Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “sensor selection”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,135 records · Page 63

Laboratory Evaluation of the Thermal Breakout Method for Maximum Horizontal Stress Measurement

Measuring in situ stress is essential for many problems in geomechanics, and the maximum horizontal stress is the most difficult to constrain. We are developing an extension of the breakout method to measure maximum horizontal stress in regions where natural breakouts do not occur. In the novel thermal breakout method, additional compression which leads to breakout development is induced by heating the borehole wall. In the present study, we validated the method experimentally in a true-triaxial apparatus on samples with predrilled boreholes. Two rocks were selected for laboratory testing: high-porosity Berea sandstone and low-porosity Niagaran dolomite. Prior to main true-triaxial tests, we carried out standard testing to characterize the strength, elasticity and thermal properties. The true-triaxial experiments consisted of: (1) room-temperature tests where samples were first loaded mechanically until the breakout formed, and (2) elevated-temperature tests where samples were loaded mechanically within the elastic range with additional compression induced thermally. Breakout initiation was monitored by acoustic emission sensors mounted on the pistons that applied horizontal stresses. Furthermore, the magnitude of induced thermal stress was calculated from temperature measurements around the borehole wall. In both rock types, we created thermally induced breakouts and examined analytical expressions to constrain maximum horizontal stress based on strength, elastic and thermal properties of the rocks.

58 GEOSCIENCES↗

Network Algorithms for Detection of Radiation Sources

In support of national defense, Domestic Nuclear Detection Office’s (DNDO) Intelligent Radiation Sensor Systems (IRSS) program supported the development of networks of radiation counters for detecting, localizing and identifying low-level, hazardous radiation sources. Industry teams developed the first generation of such networks with tens of counters, and demonstrated several of their capabilities in indoor and outdoor characterization tests. Subsequently, these test measurements have been used in algorithm replays using various sub-networks of counters. Test measurements combined with algorithm outputs are used to extract Key Measurements and Benchmark (KMB) datasets. We present two selective analyses of these datasets: (a) a notional border monitoring scenario that highlights the benefits of a network of counters compared to individual detectors, and (b) new insights into the Sequential Probability Ratio Test (SPRT) detection method, which lead to its adaptations for improved detection. Using KMB datasets from an outdoor test, we construct a notional border monitoring scenario, wherein twelve 2”*2” NaI detectors are deployed on the periphery of 21*21meter square region. A Cs-137 (175 uCi) source is moved across this region, starting several meters from outside and finally moving away. The measurements from individual counters and the network were processed using replays of a particle filter algorithm developed under IRSS program. The algorithm outputs from KMB datasets clearly illustrate the benefits of combining measurements from all networked counters: the source was detected before it entered the region, during its trajectory inside, and until it moved several meters away. When individual counters are used for detection, the source was detected for much shorter durations, and sometimes was missed in the interior region. The application of SPRT for detecting radiation sources requires choosing the detection threshold, which in turn requires a source strength estimate, typically specified as a multiplier of the background radiation level. A judicious selection of this source multiplier is essential to achieve optimal detection probability at a specified false alarm rate. Typically, this threshold is chosen from the Receiver Operating Characteristic (ROC) by varying the source multiplier estimate. ROC is expected to have a monotonically increasing profile between the detection probability and false alarm rate. We derived ROCs for multiple indoor tests using KMB datasets, which revealed an unexpected loop shape: as the multiplier increases, detection probability and false alarm rate both increase until a limit, and then both contract. Consequently, two detection probabilities correspond to the same false alarm rate, and the higher is achieved at a lower multiplier, which is the desired operating point. Using the Chebyshev’s inequality we analytically confirm this shape. Then, we present two improved network-SPRT methods by (a) using the threshold off-set as a weighting factor for the binary decisions from individual detectors in a weighted majority voting fusion rule, and (b) applying a composite SPRT derived using measurements from all counters.

