Vibration and Resonance Behavior of Back-to-Back Stirling-Cycle Cryocoolers
Explore the source record for details and available documents.
SEARCH · Engineering Papers
Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.
Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.
Explore the source record for details and available documents.
The Boltzmann-Ehrenfest principle of adiabatic invariance has been applied to a resonant microwave cavity containing a dielectric sphere.
An innovative method has been developed for acquiring fluid-level measurements. This method eliminates the need for the fluid-level sensor to have a physical connection to a power source or to data acquisition equipment. The complete system consists of a lightweight, thin-film magnetic-field-response fluid-level sensor (see Figure 1) and a magnetic field response recorder that was described in Magnetic-Field-Response Measurement-Acquisition System (LAR-16908-1), NASA Tech Briefs, Vol. 30, No. 6 (June 2006), page 28. The sensor circuit is a capacitor connected to an inductor. The response recorder powers the sensor using a series of oscillating magnetic fields. Once electrically active, the sensor responds with its own harmonic magnetic field. The sensor will oscillate at its resonant electrical frequency, which is dependent upon the capacitance and inductance values of the circuit.
The Mars Organic Mass Analyzer is being developed at Goddard Space Flight Center to identify organics and possible biological compounds on Mars. In the process of characterizing mass spectrometer size, weight, and power consumption, the use of pulse counting was considered for ion detection. Pulse counting has advantages over analog-mode amplification of the electron multiplier signal. Some advantages are reduced size of electronic components, low power consumption, ability to remotely characterize detector performance, and avoidance of analog circuit noise. The use of pulse counting as a detection method with ion trap instruments is relatively rare. However, with the recent development of high performance electrical components, this detection method is quite suitable and can demonstrate significant advantages over analog methods. Methods A prototype quadrupole ion trap mass spectrometer with an internal electron ionization source was used as a test setup to develop and evaluate the pulse-counting method. The anode signal from the electron multiplier was preamplified. The an1plified signal was fed into a fast comparator for pulse-level discrimination. The output of the comparator was fed directly into a Xilinx FPGA development board. Verilog HDL software was written to bin the counts at user-selectable intervals. This system was able to count pulses at rates in the GHz range. The stored ion count nun1ber per bin was transferred to custom ion trap control software. Pulse-counting mass spectra were compared with mass spectra obtained using the standard analog-mode ion detection. Prelin1inary Data Preliminary mass spectra have been obtained for both analog mode and pulse-counting mode under several sets of instrument operating conditions. Comparison of the spectra revealed better peak shapes for pulse-counting mode. Noise levels are as good as, or better than, analog-mode detection noise levels. To artificially force ion pile-up conditions, the ion trap was overfilled and ions were ejected at very high scan rates. Pile-up of ions was not significant for the ion trap under investigation even though the ions are ejected in so-called 'ion-micro packets'. It was found that pulse counting mode had higher dynamic range than analog mode, and that the first amplification stage in analog mode can distort mass peaks. The inherent speed of the pulse counting method also proved to be beneficial to ion trap operation and ion ejection characterization. Very high scan rates were possible with pulse counting since the digital circuitry response time is so much smaller than with the analog method. Careful investigation of the pulse-counting data also allowed observation of the applied resonant ejection frequency during mass analysis. Ejection of ion micro packets could be clearly observed in the binned data. A second oscillation frequency, much lower than the secular frequency, was also observed. Such an effect was earlier attributed to the oscillation of the total plasma cloud in the ion trap. While the components used to implement pulse counting are quite advanced, due to their prevalence in consumer electronics, the cost of this detection system is no more than that of an analog mode system. Total pulse-counting detection system electronics cost is under $250
A vacuum compressor has been designed to compress CO2 from approximately equal to 1 psia (approximately equal to 6.9 kPa absolute pressure) to approximately equal to 75 psia (approximately equal to 0.52 MPa), to be insensitive to moisture, to have a long operational life, and to be lightweight, compact, and efficient. The compressor consists mainly of (1) a compression head that includes hydraulic diaphragms, a gas-compression diaphragm, and check valves; and (2) oscillating linear drive that includes a linear motor and a drive spring, through which compression force is applied to the hydraulic diaphragms. The motor is driven at the resonance vibrational frequency of the motor/spring/compression-head system, the compression head acting as a damper that takes energy out of the oscillation. The net effect of the oscillation is to cause cyclic expansion and contraction of the gas-compression diaphragm, and, hence, of the volume bounded by this diaphragm. One-way check valves admit gas into this volume from the low-pressure side during expansion and allow the gas to flow out to the high-pressure side during contraction. Fatigue data and the results of diaphragm stress calculations have been interpreted as signifying that the compressor can be expected to have an operational life of greater than 30 years with a confidence level of 99.9 percent.
