Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “reference systems”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,135 records · Page 63

ANALYSIS OF A HIGH TEMPERATURE GAS-COOLED REACTOR POWERED HIGH TEMPERATURE ELECTROLYSIS HYDROGEN PLANT

An updated reference design for a commercial-scale high-temperature electrolysis (HTE) plant for hydrogen production has been developed. The HTE plant is powered by a high-temperature gas-cooled reactor (HTGR) whose configuration and operating conditions are based on the latest design parameters planned for the Next Generation Nuclear Plant (NGNP). The current HTGR reference design specifies a reactor power of 600 MWt, with a primary system pressure of 7.0 MPa, and reactor inlet and outlet fluid temperatures of 322°C and 750°C, respectively. The reactor heat is used to produce heat and electric power to the HTE plant. A Rankine steam cycle with a power conversion efficiency of 44.4% was used to provide the electric power. The electrolysis unit used to produce hydrogen includes 1.1 million cells with a per-cell active area of 225 cm2. The reference hydrogen production plant operates at a system pressure of 5.0 MPa, and utilizes a steam-sweep system to remove the excess oxygen that is evolved on the anode (oxygen) side of the electrolyzer. The overall system thermal-to-hydrogen production efficiency (based on the higher heating value of the produced hydrogen) is 42.8% at a hydrogen production rate of 1.85 kg/s (66 million SCFD) and an oxygen production rate of 14.6 kg/s (33 million SCFD). An economic analysis of this plant was performed with realistic financial and cost estimating The results of the economic analysis demonstrated that the HTE hydrogen production plant driven by a high-temperature helium-cooled nuclear power plant can deliver hydrogen at a competitive cost. A cost of $3.03/kg of hydrogen was calculated assuming an internal rate of return of 10% and a debt to equity ratio of 80%/20% for a reactor cost of $2000/kWt and $2.41/kg of hydrogen for a reactor cost of $1400/kWt.

08 HYDROGEN↗

Wholesale Electricity Market Design with Increasing Levels of Renewable Generation: Incentivizing Flexibility in System Operations

This paper discusses the importance and challenges of incentivizing flexibility during short-term operations of the bulk power system due to the increasing variability and uncertainty from growing penetrations of variable generation (VG). Operational flexibility can refer to many aspects of a resource's capability to support the power system, such as the speed, range, and duration of power output, as well as the ability to autonomously respond to frequency or voltage changes. Inefficient utilization of existing flexibility, or unwillingness of resources to provide flexibility, can compromise system reliability by not meeting the changing net load, and it can also lead to higher costs when an inefficient use of flexibility resources occurs. There are many existing characteristics of market design that incentivize flexibility in some manner. How they incentivize the provision of flexibility as well as the level of flexibility is still debated. We explore some of these existing market designs, as well as new market mechanisms, such as pay-for-performance regulating reserve and flexible ramping products, that aim to explicitly incentivize the provision of more flexibility to the system, particularly as a result of increasing VG penetration levels.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Scalable Implementation of Mean-Field and Correlation Methods Based on Lie-Algebraic Similarity Transformation of Spin Hamiltonians in the Jordan–Wigner Representation

Recent work has highlighted that the strong correlation inherent in spin Hamiltonians can be effectively reduced by mapping spins to Fermions via the Jordan−Wigner transformation (JW). The Hartree−Fock method is straightforward in the Fermionic domain and may provide a reasonable approximation to the ground state. Correlation with respect to the Fermionic mean field can be recovered based on Lie-algebraic similarity transformation (LAST) with two-body correlators. Specifically, a unitary LAST variant eliminates the dependence on site ordering, while a nonunitary LAST yields size-extensive correlation energies. Whereas the first recent demonstration of such methods was restricted to small spin systems, we present efficient implementations using analytical gradients for the optimization with respect to the mean-field reference and the LAST parameters, thereby enabling the treatment of larger clusters, including systems with local spins s > $\frac{1}{2}$.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Autonomous Reactivity Control (ARC) — Principles, geometry and design process