45 MILITARY TECHNOLOGY, WEAPONRY, AND NATIONAL DEF↗

Towards non-contact pollution monitoring in sewers with hyperspectral imaging

Monitoring water quality in sewers is challenging, particularly because state-of-the-art technologies require contact with the raw wastewater. The presence of fat, oil, grease, and solids makes automated grab sampling difficult and causes sensor fouling. To overcome these limitations, non-contact methods based on light reflectance, such as hyperspectral imaging (HSI), are gaining attention. However, HSI has never been tested for raw wastewater. To assess its accuracy for measuring pollution, we developed a laboratory setup and performed targeted experiments with a combination of raw and diluted wastewater, as well as synthetic turbidity stock solutions. We measured seven pollution variables: chemical oxygen demand, turbidity, dissolved organic compounds, ammonium, total nitrogen, phosphate, and sulphates. We used automated pixel selection and partial least squares regression to retrieve pollution information from the hyperspectral images. Our results, based on 144 samples, suggest that HSI can estimate pollution levels with a precision in the range of state-of-the-art absorbance spectrophotometric methods. Additionally, we found that the combination of pixel and wavelength selection, enabled by the hyperspectral data structure, significantly influences the performance of partial least square modelling. Overall, our findings indicate that HSI is a promising technology for non-contact monitoring of water quality in raw wastewater.

54 ENVIRONMENTAL SCIENCES↗

Selected micrometeorological and soil data from the Manaus ZF2 K34 eddy covariance tower for the 2015/16 El Niño event

The K34 tower site (2.609 S, 60.209 W, 130 masl), located within the Tropical Silviculture Experimental Station (EEST, also known as ZF2) research station, in an area of undisturbed tropical forest (Araújo et al. 2002). It features long term measurements using micrometeorological, eddy covariance, and soil instrumentation, among others. This dataset covers January 2012 to December 2017, and includes air temperature (TA, ℃) and air relative humidity (RH, %), measured with thermohygrometers (HC2S3, Campbell Scientific, Logan, UT, USA) deployed above the canopy at the top of the tower (at 51.1 m height), and net radiation (NETRAD, W m-2) using an NR-LITE sensor (Kipp & Zonen, Delft, Netherlands), also at the top of the tower (at 35.0 m above the canopy). The soil moisture data included here is from a soil profile located approximately 12 m from the tower, and covers the period between February 2015 and September 2016. Volumetric soil water content (SWC, m3 m-3) measurements used Water Content Reflectometers (CS655 Campbell Scientific, Logan, UT, USA) at six depths: 10 cm, 20 cm, 30 cm, 40 cm, 60 cm, and 100 cm. Data are included in .csv files, and the text file ZF2-K34_Tower_headers.txt provides descriptions of data file headers.

54 ENVIRONMENTAL SCIENCES↗

Size control of nanopores formed on SiO{sub 2} glass by swift-heavy-ion irradiation and its application to highly sensitive biomolecular detection

Swift-heavy-ion irradiation creates latent tracks in SiO{sub 2} glass and nanopores with a high aspect ratio can be formed along these ion paths by selective etching of the latent tracks using hydrogen fluoride (HF) vapor. Here we report that the size of nanopores can easily be controlled by simply changing the temperature of the HF solution generating the vapor and/or that of the SiO{sub 2} glass exposed to the vapor. Furthermore, this method of size control was used to produce SiO{sub 2} glass sheets with nanopores of different sizes and number densities for use as the waveguide layer in the sensing plates for a waveguide-mode sensor. In comparison with nonperforated plates, the increased surface area due to the formation of nanopores was found to create up to a tenfold increase in sensitivity.

