfully aligned and proper operation of the ASCS system were verified. The spacecraft fluxgate magnetometer was calibrated in both the high and low sensitivity modes after a defective 01 electronics card was replaced. Problems were encountered in the Z axis search coil during calibration and the test was re-scheduled. Final test results indicated that the total perm moment could not be reduced any lower than 35 milliampere-meter squared by deperm treatment. However, the Z axis moment decreased from 22 milliampere-meter squared to 6 milliampere-meter squared after deperm. Correct operation and calibration was verified for all three axes of the spacecraft fluxgate magnetometer and no significant bias was observed during stray field testing. Null and spot calibration of the ASCS magnetometer was completed and the measured spin and attitude coil moments were: 2535 and 9820 milliampere-meter squared respectively.

Roy, T. N.↗

High-power S-band experiment study: Objectives, description, planning and operation of experiment for ATS-G spacecraft

The results of a study to develop and define requirements for the high power S-band experiment for the ATS-G are summarized. The objectives of the experiment are: (1) to demonstrate high power technology at S-band frequencies in orbiting spacecraft, (2) to employ high power carrier from the spacecraft for conducting interference measurements with Instructional Television Fixed Service systems, and (3) to provide means for performing educationally oriented applications experiments. Experiment organization and operation, and hardware for flight on the ATS-G spacecraft are described. Earth stations designed for the experiment as well as other special ground equipment are also described.

Walp, R. M.↗

UK-4 prototype spacecraft magnetic tests

The spacecraft was tested in a magnetic test facility which uses a 42 ft. diameter coil system to produce a controlled magnetic field of high uniformity over a large central volume. The primary objectives of the tests were: (1) to determine the permanent, induced, and stray magnetic moments of the spacecraft and to assess its magnetic stability; (2) to evaluate the magnetorquer coil system; and (3) to deperm, compensate, and make other adjustments necessary to achieve satisfactory magnetic characteristics for the spacecraft. The test facility and procedures are described together with the results obtained. In addition, the problems encountered during the tests and the significance of the test findings are discussed.

Pruett, W. E.↗

Spacecraft ion beam noise effects

An estimate of the antenna noise temperature and the uplink signal-to-noise ratio has been made for Bremsstrahlung radiation emitted by a spacecraft ion beam; a worst-case situation in which the spacecraft antenna is located in the exit plane of the ion beam and directed at varying angles into the ion beam is assumed. Numerical results of the antenna noise temperature versus antenna pointing angle are given for a typical set of ion beam and antenna pattern parameters. The uplink signal-to-noise ratio due to the ion beam noise alone is given in terms of a critical range in AU at which a typical ranging transmission is received with S/N = 0 db. The effects of the ion beam divergence angle and antenna distance on the ion beam are also presented. Results of the study show typical increases in the antenna noise temperature of about 0.2 K and critical ranges of the order of 3-5 AU. An ion engine thus generally introduces an undetectable level of noise into a spacecraft receiver.

Anenberg, G. L.↗

Flight test of an erectable spacecraft used for decelerator testing at simulated Mars entry conditions

A 55 foot diameter disk-gap-band parachute was deployed behind an expandable 15 foot diameter, 120 deg blunted-cone simulated spacecraft. The spacecraft was carried to altitude in the folded condition. An automatic control system kept the folded spacecraft pointing in the desired direction after booster separation. The aeroshell was then erected at the desired conditions by ground command. When the desired parachute test conditions were reached, another ground command deployed the test parachute. The test Mach number and dynamic pressure obtained at the parachute peak load were 2.62 and 19.4 pounds per square foot respectively. A large disturbance after aeroshell erection caused a large angle of attack to exist at parachute deployment. Methods of preventing this disturbance are discussed.

Henning, A. B.↗

The electrical power subsystem of the Pioneer F/G spacecraft.