The Autonomous Reactivity Control (ARC) system was developed to ensure inherent safety performance of Generation-IV reactors while having a minimal impact on reactor performance and economic viability. Here we present in detail the principles of how the ARC system operates, what materials should be used, what components make up the system and how they are interconnected. The relevant equations regarding how to design the system for a certain response are developed and defined, and the most important aspects determining the speed of actuation of the systems are analyzed. Thus, this study serves as the general reference material for all of the fundamental principles behind the ARC idea. Finally, we present a step-by-step guide to how a fast reactor fuel subassembly with an ARC system installed would be manufactured, using a full 3D-CAD model. For an ARC installation in a 1000 MWth sodium-cooled oxide-fueled fast reactor core, the system constitutes a relatively minor adjustment to a typical fuel assembly, increasing its total axial extent by ~5–10% and the total primary coolant pressure drop by ~1%. In conclusion, the main finding of this study is that it is possible to design, manufacture (using existing methods) and implement ARC systems in the fuel assemblies of fast reactor cores to provide inherent safety in all anticipated unprotected transients with only a modest increase in the length of the assembly and the pressure drop across the core.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Learning Constrained Parametric Differentiable Predictive Control Policies With Guarantees

We present differentiable predictive control (DPC), a method for offline learning of constrained neural control policies for nonlinear dynamical systems with performance guarantees. We show that the sensitivities of the parametric optimal control problem can be used to obtain direct policy gradients. Specifically, we employ automatic differentiation (AD) to efficiently compute the sensitivities of the model predictive control (MPC) objective function and constraints penalties. To guarantee safety upon deployment, we derive probabilistic guarantees on closed-loop stability and constraint satisfaction based on indicator functions and Hoeffding’s inequality. We empirically demonstrate that the proposed method can learn neural control policies for various parametric optimal control tasks. In particular, we show that the proposed DPC method can stabilize systems with unstable dynamics, track time-varying references, and satisfy nonlinear state and input constraints. Our DPC method has practical time savings compared to alternative approaches for fast and memory-efficient controller design. Specifically, DPC does not depend on a supervisory controller as opposed to approximate MPC based on imitation learning. We demonstrate that, without losing performance, DPC is scalable with greatly reduced demands on memory and computation compared to implicit and explicit MPC while being more sample efficient than model-free reinforcement learning (RL) algorithms.

97 MATHEMATICS AND COMPUTING↗

Validation of transfer map calculation for electrostatic deflectors in the code COSY INFINITY

The code COSY INFINITY uses a beamline coordinate system with a Frenet–Serret frame relative to the reference particle, and calculates differential algebra-valued transfer maps by integrating the ODEs of motion in the respective vector space over a differential algebra (DA). In our work, we described and performed computation of the DA transfer map of an electrostatic spherical deflector in a laboratory coordinate system using two conventional methods: (1) by integrating the ODEs of motion using a numerical integrator and (2) by computing analytically and in closed form the properties of the respective elliptical orbits from Kepler theory. We compared the resulting transfer maps with (3) the DA transfer map of COSY INFINITY’s built-in electrostatic spherical deflector element ESP and (4) the transfer map of the electrostatic spherical deflector computed using the program GIOS, which uses analytic formulas from a paper1 by Hermann Wollnik regarding second-order aberrations. In addition to the electrostatic spherical deflector, we studied an electrostatic cylindrical deflector, where the Kepler theory is not applicable. We computed the DA transfer map by the ODE integration method (1), and we compared it with the transfer maps by (3) COSY INFINITY’s built-in electrostatic cylindrical deflector element ECL and (4) GIOS. The transfer maps of electrostatic spherical and cylindrical deflectors obtained using the direct calculation methods (1) and (2) are in excellent agreement with those computed using (3) COSY INFINITY. On the other hand, we found a significant discrepancy with (4) the program GIOS.