36 MATERIALS SCIENCE↗

Model-based Hierarchical Reinforcement Learning for Improved Physical Security Design: A Prototype

Prior work in FY24 developed an adversarial AI agent aid in path analysis of physical protection systems. This agent, trained using a model-based reinforcement learning algorithm, was able to successfully learn the most vulnerable path in facilities. It was able to extend the current state of practice for physical protection design by exhibiting dynamic behavior based on current environmental conditions. Whereas PathTrace largely performs a static, graph-based analysis, the AI agent was able to make decisions based on relative position in the facility, current conditions (was the adversarial agnet discovered?), and proximity to secondary targets. The agent demonstrated some novel capabilities, but had limitations that need to be resolved before it can be used for production purposes. For example, the adversarial agent generalizes poorly and takes a relatively long time to train. Nonetheless, there is still considerable promise for developing the adversarial agent further in order to explore even richer, more dynamic behaviors (e.g., adversary motivations, environmental debris, and more). This work considers a complementary idea; development of a planning agent. The planning agent is envisioned as an auto-complete-like tool that can help accelerate security system design by human experts. The agent would respect existing barriers and sensors placed by a human expert while offering cost-effective suggestions (i.e., implicitly balancing effectiveness with cost) to improve the design. The goal is for this agent to be part of an expert’s toolbox, not to totally upend the current state-of-practice, or to displace human experts. The ultimate goal would be concurrent training of both the adversarial and planning agent together, to learn entirely through self-play. This would represent an entirely new way of performing system deign. We selected a hierarchical, model-based reinforcement learning algorithm to serve as the planning agent. This is an extension of concepts used in the prior FY24 adversarial agent work. There, we had a single agent acting an environment. Here, we have two different sub-agents (policies), working together, to form a complete agent. There is a manager policy, which can select abstract goals on slower time scales, and a worker, which performs primitive actions to reach goals selected by the manager. It is worth noting that this class of algorithm is challenging to work with. From our understanding, our work is one of the first successful uses of model-based reinforcement learning (MBRL) in nuclear energy1 , and likely the first hierarchical model-based reinforcement learning application in nuclear energy. Further, this work is one of the first known attempts to apply AI to perform a design tasks in nuclear energy. Consequently, there were significant implementation challenges and the bulk of the work was focused on successful implementation and algorithm design. The results presented here are very low technology readiness level as a consequence of the lack of related literature, but still represent a significant step forward in the pursuit of applied AI for design.

42 ENGINEERING↗

The Effect of Degraded Digital Instrumentation and Control systems on Human-system Interfaces and Operator Performance

Integrated digital instrumentation and control (I&C) systems in new and advanced nuclear power plants (NPPs) will support operators in monitoring and controlling the plants. Even though digital systems typically are expected to be reliable, their potential for degradation or failure significantly could affect the operators performance and, consequently, jeopardize plant safety. This U.S. Nuclear Regulatory Commission (NRC) research investigated the effects of degraded I&C systems on human performance and on plant operations. The objective was to develop technical basis and guidance for human factors engineering (HFE) reviews addressing the operator's ability to detect and manage degraded digital I&C conditions. We reviewed pertinent standards and guidelines, empirical studies, and plant operating experience. In addition, we evaluated the potential effects of selected failure modes of the digital feedwater control system of a currently operating pressurized water reactor (PWR) on human-system interfaces (HSIs) and the operators performance. Our findings indicated that I&C degradations are prevalent in plants employing digital systems, and the overall effects on the plant's behavior can be significant, such as causing a reactor trip or equipment to operate unexpectedly. I&C degradations may affect the HSIs used by operators to monitor and control the plant. For example, deterioration of the sensors can complicate the operators interpretation of displays, and sometimes may mislead them by making it appear that a process disturbance has occurred. We used the findings as the technical basis upon which to develop HFE review guidance.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