A magnetic tunnel junction (MTJ)-based microwave detector is proposed and investigated. When the MTJ is excited by microwave magnetic fields, the relative angle between the free layer and pinned layer alternates, giving rise to an average resistance change. By measuring the average resistance change, the MTJ can be utilized as a microwave power sensor. Due to the nature of ferromagnetic resonance, the frequency of an incident microwave is directly determined. In addition, by integrating a mixer circuit, the MTJ-based microwave detector can also determine the relative phase between two microwave signals. Thus, the MTJbased microwave detector can be used as an on-chip microwave phase and spectrum analyzer.
A magnetic tunnel junction (MTJ)-based microwave detector is proposed and investigated. When the MTJ is excited by microwave magnetic fields, the relative angle between the free layer and pinned layer alternates, giving rise to an average resistance change. By measuring the average resistance change, the MTJ can be utilized as a microwave power sensor. Due to the nature of ferromagnetic resonance, the frequency of an incident microwave is directly determined. In addition, by integrating a mixer circuit, the MTJ-based microwave detector can also determine the relative phase between two microwave signals. Thus, the MTJ-based microwave detector can be used as an on-chip microwave phase and spectrum analyzer.
We present a formulation of the Finite Element Method particular to axisymmetric problems containing anisotropic media.
Jefferson Lab is actively exploring the environmental applications of compact irradiation facilities utilizing Superconducting Radio Frequency (SRF) accelerator technology ? a well-established technology primarily used in large research machines. Recent advancements, such as the application of thin films of superconducting alloys in radio frequency (RF) resonators and the development of high-capacity cryocoolers, have made it feasible to employ this key technology in compact, standalone irradiation facilities. The main advantage over conventional systems based on normal conducting technology is the significantly enhanced efficiency in beam power generation, enabling exposure to substantially higher radiation doses. In the realm of addressing contaminants in wastewater treatment, particularly concerning persistent substances known as "forever chemicals," this technology presents an attractive solution, given the required considerable effort i.e. dose to break them down. Experiment Numbers:
The dispersion curves have been computed for a wide range of wavelengths from electromagnetic waves to electrostatic waves in a magnetoactive warm plasma with a Maxwellian velocity distribution function. The computation was carried out mainly for the perpendicular propagation mode. The upper hybrid resonance is the connection point of the electrostatic waves and the electromagnetic waves. The electrostatic waves not associated with the upper hybrid resonance are subjected to electron cyclotron damping when the wavelength becomes long. Oblique propagation is allowed for the electrostatic waves in a frequency range from the plasma frequency to the upper hybrid resonance frequency in the long-wavelength region where Landau damping can be neglected and where the electrostatic mode smoothly connects to the electromagnetic X-mode. In a slightly inhomogeneous plasma, the Bernstein-mode electrostatic wave can escape by being converted into the O-mode electromagnetic wave; two reflections take place during this escape process.
Small sapphire tuning wedge used in technique for solving mode-purity problem associated with sapphire dielectric-ring resonator part of cryogenic microwave frequency discriminator. Breaks quasi-degeneracy of two modes and allows selective coupling to just one mode. Wedge mounted on axle entering resonator cavity and rotated while resonator cryogenically operating in vacuum. Furthermore, axle moved vertically to tune resonant frequency.
Low-frequency superconducting lumped-element resonators have recently attracted significant attention in the context of axion dark matter searches. Here, we present the design and implementation of a fixed-frequency superconducting resonator operating near 250 kHz, possessing an inductor volume of ∼1 liter and achieving an unloaded quality factor Q ≈ 2.1 × 10 6 . This resonator represents a significant improvement over the state of the art and informs the design of searches for low-mass axions.
Low-frequency superconducting lumped-element resonators have recently attracted significant attention in the context of axion dark matter searches. Here we present the design and implementation of a fixed-frequency superconducting resonator operating near $250~\mathrm{kHz}$, possessing an inductor volume of $\sim 1$ liter and achieving an unloaded quality factor $Q \approx 2.1\times10^{6}$. This resonator represents a significant improvement over the state of the art and informs the design of searches for low-mass axions.
Testing technique is based on analysis of varying frequency scan applied to measured samples. Any changes in resonant-frequency harmonics detected in samples are used to indicate size of fault. Testing apparatus uses drive mechanism to apply vibrating force to sample. Force is applied longitudinally along axis to eliminate directionality on flexural vibrations.