43 PARTICLE ACCELERATORS↗

Determination and verification of a 2D pencil-beam kernel for a radiosurgery system with cones

The quality and correctness of dosimetric data of small fields in stereotactic radiosurgery (SRS) depends significantly on the election of the detector employed in the measurements. This work provides an independent method of verification of these data through the determination of a polyenergetic 2-dimensional pencil-beam kernel for a BrainLAB SRS system with cones, employing the deconvolution/convolution of a reference experimental off-axis ratio (OAR) profile (cone diameter c{sub 0} = 35 mm). The kernel in real space k{sub c{sub 0}}(r,z{sub 0}) is convolved with the ideal fluence Φ for the cones 7.5 to 35 mm in diameter to obtain the OAR profiles, and the total scatter factors, S{sub t}, which are compared with experimental values of the same quantities. The experimental OARs and S{sub t} factors are measured in water with a PTW 60003 diamond detector. Additionally, the reference OAR is corrected for beam divergence and spectral fluence fluctuations defining a function of boundary correction factors (BF). The BF and Φ functions are transformed to the conjugate space with the zeroth-order Hankel transform, appropriated to the radial symmetry of the cones. Therefore, the kernel in real space k{sub c{sub 0}}(r,z{sub 0}) is the inverse Hankel transform of the ratio of the Hankel transforms of BF and Φ. Finally, an uncertainty analysis according to the Guide to the Expression of Uncertainty in Measurement is carried out for 3 different values of k{sub c{sub 0}}(r,z{sub 0}). Calculated and measured OARs agree within the dose/distance-to-agreement criteria of 2%/0.12 mm; while, S{sub t} factors agree within 2%. This procedure supplies an independent method to validate the dosimetric data necessary to feed treatment planning systems for SRS with cones.

61 RADIATION PROTECTION AND DOSIMETRY↗

SPC-71260 Rev 0 MARVEL Heat Extraction Subsystem Secondary Coolant Equipment (SCE) Design/Build

A. The Microreactor Applications Research Validation and Evaluation (MARVEL) reactor will offer experimental capabilities that are not currently available at DOE’s national laboratories. Idaho National Laboratory (INL), operated for the U.S. Department of Energy (DOE) by Battelle Energy Alliance, LLC (BEA) (Contractor hereafter) is procuring services for the design, analysis, fabrication, testing and delivery of a Secondary Coolant Equipment system (SCE). This specification contains the requirements for design, analysis, fabrication, testing and delivery of the SCE as described herein. The MARVEL reactor is a microreactor which uses eutectic sodium-potassium alloy (NaK) as a primary coolant. The primary coolant is circulated through four primary loops by natural convection of the coolant. In each loop is a closed well which will accommodate an intermediate heat exchanger (IHX) for extracting heat from the loop. These wells will be referred to in this specification as the “IHX wells.” It is intended for the IHX containment to also be filled with NaK. The MARVEL design team has determined that a Heat Extraction System (HES) using pumped NaK will be used to extract heat from the IHXs and deliver it to a downstream system for power generation or alternate process heat users. This Heat Extraction System will enable MARVEL operations including the ability to test, demonstrate, and address issues related to installation, startup, and operations. In addition, it will allow down-stream utilization of process heat for various uses. The objective of this specification is to develop the final design for the HES Secondary Coolant Equipment system (SCE) that will be used as the core of the HES. This system provides control of the NaK circulation between the MARVEL reactor and the subsequent process heat utilization systems. It does not include design of the Intermediate Heat Exchangers and piping inside the T-REXc pit in which the reactor is located. B. The MARVEL microreactor will be installed in the Transient Reactor Test Facility (TREAT) building in the Transient Reactor Test (TREAT) Micro-Reactor Experiment Cell (T-REXc) C. An INL Subcontractor has developed a conceptual design for this system per SPC-71145, referred to in that specification as the Process Heat Extraction System. SPC-71260 is based on the pumped NaK loop concept developed under SPC-71145. D. The SCE system design and (as option scope) fabrication shall be provided by the awardee of the subcontract (Subcontractor hereafter) pertaining to this Specification. Prior to shipment, the SCE will be fabricated, assembled, and tested at the Subcontractor’s facility. After successful completion of acceptance testing, the SCE and associated equipment will be shipped to the Materials and Fuels Complex (MFC) at the INL (Contractor’s Facility hereafter) to be installed by others in TREAT/T-REXc.