A data-driven approach to sampling matrix selection for compressive sensing

Sampling is a fundamental aspect of any implementation of compressive sensing. Typically, the choice of sampling method is guided by the reconstruction basis. However, this approach can be problematic with respect to certain hardware constraints and is not responsive to domain-specific context. We propose a method for defining an order for a sampling basis that is optimal with respect to capturing variance in data, thus allowing for meaningful sensing at any desired level of compression. We focus on the Walsh-Hadamard sampling basis for its relevance to hardware constraints, but our approach applies to any sampling basis of interest. We illustrate the effectiveness of our method on the Physical Sciences Inc. Fabry-Perot interferometer sensor multispectral dataset, the Johns Hopkins Applied Physics Lab FTIR-based longwave infrared sensor hyperspectral dataset, and a Colorado State University Swiss Ranger depth image dataset. The spectral datasets consist of simulant experiments, including releases of chemicals such as GAA and SF6. We combine our sampling and reconstruction with the adaptive coherence estimator (ACE) and bulk coherence for chemical detection and we incorporate an algorithmic threshold for ACE values to determine the presence or absence of a chemical. We compare results across sampling methods in this context. We have successful chemical detection at a compression rate of 90%. For all three datasets, we compare our sampling approach to standard orderings of sampling basis such as random, sequency, and an analog of sequency that we term `frequency.' In one instance, the peak signal to noise ratio was improved by over 30% across a test set of depth images.

compressive sensing, hyperspectral imaging, Walsh-↗

Virtual sensor supervised learning for cyber-attack neutralization

An industrial asset may have monitoring nodes that generate current monitoring node values. A dynamic, resilient estimator may split a temporal monitoring node space into normal and one or more abnormal subspaces associated with different kinds of attack vectors. According to some embodiments, a neutralization model is constructed and trained for each attack vector using supervised learning and the associated abnormal subspace. In other embodiments, a single model is created using out-of-range values for abnormal monitoring nodes. Responsive to an indication of a particular abnormal monitoring node or nodes, the system may automatically invoke the appropriate neutralization model to determine estimated values of the particular abnormal monitoring node or nodes (e.g., by selecting the correct model or using out-of-range values). The series of current monitoring node values from the abnormal monitoring node or nodes may then be replaced with the estimated values.

97 MATHEMATICS AND COMPUTING↗

Construction of a Novel Zn₋Ni Trinuclear Schiff Base and a Ni 2+ Chemosensor

The novel Schiff base Zn-Ni trinuclear complex (Zn[Ni(sy- L 2 )]2(SCN) 2 , where sy-H 2 L 2 = H 2 acacen = bis(acetylacetone)ethylenediamine), which is the first trinuclear compound based on symmetric acacen-base Schiff base ligand, was constructed through Ni2 + -selective assembly of chemosensor Schiff base zinc compound Zn[(sy-H 2 L 2 )(SCN)] 2 ∙(CH 3 CN) 2 .

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

MetricForensics: A Multi-Level Approach for Mining Volatile Graphs

Advances in data collection and storage capacity have made it increasingly possible to collect highly volatile graph data for analysis. Existing graph analysis techniques are not appropriate for such data, especially in cases where streaming or near-real-time results are required. An example that has drawn significant research interest is the cyber-security domain, where internet communication traces are collected and real-time discovery of events, behaviors, patterns and anomalies is desired. We propose MetricForensics, a scalable framework for analysis of volatile graphs. MetricForensics combines a multi-level “drill down" approach, a collection of user-selected graph metrics and a collection of analysis techniques. At each successive level, more sophisticated metrics are computed and the graph is viewed at a finer temporal resolution. In this way, MetricForensics scales to highly volatile graphs by only allocating resources for computationally expensive analysis when an interesting event is discovered at a coarser resolution first. We test MetricForensics on three real-world graphs: an enterprise IP trace, a trace of legitimate and malicious network traffic from a research institution, and the MIT Reality Mining proximity sensor data. Our largest graph has »3M vertices and »32M edges, spanning 4:5 days. The results demonstrate the scalability and capability of MetricForensics in analyzing volatile graphs; and highlight four novel phenomena in such graphs: elbows, broken correlations, prolonged spikes, and strange stars.

