Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “sensor array”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,135 records · Page 63

Status of NASA Goddard Space Flight Center's Participation in SNAP

Dr. Rauscher will present programatic status and high-level/summary information on the technical status of NASA Goddard Space Flight Center's participation in the SuperNova Acceleration Probe (SNAP). Goddard's participation falls into four areas, and status in each of these will be covered. These areas are as follows: (I) focal plane array and packaging, (2) Teledyne HAWAII-4RG sensor chip assembly, (3) communications studies, and (4) integration and test studies.

Rauscher, Bernard↗

The Primordial Inflation Polarization Explorer (PIPER)

The Primordial Inflation Polarization Explorer (PIPER) is a balloon-borne experiment designed to search for the polarized imprint of gravitational waves from cosmic inflation. The discovery of such a signal would provide direct evidence for inflation, and its characterization would provide a means to explore energy scales orders of magnitude larger than any conceivable particle accelerator. PIPER will consist of two cryogenic telescopes-one for each of the Q and U Stokes parameters. Each will use a variable-delay polarization modulator (VPM) as its first element. This architecture is designed to minimize both T->B and E->B systematics. The detectors will be four 32x40 arrays of BUG detectors, utilizing transition-edge sensors and time-domain multiplexing. Each flight will observe approximately 25% of the sky at a single frequency. Additional flights will increase the frequency coverage.

Chuss, David T.↗

Thermocooling of GMR Sensors

A thermoelectrically cooled GMR sensor having a first thermoelectric layer with an array of nanowires, wherein the nanowires include a diameter of about 1 nanometer to about 1000 nanometers. A plurality of alternating layers of magnetic and nonmagnetic material are positioned over and extend the nanowires to form a GMR assembly. A second thermoelectric layer is positioned over the GMR assembly and extends the nanowires, such that the nanowires have a length of between about 100 nanometers and about 500 microns. Conductors are placed in contact with the first and second thermoelectric layers for connecting the thermoelectric layers to a voltage source.

Davis, Despina↗

Kepler Instrument Performance: An In-Flight Update

The Kepler Mission is designed to detect the 80 parts per million (ppm) signal from an Earth-Sun equivalent transit. Such precision requires superb instrument stability on time scales up to 2 days and systematic error removal to better than 20 ppm. The sole scientic instrument is the Photometer, a 0.95 m aperture Schmidt telescope that feeds the 94.6 million pixel CCD detector array, which contains both Science and Fine Guidance Sensor (FGS) CCDs. Since Kepler's launch in March 2009, we have been using the commissioning and science operations data to characterize the instrument and monitor its performance. We find that the in-flight detector properties of the focal plane, including bias levels, read noise, gain, linearity, saturation, FGS to Science crosstalk,and video crosstalk between Science CCDs, are essentially unchanged from their pre-launch values. Kepler'sunprecedented sensitivity and stability in space have allowed us to measure both short- and long- term effects from cosmic rays, see interactions of previously known image artifacts with starlight, and uncover several unexpected systematics that affect photometric precision. Based on these results, we expect to attain Kepler's planned photometric precision over 90% of the field of view.

CCD↗

Next Generation Millimeter-Wave Radar for Safe Planetary Landing

Safe, precise landing on planetary bodies requires knowledge of altitude and velocity, and may require active detection and avoidance of hazardous terrain. Radar offers a superior solution to both problems due to its ability to operate at any time of day, through dust and engine plumes, and ability to detect velocity coherently. While previous efforts have focused on providing near term solutions to the safe landing problem, we are designing radar velocimeters and radar imagers for missions beyond the next decade. In this paper we identify the fundamental issues within each approach, at arrive at strawman sensor designs at a center frequency at or around 160 GHz (Gband). We find that a G-band radar velocimeter design is capable of sub-10 cm/s accuracy, and a G-band imager is capable of sub-0.5 degree resolution over a 28 degree field of view. From those designs, we arrive at the key technology requirements for the development of power and low noise amplifiers, signal distribution methods, and antenna arrays that enable the construction of these next generation sensors.

radar velocimetry↗

Acoustic Observations of the OSIRIS-REx Sample Return Capsule Re-Entry from Wendover Airport

The Origins, Spectral Interpretation, Resource Identification, and Security‐Regolith Explorer sample return capsule (SRC) re‐entered the Earth’s atmosphere at hypersonic speeds from interplanetary space on 24 September 2023. The current work reports on 18 ground‐based acoustic sensors deployed at Wendover Airport, the same location that the Genesis and Stardust SRC re‐entries were recorded. Four different sensors (Chaparral Physics, Gem, Wilson Engineering Research and Development [WERD], and RedVox) were deployed in close proximity to compare their performance. All the sensors captured an N‐wave signal associated with the SRC re‐entry shock wave followed by a broadband coda. The Chaparral Physics array served as the high‐fidelity reference measurement. The N‐wave signal had a peak‐to‐peak amplitude of 4.07 Pa with a fundamental frequency of 4.98 Hz from 167.5° measured clockwise from north, nearly perpendicular to the SRC trajectory. In addition, high coherence in the coda was shown to be associated reflections from the surrounding mountains. In general, the more economical sensors (Gem, WERD, and RedVox) produced results that were consistent with these observations and sensor specifications. Beamforming with these single sensors arranged as an array showed agreement with the high‐fidelity array to within a couple of degrees. Furthermore, the current high‐fidelity results were compared with the measurements during the Genesis and Stardust SRC re‐entries. All three entries produced a broadband fundamental peak at a frequency that was inversely related to the SRC diameter as well as evidence of reflections from the surrounding topography.