The Pioneer F/G spacecraft is the first to use radioisotope thermoelectric generators (RTG's) for a long duration interplanetary mission. This paper describes the design of the spacecraft power subsystem which meets the unique requirements of such a mission. The primary power source consists of four SNAP 19 RTG's. The 4.2 volt dc outputs of the RTG's are inverted to higher voltage ac by four inverters which are connected in parallel at their outputs. A power control unit (PCU) regulates the ac output of the inverters such that the RTG's are operated at near maximum power voltage throughout the mission. The PCU also contains charge and discharge controls for a silver cadmium battery which supplements the RTG's if load requirements temporarily exceed RTG power output. Battery reliability is enhanced by overcharge and cell reversal protection electronics which are provided for each cell. Multiple, low voltage, regulated dc outputs which supply power to the spacecraft subsystems are provided by a central transformer-rectifier-filter unit (CTRF). The CTRF operates directly from the regulated ac bus.

Reppucci, G. M.↗

Mission analysis for design of a SEP multi-mission spacecraft.

Study of the multimission capability of a solar electric propulsion spacecraft. The study includes such factors as spacecraft constraints, payload variations with launch opportunity, propellant on-loading and off-loading requirements, and limitations in thrusting time, throttling range and steering. The study determined that a single spacecraft design, with P sub zero = 12 kW and I sub s = 3000 sec launched by a Titan IIIC or Titan IIID/Centaur can be used to conduct at least five diverse missions: Eros rendezvous, 1 AU out-of-ecliptic, Mercury orbiter, Jupiter flyby/probe, and Jupiter orbiter. Flight time and injection velocity vary as needed to achieve the desired payload capability. The mission analysis approach and results are presented.

Driver, J. M.↗

Unique solutions of spacecraft structural dynamics problems.

New ideas and techniques recently put to use at the Jet Propulsion Laboratory for structural dynamics of spacecraft are presented. This paper deals with practical problems rather than elaborate mathematical theories and is concerned with the system approach for structural dynamics, an approach which has received attention in the recent past owing to the use of the fast Fourier transform algorithm which permits an economical use of digital computers. Concept of dynamics mass in the frequency domain is introduced. Reaction forces and moments at the base of a spacecraft in boosted flight configuration are determined. A combination of digital and analog techniques for special problems is presented. The examples reported are on actual spacecraft.

Trubert, M. R.↗

Testing relativistic gravity theories using radio tracking data from planetary orbiting spacecraft.

We present a thorough analysis of a computational method for determining the numerical values of the relativity and other related dynamical parameters using two-way Doppler and ranging data from planetary orbiting spacecraft. The computational method consists of two parts. From Doppler data we first determine the earth-planet components of the position of the orbiting spacecraft relative to the center of gravity of the planet to high accuracy; adding the observed spacecraft range yields a range value to the center of the planet. These constructed earth-planet range data, referred to as normal points, are then treated as raw data in a regression analysis combined with planetary radar delay and meridian circle measurements to solve for the significant solar system dynamical parameters. The major errors sources in the planetary orbiter process are enumerated and their individual effects on the overall accuracy of the normal point accuracies are presented. The accuracies of the parameter estimates as a function of time, data sampling, and a priori assumptions are illustrated.

Jordan, J. F.↗

Mission operations for unmanned nuclear electric propulsion outer planet exploration with a thermionic reactor spacecraft.

Mission operations are presented for comet rendezvous and outer planet exploration NEP spacecraft employing in-core thermionic reactors for electric power generation. The selected reference missions are the Comet Halley rendezvous and a Jupiter orbiter at 5.9 planet radii, the orbit of the moon Io. The characteristics of the baseline multi-mission NEP spacecraft are presented and its performance in other outer planet missions, such as Saturn and Uranus orbiters and a Neptune flyby, are discussed. Candidate mission operations are defined from spacecraft assembly to mission completion. Pre-launch operations are identified. Shuttle launch and subsequent injection to earth escape by the Centaur D-1T are discussed, as well as power plant startup and the heliocentric mission phases. The sequence and type of operations are basically identical for all missions investigated.