21 - SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLAN↗

A Variable Pressure Multi-Pressure Rail System Design for Agricultural Applications

This paper presents a solution for reducing energy loss in the hydraulic control system of agricultural tractors and their implements. The solution is referred to as a multi-pressure rail (MPR) and provides power to the hydraulic functions following a pressure control logic, as opposed to the traditional flow control logic typical of hydraulic systems used in off-road vehicles. The proposed hydraulic control system allows for elimination of redundant flow control valves in the state-of-the-art system, which cause excessive throttling losses leading to poor overall energy efficiency. Related work on MPR technology targets construction vehicles, where the MPR solution can allow energy recovery during overrunning loads and better engine management. This paper alternatively addresses the case of agricultural applications where functions mostly operate under resistive load conditions with slow dynamics, which offers an opportunity to target throttle losses. For this purpose, the paper introduces a variable pressure control strategy to handle the instantaneous pressure at each rail. To develop both the controller and the hydraulic system architecture, a stationary test rig is conceived and used to validate a numerical simulation model of the MPR system and its control strategy. Particular focus is given to the dynamic behavior of the system during the switches of a function between different pressure rails, which needs to ensure reduced oscillations of the flow provided to each hydraulic function. Once validated, the simulation model is used to predict the energy savings of the MPR solution in an actual application: a 435 hp hydraulic tractor powering a 16-row planter, for which operating features during typical drive cycles were available to the authors. The results show up to 59% total power reduction at the pump shaft, corresponding to 89.8% system efficiency gain.

36 MATERIALS SCIENCE↗

ARRA Energy Storage Demonstration Projects: Lessons Learned and Recommendations

The American Recovery and Reinvestment Act (ARRA) of 2009 (Recovery Act) provided funding for 16 energy storage demonstration projects. The projects ranged in scope from feasibility studies and technology demonstrations to full-scale, operational energy storage plants. This investment had a significant positive impact on the grid-connected energy storage industry. The goal of this report is to summarize the lessons learned from the ARRA projects, and to make recommendations for future Department of Energy (DOE) investments. Information for this report primarily came from three sources: a questionnaire and interview with each project team; DOE energy storage program peer review presentations; and DOE reports required as part of the ARRA project. Some lessons learned were common to many projects. Development of standards, codes and protocols specific to energy storage systems will mitigate uncertainty over code compliance, streamline permitting, and should be a priority (especially related to safety). Removal of regulatory barriers that preclude optimal operation of an energy storage system with multiple applications would immediately enable further deployment (e.g., FERC standards preclude the marketing department from reliability activities). Maturity of the approach to monetization varies substantially between applications with frequency regulation as an ancillary service leading other applications. Finally, developers focused on ramp mitigation and time shifting envision a reference plant. This reference plant would scale up from the current demonstration systems and would lead to the deployment of 50 MW-scale peaker plants.

25 ENERGY STORAGE↗

Survey of Use Cases and Scenarios on the Open Energy Data Initiative Solar Systems Integration (OEDI SI) Platform

The Open Energy Data Initiative Solar Systems Integration (OEDI SI) Data and Modeling Platform offers a comprehensive set of use cases tailored for power systems analysis. Each use case is centered around a specific power system analysis problem, supported by composite input data and reference algorithms. These composite input datasets are meticulously assembled using OEDI SI's data preprocessing tools, which integrate raw data from various sources. The primary objectives of the OEDI SI Platform include facilitating access to composite input data through widely accepted input/output formats and verified results. This accessibility enables power system network researchers and developers to validate their algorithms and showcase their applications' capabilities to the broader community. Moreover, the platform strives to promote reproducible, robust, replicable, and generalizable solar systems integration research.

14 SOLAR ENERGY↗

Sci-Fri PM: Radiation Therapy, Planning, Imaging, and Special Techniques - 09: Impact of the distance of reflective markers from linac isocenter on the positional accuracy of an infrared tracking system