KC, Real J. [Oklahoma State University, Stillwater↗

Toward Fully Soft and Multifunctional Shape Sensing via Optical Waveguide Arrays

For soft bodies, surface deformation and pressure provide proprioceptive and exteroceptive information, including body configuration, body compliance, and external forces. We develop a sheet sensor with a fully soft sensing surface that provides surface shape reconstruction using optical waveguide arrays. The waveguides are fabricated to achieve a tunable linear response to bi‐directional bending curvature, and the waveguide arrays are configured to differentiate between ambiguous shapes. We characterize the waveguide performance, relating curvature sensitivity to the core's surface roughness. Synergy of waveguide responses reduces the number of sensing elements required and achieves damage resilience. Using waveguide sensitivity to pressure, we also demonstrate feasibility for exteroception. We demonstrate the multifunctional sensing capability by wrapping the sheet around an upper arm, showcasing joint motion and external force sensing. Integrated into or applied onto surfaces of robotic or living systems, this design can be implemented in applications such as virtual reality, teleoperation, physical therapy, and soft robotics.

Yu, Qifan [Department of Mechanical Engineering Ma↗

Design, Fabrication, and Characterization of a Piezoelectric AFM Cantilever Array

Atomic force microscope (AFM) is a powerful instrument, which has been successfully employed in a myriad of applications from imaging to lithography, over the last decades. Despite its widespread use, low throughput of the AFM remains one of its major limitations along with slow scan rates in tapping mode. In this work, we propose a microfabricated cantilever array composed of five cantilevers, each equipped with onchip piezoelectric displacement sensors and an actuator for parallel imaging in tapping mode. The cantilevers are designed to have separate resonance frequencies in order to effectively minimize the vibrational coupling. The measured resonance frequencies range from 85.34 kHz to 107.78 kHz, and more than 5 kHz resonant frequency separation is achieved in the neighboring cantilevers. Vibrational coupling is mitigated by over two orders of magnitude compared to arrays with identical cantilevers. The common feedthrough problem in this type of active system is addressed by configuring the displacement sensors differentially. Finally, one of the cantilevers in the arrayis successfully employed for tapping mode AFM imaging.

42 ENGINEERING↗

An Overview of 2014 SBIR Phase 1 and Phase 2 Communications Technology and Development

NASA's Small Business Innovation Research (SBIR) program focuses on technological innovation by investing in development of innovative concepts and technologies to help NASA mission directorates address critical research needs for Agency programs. This report highlights eight of the innovative SBIR 2014 Phase I and Phase II projects that emphasize one of NASA Glenn Research Center's six core competencies-Communication Technology and Development. The technologies cover a wide spectrum of applications such as X-ray navigation, microsensor instrument for unmanned aerial vehicle airborne atmospheric measurements, 16-element graphene-based phased array antenna system, interferometric star tracker, ultralow power fast-response sensor, and integrated spacecraft navigation and communication. Each featured technology describes an innovation, technical objective, and highlights NASA commercial and industrial applications. This report provides an opportunity for NASA engineers, researchers, and program managers to learn how NASA SBIR technologies could help their programs and projects, and lead to collaborations and partnerships between the small SBIR companies and NASA that would benefit both.

ultralow power fast-response sensor↗

Bifacial PV test-bed irradiance measurements

Data for 2 front-facing and 4 rear-facing IMT irradiance sensors placed on a scaled-down setup that replicate a PV array in a highly-reflective rooftop. The test-bed consist of 3 rows of 20x2ft aluminum sheets (the “panels”), supported by a Unistrut structure, with 6 irradiance sensors (IMT) measuring front and rear irradiance in the center module of the center row. High quality weather-station data available

14 SOLAR ENERGY↗

Large area CCD image sensors for space astronomy

The Defense Advanced Research Projects Agency (DARPA) has a substantial program to develop a 2200 x 2200 pixel CCD (Charge Coupled Device) mosaic array made up of 400 individual CCD's, 110 x 110 pixels square. This type of image sensor appeared to have application in space and ground-based astronomy. Under this grant a CCD television camera system was built which was capable of operating an array of 4 CCD's to explore the suitability of the CCD's to explore the suitability of the CCD for astronomical applications. Two individual packaged CCD's were received and evaluated. Evaluation of the basic characteristics of the best individual chips was encouraging, but the manufacturer found that their yield in manufacturing this design is two low to supply sufficient CDD's for the DARPA mosaic array. The potential utility of large mosaic arrays in astronomy is still substantial and continued monitoring of the manufacturers progress in the coming year is recommended.