Spera, R. J.↗

UK-4 flight spacecraft magnetic tests

Magnetic tests conducted on the UK-4 spacecraft are discussed. The objectives of the test are: (1) to determine the permanent, induced, and stray magnetic moments of the spacecraft, (2) to assess its magnetic stability, (3) to determine the dipole moment produced by energizing the magnetorquer coil, (4) to measure the despin torque due to eddy current and magnetic hysteresis, and (5) to deperm, compensate, and make other adjustments necessary to achieve satisfactory magnetic characteristics for the spacecraft.

Pruett, W. E.↗

Automated techniques for spacecraft monitoring

The feasibility of implementing automated spacecraft monitoring depends on four factors: sufficient computer resources, suitable monitoring function definitions, adequate spacecraft data, and effective and economical test systems. The advantages of automated monitoring lie in the decision-making speed of the computer and the continuous monitoring coverage provided by an automated monitoring program. Use of these advantages introduces a new concept of spacecraft monitoring in which system specialists, ground based or onboard, freed from routine and tedious monitoring, could devote their expertise to unprogrammed or contingency situations.

Segnar, H. R.↗

Unmanned planetary spacecraft chemical rocket propulsion.

Review of some chemical propulsion technology advances suitable for future unmanned spacecraft applications. Discussed system varieties include liquid space-storable propulsion systems, advanced liquid monopropellant systems, liquid systems for rendezvous and landing applications, and low-thrust high-performance solid-propellant systems, as well as hybrid space-storable systems. To optimize the performance and operational characteristics of an unmanned interplanetary spacecraft for a particular mission, and to achieve high cost effectiveness of the entire system, it is shown to be essential that the type of spacecraft propulsion system to be used matches, as closely as possible the various requirements and constraints. The systems discussed are deemed to be the most promising candidates for some of the anticipated interplanetary missions.

Burlage, H., Jr.↗

Solid propulsion powered spacecraft concept.

The feasibility and application of a solid propulsion powered spacecraft concept to implement high-energy missions independent of multiplanetary swingby opportunities are assessed. The characteristics of suitable missions and spacecraft were formulated to determine their effects upon propulsion system selection and design. A cost-effectiveness analysis was conducted to provide a meaningful basis of comparing candidate designs. The results substantiated the feasibility of the powered spacecraft concept when used in conjunction with several intermediate-sized launch vehicles as well as energy margins by which to exploit extended mission capabilities. An outgrowth of this study included a new high-mass-fraction solid motor staging design whose performance predictions further enhanced the candidacy of the baseline configuration.

Nakamura, Y.↗

Analyses of flight model spacecraft performance during thermal-vacuum tests.

Malfunction data from the thermal-vacuum tests of 39 flight-model spacecraft have been analyzed. These data are compared to the data listed in the 1968 Technical Note, NASA TN D-4908, 'Time Required for an Adequate Thermal-Vacuum Test of Flight Model Spacecraft', by A. R. Timmins. The present analyses include the relationship of malfunctions to time and temperature of the test, malfunction rates, effect of retest data, and the probability of a malfunction in each of four thermal-vacuum environments. Data are presented that relate a thermal-vacuum test profile to the risk involved using that profile. The minimum thermal-vacuum test profile is verified, and no change is recommended for the present thermal-vacuum test profile for flight model spacecraft.

Timmins, A. R.↗

Gas flow analysis during thermal vacuum test of a spacecraft.

The pressures indicated by two tubulated ionization gages, one pointing to a spinning spacecraft undergoing thermal vacuum test and the other the walls of the chamber, have been used in a computer program to calculate important parameters of flow kinetics in the vacuum chamber. These parameters calculated as a function of time are: the self-contamination of the spacecraft (defined as the return of outgassed molecules on its critical surfaces either in orbit or while undergoing vacuum test); the spacecraft outgassing including leaks from sealed compartments; and the gas pumping performance of the vacuum chamber. The test indicated the feasibility of this type of evaluation and the improvements in instrumentations and arrangements needed for future tests.

Scialdone, J. J.↗