96 KNOWLEDGE MANAGEMENT AND PRESERVATION↗

Active Learning for Anomaly Detection in Environmental data

Due to the growing amount of data from in-situ sensors in environmental monitoring, it becomes necessary to automatically detect anomalous data points. Nowadays, this is mainly performed using supervised machine learning models, which need a fully labelled data set for their training process. However, the process of labelling data is typically cumbersome and, as a result, a hindrance to the adoption of machine learning methods for automated anomaly detection. In this work, we propose to address this challenge by means of active learning. This method consists of querying the domain expert for the labels of only a selected subset of the full data set. We show that this reduces the time and costs associated to labelling while delivering the same or similar anomaly detection performances. Finally, we also show that machine learning models providing a nonlinear classification boundary are to be recommended for anomaly detection in complex environmental data sets.

54 ENVIRONMENTAL SCIENCES↗

Technical Needs for Prototypic Prognostic Technique Demonstration for Advanced Small Modular Reactor Passive Components

This report identifies a number of requirements for prognostics health management of passive systems in AdvSMRs, documents technical gaps in establishing a prototypical prognostic methodology for this purpose, and describes a preliminary research plan for addressing these technical gaps. AdvSMRs span multiple concepts; therefore a technology- and design-neutral approach is taken, with the focus being on characteristics that are likely to be common to all or several AdvSMR concepts. An evaluation of available literature is used to identify proposed concepts for AdvSMRs along with likely operational characteristics. Available operating experience of advanced reactors is used in identifying passive components that may be subject to degradation, materials likely to be used for these components, and potential modes of degradation of these components. This information helps in assessing measurement needs for PHM systems, as well as defining functional requirements of PHM systems. An assessment of current state-of-the-art approaches to measurements, sensors and instrumentation, diagnostics and prognostics is also documented. This state-of-the-art evaluation, combined with the requirements, may be used to identify technical gaps and research needs in the development, evaluation, and deployment of PHM systems for AdvSMRs. A preliminary research plan to address high-priority research needs for the deployment of PHM systems to AdvSMRs is described, with the objective being the demonstration of prototypic prognostics technology for passive components in AdvSMRs. Greater efficiency in achieving this objective can be gained through judicious selection of materials and degradation modes that are relevant to proposed AdvSMR concepts, and for which significant knowledge already exists. These selections were made based on multiple constraints including the analysis performed in this document, ready access to laboratory-scale facilities for materials testing and measurement, and potential synergies with other national laboratory and university partners.

Advanced Small Modular Reactors↗

Structural Evolution of Mixed-Addenda Keggin Polyoxometalate Anions with Atom-by-Atom Substitution

Polyoxometalates (POMs) are molecular metal oxides with distinctive electronic properties that make them promising materials for applications in energy, sensors, and memory devices. One of the most promising methods of tuning the stability, photochromic, redox, and electron-spin properties of POMs is through the substitution of the metal “addenda” atoms that, along with oxygen, constitute their cage-like structures. Because traditional synthesis methods typically produce a distribution of POMs, the isolation and characterization of multimetallic POMs with predetermined stoichiometry remains challenging. The presence of multiple energetically accessible isomers further complicates the experimental characterization and theoretical modeling of multimetallic POMs. Herein, we leverage the distinguishing mass-selection capabilities of ion soft landing to prepare stoichiometrically selected Keggin PMo x W 12-x O 40 3- (x = 0 – 6, 8, 10, and 12) POMs on self-assembled monolayer surfaces free of the solvent molecules and counterions that often confound characterization of complex species at interfaces. The structures of the supported POMs are characterized with atom-by-atom precision using in situ infrared (IR) reflection absorption spectroscopy complemented by detailed density functional theory calculations. Our joint experimental and theoretical results reveal an almost linear shift in the positions of the IR bands towards lower wavenumbers with an increase in the number of lighter molybdenum atoms compared to heavier W atoms in PMoxW 12-x O 40 3- . The theoretical calculations also indicate that numerous isomeric structures may be populated at the experimental conditions and, consequently, contribute to the overall IR spectra. In conclusion, our findings indicate that in addition to the number of substituted addenda atoms and the presence of multiple isomeric structures, interactions with the surface play an important role in determining the IR spectra and structure of supported bimetallic POMs.