Purpose: The HexaPOD™ six degree of freedom couchtop is equipped with an optical tracking system, consisting of a stereoscopic camera and a reference frame (RF) carrying infrared reflective markers. The manufacturer recommends placing the RF within 50 cm from linac isocenter (ISO), which is a serious limitation since the RF does not fit around the shoulders of most brain patients. This study quantifies the impact of extended RF distances from ISO on positional accuracy. Methods: An in-house tool with an estimated resolution of 0.3 mm and 0.1° was used. It is a large cube and a mathematical model of HexaPOD motion to determine the intersection of room lasers with the ruled cube edges. Combinations of translations (±1 and ±3 cm) and rotations (±2.5°) were executed on two HexaPOD couchtops for multiple RF distances from ISO (35 to 77 cm). For each combination, ten laser readings were fed into a least squares algorithm to determine the executed translations and rotations while minimizing operator reading errors. Results: The usable tracking volume is up to an RF distance of 82 cm from ISO. Positional accuracy of the HexaPOD/iGuide system is 0.6 mm and 0.1° (95% confidence). Positional accuracy variations versus RF distance from ISO are statistically insignificant (p = 0.05). Our results generally confirm recent internal estimates by the manufacturer (for future release). Conclusions: RF distances up to 77 cm from ISO are clinically acceptable, provided performing a patient safety study with a verification scan.

60 APPLIED LIFE SCIENCES↗

A Fiber Optic Ultrasonic Sensing System for High Temperature Monitoring Using Optically Generated Ultrasonic Waves

This paper presents the design, fabrication, and characterization of a novel fiber optic ultrasonic sensing system based on the photoacoustic (PA) ultrasound generation principle and Fabry-Perot interferometer principle for high temperature monitoring applications. The velocity of a sound wave traveling in a medium is proportional to the medium’s temperature. The fiber optic ultrasonic sensing system was applied to measure the change of the velocity of sound. A fiber optic ultrasonic generator and a Fabry-Perot fiber sensor were used as the signal generator and receiver, respectively. A carbon black-polydimethylsiloxane (PDMS) material was utilized as the photoacoustic material for the fiber optic ultrasonic generator. Two tests were performed. The system verification test proves the ultrasound sensing capability. The high temperature test validates the high temperature measurement capability. The sensing system survived 700 °C. It successfully detects the ultrasonic signal and got the temperature measurements. The test results agreed with the reference sensor data. Two potential industry applications of fiber optic ultrasonic sensing system are, it could serve as an acoustic pyrometer for temperature field monitoring in an industrial combustion facility, and it could be used for exhaust gas temperature monitoring for a turbine engine.

47 OTHER INSTRUMENTATION↗

Adaptive controller for forced oscillation suppression in the grid

A control system and method for an inverter-based resource device provided in a synchronous power grid. The control system includes at least one inverter based resource device connected to an electrical power system, and a controller module. The inverter based resource device includes a reference power Pref, a combination module and a transfer function. The inverter based resource device injects modulated power into the power system. The power system (which is represented by a transfer function in the control system) receives an undesirable forced oscillation, which is connected to a measuring device. A controller module processes the measured output and provides a control signal to the inverter based resource device. The controller is arranged to suppress a forced oscillation detected in the power system.

Guttromson, Ross↗

Geminal embedding scheme for optimal atomic basis set construction in correlated calculations

We introduce an efficient method to construct optimal and system adaptive basis sets for use in electronic structure and quantum Monte Carlo calculations. The method is based on an embedding scheme in which a reference atom is singled out from its environment, while the entire system (atom and environment) is described by a Slater determinant or its antisymmetrized geminal power (AGP) extension. The embedding procedure described here allows for the systematic and consistent contraction of the primitive basis set into geminal embedded orbitals (GEOs), with a dramatic reduction of the number of variational parameters necessary to represent the many-body wave function, for a chosen target accuracy. Within the variational Monte Carlo method, the Slater or AGP part is determined by a variational minimization of the energy of the whole system in presence of a flexible and accurate Jastrow factor, representing most of the dynamical electronic correlation. The resulting GEO basis set opens the way for a fully controlled optimization of many-body wave functions in electronic structure calculation of bulk materials, namely, containing a large number of electrons and atoms. We present applications on the water molecule, the volume collapse transition in cerium, and the high-pressure liquid hydrogen.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Sensitivity Analysis of Wind Plant Performance to Key Turbine Design Parameters: A Systems Engineering Approach; Preprint

This paper introduces the development of a new software framework for research, design, and development of wind energy systems which is meant to 1) represent a full wind plant including all physical and nonphysical assets and associated costs up to the point of grid interconnection, 2) allow use of interchangeable models of varying fidelity for different aspects of the system, and 3) support system level multidisciplinary analyses and optimizations. This paper describes the design of the overall software capability and applies it to a global sensitivity analysis of wind turbine and plant performance and cost. The analysis was performed using three different model configurations involving different levels of fidelity, which illustrate how increasing fidelity can preserve important system interactions that build up to overall system performance and cost. Analyses were performed for a reference wind plant based on the National Renewable Energy Laboratory's 5-MW reference turbine at a mid-Atlantic offshore location within the United States.