Schwarzschild, M.↗

Ring-Interferometric Sol-Gel Bio-Sensor

A biosensor embodying the invention includes a sensing volume having an array of pores sized for immobilizing a first biological entity tending to bind to a second biological entity in such a manner as to change an index of refraction of the sensing volume. The biosensor further includes a ring interferometer, one volumetric section of the ring interferometer being the sensing volume, a laser for supplying light to the ring interferometer, and a photodetector for receiving light from the interferometer.

Bearman, Gregory↗

Helical Photonic Metamaterials for Encrypted Chiral Holograms

Helical structures are among the most quintessential three-dimensional (3D) forms that exhibit mirror asymmetry, a hallmark of chirality. Various structural parameters of helices directly linked to chiroptical properties highlight their importance as essential optical metamaterials for polarization-resolved sensors, imaging, and spectroscopies. However, such function-defining properties remain incompletely understood due to fabrication challenges and the lack of a relationship between structure and optical properties. Here, helical structures are analyzed parametrically, and correlations are established that are applicable to the design of chiral helical optical metamaterials. By systematically varying independent parameters—such as from single-turn to five-turn helices and from small major radii to larger ones optimized to fit the unit cell—the underlying relationships with ellipticty are revealed. In addition to theoretical modeling, the findings are experimentally validated using 3D printing and terahertz spectroscopy. The results demonstrate that optimized helical structures are mechanically tunable and exhibit unprecedented optical properties, including broadband and high-magnitude ellipticity spectra. Being embedded in soft elastomers, helical arrays can serve as soft, stretchable optical-mechanical sensors and holograms containing encoded information, such as barcodes and quick response (QR) codes. Chiral QR codes are realized using pixelated single helices with different handedness, demonstrating their potential as advanced encryption/decryption systems for security applications and chiral metaholograms.

Encrypted QR codes↗

Sub-micron surface plasmon resonance sensor systems

A sensor for detecting the presence of a target analyte, ligand or molecule in a test fluid, comprising a light transmissive substrate on which an array of surface plasmon resonant (SPR) elements is mounted is described. A multichannel sensor for detecting the presence of several targets with a single microchip sensor is described. A multichannel sensor including collections of SPR elements which are commonly functionalized to one of several targets is also described. The detectors sense changes in the resonant response of the SPR elements indicative of binding with the targets.

Glazier, James A.↗

A Portable 16-channel Magnetic Sensor for Human Magnetocardiographic Experiments

Here, we constructed a portable, low-cost 16-channel magnetic sensor for magnetocardiography (MCG) applications. The sensor is based on a high-sensitivity optically pumped magnetometer (OPM) with a novel configuration of nearly parallel pump and probe laser beams. The OPM-based 16-channel magnetic sensing is realized in a single module by using a fairly large rubidium vapor cell, broad pump/probe laser beams, and a 16-channel photodiode array, leading projected 10-fold reduction of the cost of sensors. The portability of the sensor is achieved by coupling the pump and probe lasers to OPM optics through multi-mode optical fibers. The 16-channel magnetic sensor is surrounded by a non-magnetic enclosure for safe operation. For MCG experiments with the sensor, its main components except lasers are located inside a magnetically shielded room (MSR), which reduces the ambient magnetic noise. The location of lasers and supporting electronics outside the MSR improves the sensitivity of the sensor. We report that the 16-channel magnetic sensor has a magnetic field sensitivity sufficient to directly detect the human cardiac magnetic signals.

16-channel magnetic sensing↗

Performance Analysis of a Cost-Effective Electret Condenser Microphone Directional Array

Microphone directional array technology continues to be a critical part of the overall instrumentation suite for experimental aeroacoustics. Unfortunately, high sensor cost remains one of the limiting factors in the construction of very high-density arrays (i.e., arrays containing several hundred channels or more) which could be used to implement advanced beamforming algorithms. In an effort to reduce the implementation cost of such arrays, the authors have undertaken a systematic performance analysis of a prototype 35-microphone array populated with commercial electret condenser microphones. An ensemble of microphones coupling commercially available electret cartridges with passive signal conditioning circuitry was fabricated for use with the Langley Large Aperture Directional Array (LADA). A performance analysis consisting of three phases was then performed: (1) characterize the acoustic response of the microphones via laboratory testing and calibration, (2) evaluate the beamforming capability of the electret-based LADA using a series of independently controlled point sources in an anechoic environment, and (3) demonstrate the utility of an electret-based directional array in a real-world application, in this case a cold flow jet operating at high subsonic velocities. The results of the investigation revealed a microphone frequency response suitable for directional array use over a range of 250 Hz - 40 kHz, a successful beamforming evaluation using the electret-populated LADA to measure simple point sources at frequencies up to 20 kHz, and a successful demonstration using the array to measure noise generated by the cold flow jet. This paper presents an overview of the tests conducted along with sample data obtained from those tests.

Humphreys, William M., Jr.↗