Prabhakaran, Venkateshkumar [Pacific Northwest Nat↗

Electrodermal activity as a proxy for sweat rate monitoring during physical and mental activities

Electrodermal activity has long been used for mental activity monitoring by measuring skin conductance at specific locations, such as fingertips, with high sweat gland density. However, electrodermal activity has not been considered useful for physical activity monitoring, where large sweat volumes are generated, resulting in the accumulation of sweat at the skin–electrode interface and, thus, preventing further dynamic response to sweating events. Here we show that electrodermal activity can be used as a proxy for sweat loss measurement under both low and high physical activity levels. We use wearable sweat sensors that consist of water-permeable electrodes and microfluidic-based sweat analysers, and show that skin conductance is proportional to the instantaneous sweat loss. We demonstrate that sweat loss during exercise can be estimated by integrating skin conductance over time, which can be applied to assess the body hydration status of exercisers. From multisite measurements of skin conductance, we show that the wrist, forearm and upper arm are reflective of physical activity levels, whereas the finger is indicative of mental activity. Simultaneous measurement of two different sites selectively decouples mental and physical activities.

Biomedical engineering↗

Use-dependent block of the voltage-gated Na + channel by tetrodotoxin and saxitoxin: Effect of pore mutations that change ionic selectivity

Voltage-gated Na + channels (NaV channels) are specifically blocked by guanidinium toxins such as tetrodotoxin (TTX) and saxitoxin (STX) with nanomolar to micromolar affinity depending on key amino acid substitutions in the outer vestibule of the channel that vary with NaV gene isoforms. All NaV channels that have been studied exhibit a use-dependent enhancement of TTX/STX affinity when the channel is stimulated with brief repetitive voltage depolarizations from a hyperpolarized starting voltage. Two models have been proposed to explain the mechanism of TTX/STX use dependence: a conformational mechanism and a trapped ion mechanism. In this study, we used selectivity filter mutations (K1237R, K1237A, and K1237H) of the rat muscle NaV1.4 channel that are known to alter ionic selectivity and Ca 2+ permeability to test the trapped ion mechanism, which attributes use-dependent enhancement of toxin affinity to electrostatic repulsion between the bound toxin and Ca 2+ or Na + ions trapped inside the channel vestibule in the closed state. Our results indicate that TTX/STX use dependence is not relieved by mutations that enhance Ca 2+ permeability, suggesting that ion–toxin repulsion is not the primary factor that determines use dependence. Evidence now favors the idea that TTX/STX use dependence arises from conformational coupling of the voltage sensor domain or domains with residues in the toxin-binding site that are also involved in slow inactivation.

60 APPLIED LIFE SCIENCES↗

Silicon Carbide Temperature Monitor Measurements at the High Temperature Test Laboratory

Silicon carbide (SiC) temperature monitors are now available for use as temperature sensors in Advanced Test Reactor (ATR) irradiation test capsules. Melt wires or paint spots, which are typically used as temperature sensors in ATR static capsules, are limited in that they can only detect whether a single temperature is or is not exceeded. SiC monitors are advantageous because a single monitor can be used to detect for a range of temperatures that may have occurred during irradiation. As part of the efforts initiated by the ATR National Scientific User Facility (NSUF) to make SiC temperature monitors available, a capability was developed to complete post-irradiation evaluations of these monitors. As discussed in this report, the Idaho National Laboratory (INL) selected the resistance measurement approach for detecting peak irradiation temperature from SiC temperature monitors. This document describes the INL efforts to develop the capability to complete these resistance measurements. In addition, the procedure is reported that was developed to assure that high quality measurements are made in a consistent fashion.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