17 WIND ENERGY↗

Radio-optical reference frame link using the U.S. Naval observatory astrograph and deep CCD imaging

Between 1997 and 2004 several observing runs were conducted, mainly with the CTIO 0.9 m, to image International Celestial Reference Frame (ICRF) counterparts (mostly QSOs) in order to determine accurate optical positions. Contemporary to these deep CCD images, the same fields were observed with the U.S. Naval Observatory astrograph in the same bandpass. They provide accurate positions on the Hipparcos/Tycho-2 system for stars in the 10-16 mag range used as reference stars for the deep CCD imaging data. Here we present final optical position results of 413 sources based on reference stars obtained by dedicated astrograph observations that were reduced following two different procedures. These optical positions are compared to radio very long baseline interferometry positions. The current optical system is not perfectly aligned to the ICRF radio system with rigid body rotation angles of 3-5 mas (= 3σ level) found between them for all three axes. Furthermore, statistically, the optical-radio position differences are found to exceed the total, combined, known errors in the observations. Systematic errors in the optical reference star positions and physical offsets between the centers of optical and radio emissions are both identified as likely causes. A detrimental, astrophysical, random noise component is postulated to be on about the 10 mas level. If confirmed by future observations, this could severely limit the Gaia to ICRF reference frame alignment accuracy to an error of about 0.5 mas per coordinate axis with the current number of sources envisioned to provide the link. A list of 36 ICRF sources without the detection of an optical counterpart to a limiting magnitude of about R = 22 is provided as well.

79 ASTRONOMY AND ASTROPHYSICS↗

Determination of absorbed dose in water at the reference point D(r{sub 0},{theta}{sub 0}) for an {sup 192}Ir HDR brachytherapy source using a Fricke system

A ring-shaped Fricke device was developed to measure the absolute dose on the transverse bisector of a {sup 192}Ir high dose rate (HDR) source at 1 cm from its center in water, D(r{sub 0},{theta}{sub 0}). It consists of a polymethylmethacrylate (PMMA) rod (axial axis) with a cylindrical cavity at its center to insert the {sup 192}Ir radioactive source. A ring cavity around the source with 1.5 mm thickness and 5 mm height is centered at 1 cm from the central axis of the source. This ring cavity is etched in a disk shaped base with 2.65 cm diameter and 0.90 cm thickness. The cavity has a wall around it 0.25 cm thick. This ring is filled with Fricke solution, sealed, and the whole assembly is immersed in water during irradiations. The device takes advantage of the cylindrical geometry to measure D(r{sub 0},{theta}{sub 0}). Irradiations were performed with a Nucletron microselectron HDR unit loaded with an {sup 192}Ir Alpha Omega radioactive source. A Spectronic 1001 spectrophotometer was used to measure the optical absorbance using a 1 mL quartz cuvette with 1.00 cm light pathlength. The PENELOPE Monte Carlo code (MC) was utilized to simulate the Fricke device and the {sup 192}Ir Alpha Omega source in detail to calculate the perturbation introduced by the PMMA material. A NIST traceable calibrated well type ionization chamber was used to determine the air-kerma strength, and a published dose-rate constant was used to determine the dose rate at the reference point. The time to deliver 30.00 Gy to the reference point was calculated. This absorbed dose was then compared to the absorbed dose measured by the Fricke solution. Based on MC simulation, the PMMA of the Fricke device increases the D(r{sub 0},{theta}{sub 0}) by 2.0%. Applying the corresponding correction factor, the D(r{sub 0},{theta}{sub 0}) value assessed with the Fricke device agrees within 2.0% with the expected value with a total combined uncertainty of 3.43%(k=1). The Fricke device provides a promising method towards calibration of brachytherapy radiation sources in terms of D(r{sub 0},{theta}{sub 0}) and audit HDR source calibrations.

62 RADIOLOGY AND NUCLEAR MEDICINE↗