Synthetic diamond dielectric bodies proposed for use in cylindrical resonators helping to stabilize frequencies of some microwave oscillators. Acting in conjunction with metal resonator cavities in which mounted, such dielectric bodies support "whispering-gallery" waveguide modes characterized by desired frequencies of resonance and by electro-magnetic-field configurations limiting dissipation of power on metal surfaces outside dielectric bodies. Performances at room temperature might exceed those of liquid-nitrogen-cooled sapphire-based resonators.
In the microgravity environment, the effect of gravity on fluid motion is much reduced. Hence, secondary effects such as vibrations, jitters, surface tension, capillary effects, and electromagnetic forces become the dominant mechanism of fluid convection. Numerous studies have been conducted to investigate fluid behavior in microgravity with the ultimate goal of developing processes with minimal influence from convection. Industrial applications such as crystal growth from solidification of melt and protein growth for pharmatheutical application are just a few examples of the vast potential benefit that can be reaped from material processing in space. However, a space laboratory is not immune from all undesirable disturbances and it is imperative that such disturbances be well understood, quantifiable, and controlled. Non-uniform and transient accelerations such as vibrations, jitters, and impulsive accelerations exist as a result of crew activities, space vehicle maneuvering, and the operations of on-board equipment. Measurements conducted on-board a U.S. Spacelab showed the existence of vibrations in the frequency range of 1 to 100 Hz with a dominant mode of 17 Hz and harmonics of 54 Hz. The observed vibration is not limited to any coordinate plane but exists in all directions. Similar situation exists on-board the Russian MIR space station. Due to the large structure of its design, the future International Space Station will have its own characteristic vibration spectrum. It is well known that vibration can exert substantial influence on heat and mass transfer processes, thus hindering any attempts to achieve a diffusion-limited process. Experiments on vibration convection for a liquid-filled enclosure under one-g environment showed the existence of different flow regimes as vibration frequency and intensity changes. Results showed the existence of a resonant frequency, near which the enhancement is the strongest, and the existence of a high frequency asymptote. Numerical simulations of vibration convection have been conducted by Yurkov, Fu and Shieh, and by Wang. These analyses considered a two-dimensional air-filled cell under weightlessness condition and showed results similar to those of the experiments. It is not yet known whether resonance convection can be triggered by jitter alone or whether it requires the interaction of jitter with other convective forces in low gravity. An order of magnitude analysis, however, can be used to show the dependence of the resonance frequency on the fluid Prandtl number. Even though the onset of resonance convection may depend on other factors, results indicates that fluids with low Prandtl numbers are more susceptible to resonance than those with high Prandtl numbers. The current study is aimed at gaining additional insights to this problem using germanium as working fluid. Germanium was chosen for this analysis because of its common usage in solidification process and its relatively low Prandtl number (Pr = 0.02).
The HWR (half-wave-resonator) cryomodule is the first one in the superconducting section of the PIP-II LINAC project at Fermilab. PIP-II IT is a test facility for the project where the injector, warm front-end, and the first two superconducting cryomodules are being tested. The HWR cryomodule comprises 8 cavities operating at a frequency of 162.5 MHz and accelerating beam up to 10 MeV. Resonance control of the cavities is performed with a pneumatically operated slow tuner which compresses the cavity at the beam ports. Helium gas pressure in a bellows mounted to an end wall of the cavity is controlled by two solenoid valves, one on the pressure side and one on the vacuum side. The resonant frequency of the cavity can be controlled in one of two modes. A pressure feedback control loop can hold the cavity tuner pressure at a fixed value for the desired resonant frequency. Alternately, the feedback loop can regulate the cavity tuner pressure to bring the RF detuning error to zero. The resonance controller is integrated into the LLRF control system for the cryomodule. The control system design and performance of the resonance control system are described in this paper.
Method and apparatus are provided for a non-invasive bubble measuring instrument operable for detecting, distinguishing, and counting gaseous embolisms such as bubbles over a selectable range of bubble sizes of interest. A selected measurement volume in which bubbles may be detected is insonified by two distinct frequencies from a pump transducer and an image transducer. respectively. The image transducer frequency is much higher than the pump transducer frequency. The relatively low-frequency pump signal is used to excite bubbles to resonate at a frequency related to their diameter. The image transducer is operated in a pulse-echo mode at a controllable repetition rate that transmits bursts of high-frequency ultrasonic signal to the measurement volume in which bubbles may be detected and then receives the echo. From the echo or received signal, a beat signal related to the repetition rate may be extracted and used to indicate the presence or absence of a resonant bubble. In a preferred embodiment, software control maintains the beat signal at a preselected frequency while varying the pump transducer frequency to excite bubbles of different diameters to resonate depending on the range of bubble diameters selected for investigation.